ACTIVITIES AT THE STATE TIME AND FREQUENCY STANDARD OF RUSSIA

Similar documents
STABILITY AND ACCURACY OF THE REALIZATION OF TIME SCALE IN SINGAPORE

RECENT TIMING ACTIVITIES AT THE U.S. NAVAL RESEARCH LABORATORY

CALIBRATION OF THE BEV GPS RECEIVER BY USING TWSTFT

THE NATIONAL TIME AND FREQUENCY SERVICE OF THE RUSSIAN FEDERATION

BIPM TIME ACTIVITIES UPDATE

LITHUANIAN NATIONAL TIME AND FREQUENCY STANDARD

SYSTEMATIC EFFECTS IN GPS AND WAAS TIME TRANSFERS

SIMPLE METHODS FOR THE ESTIMATION OF THE SHORT-TERM STABILITY OF GNSS ON-BOARD CLOCKS

COMMON-VIEW TIME TRANSFER WITH COMMERCIAL GPS RECEIVERS AND NIST/NBS-TYPE REXEIVERS*

Inertial Navigation/Calibration/Precise Time and Frequency Capabilities Larry M. Galloway and James F. Barnaba Newark Air Force Station, Ohio

FAST DIRECT-P(Y) GPS SIGNAL ACQUISITION USING A SPECIAL PORTABLE CLOCK

THE NATIONAL TIME AND FREQUENCY SERVICE OF THE RUSSIAN FEDERATION

CCTF/06. Institute of Metrology for Time and Space FGUP "VNIIFTRI", Russia

Strategic Technical Baselines for UK Nuclear Clean-up Programmes. Presented by Brian Ensor Strategy and Engineering Manager NDA

METAS TIME & FREQUENCY METROLOGY REPORT

THE CREATION OF DIFFERENTIAL CORRECTION SYSTEMS AND THE SYSTEMS OF GLOBAL NAVIGATION SATELLITE SYSTEM MONITORING

TIME DISTRIBUTION CAPABILITIES OF THE WIDE AREA AUGMENTATION SYSTEM (WAAS)

GPS WEEK ROLL-OVER AND Y2K COMPLIANCE FOR NBS-TYPE RECEIVERS, AND ABSOLUTE CALIBRATION OF THE NIST PRIMARY RECEIVER"

National time scale UTC(SU) and GLONASS system time scale: current status and perspectives

PSEUDO-RANDOM CODE CORRELATOR TIMING ERRORS DUE TO MULTIPLE REFLECTIONS IN TRANSMISSION LINES

GLOBAL POSITIONING SYSTEM SHIPBORNE REFERENCE SYSTEM

TIME TRANSFER WITH THE GALILEO PRECISE TIMING FACILITY

ULTRASTABLE OSCILLATORS FOR SPACE APPLICATIONS

PRELIMINARY RESULTS OF THE TTS4 TIME TRANSFER RECEIVER INVESTIGATION

Report Documentation Page

Signal Processing Architectures for Ultra-Wideband Wide-Angle Synthetic Aperture Radar Applications

Best Practices for Technology Transition. Technology Maturity Conference September 12, 2007

COM DEV AIS Initiative. TEXAS II Meeting September 03, 2008 Ian D Souza

Technology Maturation Planning for the Autonomous Approach and Landing Capability (AALC) Program

RF Performance Predictions for Real Time Shipboard Applications

A HIGH-PRECISION COUNTER USING THE DSP TECHNIQUE

Two-Way Time Transfer Modem

Rump Session: Advanced Silicon Technology Foundry Access Options for DoD Research. Prof. Ken Shepard. Columbia University

INTEGRATIVE MIGRATORY BIRD MANAGEMENT ON MILITARY BASES: THE ROLE OF RADAR ORNITHOLOGY

Development of a charged-particle accumulator using an RF confinement method FA

Solar Radar Experiments

USE OF GLONASS AT THE BIPM

0.18 μm CMOS Fully Differential CTIA for a 32x16 ROIC for 3D Ladar Imaging Systems

DEVELOPMENTOFA MULTIPLE TIME SOURCECOMPARISONSYSTEMFOR DISSEMINATIVESERVICESINTAIWAN

Department of Energy Technology Readiness Assessments Process Guide and Training Plan

TWO-WAY SATELLITE TIME TRANSFER (TWSTT): USNO OPERATIONS AND CALIBRATION SERVICES

SA Joint USN/USMC Spectrum Conference. Gerry Fitzgerald. Organization: G036 Project: 0710V250-A1

