Apples to Apples: Which Camera Technologies Work Best for Beam Profiling Applications, Part 3: Beam Aperturing Methods

Similar documents
A discussion of Laser Beam Profiling and the subject of Accuracy

Beam Profiling. Introduction. What is Beam Profiling? by Michael Scaggs. Haas Laser Technologies, Inc.

11Beamage-3. CMOS Beam Profiling Cameras

Information & Instructions

Coherent Laser Measurement and Control Beam Diagnostics

Very high-order pure Laguerre-Gaussian mode selection in a passive Q-switched Nd:YAG laser

Beam Analysis BeamWatch Non-contact, Focus Spot Size and Position monitor for high power YAG, Diode and Fiber lasers. Disruptive Technology

BEAMAGE-3.0 KEY FEATURES BEAM DIAGNOSTICS AVAILABLE MODELS MAIN FUNCTIONS SEE ALSO ACCESSORIES. CMOS Beam Profiling Cameras

ERS KEY FEATURES BEAM DIAGNOSTICS MAIN FUNCTIONS AVAILABLE MODEL. CMOS Beam Profiling Camera. 1 USB 3.0 for the Fastest Transfer Rates

On spatial resolution

How to Avoid Thermal Sensor Damage & Out of Tolerance Conditions

THE CCD RIDDLE REVISTED: SIGNAL VERSUS TIME LINEAR SIGNAL VERSUS VARIANCE NON-LINEAR

CCD reductions techniques

Camera Test Protocol. Introduction TABLE OF CONTENTS. Camera Test Protocol Technical Note Technical Note

BEAMAGE KEY FEATURES AVAILABLE MODELS. CMOS Beam Profiling Cameras

Last class. This class. CCDs Fancy CCDs. Camera specs scmos

Diffraction. Interference with more than 2 beams. Diffraction gratings. Diffraction by an aperture. Diffraction of a laser beam

arxiv:physics/ v1 [physics.optics] 12 May 2006

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

VC 16/17 TP4 Colour and Noise

Coherent addition of spatially incoherent light beams

Laser Beam Analysis Using Image Processing

Photons and solid state detection

OPTI 511L Fall (Part 1 of 2)

DataRay Software. Feature Highlights. Beam Profiling Camera Based WinCamDTM Series. Software Aperture/ISO measurements

Beamscope-P8 Wavelength Range. Resolution ¼ - 45 ¼ - 45

WFC3 TV3 Testing: IR Channel Nonlinearity Correction

Improving the Detection of Near Earth Objects for Ground Based Telescopes

Exercise 4-1 Image Exploration

Control of Noise and Background in Scientific CMOS Technology

White Paper: Modifying Laser Beams No Way Around It, So Here s How

Exercise questions for Machine vision

A Study of Slanted-Edge MTF Stability and Repeatability

Demo Pattern and Performance Test

THE CALIBRATION OF THE OPTICAL IMAGER FOR THE HOKU KEA TELESCOPE. Jamie L. H. Scharf Physics & Astronomy, University of Hawai i at Hilo Hilo, HI 96720

Theoretical Framework and Simulation Results for Implementing Weighted Multiple Sampling in Scientific CCDs

2013 LMIC Imaging Workshop. Sidney L. Shaw Technical Director. - Light and the Image - Detectors - Signal and Noise

Funded from the Scottish Hydro Gordonbush Community Fund. Metering exposure

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

Errata to First Printing 1 2nd Edition of of The Handbook of Astronomical Image Processing

CCD Requirements for Digital Photography

Photometry. Variable Star Photometry

Technical Explanation for Displacement Sensors and Measurement Sensors

GlassSpection User Guide

PROPERTY OF THE LARGE FORMAT DIGITAL AERIAL CAMERA DMC II

Sony PXW-FS7 Guide. October 2016 v4

Properties of Structured Light

Nikon Instruments Europe

Copyright 1997 by the Society of Photo-Optical Instrumentation Engineers.

