PIPELINE DEFECT MAPPER

Similar documents
Pipeline Current Mapper

QLD/NT NSW WA

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2

pipeline integrity PCM + Pipeline Current Mapper

vscan Data Sheet V1.0

vloc Series 2 Smaller and lighter Over four times battery life Define, set and lock available features Customizable startup screen and much more...

UTILITY LOCATING EQUIPMENT

Radiodetection Pipeline Products

Tender NO. PGVCL/PROC/Cable & Pipeline Locator/832

CIPS, DCVG & GPCM Pipeline Surveyor. Corrosion Control Equipment

Loc-5Tx Data Sheet V2.1

AT-5000 Professional Underground Cable / Pipe Locator System

Nine LEDs provide feedback of transmitter operation. Induction selected One Red LED Frequency/Mode selection Four Green LEDs

vlocdm User Handbook (English Edition) Version 2.0

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

vlocdm2 User Handbook

UAT-600 Series. amprobe.com

cable and pipe locators RD Utility cable and pipe locator

Universal precision cable and pipe locator

vlocdm2 User Handbook

Obsolete Document. Dynatel

Dynatel Cable/Pipe and Fault Locator 2273M Cable/Pipe, Fault and Marker Locator 2273M-iD

Specifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators

DOCUMENT OBSOLETE. Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

User Guide. Life detection with. RescueRadar

PCMx: faster pipeline surveying with simultaneous data gathering

Portable Multi-Channel Recorder Model DAS240-BAT

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

Precision Pipeline Locator System User Guide. Rev

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

MAGNETIC FIELD METER Operator s Manual

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

I N N O V A T I N G U N D E R G R O U N D L O C A T I N G

Utility cable and pipe locator

Product Introduction ML8720C. Area Tester ML8740B. Area Scanner

IT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual

Universal precision cable and pipe locator

PV210. Why buy the PV210?

TRIAD SERIES 2310 SC

Power Quality Recorders with Wireless Communications

DGT USB e-board manual English

Fluke 370 FC Series true-rms wireless AC/DC clamp meters

Indian Institute of Technology Kanpur Department of Civil Engineering

GeoMax GNSS Zenith10 & Zenith20 Series

Dynatel 2250E/2273E Advanced Cable and Fault Locator

EZi & ULTRA SYSTEMS. Cable Tracing and Locating EZi & ULTRA Sytems

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

Ca b l e Tr a c i n g a n d L o c a t i n g EZi & ULTRA Sytems

PCMx. Pipeline Current Mapper system. User Guide 90/UG105INT/01

Pipe & cable locator for avoidance & tracing applications. The ideal choice for the novice through to the skilled technician

vlocpro NEW Features & Accessories NEW Standard Features available now! New Displays

PPA 377. Personal PA FM Listening System FM SPECIFICATION DATA. System Includes:

Leica Digisystem i-series Safe and fast location of underground utilities

vloc-9800 User Handbook (English Edition) Version 1.3 P/N:

JD723A/JD724B/JD726A Cable and Antenna Analyzers

PV200. Why buy the PV200? The most compact I-V curve tracer around.

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related

DGT Smart Board manual English

GC723A / GC724B Cable and Antenna Analyzer

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

GPS Pathfinder ProXH and ProXT Customer FAQs

INDEX. Accessories and Components System Unit and Joystick Assembly and Charging the Battery Using with LED System...

User Manual. This User Manual will guide you through the steps to set up your Spike and take measurements.

Firmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field.

MEQ15BT. INSTALLATION / OWNER'S MANUAL Wireless Smart EQ Processor FCC ID : GJW-SBT504 IC ID : 4038A-SBT504

3M Dynatel Cable/Pipe/Fault Locator 2550/2573 Series

Instruction Manual. Model XTpc-33 khz Pipe & Cable Locator

Leica Digisystem Safe and fast location of underground services

leica-geosystems.com Leica DD SMART utility locator solution Work safer, work smarter, work simpler

PIECAL 211 Automated RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

WE-525T Antenna Analyzer Manual and Specification

Review: The MFJ-225 Graphical Antenna Analyzer Phil Salas AD5X

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

SeekTech SR-60 SeekTech SR-20 NaviTrack Scout

TRACKING. ABOVE GROUND MARKER Pg RECEIVERS Pg TRANSMITTERS Pg. 8-3 to 8-5. GEOPHONE Pg DELRIN CANS Pg RENTALS Pg.