A Comparison of GPS Common-View Time Transfer to All-in-View *

Durable Aircraft. February 7, 2011

DESIGNOFASATELLITEDATA MANIPULATIONTOOLIN ANDFREQUENCYTRANSFERSYSTEM USING SATELLITES

Mathematics, Information, and Life Sciences

Effects of Fiberglass Poles on Radiation Patterns of Log-Periodic Antennas

Investigation of a Forward Looking Conformal Broadband Antenna for Airborne Wide Area Surveillance

A RENEWED SPIRIT OF DISCOVERY

FAA Research and Development Efforts in SHM

Innovative 3D Visualization of Electro-optic Data for MCM

Multipath Mitigation Algorithm Results using TOA Beacons for Integrated Indoor Navigation

Loop-Dipole Antenna Modeling using the FEKO code

IREAP. MURI 2001 Review. John Rodgers, T. M. Firestone,V. L. Granatstein, M. Walter

Satellite Observations of Nonlinear Internal Waves and Surface Signatures in the South China Sea

Presentation to TEXAS II

EFFECTS OF ELECTROMAGNETIC PULSES ON A MULTILAYERED SYSTEM

Underwater Intelligent Sensor Protection System

Active Denial Array. Directed Energy. Technology, Modeling, and Assessment

REPORT DOCUMENTATION PAGE. A peer-to-peer non-line-of-sight localization system scheme in GPS-denied scenarios. Dr.

Department of Defense Partners in Flight

MERQ EVALUATION SYSTEM

UNCLASSIFIED UNCLASSIFIED 1

Ground Based GPS Phase Measurements for Atmospheric Sounding

Electromagnetic Railgun

August 9, Attached please find the progress report for ONR Contract N C-0230 for the period of January 20, 2015 to April 19, 2015.

Modeling Antennas on Automobiles in the VHF and UHF Frequency Bands, Comparisons of Predictions and Measurements

Robotics and Artificial Intelligence. Rodney Brooks Director, MIT Computer Science and Artificial Intelligence Laboratory CTO, irobot Corp

Modeling of Ionospheric Refraction of UHF Radar Signals at High Latitudes

THE TIMING ACTIVITIES OF THE NATIONAL TIME AND FREQUENCY STANDARD LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT CO. LTD.

Hybrid QR Factorization Algorithm for High Performance Computing Architectures. Peter Vouras Naval Research Laboratory Radar Division

Frequency Stabilization Using Matched Fabry-Perots as References

Wavelet Shrinkage and Denoising. Brian Dadson & Lynette Obiero Summer 2009 Undergraduate Research Supported by NSF through MAA

BIOGRAPHY ABSTRACT. This paper will present the design of the dual-frequency L1/L2 S-CRPA and the measurement results of the antenna elements.

Final Report for AOARD Grant FA Indoor Localization and Positioning through Signal of Opportunities. Date: 14 th June 2013

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION

The Energy Spectrum of Accelerated Electrons from Waveplasma Interactions in the Ionosphere

A New Scheme for Acoustical Tomography of the Ocean

THE MASTER CLOCK BUILDING AT USNO INFRASTRUCTURE

DIELECTRIC ROTMAN LENS ALTERNATIVES FOR BROADBAND MULTIPLE BEAM ANTENNAS IN MULTI-FUNCTION RF APPLICATIONS. O. Kilic U.S. Army Research Laboratory

Acoustic Monitoring of Flow Through the Strait of Gibraltar: Data Analysis and Interpretation

Rubidium-Fountain Characterization Using the USNO Clock Ensemble

Student Independent Research Project : Evaluation of Thermal Voltage Converters Low-Frequency Errors

David L. Lockwood. Ralph I. McNall Jr., Richard F. Whitbeck Thermal Technology Laboratory, Inc., Buffalo, N.Y.

Non-Data Aided Doppler Shift Estimation for Underwater Acoustic Communication

A Multi-Use Low-Cost, Integrated, Conductivity/Temperature Sensor

Modeling and Evaluation of Bi-Static Tracking In Very Shallow Water

North Pacific Acoustic Laboratory (NPAL) Towed Array Measurements

Nov.6-7,2014 DEC Workshop on Participation in Coordinated Universal Time. Aimin Zhang National Institute of Metrology (NIM)

TIME STABILITY AND ELECTRICAL DELAY COMPARISON OF DUAL- FREQUENCY GPS RECEIVERS

Management of Toxic Materials in DoD: The Emerging Contaminants Program

Experimental Observation of RF Radiation Generated by an Explosively Driven Voltage Generator

U.S. Army Training and Doctrine Command (TRADOC) Virtual World Project

Millisecond Pulsar Observation System at CRL

Marine Mammal Acoustic Tracking from Adapting HARP Technologies

TRANSMISSION LINE AND ELECTROMAGNETIC MODELS OF THE MYKONOS-2 ACCELERATOR*

Coherent distributed radar for highresolution

UNCERTAINTIES OF TIME LINKS USED FOR TAI

Radar Detection of Marine Mammals

14. Model Based Systems Engineering: Issues of application to Soft Systems

Transcription:

ACTIVITIES AT THE STATE TIME AND FREQUENCY STANDARD OF RUSSIA N. Koshelyaevsky, V. Kostromin, O. Sokolova, and E. Zagirova FGUP VNIIFTRI, 141570 Mendeleevo, Russia E-mail: nkoshelyaevsky@vniiftri.ru Abstract A campaign on the State Time and Frequency Standard modernization is continuing. A second prototype of the primary Cs fountain standard with an uncertainty of 5 10-16 is under assemblage and is scheduled to be ready by the end of 2011. Today, we have two new ensembles each of four H-masers of type CH1-75A with individual cavity auto-tuning systems. The whole instrumentation set includes distribution amplifiers, a frequency and time measuring system, and a real-time scale generation and distribution system. All these instruments are installed in thermally and humidity controlled chambers. As a result, the frequency stability of H-masers for a 1-day basis is about a few parts in 10-16. The new remote clock comparison system consists of several multichannel dual-frequenys GLONASS/GPS TTS-3 receivers. A new GLONASS/GPS/GALILEO TTS-4 receiver is expected by the end of November. All TTS-3 receivers were differentially calibrated relative to BIPM s portable receiver last year. Just now, we have completed new measurements within a new calibration campaign arranged by the BIPM. Two TWSTFT stationary stations and a transportable one were tested in VNIIFTRI last summer. VNIIFTRI is ready to join the Europe-Asia link via the AM-2 satellite when it receives a radio license. During the last year, considerable changes have happened in the secondary laboratories in Khabarovsk and Petropavlovsk Kamchatsky. The paper delivers somewhat detailed information and some preliminary results. INTRODUCTION According to metrological regulation of the Russian Federation, all technical means which transmit time signals and standard frequencies must be referred to UTC (SU) the time scale of the State Time and Frequency Standard. The GLONASS ICD specifies UTC (SU) as the reference time scale for GLONASS System Time. That s why the GLONASS modernization campaign also includes a modernization program for the State Time and Frequency Standard and a set of secondary laboratories. 41

Report Documentation Page Form Approved OMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE NOV 2010 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Activities at the State Time and Frequency Standard of Russia 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) FGUP âvniiftri,â 141570 Mendeleevo, Russia 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR S ACRONYM(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release, distribution unlimited 11. SPONSOR/MONITOR S REPORT NUMBER(S) 13. SUPPLEMENTARY NOTES See also ADA547222. Precise Time and Time Interval (PTTI) Systems and Applications Meeting (42nd Annual) Held in Reston, Virginia on November 15-18, 2010., The original document contains color images. 14. ABSTRACT A campaign on the State Time and Frequency Standard modernization is continuing. A second prototype of the primary Cs fountain standard with an uncertainty of 5ï 10-16 is under assemblage and is scheduled to be ready by the end of 2011. Today, we have two new ensembles each of four H-masers of type CH1-75A with individual cavity auto-tuning systems. The whole instrumentation set includes distribution amplifiers, a frequency and time measuring system, and a real-time scale generation and distribution system. All these instruments are installed in thermally and humidity controlled chambers. As a result, the frequency stability of H-masers for a 1-day basis is about a few parts in 10-16. The new remote clock comparison system consists of several multichannel dual-frequenys GLONASS/GPS TTS-3 receivers. A new GLONASS/GPS/GALILEO TTS-4 receiver is expected by the end of November. All TTS-3 receivers were differentially calibrated relative to BIPMâs portable receiver last year. Just now, we have completed new measurements within a new calibration campaign arranged by the BIPM. Two TWSTFT stationary stations and a transportable one were tested in VNIIFTRI last summer. VNIIFTRI is ready to join the Europe-Asia link via the AM-2 satellite when it receives a radio license. During the last year, considerable changes have happened in the secondary laboratories in Khabarovsk and Petropavlovsk Kamchatsky. The paper delivers somewhat detailed information and some preliminary results. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT SAR a. REPORT unclassified b. ABSTRACT unclassified c. THIS PAGE unclassified 18. NUMBER OF PAGES 10 19a. NAME OF RESPONSIBLE PERSON

Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18

THE PRIMARY CS FOUNTAIN STANDARDS At the last PTTI Meeting, we had reported that the first fountain primary Cs standard had successfully passed a metrological investigation and had reached an accuracy level of 3 10-15. Today, we are pleased to report that a second prototype is under assemblage. The goal is to achieve a 5 10-16 accuracy level. The present status of their mainframes, with multilayer magnetic shielding and a vacuum chamber with an RF cavity, flight zone, molasses, and detection zones, is depicted of Figure 1 a and b respectively. The multilayer magnetic shield is under assemblage and testing of the shielding factor and residual magnetic field uniformity. The vacuum chamber is under a many-day process of heating and evacuation. The whole instrument is scheduled to be ready by the end of 2011. Figure 1 (a) (b) TWO OPERATIONAL ENSEMBLES EACH OF FOUR H-MASERS IN ENVIRONMENTALLY CONTROLLED CHAMBERS Today, as a year ago, we have two specially designed climate-controlled chambers for clocks and intercomparison instruments (Figure 2). Each one contains four H-masers. A third chamber for an additional four H-masers is under construction. Two and a half years of continuous H-maser operations have given us useful information on their individual performances and allowed us to make more reliable forecasts. 42

Figure 2. A NEW CLOCK MODEL FOR TIMESCALE GENERATION The main outcome of two and a half years of data from the continuous operation of the H-maser obviously indicated that, despite comparable 1-day stability levels, the long-term performances of the clocks are considerably different, not only on the quantitative level (Figure 3). Figure 3. 43

That s why, when producing H-maser frequency forecasts for timescale generation, we were forced to apply different estimation intervals (2 or 3 months) and different powers in the polynomial model (the most typical model is third order, which includes initial time bias, initial frequency, initial frequency drift, and initial drift acceleration): x(t) = a 3 t 3 +a 2 t 2 + a 1 t 1 +a 0 t 0. As a result, for the most predictable H-masers, the RMS difference between a 1-month forecast and postprocessed data is less than 1 10-15 (Figure 4; the color palette for Figures 3 and 4 is the same). On the other hand, for the worst case, the RMS may be even a few tens of times more, for example for clock no. 1403816, according to the BIPM notation, after MJD 55200. In this case, the weight of this clock had fallen down to zero. Figure 4. THE FREE ATOMIC TIME SCALE Keeping in mind the availability of new very stable H-masers in VNIIFTRI s secondary laboratories and other laboratories in Russia, including the DoD and the Russian Academy of Science, first of all VLBI laboratories, we considered it wise to try to arrange a so-called Free Atomic Time (FAT) scale based on an ensemble of remote clocks. In many aspects, the free atomic time scale will be somewhat similar to the EAL scale produced by the BIPM. The most significant difference comparing it to the BIPM is the clock ensemble availability in VNIIFTRI. This provides a unique opportunity short-term stability (1-10 days) will be based purely on the VNIIFTRI s H-maser ensemble. The time stability for longer sample times will be based on all the available H-masers. That s why the time algorithm structure will contain two time constants. VNIFFTRI s H-maser prediction model will be fixed within 5-10 days and then the model will be updated, first of all for frequency drift and the acceleration component of the model. 44

The main goal is to improve the long-term stability of the FAT for sample times of 10-30 days up to few parts in 10-16. UPGRADING OF THE SECONDARY LABORATORIES During the last year, at least two secondary laboratories in VNIIFTRI s Far Eastern branches have been considerably updated. These are the Khabarovsk and Petropavlovsk-Kamchatsky laboratories. In Khabarovsk, the laboratory has been moved to a new building where new infrastructure has been completed. These include thermal and humidity controlled chambers for the most demanding measurement equipment, first of all the timekeeping instruments. Then the power supply scheme has been rearranged, including an uninterruptable power supply. In the second half of year two, H-masers were installed. The third one was installed at the beginning of November. The fourth one is expected in the first half of 2011. The laboratory was equipped with necessary measuring instruments and we started to install and put into operation clocks and measuring and control instruments. So today the Khabarovsk laboratory is equipped with three active H-masers in a thermally stabilized chamber, a T&F clock comparison system, a microstepper to produce real-time realization of the local UTC (Kh) time scale, and TTS3 & TTS4 time transfer systems differentially calibrated relative to the VNIIFTRI reference receiver. The equipment for the TWSTFT system has been bought and will be delivered to the Khabarovsk laboratory in the first half of 2011. In Petropavlovsk, the laboratory facilities have been completely redone. All new rooms have been equipped with a new power supply, including an uninterruptable power supply. Special thermally and humidity controlled chambers for clocks and some measurement equipment have been arranged. The main instruments installed in these rooms are: two passive H-masers, two additional Cs-beam 5071A frequency standards expected by the end of 2010, and a time and frequency distribution system and a remote clocks comparison system TTS3. NEW INSTRUMENTS AND CALIBRATION ACTIVITY IN THE OPERATIONAL TIME TRANSFER SYSTEM This year, as the year before, VNIIFTRI is taking part in the BIPM calibration campaign. Figure 5 depicts all the receivers involved. The BIPM transportable receiver TTS-3 is located at the top of the left rack. The calibration campaign is not finished yet. All the necessary measurements in VNIIFTRI will have been done, including accurate antenna coordinate determination, antenna cable delay measurement for the BIPM receiver, and proper comparison measurements within about 10 days. The following measurements have to be done at the Paris Observatory when the receiver is delivered back and then all data will be processed by the BIPM. Our preliminary results are: all VNIIFTRI s receiver internal delays regarding GPS coincide with each other within 1 ns all VNIIFTRI s receiver internal delays regarding GPS agree with the BIPM receiver within 3 ns for the previous year s results all VNIIFTRI s receiver internal delays regarding GLONASS also coincide with each other, but differ 45

from that for the BIPM receiver by about 200 ns. This value coincides with the analogous data for the previous year. The issue regarding the GLONASS delay difference is very important and has very deep roots which originate in the late 80s when time laboratories first started GLONASS monitoring. The first Western results were obtained by P. Daly, the Russian ones by G. T. Cherenkov, N. Koshelyaevsky, and S. Pushkin [1]. Since that time, the BIPM started publication of the UTC GLO ST based first on Daly s data. Then, over more than 20 years, not only receivers but laboratories have changed. Nevertheless, each new receiver has been compared with the previous one. In this way, UTC GLO ST has been kept uniform. The same situation was the case in Russia during this period, VNIIFTRI has changed its type of GLONASS time receiver three times, each time ensuring UTC (SU) GLO ST data continuity. And even now there is no accurately calibrated GLONASS time receiver. We have scheduled such work based on a new TTS4 receiver, have ordered the necessary equipment, and hope to report a result at the next PTTI. These measurements will include not only the delay in the GLO receiver s main unit itself, but all cables and antenna also. At the moment, VNIIFTRI has a temporal experimental facility and proper equipment for RF cable and antenna measurements (Figure 6), and now a special laboratory building is under construction. One more piece of good news from VNIIFTRI: This year we have gotten two stationary (Figure 7) and one portable (Figure 8) TWSTFT stations (one for VNIIFTRI; the other will be installed in the Khabarovsk branch of VNIIFTRI). All stations have SATSIM systems to monitor internal delays. As a first step, stations will use the AM2 satellite and VNIIFTRI will join in the Europe-Asia TWSTFT link. Figure 5. 46

All stations have been tested and now VNIIFTRI is waiting for a radio license, which is expected by the second half of 2011. The portable TWSTFT station provides a unique opportunity for accurate calibration of TWSTFT stationary stations, not only within Russia but also abroad. Keeping in mind that the second domestic TWSTFT station will be installed in the Far Eastern region (Khabarovsk), a calibration campaign with the laboratories in Japan, Taiwan, China and Korea looks quite feasible. Figure 6. 47

Figure 7. Figure 8. 48

REFERENCE [1] P. Daly, G. T. Cherenkov, N. B. Koshelyaevsky, and S. B. Pushkin, 1991, Satellite Time Transfer Between UTC (USNO) and UTC (SU) using NAVSTAR GPS and GLONASS, in Proceedings of the 4th International Technical Meeting (ION GPS-91), 11-13 September 1991, Albuquerque, New Mexico, USA (Institute of Navigation, Alexandria, Virginia.), pp. 199-206. ACKNOWLEDGMENTS The authors would like to express their gratitude to all their colleagues for their diligent work and expert advice on modernization of the time and frequency laboratories in VNIIFTRI and in the secondary laboratories. 49

50