Submittal Transmittal

Similar documents
Installation Instructions

Installation Instructions for 30, 40, and 50 Series Plastic Laminate Toilet Partitions.

BioPrism Solid Surface

Melamine Plastic Laminate. Toilet Partition Installation Manual

Installation Manual for Metal Toilet Partitions Standard Series

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

Installation Manual for Metal Toilet Partitions Elite & Elite Plus Series

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

Installation Instructions

INSTALLATION INSTRUCTIONS


INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions

Stainless Steel 95C34 Series

INSTALLATION INSTRUCTION

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Manual. Solid Plastic Toilet Partitions. IN CANADA & AREAS OTHER THAN U.S.A.: IN THE U.S.A.:

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS FOR ALPACO CLASSIC PARTITIONS

Table of Contents IMPORTANT

INSTALLATION INSTRUCTIONS

Installation. *HDWC-INSTR-007* HDWC-INSTR-007 Rev. K; ECN G 2018 Bradley Page 1 of 24 3/22/2018

INSTALLATION INSTRUCTIONS FOR ALPACO CLASSIC PARTITIONS

Table of Contents IMPORTANT

Installation *HDWL-INSTR-001* IMPORTANT. Plastic Laminate Restroom Partitions Floor-Mounted with Overhead Brace Series 400

Installation. *HDWC-INSTR-006* HDWC-INSTR-006 Rev. K; ECN G 2018 Bradley Page 1 of 24 3/22/2018

INSTALLATION INSTRUCTIONS

Installation. *HDWC-INSTR-008* HDWC-INSTR-008 Rev. H; ECN G 2018 Bradley Page 1 of 24 3/22/2018

EUROLINE CLASSIC PHENOLIC / EVERGREEN. Installation Instructions. Installation Instructions.

STANDARD STALL INSTALLATION DETAIL

EUROLINE CLASSIC SOLID SURFACE Installation Instructions

Toilet Partition Hardware

Hardware. Brackets. Cast Chrome Plated Zamac Door Pack for High Pressure Laminate Compartments T O I L E T P A R T I T I O N S

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS SierraSeries SOLID COLOR REINFORCED COMPOSITE (SCRC) TOILET PARTITIONS

HEADRAIL BRACED INSTALLATION MANUAL. Tools Required

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

INSTALLATION INSTRUCTIONS GRILLE GUARD 09-ON DODGE RAM PART #

Oxford Stalls Installation Instructions

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

MobileTrak5 Installation Instructions

Assembly Instructions Music Library System

PRE-ENGINEERED HORSE STALL SYSTEMS SDFD SLIDING DOOR c/w FOLD-DOWN GRILL. & Assembly. Installation Instructions

EZ-MATRIX I N S TA L L AT I O N I N S T R U C T I O N S EZ-MATRIX

K.D. LOCKER ASSEMBLY INSTRUCTIONS

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS GRILLE GUARD RAM 1500 PART # 5058/5058-2

Installation Manual For ToddPod Outdoor Shower Enclosures

Install Instructions. NewAge Steel Welded Tall Locker

INSTALLATION INSTRUCTIONS SIDE BAR FORD ESCAPE & MAZDA TRIBUTE PART #

A. It is preferred that all submittals to be submitted electronically in PDF format.

CertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS. Fence Installation Guide 3', 4' & 6' High

SECTION 10520: FIRE EXTINGUISHERS AND CABINETS

Installation Instructions - Model V4JSD 1

FENCE INSTALLATION GUIDE 8 HIGH WALLS

Shetland Stalls Installation Instructions

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

SECTION BULLET- RESISTANT DOORS

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION METAL LOCKERS

Thermally Broken Framing and Door Installation

MX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

Assembly Instructions

Assembly Instructions

PRE-ENGINEERED HORSE STALL SYSTEMS 4884 HSD STANDARD SLIDING DOOR. & Assembly. Installation Instructions