Fully depleted, thick, monolithic CMOS pixels with high quantum efficiency

Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77. Table of Contents 1

Technical Note How to Compensate Lateral Chromatic Aberration

The predicted performance of the ACS coronagraph

SUPPLEMENTARY INFORMATION

Everything you always wanted to know about flat-fielding but were afraid to ask*

3.4 Introduction to Scanning-Slit Profilers

Focus on an optical blind spot A closer look at lenses and the basics of CCTV optical performances,

3.4 Introduction to Scanning-Slit Profilers

Applications: BeamGage as a Machine Vision System for Industrial Parts Inspection

Pixel Response Effects on CCD Camera Gain Calibration

Note: These sample pages are from Chapter 1. The Zone System

Astronomy 341 Fall 2012 Observational Astronomy Haverford College. CCD Terminology

Image Formation and Capture. Acknowledgment: some figures by B. Curless, E. Hecht, W.J. Smith, B.K.P. Horn, and A. Theuwissen

Swept-Field User Guide

BASLER A601f / A602f

The Noise about Noise

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 22.

DPSS 266nm Deep UV Laser Module

Bias errors in PIV: the pixel locking effect revisited.

UltraGraph Optics Design

Practical work no. 3: Confocal Live Cell Microscopy

X-RAY COMPUTED TOMOGRAPHY

NOTES/ALERTS. Boosting Sensitivity

Applications of Flash and No-Flash Image Pairs in Mobile Phone Photography

HF Upgrade Studies: Characterization of Photo-Multiplier Tubes

Topic 2 - A Closer Look At Exposure: ISO

Laser Induced Damage Threshold of Optical Coatings

Acoustic resolution. photoacoustic Doppler velocimetry. in blood-mimicking fluids. Supplementary Information

Measuring Procedure the Principle. The laser beam is scanned by means of a specialized measuring tip within a 3D measurement cylinder.

Records the location of the circuit board fiducials.

Electron-Multiplying (EM) Gain 2006, 2007 QImaging. All rights reserved.

Basler aca640-90gm. Camera Specification. Measurement protocol using the EMVA Standard 1288 Document Number: BD Version: 02

Devices & Services Company

Understanding the performance of atmospheric free-space laser communications systems using coherent detection

Enhanced Shape Recovery with Shuttered Pulses of Light

Spatial Investigation of Transverse Mode Turn-On Dynamics in VCSELs

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

ADVANCED OPTICS LAB -ECEN 5606

Laser Speckle Reducer LSR-3000 Series

Will contain image distance after raytrace Will contain image height after raytrace

AST Lab exercise: CCD

X-ray Spectroscopy Laboratory Suresh Sivanandam Dunlap Institute for Astronomy & Astrophysics, University of Toronto

Presented by Jerry Hubbell Lake of the Woods Observatory (MPC I24) President, Rappahannock Astronomy Club

Hartmann Wavefront Analyzer

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com

BeamPro 3.0 Series User Manual Revision WARRANTY

ENSC 470/894 Lab 3 Version 6.0 (Nov. 19, 2015)

Design Description Document

Applying of refractive beam shapers of circular symmetry to generate non-circular shapes of homogenized laser beams

Introduction to 2-D Copy Work

Transcription:

Apples to Apples: Which Camera Technologies Work Best for Beam Profiling Applications, Part 3: Beam Aperturing Methods Part 1: New Camera Technologies Part 2: Baseline Methods and Mode Effects By G.E. Slobodzian, Director of Engineering, Retired, Ophir-Spiricon In Part 2, we demonstrated the need for employing an accurately computed baseline and retaining both the positive and negative temporal noise inherent in the camera s output data. We observed that for the most common beam width methods, preserving the noise moved each method closer to reality, even though many of these results are not always a very accurate second moment equivalent. The ISO Solution For direct second moment D4σ calculations, providing a proper baseline is only a partial answer. We observed that the noise in the outlying regions surrounding the beam can yield wild frame to frame differences for the same beam. Thus, it becomes imperative to remove this outlying noise to obtain an accurate second moment beam width. The method taught by ISO-11146-3 in 2004 recommended isolating the beam profile with an aperture 3x the second moment beam width. Ten years before this ISO publication, Spiricon was already working on how to resolve this problem and came to a similar but somewhat different result. Part 2 demonstrated that the degraded signal to noise of a beam, modelled by a dimming beam profile, caused the second moment beam width results to gyrate wildly around its true value. In a similar way, reducing the size of the beam relative to the camera imager will have the same effect. Real Cameras Part 3 will investigate the aperture selection process using a state of the art CCD camera connected via a USB2 serial port. The camera is a Spiricon SP620 that outputs a 1600x1200 12 bit per pixel image format. The pixel pitch is 4.4µm² and

the camera has a dynamic range of ~60dBrms. Real cameras will create outputs not quite as perfect as we modelled using the BeamMaker utility. The modelled beams and the modelled noise were mathematically perfect. The black level and noise of a real camera is a bit more complex. Most cameras output some degree of imager shading and pixel to pixel offset variation. Temporal noise is reasonably Gaussian in distribution and is made up of imager, readout, amplifier, and digitizer noise. The readout noise will possess some random flutter in its distribution. This flutter can be observed by watching a histogram of the corrected baseline. Thermal effects can also be observed. The signal to noise tends to deteriorate with increase in temperature. And the black level baseline will also drift with temperature. Depending upon the camera design, some amount of power supply noise may also be observed in a black background. Cosmic rays passing thru the imager can generate false signals on one or groups of pixels. No matter the source of the noise, the end result is that it is not possible to create a perfectly stable background using a real camera. What this means is that the background Figure 3-1. BeamGage image of a stable HeNe Laser on a Spiricon SP620 CCD camera. noise baseline will statistically bounce around a zero point, but never be zero. If camera temperatures are fluctuating, the baseline will also be observed to drift with the changes in imager temperature. Figure 3-1 is a screen shot of a HeNe laser beam on the full size imager of the SP620. The beam s peak intensity is just below camera saturation. The camera baseline has been Ultracal d with the background indicating negative noise as a light grey and positive noise as dark purple. Without an aperture to restrict the calculation area, a plot of a dimming D4σ beam width result will look like the graph below. The data points are the results of 16 averaged samples and the error bars are plotted ±1 std dev.

All of the above beam width measurements are 10% or larger than the beams actual size. The increasing variability indicates that the background noise is shifted positive for all of the averaged results. The slightly positive shift could just as well Figure 3-2. X/Y D4s beam width vs beam intensity with baseline correction, be slightly without an aperture. negative, depending upon the luck of the draw. It is possible that the camera was still warming slightly as the above data was being collected. For comparison, below is a plot of the X-axis beam widths of the above data for 4 of the common beam width methods modelled in Part 2. Figure 3-3. Beam width vs beam intensity with baseline correction, without an aperture.

Based on the above results it appears that the actual beam width lies somewhere between.70 -.75mm. Aperture Sizing Now we will examine the same HeNe laser by applying fixed manual apertures at 6x, 4x, 3x, 2.5x and 2x the beam width. All graphs are normalized to the first sample at 100% intensity. Figure 3-4a. 6x Aperture Each graph is the results of a separate sample run and has been baseline corrected at the start of the run. 6x In Fig 3-4a, the 100% X/Y beam widths are.748mm and.756mm respectively. Both are at the high end of the.70-.75mm range. The error bars are quite large even at the 30% level. Figure 3-4b. 4x Aperture 4x In Fig 3-4b, the 100% X/Y beam widths are.736mm and.739mm respectively. The error bars are improving.

Figure 3-4c. 3x Aperture 3x In Fig 3-4c, the 100% X/Y beam widths are.734mm and.735mm respectively. Both are in the middle of the.70.75mm range. The error bars are under 1% at 24% intensity. This is the ISO recommended 3x aperture size and performs very well, yielding a very stable results over a large range of beam intensities. Figure 3-4d. 2.5x Aperture 2.5x In Fig 3-4d, the 100% X/Y beam widths are.733mm and.733mm, respectively. Both are in the middle of the.70.75mm range. The error bars are under 1% at 12% intensity. 2x In Fig 3-4e, the 100% X/Y beam widths are.725mm and.726mm, respectively. Both are in the middle of the.70.75mm range. The error bars are under 1% for the entire run. The beam width values are the lowest in the group and may be indicating that some of the beam is now being clipped by the aperture. Figure 3-4e. 2x Aperture

To complete our analysis of the above data, let s also compare the beam widths reported by the Dke10/90, D%ms, and the Depsa methods plotted together with the D4s values, and then plotted separately. In the graphs below the results plotted are the average of the X and Y values for each method. We will now only consider apertures between 2x and 3x, since it is obvious that larger ones are not practical, and since no one has suggested anything larger than 3x. Figure 3-5a. Figure 3-5b. Figure 3-5c.

Figure 3-6a. D4s Figure 3-6b. Depsa Figure 3-6c. Dke10/90 Figure 3-6d. D%ms Since we are measuring a near TEM00 HeNe laser, one would expect to find all of the results to be essentially the same. And indeed the spread from the highest to the lowest value is about ±3% from the median value. Graph 3-5a indicates that the 3x aperture yields the flattest results over the intensity range for all measurement methods. Independent of aperture size, graphs 3-6a and 3-6b show that the D4s and Depsa methods yield the highest results for all beam intensities, and the D%ms method yields the lowest results. Spiricon s Dke10/90 method falls neatly between, but closer to the lower D%ms method. As one might expect, the D4s method shows the largest variation with aperture size. Since all of the results are computed from the same beam images within each aperture size, the small disagreements must be from very subtle noise effects riding on the beam and in the beam wings. The fact that most of the beam widths drop with intensity is just what one would expect since as the signal at the outer edges of the beam falls into the noise it becomes difficult to separate the real beam from the noise.

Based on these results, it appears that any aperture sized between 2 to 3x the beam width would yield good D4s results, while above 3x things become more unstable, as indicated by the increasing error bars in graphs 3-4a and 3-4b. So are there any other considerations that might impact the choice of what size aperture may be best? In the previous scenarios the beam had special characteristics. It was circular, nearly TEM00, and relatively large compared to the size of the pixels. So what happens if the beam is less ideal? If for example, the beam is dominated by higher modes, or is very small relative to the imager size. Below is a comparison of the 2x, 2.5x, and 3x aperture on a TEM00 beam compared to beams of higher modes. Fig 3-7a. 2x Aperture b. 2.5x Aperture TEM00 c. 3x Aperture Fig 3-8a. 2x Aperture b. 2.5x Aperture Laguerre TEM10 c. 3x Aperture Fig 3-9a. 2x Aperture b. 2.5x Aperture Donut TEM01* c. 3x Aperture

Fig 3-10a. 2x Aperture b. 2.5x Aperture Laguerre TEM21 c. 3x Aperture Fig 3-11a. 2x Aperture b. 2.5x Aperture Hermite TEM11 c. 3x Aperture You can observe that for beams of higher modes, the 3x aperture, and to a lesser extent, the 2.5x aperture opens up a much larger area of background noise than does the 2x aperture. While the 2x aperture is a close fit to a TEM00, it none the less produced measurement accuracies well within acceptable ranges as noted in graph 3-5c. For comparison here s what the 4x and 6x apertures look like on the TEM00. Fig 3-12a. 4x Aperture TEM00 b. 6x Aperture We would never consider the 4x or 6x aperture appropriate for a TEM00 beam because the large open background causes the D4s results to suffer large swings due to noise and small background fluctuations. Yet these two apertures closely resemble the sizes for the 2.5x and 3x beams that contain higher modes. Of course,

in reality few real lasers contain pure higher modes. It has been demonstrated that beams build higher modes in a more or less systematic way as their M² values increase, at the expense of the embedded TEM00 mode. Thus as the higher modes increase the structures become even more complex than what is demonstrated above. As the modes increase, the beam widths increase relative to the area the beam covers, and as a result, any multiplied aperture increases even faster. So the above examples provide an answer to the question, which of the three favored apertures is a better choice over a wide range of possible beam modal scenarios - the 2x. But what about really tiny beams? Just to make sure the reader doesn t think we left out other possibilities, such as when the beam is very very very small relative to the size of the camera imager. This has also been evaluated and the outcome is similar to what is observed for the larger beam, but with one caveat. As a beam gets very small relative to the imager, the background noise fluctuations become so serious that the entire beam aperture calculation method has a difficult time actually locating the beam and determining a meaningful beam width to multiply. Under this condition, the operator must provide some assistance by first isolating the beam with a manual drawn aperture, or by reducing the camera s ROI (region of interest) to a window that more closely approximates the beam s size and location. Below is an example of what this looks like, first without and then with a manual aperture. The beam is the same HeNe used in the earlier examples, but focused down to 97μm. It is so small it barely shows up when viewing the entire imager. Spiricon s BeamGage software and an SP620 CCD camera are used to capture the image, and the cursor is showing its approximate location and size in the slice profiles. Fig 3-13a. Small Beam w/o Manual Aperture b. Small Beam w/ Manual Aperture

In both of the above images, the cursors are tracking the beam centroid. The calculated 2x aperture is in Yellow, while the size of the computed beam widths are displayed by the Green marker. The manual aperture is drawn in White. Figure 3-13a shows the small beam and the nonsense results based on the attempt to locate and size it. The noise is so dominant that the cursors cannot find the beam s centroid. If you were to observe this in real-time the image would change dramatically from frame to frame as the attempts to find and measure the beam are randomly pushed around by the background noise. In figure 3-13b, a simple manually drawn aperture has been placed around the beam. I drew it in without regard to its precise placement or size; just eyeballed it. BeamGage can now draw a good 2x aperture (the tiny yellow circle) and the cursors now easily locate and display the beam profiles. Here s what it looks like if we zoom in just a bit. The computed beam width results are included so you can see how well the different methods agree. F3-14. Small Beam, Zoomed in, w/ Manual Aperture, 2x Auto Aperture and Results Conclusions We now end Part 3 of this paper with the following conclusions: 1. To obtain an accurate D4s beam width for beams of both TEM00 and higher modes, a reasonably good background baseline must be determined and that baseline must contain both positive and negative noise. 2. To measure beams that vary greatly in size and modal content, an isolating aperture must be employed and that aperture is best chosen to be 2x the second moment beam width in the beam s X and Y-axes.

3. When beams become very small relative to the imager, a secondary manual aperture should be employed to isolate the background noise to a small region around the beam. We did not discuss the topic of how the aperture should be shaped. ISO 11146-1 shows a square or rectangular shape, but does not actually come out and say it should be flat sided. It can be demonstrated that the extra noise in the corners of a square aperture do increase the standard deviation somewhat, especially if it is sized 3x the beam width. When we first designed our Auto Aperture system at Spiricon, we intuitively decided that the auto aperture should be elliptical in shape. We ve kept that method and see no reason to change it. It may be that for some square shaped beams, especially Tophat Excimers, a rectangular shaped aperture might be more appropriate. The manual aperture tools in BeamGage allow you to choose between, Circular, Elliptical, Square, or Rectangular shapes. While this is not an Auto Aperture, it does provide the user with the option to use one of these manual aperture shapes instead of using the elliptical Auto Aperture. Coming next: In Part 4 we will explore the operation of our Photon scanning slit beam measurement products and compare them to camera-based systems. References 1. Carlos B Roundy, PhD; Techniques for Accurately Measuring Laser Beam Width with Commercial CCD Cameras, Spiricon, Inc., Logan, Utah 84341 USA, Presented At 4th International Workshop on Laser Beam and Optics Characterization 2. Amiel A. Ishaaya, Nir Davidson, Galina Machavariani, Erez Hasman, and Asher A. Friesem; Efficient Selection of High-Order Laguerre Gaussian Modes in a Q-Switched Nd :YAG Laser, IEEE JOURNAL OF QUANTUM ELECTRONICS, VOL. 39, NO. 1, JANUARY 2003 3. CCD IMAGE SENSOR NOISE SOURCES, August 3, 2012 Reference Document Rev 1.0 PS-0047, TRUESENSE imaging, inc. 4. Albert J.P. Theuwissen, Kleine Schoolstraat; Influence of Terrestrial Cosmic Rays on the Reliability of CCD Image Sensors, 2005 IEEE 5. ISO 11146-1:2005(E), Lasers and laser-related equipment Test methods for laser beam widths, divergence angles and beam propagation ratios Part 1:Stigmatic and simple astigmatic beams.

6. ISO/TR 11146-3:2004(E), Lasers and laser-related equipment Test methods for laser beam widths, divergence angles and beam propagation ratios Part 3: Intrinsic and geometrical laser beam classification, propagation and details of test methods 7. ISO/TR 11146-3:2004/Cor.1:2005(E), Lasers and laser-related equipment Test methods for laser beam widths, divergence angles and beam propagation ratios Part 3: Intrinsic and geometrical laser beam classification, propagation and details of test methods 8. Ram Oron, Nir Davidson, Asher A. Friesem, Erez Hasman; Chapter 6 Transverse mode shaping and selection in laser resonators, E. Wolf, Progress in Optics 42 2001 Elsevier Science B. V 9. A. E. Siegman; How to (Maybe) Measure Laser Beam Quality, Tutorial presentation at the Optical Society of America Annual Meeting Long Beach, California, October 1997 10. Siegman, Sasnett, and Johnston; Choice of Clip Levels for Beam Width Measurements Using Knife-Edge, IEEE Journal of Quantum Electronics, Vol. 27, No. 4, April 1991 Ophir Photonics Group http://www.ophiropt.com/photonics Copyright 2015, Ophir Photonics Group.