THE ANNALS OF DUNAREA DE JOS UNIVERSITY OF GALATI FASCICLE III, 2006 ISSN X ELECTROTECHNICS, ELECTRONICS, AUTOMATIC CONTROL, INFORMATICS

Similar documents
5DESIGN PARAMETERS OF SHUNT ACTIVE FILTER FOR HARMONICS CURRENT MITIGATION

Application of Fuzzy Logic Controller in Shunt Active Power Filter

HYSTERESIS CONTROL FOR CURRENT HARMONICS SUPPRESSION USING SHUNT ACTIVE FILTER. Rajesh Kr. Ahuja

A Novel Fuzzy Variable-Band Hysteresis Current Controller For Shunt Active Power Filters

Power Factor Pre-regulator Using Constant Tolerance Band Control Scheme

Novelty Technique for Power factor Improvement by a Single phase Rectifier

Researches Regarding the Pollution with Harmonics by the Frequency Converters

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

ON THE TRANSIENTS OPTIMIZATION AND THE POWER FACTOR CORRECTION OF THE STATIC CONVERTERS

Chapter 2 Shunt Active Power Filter

A Predictive Control Strategy for Power Factor Correction

Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory

ISSN Vol.03,Issue.07, August-2015, Pages:

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

COMPENSATION OF POWER QUALITY PROBLEMS USING ACTIVE POWER FILTER

A Modified Direct Power Control Strategy Allowing the Connection of Three-Phase Inverter to the Grid through LCL Filters

A MATLAB Model of Hybrid Active Filter Based on SVPWM Technique

POWER FACTOR CORRECTION AND HARMONIC CURRENT REDUCTION IN DUAL FEEDBACK PWM CONTROLLED AC/DC DRIVES.

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Reactive Power Compensation of LC Coupling Hybrid Active Power Filters by DC Link Voltage Controls

Literature Review for Shunt Active Power Filters

CHAPTER 5 MODIFIED SINUSOIDAL PULSE WIDTH MODULATION (SPWM) TECHNIQUE BASED CONTROLLER

Power Quality improvement of a three phase four wire system using UPQC

ISSN Vol.03,Issue.42 November-2014, Pages:

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

SHUNT ACTIVE POWER FILTER

2020 P a g e. Figure.2: Line diagram of series active power filter.

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

Design and Simulation of PFC Circuit for AC/DC Converter Based on PWM Boost Regulator

Exploration in Power Quality Furtherance on Shunt Active Power Filter

Harmonics Reduction using 4-Leg Shunt Active Power Filters

Three-Level Shunt Active Filter Compensating Harmonics and Reactive Power

A Hysteresis based Active Shunt, Passive Series Hybrid Filter for Power Quality Improvement

Modeling & Simulation of Micro Grid Distribution System to reduce Harmonics Using Active Power Filters and PI controllers

e-issn: p-issn:

ATYPICAL high-power gate-turn-off (GTO) currentsource

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

Kanuru; Krishna (Dt); A.P, India. DOI: / Page. 1 G. Aruna Jyothi, 2 DR. P. V. R. L.

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

Size Selection Of Energy Storing Elements For A Cascade Multilevel Inverter STATCOM

Mitigation of Current Harmonics with Combined p-q and Id-IqControl Strategies for Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter

Direct Power Control With Space Vector Modulation And Fuzzy DC- Voltage Control- PWM rectifier

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

Modeling and Simulation of Paralleled Series-Loaded-Resonant Converter

EXPERIMENTAL STUDY OF THE POWER FACTOR COMPENSATION CONVERTER

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

Indirect Current Control of LCL Based Shunt Active Power Filter

A New Quadratic Boost Converter with PFC Applications

Current Rebuilding Concept Applied to Boost CCM for PF Correction

TRADITIONALLY, passive filters have been used

PERFORMANCE EVALUATION OF THREE PHASE SCALAR CONTROLLED PWM RECTIFIER USING DIFFERENT CARRIER AND MODULATING SIGNAL

SHUNT COMPENSATOR USED FOR POWER QUALITY IMPROVEMENT

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

CHAPTER 6 ANALYSIS OF THREE PHASE HYBRID SCHEME WITH VIENNA RECTIFIER USING PV ARRAY AND WIND DRIVEN INDUCTION GENERATORS

A Review on Improvement of Power Quality using D-STATCOM

A Comparative Study between DPC and DPC-SVM Controllers Using dspace (DS1104)

A Control Scheme Research Based on Sliding Mode and Proportional-Integral Control for Three-phase Rectifier

Power Quality Improvement using Shunt Passive Filter

CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER

Fuzzy Logic Controller Based Three-phase Shunt Active Filter for Line Harmonics Reduction

Control methods for PWM rectifier cooperating with variable speed PM generator

Generation of Voltage Reference Signal in Closed-Loop Control of STATCOM

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Hysteresis Controller and Delta Modulator- Two Viable Schemes for Current Controlled Voltage Source Inverter

Three Phase Active Power Filter Based on Current Controlled Voltage Source Inverter

Nonconventional Technologies Review no. 4/2009

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

Vol. 1, Issue VI, July 2013 ISSN

Using dspace in the Shunt Static Compensators Control

Improvement of Power Quality Using a Hybrid Interline UPQC

A Static Synchronous Compensator for Reactive Power Compensation under Distorted Mains Voltage Conditions

ISSN: Page 20. International Journal of Engineering Trends and Technology- Volume2Issue3-2011

SIMULATION AND COMPARISON OF SPWM AND SVPWM CONTROL FOR TWO LEVEL UPQC

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

CHAPTER 4 DESIGN OF DC LINK VOLTAGE CONTROLLER FOR SHUNT ACTIVE POWER FILTER

SINGLE PHASE BRIDGELESS PFC FOR PI CONTROLLED THREE PHASE INDUCTION MOTOR DRIVE

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

CURRENT HARMONICS REDUCTION IN 3 PHASES 4 WIRE SYSTEM USING HYBRID FILTERS R.Saravanakumar 1#, S.Amritha 2#

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

THREE PHASE RECTIFIER TOPOLOGY WITH PRACTICALLY SINUSOIDAL INPUT CURRENTS

Experimental Results of a Single-Phase Shunt Active Filter Prototype with Different Switching Techniques

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

A Novel FPGA based PWM Active Power Filter for Harmonics Elimination in Power System

Improving the Power Quality by Four Leg VSI

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

CHAPTER 4 MULTI-LEVEL INVERTER BASED DVR SYSTEM

Comparison of Reference Current Extraction Methods for Shunt Active Power Filters

ABSTRACT I. INTRODUCTION

Reactive power compensation for linear and non linear loads by using active and passive filter for smart grid applications.

Fuzzy Logic Control of APF for Harmonic Voltage Suppression in Distribution System

IMPROVING EFFICIENCY OF ACTIVE POWER FILTER FOR RENEWABLE POWER GENERATION SYSTEMS BY USING PREDICTIVE CONTROL METHOD AND FUZZY LOGIC CONTROL METHOD

Power Quality Improvement of Non-Linear Load by Using Instantaneous P-Q Theory

Implementation of a low cost series compensator for voltage sags

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Assessment of Different Compensation Strategies in Hybrid Active Power Filters

Transcription:

EECTOTECHNICS, EECTONICS, AUTOMATIC CONTO, INFOMATICS INDIECT CONTO OF A SINGE-PHASE ACTIVE POWE FITE Emil osu, Mihai Culea, Teodor Dumitriu, and Traian Munteanu Dunarea de Jos University, Galati, omania Abstract: The control of shunt active power filters using PWM inverters consists in generating a reference by separating, using different methods, the harmonics to be eliminated. The methods used are time-consuming and need dedicated control and signal processing equipments. To avoid these setbacks a new method is proposed in the paper. The active power filter is a current PWM rectifier with voltage output and with a capacitor on the DC side. The PWM rectifier is controlled so that the sum of its current and the load s current is a sinusoid. The control block as well as simulation results are presented. Keywords: Active power filters, PWM rectifiers, hysteresis control, THD. 1. INTODUCTION The classical structure of a single phase APF using a voltage inverter is presented in Fig. 1, where SD is a non-linear load. The APF is injecting a current so that the total current drawn from the mains or the filtering of the components. Several other methods are presented in literature but they are usually application oriented. u (1) i () t = i () t i () t S F is sinusoidal and the voltage and current phases are identical. i i S i F + C - u c The APF s current is 1 (2) i () t = i% () t = i () t i () t F S S S where i 1 S () t is is the fundamental and i% S () t is the sum of higher order harmonics, often named the polluting component. Separation of the polluting current component from the fundamental is a rather complicated procedure. In (Ionescu, et all, 1998) some of these methods are presented, such as the instantaneous powers method SD APF Fig.1. APF structure. A new approach, called indirect control, is presented. The application does not need a prior knowledge of the non-linear load s current spectrum. The schematic of the system is presented in Fig. 2. Unlike the classical structure, the supply of the load and of the APF is done through the inductor in a structure specific to PWM current rectfier with voltage output. This paper was recommended for publication by Emil Ceanga 94

u the mains voltage (9) ut () = 2Usin( ωt) i i F u i (t) + - C u c and the total drawn current (10) i () t = 2I sin( ωt) i S I ϕ U jω I Fig.2. Indirect control structure. The current drawn from the mains is (3) i () t = i () t + i ( t) S F To obtain a sinusoidal form the curren t drawn by the rectifier should be 1 (4) i () t = i () t +% i () t F F F where i 1 F () t is the fundamental current used to keep the capacitor C charged while for the harmonic components of the current the following holds out (5) i% () t + i% () t = i() t F where it () is the fundamental in phase with the mains voltage. By using (3), (4), and (5) the total drawn current is (6) i () t = i () t + i () t + i() t The sum of the current drawn by the rectifier and the load is a sinusoidal current at the point of common coupling in phase with the voltage. Considering the structure of the PW M control i () t will contain a minimum higher order harmonics while keeping the phase shift to a minimum. Different control strategies, such as open-loop sinusoidal PWM, open or closed loop hysteresis control can be used. The amplitude modulation index m A has to be determined for the sinusoidal PWM control following S 1 1 F S 2. CONTO STATEGIES (7) m A = 2U U C where the input voltage of the PWM rectifier is (8) u () t = 2U sin( ωt+ ϕ) i SD i i Fig.3. Phasor diagram. This can be re presented on a phasor diagram as in Fig.3. By using linear modulation, ma 1, the boost characteristic of the rectifier is obvious and the phase is (11) arctg ωi ϕ = U The MS value of the current is determined based on the sum of active powers which can be written as 1 UC (12) UI. = UI. S + CU. C T where UC and T are the capacitor voltage ripple and period. From (12) it can be observed that the capacitor voltage can be determined and the MS of the load current has to be determined, which is a major setback. Moreover, for any change in the load the MS has to be recalculated. For the open-loop hysteresis control the problem is similar but the MS value to be calculated is for I. The closed loop hysteresis control is presented in Fig. 4. U c UC ε U -i PWM c sin ( ω t) Fig.4. Control structure. The choice of U C as a controlled value is determined by the boost characte ristics of the rectifier which determined by the value of the U i produces variations of the output. The error of the output voltage is transformed into a reference for the input current (13) i * = ε.sin( ωt) U i HC i which has the same phase as the mains voltage. The current is controlled using a hysteresis controller HC 95

having an acceptable hysteresis band relating to the current ripple and switching frequency. 3. SIMUATION MODE To validate the proposed control scheme the model presented in Fig. 5 was used. A single phase rectifier with a capacitive filter was considered due to the fact that it is highly non-linear. The input voltage and current are presented in Fig. 6 for the case of a 1000µ F capacitor, a 10mH inductor filter and a 10Ω load. The THD coefficient of the current is 28.27 %. U i APF Fig.7. Input current and voltage, U C =110V U i i F C1 U c i S C2 Uc Fig.5. Simulation model. 4. EXPEIMENTA ESUTS The model was used to simulate, via SIMUINK, different conditions, taking into account the dynamic of the system, THD coefficient and the output voltage. The mains voltage and current variations are presented in Fig. 7 for a reference of 110V for the output voltage. The dynamic response has about two periods and the THD is reduced to 3.54% while the ripple is very small. Fig.8. U C and U C voltages, U C =110V Fig.6. Uncontrolled rectifier current and voltage Fig.9. Filter and load currents, U C =110V 96

for the filter used. The input currents filter and load, are presented in Fig. 9. Fig.10. Input current and voltage, U C =130V Fig.13. U C and U C voltages, U C =80V Fig.11. U C and U C voltages, U C =130V Fig.14. Input current and voltage Fig.12. Input current and voltage, U C =80V The output voltages for the PWM rectifier and the load have the same average value of 110V since they are b oth powered from the same supply, ui () t, and are presented in Fig. 8. They also outline the boosting characteristic of the rectifier, the output of the load being higher than usual. The voltage ripple is typical Fig.15. U C and U C voltages 97

The influence of the PWM rectifier and hysteresis control can be noticed on the first half of a semi- when usually the current of the load rectifier is period zero. In the second half of the semi-period when the current is sinusoidal, the APF does not work as the PWM rectifier, but it is functioning as an uncontrolled rectifier. There is also a supplementary conduction through the uncontrolled rectifier, determined by the variation of ui () t and the boosting character of the ensemble. While the oscillations of the currents are important, they don t appear in the input current or in the output voltages. A second simulation test was carried out for a 130V reference. The results are presented in Fig. 10, the input voltage and current, and in Fig. 11, the output voltages. The same conclusions apply and THD = 3.3%. The third simulation test, Fig.12 and 13, was done using a 80V reference, for an amplitude modulation coefficient (14) m A = 2U i 2U 100 1 U U = 80 > C The output voltages follow the reference as expected, but there are larger values for the higher harmonics and THD = 8.73 %. This behaviour is determined by the over-modulation which induced nonlinearities in the control. The fourth test also considered the variation of the load from 20Ω to 10Ω at t=0.1 sec. The input current and voltage are presented in Fig. 14 and the output voltages in Fig. 15. There are two differences, as for the 20Ω load the PWM is extended to a semiperiod due to a reduced current, while for the 10Ω load the operation is similar to the one presented afore. The output voltages follow the reference after a short transient regime. An interesting behaviour can be observed when the supply voltage u(f) is distorted with 5 th and 7 th harmonic. This can be written as: ut ( ) = 2U1sin(100 πt) + 2U5sin(500 πt) + (15) 2U sin(700 πt). 7 Simulations were carried out for different values of supply voltage THD factor and the results are presented in Table I. For small THD factors there is an decrease of the THD which can be explained based on the 5th and 7th harmonics drawn by the nonlinear load. For large values of the mains voltage THD the current is also distorted, the THD factor beeing almost double which indicates the limitations of the method. However, this case is unlikely to be a real one, since such large values for the THD are uncommon. Mains voltage variations are presented in figure 16 as well as the current drawn from the mains, illustrating the second case presented in Table I C Table 1 The influence of mains voltage THD on the behaviour of the APF 2U 1 2U 5 2U 7 THD u THD i 100 7 5 8.6 % 3.20 % 100 10 7 12.2% 3.44 % 100 20 10 22.36 % 8.72 % Fig.16. Input current and voltage The dynamic of the system is tested by switching from a sinusoidal to a distorted mains voltage. A distorted voltage is applied at t=0.8 sec and the system is responding instantaneously, as it can be seen from the THD of the current, showing robustness to mains voltage distortions. Fig.17. Input current and voltage Simulations were also carried out to evaluate the influence of the voltage amplitude variation on the system. A 5% voltage drop did not influence the output voltage U C which kept the 110V reference value, while the output of the PWM inverter is not significantly influenced as in fig.18. Therefore the proposed system has also a voltage control effect due to the closed loop control. 98

A ± 0.5A hysteresis band was considered for the current control, leading to a switching frequency of up to 5 khz. educing the hysteresis band will indeed reduce the THD but the improvement is limited and determines an increase of the switching frequency 5. CONCUSIONS Fig.18. U C and U C voltages The simulated results prove that the proposed structure is operating accordingly. The substantial decrease of the THD recommends the solution as a viable option with good performances. The solution can also be applied for controlled rectifiers which will allow the control of the output voltage. The main drawback is the presence of the inductor of relatively large value that depends on the output voltage; however, this also applies to all the other APF structures. The inductor has to be designed to withstand the currents from the rectifier and also the PWM rectifier. The solution can also be applied to three-phase rectifiers since the harmonics are greatly reduced. 6. EFEENCES H. Akagi, New Trends in Active Filters for Power Conditioning, IEEE Transactions, 1996, IA-32. F. Ionescu, S. Nitu, E. osu, Preocupari actuale in domeniul electronicii de putere, Editura SECOEX, ISBN 973-85298-3-2, Bucuresti 2001. F. Ionescu, D. Floricau, S. Nitu, J.P.Six. Ph. Delarue, C. Bogus, Electronica de putere. Convertoare statice, Editura Tehnica, ISBN 973-31-1262-3, Bucuresti 1998. T. E. Nunez-Zuninga and J.A. Pomilio, Shunt Active Power Filter Synthesizing eisitive oads, IEEE Transactions in Power Electronics, vol.17, No 2, March 2002. Fig.19. oad and capacitor C 2 currents An important issue is the shape of the current i () t drawn by the nonlinear load SD, given by: S (16) i () t = i () t + i () t S C2 where i () t is the load current and ic 2 () t is the current passing through the filtering capacitor. The currents are presented in figure 19. The load current is not influenced by the PWM control but the filtering capacitor is oversolicited by the high order harmonics generated by the PWM rectifier. The controller for the output voltage, UC, is a PI controller with an experimental parameters adjusting.. 99