FF-SRE609 Extension Module FF-SR Series FEATURES Complies with the Machinery Directive 98/3/EC Meets the applicable parts of the US & Canadian regulations and standards ANSI/RIA/OSHA Redundant and positive-guided contacts Output: four NO contacts and two NC contacts LED indicates status of internal relays Very high mechanical and electrical lifetime Switching current from 0 ma to A Slim housing width, mm / 0.89 in TYPICAL APPLICATIONS Contact multiplication of safety devices with the External Device Monitoring capability, like - FF-SYB and FF-SB safety light curtains - FF-SR safety control modules - FF-SM safety mats Suitable for interfaces up to Category 4 per EN 94- The FF-SRE609 Extension Module provides contact multiplication for safety devices with External Device Monitoring (EDM) capability (e.g. FF-SRS e-stop modules, FF-SYB, and FF-SB light curtains, FF-SM safety mats). This product has two safety relays with positive-guided contacts to ensure redundancy and offers four NO and one NC safety contact. Its slim housing of only, mm (0.89 in) width allows this safety control module to fit into most cabinets and even helps to keep the overall cabinet size small. New! WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet (or catalogue) is for reference only. DO NOT USE this document as system installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury.
FF-SRE609 Extension Module SPECIFICATIONS Contact multiplication of safety devices with EDM capability Suitable for interfaces up to Category 4 per EN 94- Input Nominal voltage 4 Vac (-0 %, + 0 %), 4 Vdc (-0 %, +0 %) Nominal consumption ac: 3,4 VA dc:, W Nominal frequency 0 Hz to 60 Hz Output Contacts 4 NO, NC (plus NC for External Device Monitoring Loop) Contact type Safety relay, positive-guided Response time max. 3 ms (delay on de-energisation) Delay on energisation max. 0 ms Switching capability Power factor = with resistive load Current range (min. to max.) 0 ma to A Voltage range (min. to max.) 0, to 0 Vac Switching capability NO contact : 3 A / 30 Vac per AC (EN 6094--) NC contact : A / 0 Vac Typical Electrical Life Expectancy Power factor = at 30 Vac (see Figure, note ) Current Operations Current Operations 0, A 00 000 A 000 000 A 000 000 A 0 000 Typical Power Factor (cos ϕ) Limitation factor F (see Figure, note ) Cos ϕ F Cos F 0,3 0,4 0, 0,8 0, 0, Operating frequency 00 operating cycles/h Fuse rating 6 A time delayed (max.) Mechanical life 0 000 000 operating cycles General Temperature range - C to + C ( F to 3 F) at 90% humidity (max.) Sealing Housing: IP 40 Terminals: IP 0 Housing material Thermoplastic Vibration resistance (IEC/EN 60 068--6) Amplitude: 0,3 mm Frequency: 0 to Hz Wire connection Solid wire: x 4 mm [ AWG] or x, mm [4 AWG] Stranded wire with sleeve: x, mm [4 AWG] or x, mm [6 AWG] Wire/conductor attachment M3, screw terminals Mounting Quick install rail mounting IEC/EN 60 (width: 3 mm/.38 in) Weight 0 g / 0.4 lb ORDERING INFORMATION Note : Install arc suppressors across load to avoid module contact arcing and ensure specified contact life expectancy. Note : Total operations = operations (power factor ) x limitation factor F. Example: U = 30 Vac, I = A, power factor cos ϕ = 0, Switching power P = U x I = 30 Vac Contact life (cos ϕ =, P = 30 VA) = 000 000 operations (see Figure ) Limitation factor F (cos ϕ = 0,) = 0, (see Figure ) Contact life (cos ϕ = 0,, P = 30 VA) = F x contact life (cos ϕ = 0,, P= 30 VA) = 000 000 x 0, = 400 000 operations. FIGURE. TYPICAL CONTACT LIFE FOR 00 % RESISTIVE LOAD (power factor cos ϕ =, note ) Operations 0 3 3 0 6 0 0,,0,,0 Switching power [kva] Limitation factor F 0,9 0,8 0, 0,6 0, 0,4 0,3 FIGURE. LIMITATION FACTOR FOR INDUCTIVE LOADS (power factor cos ϕ <, note ) 0, 0, 0,4 0,6 0,8 Power factor
INSTALLATION DIAGRAM MOUNTING DIMENSIONS Width:, mm / 0.89 in; Height: 90 mm / 3. in Depth: mm / 4.6 in a b INTERNAL CIRCUITRY TERMINAL ARRANGEMENT A A(-) 3 3 33 43 Y A A (-) 3 3 33 43 4V K 4V K Rail FF-SRE609 3 3 33 43 Y K K 4 4 34 44 Y 4 4 34 44 A3 A4(-) 4 4 34 44 Y A3 A4 Y Y M86 (-) c 3
APPLICATION EXAMPLES Connection of an FF-SRS93 emergency stop module 4 Vdc Fuse Emergency stop push-button (A) (A) 0 Vdc A A (-) Power K K3 S S S S S S33 S34 Internal Switches Restart pushbutton 3 3 33 4 FF-SRS93 S PE 4 4 34 4 NO and NC safety contacts A A (-) A3 A4 (-) 4 3 3 FF-SRE609 K K 33 43 4 34 44 Machine control 4 NO and NC safety contacts After activation of the safety device (see application note (A)), the normally open safety contacts of the FF-SRS93 dual channel emergency stop module (3/4 to 33/34) and the connected FF-SRE609 extension module (3/4, 3/4, 33/34, 43/44) will open. The normally closed contacts (4/4, /) will close. The LED relay output indicators (K, K3 and K, K) of both modules go off indicating that the internal safety relays are de-energized. After removing the emergency stop condition, press and release the restart push-button to restart the FF-SRS93 emergency stop module. If the FF-SRE609 extension module is operating properly, the normally closed contact (Y/Y) for the External Device Monitoring is closed and both safety modules are energising their internal safety relays. The normally open contacts will close and the normally closed contacts will open. The LED relay output indicators all illuminate. This action will allow the machine to operate. Y Y APPLICATION NOTES: Note (A): Dual channel output safety devices with relay outputs or safety switches (examples) emergency stop push-button safety light curtains (FF-SB, FF-LS), single beam (FF-SPS4), modular safety light curtains (FF-SCAN), safety mats (FF-SM) safety limit or interlock switches (e.g. CPS, GK, GSS) 4
Connection of an FF-SYB type 4 safety light curtain (+4 Vdc) Fuse Optional reset P/B Restart / EDM Towards PLC input (0 Vdc) Optional test input 4 (-) FF-SYB emitter FF-SYB Receiver (A) OSSD (B) OSSD 3 6 Rec M O NB P #0 M : Manual O : NC output NB: No blanking 8 A A (-) A3 A4 (-) 4 3 3 Dual channel machine control circuit (recommended circuit) 33 43 FF-SRE609 K K 4 34 44 After interrupting the sensing field of the FF-SYB safety light curtain, both static safety oututs (, 6) of the receiver switch off. Then, the normally open contacts of the connected FF-SRE609 extension module (3/4, 3/4, 33/34, 43/44) will open and the normally closed contacts (/, Y/Y) will close. The LED relay output indicators (K, K) of the module go off indicating that the internal safety relays K and K are de-energized. After clearing the sensing field of the FF-SYB safety light curtain, press and release the restart push-button to restart the receiver. If the FF-SRE609 extension module is operating properly, the normally closed contact (Y/Y) for the External Device Monitoring (EDM) is closed and the static safety outputs of the FF-SYB receiver are energising. The normally open contacts of the FF-SRE609 module will close and the normally closed contacts will open. The LED relay output indicators K and K illuminate. This action will allow the machine to operate. APPLICATION NOTES: Note (A): Dual channel output safety devices with static safety outputs AND External Device Monitoring (EDM) function (e.g. FF-SYB safety light curtains). Note (B): CONFIGURATION CARDS Various mode settings are possible with the FF-SYB safety light curtain (e. g. start / restart, muting, floating blanking) using configuration cards. The example above uses the factory setting configuration card for the receiver (#: manual start, no muting, no blanking). Refer to the FF-SYB installation manual for more information. Y Y
Warranty and remedy warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to during the period of coverage, will repair or replace without charge those items it finds defective. The foregoing is Buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. While we provide application assistance, personally, through our literature and the web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change at any time without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Sales and Service serves its customers through a worldwide network of sales offices and distributors. For application assistance,current specifications, pricing or name of the nearest Authorised Distributor, contact a nearby sales office or: INTERNET: www.honeywell.com/sensing E-mail: info.sc@honeywell.com ASIA PACIFIC New Zealand Limited Control Products Phone: +(64-9) 63-00 Asia Pacific Headquarters Phone: Fax: +(64-9) 63-060 +(6) 63-88 Toll Free (0800) 0-088 Fax: +(6) 644-3033 Australia Limited Phone: +(6) -930-400 Fax: +(6) -930-4 Toll Free 300-36-39-36 Toll Free Fax: 300-36-04-0 China - PRC - Beijing China Inc. Phone: +(86-0) 848-380 Fax: +(86-0) 848-30 China - PRC - Shanghai China Inc. Phone: (86-) 63-03 Fax: (86-) 63-3 China - Hong Kong S.A.R. Ltd. Phone: +(8) 93-64 Fax: +(8) 93-66 Indonesia Indonesia Pte Ltd. Phone: +(6) -3-8833 Fax: +(6) -36-008 India TATA Ltd. Phone: +(9) 0 68 044/0446 Fax: +(9) 0 68 43/68 99 Japan Inc Phone: +(8) 3 440 4 Fax: +(8) 3 440 368 South Korea Korea Co Ltd Phone: +(8) 99-66 Fax: +(8) 9-903 Malaysia Engineering Sdn Bhd Phone: +(60-3) 98-4988 Fax: +(60-3) 98-89 Philippines Systems (Philippines) Inc. Phone: +(63-) 636-66/66 Fax: +(63-) 638-403 Singapore South East Asia Phone: +(6) 63-88 Fax: +(6) 644-3033 Thailand Systems (Thailand) Ltd. Phone: +(66) 693-3099 Fax: +(66) 693-308 Taiwan R.O.C. Taiwan Ltd. Phone: +(886-) 4-000 Fax: +(886-) 4-34 EUROPE Austria Austria GmbH Phone: +(43) 80 366/46 Fax: +(43) 80 33 Belgium SA/NV Phone: +(3) 8 Fax: +(3) 8 0 Bulgaria EOOD Phone: +(39) 99 00 3 Fax: +(39) 99 00 4 Czech Republic spol. s.r.o. Phone: +(40) 4 44 Fax: +(40) 4 44 8 Denmark A/S Phone: +(4) 39 Fax: +(4) 39 8 Finland OY Phone: +(38) 9 34800 Fax: +(38) 9 34803 France SA Phone: +(33) 60 9 80 40 Fax: +(33) 60 9 8 3 Germany AG Phone: +(49) 69 8064 444 Fax: +(49) 69 8064 44 Hungary Kft. Phone: +(36 ) 4 4300 Fax: +(36 ) 4 4343 Italy S.p.A. Phone: +(39) 0 946 40/46 Fax: +(39) 0 946 490 The Netherlands B.V. Phone: +(3) 0 6 69 Fax: +(3) 0 6 66 00 Norway A/S Phone: +(4) 66 6 0 00 Fax: +(4) 66 6 0 90 Poland Sp. zo.o Phone: +(48)606 0964 Fax: +(48)606 090 Portugal Portugal Lda Phone: +(3 ) 44 0 00 Fax: +(3 ) 44 0 99 Romania Bucharest Phone: +(40) 3 64 3/38 Fax: +(40) 3 6439 Commonwealth of Independent States (CIS) Z.A.O. Phone: +( 09) 96 98 36 Fax: +( 09) 96 98 93 Slovak Republic s.r.o. Phone: +(4 ) 8 4 403 Fax: +(4 ) 8 4 4 South Africa (Republic of) Southern Africa S.A. Pty. Ltd Phone: +() 80 0 Fax: +() 80 04 Spain S.A. Phone: +(34) 9 33 600 Fax: +(34) 9 33 69 Sweden AB Phone: +(46) 8 00 Fax: +(46) 8 6 00 Switzerland AG Phone: +(4) 8 4 40 Fax: +(4) 8 4 4 Turkey Turkey A.S. Phone: +(90) 6 660 Fax: +(90) 6 663 Ukraine Phone: +(380) 44 0 44 4 Fax: +(380) 44 0 44 United Kingdom Control Systems Ltd Phone: +(44) 698 4848 Fax: +(44) 698 4866 Mediterranean & African Distributors SpA Phone: +(39) 9 46 3 Fax: +(39) 9 46 33 Middle East Headquarters Middle East Ltd. Phone: +(9) 443 9 Fax: +(9) 443 36 NORTH AMERICA USA/Canada Control Products, International Headquarters Phone: -800-3-694-8-3-684 Fax: -8-3-64 E-mail: info.sc@honeywell.com LATIN AMERICA Latin America Headquarters Phone: -30-80-888 Fax: -30-883-8 Argentina S.A.I.C. Phone: +(4-) 4383-363 Fax: +(4-) 43-640 Brazil do Brasil & Cia Phone: +(-) 466-900 Fax: +(-) 466-90 Chile Chile, S.A. Phone: +(6-) 4-8400 Fax: +(6-) 4-840 Mexico S.A. de C.V. Phone: +() 08-000 Fax: +() 08-00 Puerto Rico, Caribbean Inc. Phone: +(809) 9-0 Fax: +(809) 9-003 Venezuela CA Phone: +(8-) 3-0 Fax: +(8-) 3-099 This publication does not constitute a contract between and its customers. The contents may be changed at any time without notice. It is the customer's responsibility to ensure safe installation and operation of the products. Detailed mounting drawings of all products illustrated are available on request. 004 International Inc. All rights reserved. Chemin du Vieux Chêne 3840 Meylan Cedex France 038-0-EN FR6 GLO 304 Printed in Germany West Spring Street Freeport, Illinois 603 USA www.honeywell.com/sensing