TitleFrequency Characteristics of the Ha. Author(s) Ishida, Takekazu; Kanoda, Kazushi;

Similar documents
Magnetic induction with Cobra3

Magnetic induction with Cobra3

Units. In the following formulae all lengths are expressed in centimeters. The inductance calculated will be in micro-henries = 10-6 henry.

PHYS 1442 Section 004 Lecture #15

CH 1. Large coil. Small coil. red. Function generator GND CH 2. black GND

15. the power factor of an a.c circuit is.5 what will be the phase difference between voltage and current in this

Development of the Electrical and Magnetic Model of Variable Reluctance Speed Sensors

Core Technology Group Application Note 1 AN-1

Design and Simulation of Passive Filter

Topic 4 Practical Magnetic Design: Inductors and Coupled Inductors

TRANSFORMER THEORY. Mutual Induction

Inductance in DC Circuits

EDDY CURRENT EXAM SIMULATION USING COUPLED FINITE ELEMENT/ VOLUME INTEGRAL OR FINITE ELEMENT/BOUNDARY ELEMENT METHOD

1. If the flux associated with a coil varies at the rate of 1 weber/min,the induced emf is

1 K Hinds 2012 TRANSFORMERS

An induced emf is the negative of a changing magnetic field. Similarly, a self-induced emf would be found by

EE 221 Circuits II. Chapter 13 Magnetically Coupled Circuits

TRANSFORMER OPERATION

CITY UNIVERSITY OF HONG KONG

TESTS ON THE TRANSFORMER (E-13)

13 th Asian Physics Olympiad India Experimental Competition Wednesday, 2 nd May 2012

CHAPTER 9. Sinusoidal Steady-State Analysis

LLC Resonance Power Transformers Using Magnetoplated Wire. and Shigeaki Tsuchiya b,

AP Physics C. Alternating Current. Chapter Problems. Sources of Alternating EMF

Chapter Moving Charges and Magnetism

A Resonant Tertiary Winding-Based Novel Air-Core Transformer Concept Pooya Bagheri, Wilsun Xu, Fellow, IEEE, and Walmir Freitas, Member, IEEE

Electronic Instrumentation

Current Probes. User Manual

Author(s) Yoshihisa; Noda, Akira; Inoue, Mako.

PHYSICS WORKSHEET CLASS : XII. Topic: Alternating current

PHYS 1444 Section 501 Lecture #20

A Numerical Study of Depth of Penetration of Eddy Currents

LEAKAGE FLUX CONSIDERATIONS ON KOOL Mµ E CORES

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

University of North Carolina-Charlotte Department of Electrical and Computer Engineering ECGR 4143/5195 Electrical Machinery Fall 2009

Design and Construction of a150kv/300a/1µs Blumlein Pulser

Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies

CHAPTER 2. Basic Concepts, Three-Phase Review, and Per Unit

Module 7. Transformer. Version 2 EE IIT, Kharagpur

The basic theory of the eddy current method has been developed in [1-2] and later amended for this application in [3].

Lab Manual Experiment No. 2

Unit Transformers

VARIABLE INDUCTANCE TRANSDUCER

Shielding Effect of High Frequency Power Transformers for DC/DC Converters used in Solar PV Systems

Walchand Institute of Technology. Basic Electrical and Electronics Engineering. Transformer

COMPUTER MODELING OF EDDY CURRENT TRANSMIT-RECEIVE PROBES FOR. S.P. Sullivan, V.S. Cecco, L.S. Obrutsky, D. Humphrey, S.P. Smith and K.A.

2.5D Finite Element Simulation Eddy Current Heat Exchanger Tube Inspection using FEMM

Title ZnO device and resistor in parallel IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY (2006), 16(2): 65.

ET1210: Module 5 Inductance and Resonance

Electrical Theory 2 Lessons for Fall Semester:

High Current Amplifier

Target Temperature Effect on Eddy-Current Displacement Sensing

Experiment 9 AC Circuits

2008 D AI Prove that the current density of a metallic conductor is directly proportional to the drift speed of electrons.

Chapter 16: Mutual Inductance

PHYS 1441 Section 001 Lecture #22 Wednesday, Nov. 29, 2017

Inductive sensors. The operating principle is based on the following relationship: L=f(x) M=g(x)

EC TRANSMISSION LINES AND WAVEGUIDES TRANSMISSION LINES AND WAVEGUIDES

Experiment 4: Grounding and Shielding

Title Coil Wound by Surface Winding Techn.

Lumped Network Model of a Resistive Type High T c fault current limiter for transient investigations

Use of inductive heating for superconducting magnet protection*

ESO 210 Introduction to Electrical Engineering

Chapter 13 Magnetically Coupled Circuits. Chapter Objectives:

Acoustic noise reduction of MRI systems by means of magnetic shielding

Research of Nikola Tesla in Long Island Laboratory

AN2972 Application note

VOLTECHNOTES. Transformer Basics VPN /1

Design Study. Reducing Core Volume in Matrix Transformers

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 04, 2014 ISSN (online):

Chapter 2. The Fundamentals of Electronics: A Review

Measuring Batteries using the Right Setup: Dual-cell CR2032 and Battery Holder

Voltage Biased Superconducting Quantum Interference Device Bootstrap Circuit

UNIVERSITY OF TECHNOLOGY By: Fadhil A. Hasan ELECTRICAL MACHINES

SYNCHRONOUS MACHINES

The power transformer

Impulse testing of coils and magnets: present experience and future plans

THE UNDER HUNG VOICE COIL MOTOR ASSEMBLY REVISITED IN THE LARGE SIGNAL DOMAIN BY STEVE MOWRY

LC Resonant Circuits Dr. Roger King June Introduction

VE7CNF - 630m Antenna Matching Measurements Using an Oscilloscope

PHYS 1444 Section 003 Lecture #19

APPLICATION NOTE - 018

EIS Measurement of a Very Low Impedance Lithium Ion Battery

09-2 EE 4770 Lecture Transparency. Formatted 12:49, 19 February 1998 from lsli

Inductive sensors. The operating principle is based on the following relationship: L=f(x) M=g(x)

CHAPTER 6: ALTERNATING CURRENT

Control of Induction Thermal Plasmas by Coil Current Modulation in Arbitrary-waveform

Power Electronics. Exercise: Circuit Feedback

ELECTROMAGNETIC COMPATIBILITY HANDBOOK 1. Chapter 8: Cable Modeling

The VOLTECH Handbook of Transformer Testing Issue 4 Page 1

CHAPTER 5 Test B Lsn 5-6 to 5-8 TEST REVIEW

DSC Lab 2: Force and Displacement Measurement Page 1

A Finite Element Simulation of Nanocrystalline Tape Wound Cores

Predicting Total Harmonic Distortion (THD) in ADSL Transformers using Behavioural Modeling

Operating principle of a transformer

ELECTRICAL MEASUREMENTS

Lab 4. Crystal Oscillator

Experiment 5: Grounding and Shielding

Department of Electrical and Computer Engineering Lab 6: Transformers

3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)

Transcription:

TitleFrequency Characteristics of the Ha Author(s) Ishida, Takekazu; Kanoda, Kazushi; Citation Bulletin of the Institute for Chemi University (1983), 61(1): 45-49 Issue Date 1983-3-25 URL http://hdl.handle.net/2433/7715 Right Type Departmental Bulletin Paper Textversion publisher Kyoto University

Bull. Inst. Chem. Res., Kyoto Univ., Vol. 61, No. 1, 1983 IIIIIIIIIIIIIIL Note IIIIIIIIIIIIIIU Frequency Characteristics of the Hartshorn Bridge Takekazu IsHIDA, Kazushi KANODA, and Hiromasa MAZAKI* Received January 2, 1983 We give the frequency characteristics of the conventional Hartshorn bridge from 1 Hz to 2 khz at 4. 2, 77, and 3 K. The results indicate that the response depends strongly on the resistance, the inductance, and the stray capacity of a cryostat coil. KEY WORDS: Low temperature/ Hartshorn bridge/ Frequency dependence/ Complex susceptibility/ In a periodically varying magnetic field, the response of substance is expressed by complex susceptibility x(w) =x'(w) ix"(w). The Hartshorn-type ac bridge has been widely employed to measure x(m) in the field of low-temperature physics, where x' and x" are usually obtained by the change in null points of a standard mutual inductance and of a phaseshift potentiometer, respectively. However, since this method requires an elaborate effort in balancing the bridge, we reported an off-balancing technique by using two-phase lock-in analyzer, including its useful application for higher-harmonic susceptibility.'"3' In recent years, a lot of interesting properties have been deduced from frequency dependence of susceptibility.31 However, the fact is that the frequency characteristics of the Hartshorn bridge is not well understood. In the present note, we attempt to reveal the frequency response of the bridge. Here we used frequencies 1 Hz khz at coil temperatures 4.2, 77, and 3 K. The present cryostat coil consists of coaxial cylindrical coils. The two inner-coils (secondary) are wound in counter direction to each other. Each of them is 36 turns of insulated Cu wire (.14 mm in diameter) in twenty layers. The primary coil of 5482 turns is wound in contact with the secondary coil in eight layers. The mutual inductance of sensitivity. 1 ph can be varied from 1 tell to 1 ph. The phaseshift potentiometer consists of an extended wire (1 m in length), of which the sensitivity is 1 mt2/cm and the range is from - 5 mq to 5 ms2. In Figs. 1 and 2, we show the null points of the standard mutual inductance (P component) and the potentiometer (Q component) with respect to frequency at 4. 2, 77, and 3 K. By removing the cryostat coil from the bridge, we performed similar measurements (see Figs. 1 and 2). At each null point, the lock-in phase is set so as to give the in-phase and out-of-phase signals correctly (see Fig. 3). With the aid of Figs. 1-3, one can * Z IEEI p, irm-ge: Laboratory of Nuclear Radiation, Institute for Chemical Research, Kyoto University, Kyoto, Japan. ( 45 )

T. ISHIDA, K. KANODA, and H. MAZAKI o o o q q x x x xx =o+ g' ee Z W n_ o X WITHOUT COIL + 3 K. 77 K CL o 4.2 K CO 111213 FREQUENCY ( HZ ) Fig. 1. Null point of the standard mutual inductance (P component) vs frequency. The amplitude of the field is 269 moe. co o xs4 gi4@8mx E o x x x x x Z o+ W Z -+ CD a- X WITHOUT COIL o-+ 3 K C_) y A 77 K - 4.2 K co--------------------------------------------------------------------------------------------------ii,11 1I 1 I 1111II 1 21 I 1 1 I I Ill1 3 1 I II FREQUENCY (HZ ) Fig. 2. Null point of the potentiometer (Q component) vs frequency. The amplitude of the field is 269 moe. easily find the null point at any temperature and any frequency. Consulting the measurements without the coil, it is apparent from Figs. 1-3 that the frequency dependence comes from the cryostat coil. The possible origins of frequency-dependent behavior are: (a) the eddy current loss of windings, (b) the circuit impurity such as stray capacity between primary and ( 46 )

Frequency Characteristics of the Hartshorn Bridge a, a _ + ~ _X ) ; ; eep@axx x U, ZO) ~ox.--~o I a W o X WITHOUT COIL (f) 9 _ + 3 K U l 46. 77 KX to O4 Q -,2K a o in-------------------------------------------------------------------------------- 1 1111 1112 1 1 111 11I1 31 1 I I FREQUENCY ( HZ) Fig. 3. Setting phase of lock-in analyzer (Ithaco model 393) vs frequency. The amplitude of the field is 269 moe. secondary coils, and (c) the coil inductances and resistances." When the coil temperature goes down, the predominant effect would be expected to appear in its resistance, and one may assume that both the inductance and capacity give minor effect, because they depend mainly on geometry, but not on temperature. First, we discuss the phenomena in terms of eddy current loss. We present the expression of x' and x" for an annular normal conductor by5' x 1 1(1) 47r 1+ (rl/4rz2wa2) 2 ' X" _1 (rl/4ir2wa2)(2 ) 4n 1 + (rl/4ir2oua2)2' where r is the resistance around the cylinder, l is the length of cylinder, a is the radius, and w is the angular frequency. Equations (1) and (2) represent a usual skin effect at high frequency, and both x' and x" are monistically determined by ratio r/w. Therefore, if the effect of eddy current is the only reason to explain the observation, the profiles of x' and x" plotted with respect to frequency (logarithmic scale) must be the same even for different temperatures, 4. 2, 77, and 3 K, although the profiles shift in the frequency region concerned. As shown in Figs. 1 and 2, one finds that this is not the case in our results. Second, we discuss the impurity effect by considering the stray capacity C between primary and secondary coils, which is not usually taken into consideration in the bridge. In Fig. 4 is shown the equivalent circuit of the Hartshorn bridge. The resistance of phase-shift potentiometer (-. 112) is negligibly small compared to that of cryostat coil. ( 47 )

T. ISHIDA, K. KANODA, and H. MAZAKI I i P C E2 $ 12 ' -i- P L2- P R1R2 Fig. 4. The equivalent circuit of the Hartshorn bridge. RI, R2, Ll, and L2 are resistances and inductances of primary and secondary coils. P is the mutual inductance and C is the stray capacity. 71 is the primary current and E2 is the induced secondary voltage. The resistances of coil are about 5, 5, and 4 Q at 4. 2, 77, and 3 K, respectively. The mutual inductance (P component) is reasonably chosen as zero at null point. Then we get the transfer function G(s) by G(s) =1 ZIZ2Z3 + ZIZ3+Z3Z3'(3 ) where Z,= RI+LIs, Z2= R2+L2s, and Z3=Cs of the subsidiary variable s. Here R and L are the resistance and the inductance of coil and the subscripts denote the primary and secondary circuits. In order to normalize the output E2 by frequency, we use a transfer function F(s) =G(s)/RIR2Cs and analyze its frequency characteristics in terms of gain and phase. We assume LI=L2=L and Ri= R2= R. Thus, F(s) can be rewritten as F(s)(- (1 +rs) 2 1+2(Ts+T2s2'4 ) where r=l/ R, T= (2CL) 112, (= R(C/2L)112. The inductance L used here is about 1 mh. Then r-' is approximately 5, 5, and 4 Hz at 4. 2, 77, and 3 K, respectively. From the relation T=2(r, T-' is about 1 khz. We calculate gain and phase as a function of cot(=1-3.12) for C=.125,. 125, and.375. In Fig. 5 are shown the calculated results. In the figure, it can be seen that the frequency characteristics strongly depends upon ( (or R). The frequency profile is not the same for three cases. This is in contrast with the eddy current effect. At the lowest R((=. 125), the gain (logarithmic scale) show a maximum. This may clue us to the Q-component maximum appeared at 4.2 K in Fig. 2. In conclusion, we suggest that the circuit impurity such as stray capacity between primary and secondary coils plays an important role in the high-frequency performance of the bridge. To improve the bridge, it should be useful to make a coil of different L and R. Below 4.2 K, a superconducting cryostat coil seems to be very interesting. (48)

Frequency Characteristics of the Hartshorn Bridge (1).125!II (2).125 ij (3).375 ~~~ I 1 I 2 3 3 -)-2-1 1 2 111 1 1 1 cv T Fig. 5. Frequency characteristics of the equivalent circuit. Upper three curves are gains (arbitrary logarithmic scale) vs cot. Lower three curves are phases (arbitrary scale) vs ad'. Inserted numbers are values of C. ACKNOWLEDGMENTS One of the authors (T. I.) is indebted to the Japan Science for a grant. Society for the Promotion of REFERENCES ( 1 ) T Ishida and H. Mazaki, J. Appi. Phys., 52, 6798 (1981). (2) T. Ishida and H. Mazaki, Phys. Lett. A, 87, 373 (1982). (3) C. A. M. Mulder, A. J. van Duyneveldt, and J. A. Mydosh, Phys. Rev. B, 25, 515 (1982). (4) D. Bijl, Thesis, Leiden University (195) unpublished. (5) A. Paskin, M. Strongin, P. P. Craig, and D. G. Schweitzer, Phys. Rev., 137, A1816 (1965). ( 49 )