Floor Stops - Dome. FS13 Dome Stop. FS17 Dome Stop. R14 Riser. Features:

INSTALL INSTRUCTIONS WELCOME TO THE NEWAGE PERFORMANCE CABINETRY SERIES NEWAGE STEEL WELDED CABINETRY

INSTALLATION INSTRUCTIONS / DODGE RAM CREW CAB 2500/3500

Preference Collection and Treatment Console INSTALLATION GUIDE

MANUFACTURING INC. Specifications

Heavy Wall Applied Stop Tube Frame and Door Installation

Ultra Fast Delivery SGL Toilet Cubicle Pack Fitting Instructions

Passenger/Right Front Mounting Bracket

K9 KIT INSTALLATION INSTRUCTIONS CROWN VIC KK-K9-F7-K

Section 1 Cubicles. Section 2 IPS Duct Panel Systems. Section 3 - Vanity Units Components & Assembly 12. Section 4 Basic Maintenance.

GENERAL INSTALLATION GUIDE: WARRANTY: PRODUCT INFORMATION T F

Frameless Inline Door With Return QCI5263

INSTALLATION INSTRUCTIONS

Adjustable Countertop Installation

Important Notice. caution: Use proper lifting equipment and correct procedures to avoid injury.

MATRIX GUARD. I nstallation I nstructions TERMS AND CONDITIONS. Call or visit

Mast Solutions Document/Installation Manual

Midmark Stainless Steel Cages Setup Manual

VIEWPOINT ALUMINUM RUNNING BOARD TOYOTA RAV4

ASSEMBLY MANUAL WALL MOUNT RACK SR-WM-10U SR-WM-12U SR-WM-16U

Design and Construction Standards SECTION ATHLETIC LOCKERS

Track Rack. * Track Racks are not lockable

Installation Instructions

Installation Instruction

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

FENCE INSTALLATION GUIDE 6 HIGH FENCE

(2) 25mm x 20mm x 5mm Adhesive Backed Foam Pads. 100mm x 50mm x 1.0mm Adhesive Backed Foam. (2) Spacer Plates. Passenger/Right Side Frame Mounting

3 BRACKET TO GUIDE ATTACHMENT. RIGHT END Figure 1. EXTENDED BRACKET (for doors taller than 8-8 ) SERIES 650. RIGHT END COTTER PIN Figure 6

INSTALLATION GUIDE. TRANZFORM Sound TRANZFORM Space

Transcription:

Submittal Transmittal Detailed, Group by Number Date: 1/9/2014 Reference Number: 0653 Transmitted To: Jenn Foskett Transmitted By: Tristie Tajima W H Cress Company Inc. Skanska USA Building Inc. 1824 Bickford Avenue Suite: F Snohomish, WA 98290 Tel: 425-334-8984 Fax: 425-334-9351 221 Yale Ave. N., Suite 400 Seattle, WA 98109 Tel: 206-726-8000 Fax: 206-328-9235 Qty 1 Submittal Package No Description Due Date Package Action 0139-102109 - 0 Stainless Steel Toilet Compartments 1/23/2014 Approved as Noted Transmitted For Delivered Via Tracking Number Information Email Items Qty Spec Sub Spec Description 0001 1 102109 1.2.A Stainless Steel Toilet Compartments - Product Data 0002 1 102109 1.2.C Stainless Steel Toilet Compartments - Shop Drawings 0003 1 102109 1.2.B.1 Stainless Steel Toilet Compartments - LEED Credit IEQ 4.1 0004 1 102109 1.2.B.2 Stainless Steel Toilet Compartments - LEED Credit IEQ 4.2 0005 1 102109 1.2.B.3 Stainless Steel Toilet Compartments - LEED Credit MR 4 0006 1 102109 1.2.B.4 Stainless Steel Toilet Compartments - LEED Credit MR 5 Notes Item Action Approved Approved as Noted Approved Approved Approved Approved Cc: Company Name Contact Name Copies Notes Remarks Signature Signed Date