Energy Explorer PROFESSIONAL POWER & HARMONICS ANALYSER

Leica Digicat i-series Safe and fast location of underground services

Metrolog HL7000 TM. Acoustic Leak Logging System. Simple Reliable Efficient. Reduce Water Leaks Faster...

MAGNETIC FIELD METER Operator s Manual

3 Dynatel M Series Locating and Marking System DOCUMENT NEW- TO- THE- WORLD TECHNOLOGY OBSOLETE DAMAGE PREVENTION PIN- POINT ACCURACY SAFETY

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description

MINIMUM SYSTEM REQUIREMENTS

Utility cable and pipe locator

ZONESCAN net Version 1.4.0

FM RADIO TRANSMITTER

A higher performance product designed for safer excavating.

Firmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field.

Metrolog HL7000TM. Acoustic Leak Logging System. Simple Reliable. Reduce Water Leaks Faster...

Remote Radio Control. M880 WAVE2 C Transmitter Range. M880 for Low Integrity Stop Circuit Applications

RD8100 Locator Specification

Measurement solutions for single-mode fibers

DCVG Training Manual DA Meter Version

Surface Potential Surveys Training Manual DA Meter Version

NoiseMeters. The Practical & Easy To Use Solution for Industrial & Environmental Noise Measurements.

CALRAD MINIATURE MULTI-CLICK DUAL CONTROLS 40 STEP P.C. MOUNT 11

Locator Accessories DATA SHEETS. Accessory Range for Pipe & Cable Location Equipment

Owner s Manual For Models G-225 & G-227 GMRS/FRS Radio

F I S H E R R E S E A R C H L A B O R A T O R Y

Architectural/Engineering Specification for a. Microwave Perimeter Intrusion Detection System

Transcription:

PIPELINE DEFECT MAPPER Receiver Colour Display C.A.T. Survey Graph ACVG Survey Graph GIS View General: The Pipeline Defect Mapper Kit designed and developed in such a way; to precisely locate and assist in evaluating coating defects of Cathodically Protected underground pipelines, mapping the distribution of current on pipeline networks and for long distance pipeline locating. The profile current can be applied at any CP point for the measurements by rugged hand-held receiver. Results are in the form of data or graphs (plots) which can be viewed on receiver s display or during post processing at office. Recorded GPS co-ordinates help in generating an automatic GIS view after downloading to computer / laptop of pipeline section surveyed. Surveyed data can be viewed on GIS view pins with date and time stamping. Ph.: +91-120-2842077 E-mail: sales@gicgroup.co.in Website:

Overview of vlocdm System: The vlocdm (Defect Mapper) has been designed to carry-out: Pipeline location, orientation, depth measurement and GPS co-ordinates Current Attenuation Test (CAT) survey of Cathodically protected pipelines for coating faults A. C. Voltage Gradient (ACVG) survey with A-Frame to pin-point the faults precisely Records transferable to laptop / desktop for Analysis, Interpretation and GIS View The Pipeline Defect Mapper (PDM) Kit uses the latest locating and signal processing techniques to plot the current gradient of an industry standard low frequency (3Hz) profiling current. The current is typically applied at CP stations so minimizing disruption of the pipeline. The vlocdm 150W Transmitter is used to apply a signal current to the anode bed. The pipeline returns the signal, via coating faults, back to the transmitter. The transmitter is designed to be powered from CP (Cathodic Protection) stations DC supply or Mains AC supply; eliminating the need for batteries. However, as per requirement external battery source can also be used. The non-intrusive measuring device; vlocdm Receiver records the measurements along the pipeline and plots the results directly onto the colour screen of the receiver. There is no need to carry extra logging and display devices. A +/- 3M accuracy external GPS antenna is included with the standard kit supply. It links to the vlocdm Receiver via a Bluetooth radio link. The GPS ensures the user can generate real time current gradient graphs and guides the user back to a point of interest by highlighting the user position on the graph. This feature is called the Walk-Back feature. Storing the results also has the benefit of facilitating the data recording of app. 1000 logs. All the data is logged into the receiver memory which can be downloaded to a spread sheet and / or kml file format; allows the CP engineer to establish trends of coating deterioration and GIS view. The A-Frame Fault Finding Accessory is used to accurately locate the position of a coating fault. Locate centerline and line orientation; place A-Frame at every Meter; record the db signal and view the generated Signature Graph. An arrow points the user to the position of the fault whilst quickly and efficiently graphing the characteristic shape and magnitude of fault signal on the receivers display. This ensures the user minimizes the chances of misidentification. Standard Equipment package comprising of: Receiver with rechargeable and alkaline batteries, Mains charger, Accessories soft bag and soft carry bag for receiver, 150 Watt Transmitter with direct connection lead; DC input lead and Mains input lead, A-Frame with connecting cable to receiver and soft carry bag, USB download / upload data cable, Bluetooth GPS (External) dully fitted with receiver in GPS plastic holder, Bluetooth (Internal), vlocdm Download Application Software through website and English User Handbook. Ph.: +91-120-2842077 E-mail: sales@gicgroup.co.in Website:

Features: 1. Sleek and light-weight design 2. Rugged, custom Carbon fiber and ABS housing 3. Receiver s colour display 4. Dual Core Processor 5. Both Alkaline batteries and rechargeable batteries for receiver 6. Locator receiver s colour display; displays operating frequency, continuous battery checks, speaker volume, Bluetooth, GPS, depth, distance, Line orientation, graphs, log number and signal strength in db 7. Intuitive setup menu enables user to configure: Selection of Frequencies available, Sonde / Line, Units of measure (feet / meters), Power mode selection for 50Hz or 60Hz environment, Pitch /Normal sound modulation, Favorite Mode Selection, Language, Continuous Depth, Speaker and Backlight Level. 8. Null, Peak and Peak with arrows locating methods with graphics 9. Live power cable locating mode by vlocdm Receiver only without physical connections to cable 10. Cathodically protected pipelines can be located by vlocdm receiver only without physical connections to pipeline by using CP100 frequency mode (dependant on signal travelling from pipeline CP rectifier unit) 11. Continuous depth information 12. Bluetooth GPS connectivity 13. Continuous battery check status 14. Log numbers display 15. Display Real Time Distance from last survey point (when GPS facility activated) 16. Single push button for total measurements and recording by enter push button 17. CAT & ACVG Graph generation to have Instant View of Current Attenuation & Voltage Gradient profile 18. A-Frame for pin-pointing faults and for ACVG surveys 19. Locate information recorded internally; can export to external devices such as laptop/desktop 20. USB interface to receiver for operating software and accessories 21. vloc PC Kit downloadable software through website 22. Data can be saved in Excel file format for analysis, interpretation and report generation 23. Date can also be saved in kml file format for having GIS View and print of pipeline ROU with data 24. Transmitter have selectable input power options for 100V AC-240V AC or 12V DC-60V DC 25. Transmitter output power of 150 Watt 26. Multiple frequencies including 3 / 4 /6 / 8 / 98 / 128 / 512 / 640Hz and Fault Finding Modulation 27. Able to transmit simultaneous multiple frequencies (selectable) 28. Environment Protection: IP 54 & NEMA 4, 29. Temperature Range: Operating -20 to +50 Deg. C. and Storage -40 to +60 Deg. C. 30. Standard warranty: 12 Months 31. Complies with European Standards CE (directive 99/5/EC) and FCC Rules Para 15 EN 61000-6-4-2007, EN 61000-4-3-2007, EN 61000-4-2-1995, A1 & A2, EN 61000-4-8-1994 A1, ETSI EN 300 330-2: 2006, ESTI EN 301 489-1-2005, ESTI EN 301 489-3-2002, CFR 47 PART 2: 2004, CFR 47 PART 15: 2006, ANSI C63.4: 2003 Ph.: +91-120-2842077 E-mail: sales@gicgroup.co.in Website:

Downloading Data to a PC Latest license free application software is available through manufacturer s website. This application allows the use of the vlocdm data in standard spread sheets such as Microsoft Excel and kml file format. The application is compatible with Windows 2000, Windows XP, Windows Vista and Windows 7. Connect the Receiver to the PC using a USB cable and switch on the receiver. The PC should detect that here is a USB device connected. Double click on the vlocpckit and connect receiver. Download the data and then click save as option to save as Excel File in a designated folder. It is now possible to generate a graph. Graphs are most commonly done as DM current against accumulated distance. Highlight the Accumulated distance records and then press the Ctrl key whilst highlighting the DM current column. From the Insert tab select scatter plot. And from the menu select the desired Graph. The graph will then be generated. Date can be reviewed, analyse, interprete and used for report regeration. Again click on save as option and choose kml file. If Google Earth is available on your PC (or may download first); click on saved kml file to have GIS View of surveyed pipeline section with data. Ph.: +91-120-2842077 E-mail: sales@gicgroup.co.in Website:

Technical Specifications Receiver: 1. Sharp TFT LCD ¼ VGA colour display of 3.52 inch 2. Internal rechargeable (6 x AA Ni-MH) and replaceable (6 x AA alkaline battery) batteries 3. Life for alkaline / Ni-MH batteries of app. 6 hrs. of intermittent use at 21 Deg. C. 4. Antennas: 2 x Horizontal, 1 x 90 Deg., 1 x Null (Air cored) and 1 x Magnetometer 5. Communication: Bluetooth and USB 6. Construction: Carbon Fiber Reinforced Antenna tube. High Impact thermoplastic (ABS) housing 7. Complies with European standard CE(directive 99/5/EC) and FCC Rules Para 15 8. Displayed information: Signal Strength, Mode Indication, Left/Right Indication, Line Direction Compass, DM Signal Direction, Automatic Recognition of Accessories, Depth Measurement, Peak /Null/Broad Peak Signal Indications, Transmitted Current Measurement, DM Mapping Current Measurement, Line Locating Mode, Gain Level (in db), Battery Check, Operating frequency, Speaker Volume, Log Number, Real Time DM Mapping and On-Screen Graphics, Real Time A-Frame Fault Mapping and On-Screen Graphics, Distance from last measurement with GPS activated 9. Setup menu for Frequency, Line Locating, Units, Power Mode, Continuous Depth Display and Backlight 10. Defect Mapper Frequencies: 3Hz, Signal Direction Frequency: 6 Hz 11. Locate Frequencies: 98Hz, 128Hz, 512Hz and 640Hz 12. Depth Display Range & Accuracy: +/- 5% up to 5 M and + / - 10% up to 8 M 13. A-Frame: 14. Data Storage: 1000 Data Point Storage. Transferable to PC for Excel report & kml files. 15. Digital and Manual Gain control 16. Temperature Range: Operating -20 to +50 Deg. C. and Storage -40 to +60 Deg. C. 17. Weatherproof: IP54 and NEMA 4 18. Weight app. App. 3.5Kg. Transmitter: 1. Construction: High Impact Plastic and Weight app. 12.5 Kg. 2. Display type: Mono Dot Matrix Display (60 x 30 mm) 3. Power Supply: 100-250V AC or 12-60V DC (DC power can be derived from vehicle battery or CP output) 4. Connectors for Mains Input, DC Input and Transmitter Output 5. Complies with European standard CE (directive 99/5/EC) and FCC Rules Para 15 6. Standard accessories: Direct Connection Lead, Mains Input Lead and DC Input Lead 7. Displayed Information: Output Frequency, Output Current Setting and Output Current Actual 8. Signal Application Mode: Direct Connection Mode 9. Transmitting Frequencies: 98, 128, 512, 640, 3/98, 3/128, 4/98, 4/128Hz, ELF1: 3/6/98 Hz; ELF2: 3/6/128Hz, ELF3: 4/8/98Hz, ELF4: 4/8/128Hz, 3/6/512Hz; 3/6/640Hz; 4/8/512 & 4/8/640Hz 10. Power Output (Transmitting Mode): Powered by AC: 150 Watt, Powered by DC (12-20V): 50W 11. Output Voltage: 120V RMS (maximum) with output Fuse Protection 12. Output Current: 4A RMS (maximum) with up to 2 frequencies 13. Controls: Uses 2 Rotary / Push control knob for selecting Frequency, Output Level, Information and On/Off 14. Temperature Range: Operating -20 to +50 Deg. C. and Storage -40 to +60 Deg. C. 15. Weatherproof: IP54 and NEMA 4 A-Frame: 1. Sensitivity up to 3M Ohm defects 2. Carbon fiber reinforced glass fiber construction 3. Operating Frequency: 3 & 6 Hz 4. Weight app. 1.8 Kgs. Ph.: +91-120-2842077 E-mail: sales@gicgroup.co.in Website: