PROJECT TYPE VOLTAGE POST TOP FIXTURE C4T Wave Lighting s commercial product line provides safety and security for all types of applications including parks, pedestrian walkways, and parking areas. Our Post top fixtures fit on any standard 3" diameter commercial pole (sold separately) with 3 set screws and allen wrench (provided). 2 1/2" EPA.835ft 2 WT 32lbs 27" IES FILES AVAILABLE ONLINE AT WAVELIGHTING.COM I.D. = 3" SPECIFICATIONS Cast Aluminum Housing Stainless Steel Set Screws Black, White, or Bronze Finish Acrylic Lenses Opal Drop or Frost Flat Lens Options UL Listed for Wet Locations LIGHT SOURCE OPTIONS DEDICATED LED SYSTEM - L 12-277V, 5/Hz 15W or 25W Metal Halide Equivalent Estimated 5, Hrs L 7 Surge Supression 3K, 4K, or 5K CCT 8CRI Type 5 Distribution - 1V Dimming Upon Request 5 Year Warranty GUIDE: C4TL-L4W-BK CALL FOR PHOTOMETRIC INFORMATION ITEM # LENS LIGHT SOURCE COLOR OPTIONS C4T ACRYLIC L-Opal Drop Lens FF-Frost Flat Lens LED LIGHT SOURCE DEDICATED LED SYSTEM L4-4W, 4lm L-W, lm CCT C-4K W-3K B-5K BK-Black BZ-Bronze WH-White D--1V Dimming * Special order item. Longer lead times may apply. Option not available in Replaceable Corn Cob model. Lamp Included REFER TO CATALOG FOR OPTION SPECIFICATIONS - Specifications subject to change without notice - FIXTURE SPEC 1/19 WAVE LIGHTING wavelighting.com 877-87-9283 1 of 1
Outdoor Distribution Test Report Relevant Standards IES LM-79-28, ANSI C82.77-22 Prepared For Wave Lighting LLC PO Box 3494 Saint Louis, MO 6313 United States Catalog Number C4T-L4C-BK Order Number 1277152 Test Number 1277152.1A Test Date 219-1-23 Prepared By Approved By Cordaryl Cousar, Technician Alexa Lambert, Project Handler The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Underwriters Laboratories. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Test Number 1277152.1A - Page 1 of 5
Luminaire Description: Lamp: Mounting: Ballast/Driver: Black aluminum housing, frosted lens enclosure 24 white LEDs Post Inventronics EUC-42S15Ds Luminaire Luminaire Characteristics Luminous Diameter: 16. in. Summary of Results Roadway Classification: Type V, Very Short Cutoff Classification: Full Cutoff BUG Rating: B1 U G1 Test Conditions Test Temperature: 24.7 Voltage: Current: 12..3526 Power: 41.98 Power Factor:.992 Frequency: Current THD: 7.15 C VAC A W Hz % Tested in 3 planes left side, 3 planes right side, left and right averaged Vertical test increments are 2.5 degrees Test distance exceeds five times the greatest luminous opening of luminaire Laboratory results may not be representative of field performance Ballast factors have not been applied Test Number 1277152.1A - Page 2 of 5
Distribution - Goniophotometer Distribution Test Conditions Temperature Voltage Current Power Power Factor Frequency Current THD 24.7 C 12. VAC.3526 A 41.98 W.992 Hz 7.15 % IES Roadway Classification: Cutoff Classification: BUG Rating: Summary of Results Type V, Very Short Full Cutoff B1 U G1 Total Lumen Output: Luminaire Efficacy: Maximum Candela: ISO FootCandle Plot at 2 Feet 2447 Lumens 58.3 lm/w 932 Candela Ratio of Transverse Distance to Mounting Height Ratio of Longitudinal Distance to Mounting Height -1 1 2 3 4 5 6 1 2 3 Insert ISO Plot 4 5 6 7 <-------------Type I---------------><-Type II-><---Type III---><---------------------Type IV----------------------------> <-------------------------Long-------------------------><-------Medium-------><-----Short-------><-Very Short- Half Max Intensity Max Intensity 2 fc 1 fc.5 fc.2 fc.1 fc Series15 Test Number 1277152.1A - Page 3 of 5
9 12 Maximum Plane and Cone Plots of Candela 18 1 15 9 15 8 7 5 4 3 2 1 12 9 3 3 Vertical Plane Through Lateral Lateral Cone Through 22.5 Vertical Maximum Intensity (Candlepower): 932 Candela Zonal Lumen Summary Zone Lumens % of Luminaire Zone Lumens % of Luminaire Zone Lumens % of Luminaire -5 14.9.6% -65 131.6 5.4% 12-125..% 5-1 51.6 2.1% 65-7 11.9 4.2% 125-13..% 1-15 1.7 4.1% 7-75 73.8 3.% 13-135..% 15-2 15.4 6.1% 75-8 48.3 2.% 135-14..% 2-25 194.9 8.% 8-85 26.4 1.1% 14-145..% 25-3 23.2 9.4% 85-9 8.7.4% 145-15..% 3-35 249.6 1.2% 9-95..% 15-155..% 35-4 251.2 1.3% 95-1..% 155-1..% 4-45 239.5 9.8% 1-15..% 1-165..% 45-5 218.9 8.9% 15-11..% 165-17..% 5-55 192. 7.8% 11-115..% 17-175..% 55-162.2 6.6% 115-12..% 175-18..% Test Number 1277152.1A - Page 4 of 5
IES "BUG" Rating (Back Light, Uplight, Glare) Per IES TM-15-11 Luminaire Classification System (LCS) LCS Zone Lumens Luminaire % FL (-3) 371.4 15.2% FM (3-) 656.7 26.8% FH (-8) 177.8 7.3% FVH (8-9) 17.6.7% BL (-3) 371.4 15.2% BM (3-) 656.7 26.8% BH (-8) 177.8 7.3% BVH (8-9) 17.6.7% UL (9-1)..% UH Total (1-18). 2446.8.% 1.% BUG Rating B1 U G1 Test Number 1277152.1A - Page 5 of 5
Chromaticity Coordinates Chromaticity (x).337 Chromaticity (y).3477 Chromaticity (u).274 Chromaticity (v).321 Chromaticity (u').274 Chromaticity (v').4816 Catalog Number C4TFF-LC-BK Electrical Test Conditions Temp Voltage Current Power Power Factor Frequency Current THD 25.8 C 12. VAC.5581 A 66.8 W.997 Hz 5.51 % Summary of Results ISO FootCandle Plot at 2 Feet Intensity Through Maximum Plane Total Lumen Output 3245 Lumens Ratio of Transverse Distance to Mounting Height -1 1 2 3 4 5 6 (Candlepower) Luminaire Efficacy 48.7 lm/w Maximum Candela Candela Angle Candlepower Lumens IES Roadway 1 Half Max 839 Type V, Very Short Intensity Classification 5 93 94 Max Cutoff Classification Cutoff Intensity 1 176 BUG Rating 2 B2 U1 G1 2 fc 15 1187 337 CCT 538 K 2 1257 3 1 fc CRI 75.1 25 1269 58 Duv.11 Insert ISO Plot.5 fc 3 124 TM-3 Rf 73. 4 35 177 67 TM-3 Rg 96..2 fc 4 928 45 775 597.1 fc 5 Luminaire Classification System 5 629 (LCS) 55 496 445 LCS Zone Lumens % 6 379 65 28 28 FL (-3) 56 16% 7 7 197 FM (3-) 856 27% 75 126 135 <-------------Type I---------------><-Type II-><---Type III---><---------------------Type IV------------------------- FH (-8) 28 7% 8 67 FVH (8-9) 16 1% Maximum Maximum Plane and Cone Plots of Plots Candelaof Candela 85 25 32 18 BL (-3) 56 16% 9 9 14 BM (3-) 856 27% 95 7 15 15 12 BH (-8) 28 7% 1 5 8 BVH (8-9) 16 1% 1 15 2 2 UL (9-1) 8 % 8 11 12 12 UH (1-18) 2 % 115 12 4 Color Rendering Index Details 125 Ra (CRI) 75.1 2 13 9 9 R1 73.8 135 R2 78.8 14 R3 81.4 145 R4 76.4 15 R5 74.5 155 R6 71. 1 R7 82.2 165 3 3 R8 63. 17 R9-12.5 Vertical Plane Lateral Cone 175 R1 48.5 Lateral 22.5 Vertical 18 R11 74.2 R12 5.7 R13 74 1. Flux vs Wavelength Nominal CCT Quadrangles.46 R14 89.3 8..44 Ratio of Longitudinal Distance to Mounting Height. 4. 2.. 35 4 45 5 55 65 7 75 8 85 Wavelength (nm) Testing was performed in accordance with LM-79-8 The results contained in this summary pertain only to report #1269771 <-------------------------Long-------------------------><-------Medium-------><-----Short-------><-Very Short-> Spectral Flux (mw/nm).42.4.38 y.36.34.32.3 57K 5K 41K 45K 35K 3K 27K Inside Quad 57 K.28.3.35.4.45.5 x
Ratio of Longitudinal Distance to Mounting Height <-------------------------Long-------------------------><-------Medium-------><-----Short-------><-Very Short-> Wave Lighting LLC Catalog Number C4TL-LC Your Logo Here Electrical Test Conditions Temp Voltage Current Power Power Factor Frequency Current THD 25.2 C 12. VAC.5462 A 65.3 W.996 Hz 5.71 % Summary of Results ISO FootCandle Plot at 12 Feet Intensity Through Maximum Plane Total Lumen Output 1613 Lumens Ratio of Transverse Distance to Mounting Height -1 1 2 3 4 5 6 (Candlepower) Luminaire Efficacy 24.7 lm/w Maximum Candela 249 Candela Angle Candlepower Lumens IES Roadway 1 Half Max 183 Type V, Very Short Intensity Classification 5 18 18 Cutoff Classification Noncutoff Max Intensity 1 24 2 BUG Rating B1 U3 G1 15 23 65 1 fc 2 245 3 25 248 114.5 fc Insert ISO Plot 3 249 4 35 249 156.2 fc 4 248.1 fc 45 244 188 5 Luminaire Classification System 5 236 (LCS) 55 227 24 LCS Zone Lumens % 6 218 65 27 25 FL (-3) 99 6% 7 7 195 FM (3-) 274 17% 75 183 193 <-------------Type I---------------><-Type II-><---Type III---><---------------------Type IV---------------------------- FH (-8) 199 12% 8 169 FVH (8-9) 84 5% Maximum Maximum Plane Plane and Cone Plots Plots of Candela of Candela 85 154 168 BL (-3) 99 6% 18 9 138 25 BM (3-) 274 17% 95 121 132 15 15 BH (-8) 199 12% 2 1 13 BVH (8-9) 84 5% 15 85 91 15 UL (9-1) 132 8% 11 69 12 12 UH (1-18) 169 1% 115 53 1 12 37 53 5 125 24 22 13 12 9 9 135 4 4 14 145 15 155 1 165 3 3 17 Vertical Plane Lateral Cone 175 Lateral 35 Vertical 18 Testing was performed in accordance with LM-79-8 The results contained in this summary pertain only to report #1214114.1