Submittal Transmittal Detailed, Group by Number Date: 1/7/2014 Reference Number: 0635 Transmitted To: John Mrozek Transmitted By: Tristie Tajima LMN Architects Skanska USA Building Inc. 8012nd Ave., Suite 501 Seattle, WA 98104 Tel: 206-682-3460 221 Yale Ave. N., Suite 400 Seattle, WA 98109 Tel: 206-726-8000 Fax: 206-328-9235 Qty 1 Submittal Package No Description Due Date Package Action 0139-102109 - 0 Stainless Steel Toilet Compartments 1/21/2014 Submitted Transmitted For Delivered Via Tracking Number Approval E-Mail Items Qty Spec Sub Spec Description 0001 1 102109 1.2.A Stainless Steel Toilet Compartments - Product Data 0002 1 102109 1.2.C Stainless Steel Toilet Compartments - Shop Drawings 0003 1 102109 1.2.B.1 Stainless Steel Toilet Compartments - LEED Credit IEQ 4.1 0004 1 102109 1.2.B.2 Stainless Steel Toilet Compartments - LEED Credit IEQ 4.2 0005 1 102109 1.2.B.3 Stainless Steel Toilet Compartments - LEED Credit MR 4 0006 1 102109 1.2.B.4 Stainless Steel Toilet Compartments - LEED Credit MR 5 Notes Item Action Submitted Submitted Submitted Submitted Submitted Submitted Cc: Company Name Contact Name Copies Notes Remarks Signature Signed Date

Partition Mounting Styles Accurate Partitions http://www.accuratepartitions.com/mounting-styles Page 1 of 2 12/23/2013 Home Contact Us Site Map MOUNTING STYLES Floor Anchored/Overhead Braced Ceiling Hung This economical and sturdy mounting style installs just about anywhere. An anodized aluminum antigrip headrail secures partitions firmly to the walls. Floor Anchored Provides unobstructed floor area for a clean look and economical maintenance. When used with wall-hung fixtures, the entire floor is accessible for efficient cleaning. Structural steel ceiling supports are necessary to assure proper installation. Floor to Ceiling Anchored This mounting style gives a modern, contemporary appearance especially suitable for low-ceiling washrooms. Simplified construction permits ease of installation anywhere. For concrete floors only: 2 minimum penetration into floor required. Extremely stable and durable as pilasters are anchored into both the concrete floor and the structural ceiling support. Recommended for busy washrooms where abusive treatment is possible and vandal resistance is critical. SEARCH keywords Go

Stainless Steel Partitions Accurate Partitions http://www.accuratepartitions.com/stainless-steel Page 1 of 2 12/23/2013 Home Contact Us Site Map STAINLESS STEEL Accurate Partitions stainless steel toilet partitions are virtually indestructible and retain their gleaming beauty indefinitely. These units combine the strength of #304 stainless steel with a #4 satin finish or textured finish, formed and bonded to a honeycomb core. The face sheets are held rigid and permanently in place by an interlocking strip welded at each corner. Accurate Partitions stainless steel components are impervious to just about any substance. Even scratches caused by deliberate vandalism can be removed by buffing. The elegance of Accurate stainless steel components complements any design scheme, either in new construction or for renovations. Mounting STYLES HARDWARE FINISHES URINAL & PRIVACY SCREENS PRIVACY OPTIONS DETAILS & SPECIFICATIONS SHOWERS & VANITY TOPS APPLICATION GUIDE SEARCH keywords Go

INSTALLATION INSTRUCTIONS / STEEL PARTITIONS INSTALLATION INSTRUCTIONS / STEEL PARTITIONS CEILING HUNG CEILING HUNG 6 CARE AND MAINTENANCE USE THESE SIZES FOR DRILLING (ALL FASTENERS ARE T25 TORX) #9 drill for #14 x ⅝ sheet metal screws ¼ carbide drill for conical anchors ¼ high speed drill for hinge and stop/keeper thru bolts 7/16 high speed steel drill for ⅜ threaded rod In order to provide toilet partitions with the proper care and maintenance, the following instructions must be followed. a. All surfaces must be kept clean with water and a mild soap solution. b. Water left on units for extended periods will damage surface. The finish must be wiped dry following cleaning. c. In high humidity areas, the room must be properly ventilated. d. Refer to www.accuratepartitions.com for complete Care and Maintenance instructions. 1 INSPECTION The components for this project have been custom fabricated. They were inspected at the factory and all workmanship is guaranteed. Before beginning work, the units should be inspected. If damage occurred in transit, report immediately to the freight company or other agencies that may have caused the damage. 2 LAYOUT 3 WALL BRACKETS & CEILING STUDS 7 PRE-PACKAGED HARDWARE KITS For your convenience and ease of installation, this shipment contains pre-packaged hardware for all standard toilet partition layouts. The packages are numbered as follows and should be used as shown on the diagram. Figure 7 a. Verify room dimensions and check all materials and hardware. b. Exposed beam installation: Strike a chalk line on beam parallel to plumbing wall to mark center of pilasters. Dimension from rear wall is ⅝" less than overall depth on the shop drawings. Example: standard 60 stall requires 59⅜" centerline. c. Establish and mark centerline between water closets on the back wall, thereby locating center panels. Mark wall bracket elevations at 18" and 64" above floor at center of panels and wall pilaster(s), adjusting as required for grout lines. d. Begin at side wall and lay out pilasters on the beam/ceiling centerline using the bolt layout dimension shown on the shop drawings. Note: bolts are 1" in from each edge of pilaster. e. Transfer panel centers on wall to beam/ceiling centerline, thereby locating center of panel on pilaster. Stand pilasters against wall (protecting wall and floor as necessary) in order as shown on shop drawings. Locate hinge holes to the left or right as viewed from inside toilet compartment. Mark bracket locations 6" and 52" up from bottom of pilaster. Transfer panel centers from beam/ceiling layout to pilaster. Note: if panel is not centered on pilaster, make sure dimensions are marked correctly; example 6" from left and 4" from right. a. Mark bracket hole locations using appropriate bracket ("F" bracket for wall pilaster and end panels, "W" bracket for intermediate panels and "U" brackets on pilasters) as template. b. Drill appropriate size holes, ¼" for walls and #9 on pilasters (Note: use a "stop" on drill bit to prevent dimpling pilaster face). Before proceeding, confirm that the backing of the walls is adequate to support secure mounting of the toilet compartments. c. Attach brackets to masonry walls using #12 x 2½" sheet metal screws and conical anchors. If fastening to plaster or dry wall, use toggle bolts or mollys (supplied by others). Attach "U" brackets to pilasters using #14 x ⅝" sheet metal screws. d. For an exposed beam, drill 7/16" hole and install threaded rod, using washers and nuts provided. e. For beam above finished ceiling, drill 5/16" hole and thread with ⅜" x 16 tap. In either case, allow threaded rod to project downward a minimum of 2½" below the finished ceiling. Place trim clip on threaded rod and draw up tight to exposed beam or finished ceiling with hex nut. BRACKET PRE-PACK KITS PP-5 Bracket Pre-Pack #5 Kit - Pilaster to Wall PP-6 Bracket Pre-Pack #6 Kit - Intermediate Pilaster to Panel to Wall PP-7 Bracket Pre-Pack #7 Kit - End Pilaster to Panel to Wall, Alcove Intermediate Pilaster to Panel to Wall CEILING BOLT & FASTENER PRE-PACK KITS CB-1 ⅜ Threaded Rod With Washers and Hex Nuts CB-2 ⅜ Hex Nuts, Washers, and Trim Shoe Clips Accurate Partitions Corp. P.O. Box 287 Lyons, IL 60534 708-442-6800 Fax 708-442-7439 www.accuratepartitions.com ISMCHG01 (R00) Figure 2 Figure 3

INSTALLATION INSTRUCTIONS / STEEL PARTITIONS CEILING HUNG 4 ERECTION OF PILASTERS & PANELS 5 DOOR HANGING AND ASSEMBY a. Slide stainless steel trim over top of pilaster and leave approximately 5" down from top. b. Place washer, square spacer nut, and locking nut on one of the threaded studs. Position the slotted end of the pilaster mounting foot onto the spacer nut. This will help support the pilaster while installing the washer, square spacer nut and lock nut on the other stud. Snug both locking nuts up to the pilaster mounting foot. c. Repeat steps for remaining pilasters. d. Using a carpenters level, verify that bottoms of pilasters are level. e. Place panel between wall brackets and on adjustable support (block and wedge) approximately 12" above floor. Note any special panel requirements, example: grab bar reinforcement, accessory cut outs, etc. f. Hold pilaster so that the bottom is even with the bottom of the panel and the front edge of panel is tight to the "U" brackets. Fasten to "U" brackets with #14 x 5/8" sheet metal screws. Level panel and fasten to wall brackets. Install remaining panels. g. With cerpenters level, use leveling nuts and locking nuts to plumb pilasters so that doors openings are true. Verify door opening sizes. Make sure locking nuts are tight. h. Fasten wall pilaster to brackets using #14x 5/8" sheet metal screws. i. Slide pilaster base trim to ceiling to lock with trim clip. Figure 4b Figure 4a a. Attach top and bottom hinge brackets to pilaster with thru bolts (4-total). If pilasters were not pre-drilled at the factory, use dimensions shown in Figure 5a as a drilling (¼ bit) guide. b. Assemble cam pintle, external tooth washer, internal tooth washer, and ½ hex nut to the bottom hinge bracket as shown in Figure 5a and hand-tighten (to be wrench-tightened later). c. Insert box cam into bottom door casting as shown in Figure 5a, with short key pointing toward hinge side (edge) of door. d. Set door onto bottom hinge cam pintle. Bring door up so the top hinge casting is in line with the top hinge bracket as shown in Figure 5a. Insert the top hinge pintle and tap it down so it s flush with the top of the door. e. Set resting position of door. Hold door firmly in desired resting position (typically 20 degrees open for inswing doors and closed for outswing doors and all accessible compartment doors, regardless of swing) and wrenchtighten the ½ hex nut under bottom hinge bracket. f. Mount external plate and knob. Remove clear plastic retainer holding spring washer in place on the post of the external plate. Insert the external plate into door as shown in Figure 5b, with the shorter post inserted into the upper pocket of the internal latch mechanism. Mount the knob/handle on the inside of the door and engage it with both the center post and the shorter, off-center post of the external plate. Insert ½ shoulder screw with blue tip through the knob/handle and tighten until snug. Check for proper operation of knob and latch pin before final tightening. Figure 5a g. Locate strike/keeper on the latch-side pilaster so the latch pin engages with it when the door is closed. Drill (¼ bit) mounting holes and secure strike/keeper to pilaster using thru bolt (1), with black rubber bumper facing out for outswing doors and in for inswing doors. h. Mount coathook/bumper near center of door and 34-48 above the floor with #10 x ¾ sheet metal screws (drill holes with ⅛ bit). i. Mount door pulls with 1-¼ step bolts (drill holes with ¼ bit) to both sides of all outswing doors and accessible compartment doors, near the latch and no more than 48 above floor. Figure 5b j. Mount wall bumper for outswing doors that are hinged next to a wall using conical anchor (drill hole with ¼ bit) and 1 sheet metal screw. Figure 4c

DETAILS STAINLESS STEEL ceiling hung pilaster mounting detail 3.11 STRUCTURAL STEEL BY OTHERS LOCKING NUT WASHER WASHER LOCKING NUT WASHER LOCKING NUT THREADED ROD WASHER trim shoe clip SQUARE SPACER NUT WASHER LOCKING NUT LEVELING NUT WASHER ANCHORING SHOE BUILT INTO PILASTER WASHER LOCKING NUT STAINLESS STEEL TRIM SHOE CEILING HUNG PILASTER REV 12/04 Accurate Accurate Partitions Corp. STAINLESS STEEL CEILING HUNG PILASTER MOUNTING DETAIL NOT TO SCALE

Accurate Partitions Corp Stainless Steel Partitions with Ceiling Hung Mounting Style Specifications Stainless Steel Partitions Ceiling Hung 3.9 Part 1 - General 1.01 Work Included A. The toilet partitions shall be stainless steel with ceiling hung mounting style as manufactured by Accurate Partitions Corp, Lyons, Illinois. B. Furnish all labor and materials necessary for completion of work in this section as shown in the approved drawings and specified herein. 1.02 Related Work Specified elsewhere shall include accessories and anchorage/blocking for attachment of partitions. Part 2 Product 2.01 Door, Panels, and Urinal Screens Shall be 1 thick and fabricated from tension leveled 22 gauge, type 304 stainless steel with a #4 finish bonded to sound deadening honeycomb core. 2.02 Pilasters Shall be 1-¼ thick and fabricated from tension leveled, 18 gauge type 304 stainless steel with a #4 finish bonded to sound deadening honeycomb core. 2.03 Material - Doors, panels, pilasters, and urinal screens shall be manufactured with a resin impregnated honeycomb core that is bonded under pressure to the stainless steel with a non-toxic adhesive to ensure solid construction and sound attenuation. All the stainless steel components shall be assembled with a continuous roll-formed, interlocking, 22-gauge stainless steel crown molding welded and ground smooth at the corners. 2.04 Finish All components shall be type 304 stainless steel with a #4 finish and include a PVC film for protection during shipment and installation. 2.05 Door Hardware Shall be Accurate gravity actuated, cam-action hinges that permit door to remain at desired position when not in use. Hinges, one-piece strike and keeper and coat hook shall be chromium plated Zamac to resist corrosion. Hinges, strike and keeper shall be attached with tamper resistant barrel nuts and shoulder screws. Concealed latch assembly will allow for emergency access. Doors for handicapped compartments shall be supplied with Accurate ADA paddle handles. 2.06 Mounting Hardware Chrome plated Zamac stirrup brackets shall be used to mount panels and pilasters. Mounting hardware shall be secured with tamper resistant screws. 2.07 Construction Design - Partitions shall be ceiling hung with two 3/8 diameter zinc-plated studs that anchor the pilaster to overhead structural steel members. The ceiling anchoring system shall be concealed by a 304 type stainless steel trim shoe with a #4 finish that interlocks with the anchoring system. Part 3 Execution 3.01 Installation Shall be installed in accordance to the Accurate installation instructions with partitions rigid, straight and plumb. Doors and panels shall be mounted 12 above the finished floor. 3.02 Warranty Accurate Partitions Corp guarantees its stainless steel partitions, properly maintained, against corrosion or discoloration for 5 YEARS from the date of receipt by the customer. If material is found defective during that period, the material shall be replaced free of charge. No credits or allowances shall be issued for any labor or expenses relating to the replacement of components covered under the warranty plan. P.O. Box 287 Lyons, IL 60534-0287 (708) 442-6800 FAX (708) 442-7439

URINAL & PRIVACY SCREENS http://www.accuratepartitions.com/urinal-privacy-screens-popup Page 1 of 1 12/23/2013 CLOSE URINAL & PRIVACY SCREENS Post-Mounted 1-¾ sq. aluminum post infloor Mounted or Floor to Ceiling Mounted. Pilaster-Mounted Floor Mounted screen shown. Also available in Overhead Braced, Ceiling Hung and Floor to Ceiling. Wall-Hung Available in 3 standard heights: 42, 48,58.