Model Number Structure

Similar documents
Digital Indicators. K3HB Series (Pulse Input Series) Features

Model Number Structure

Model Number Structure

K3HB-P. Model Number Structure. Timer Interval Indicator. Model Number Legend. Base Units with Optional Boards. Optional Board

Model Number Structure

Features. Panel Meters with Advanced Signal Processing Capabilities K3HB

Model Number Structure

Digital Indicators K3HB Series

K3HB-H. Model Number Structure. Temperature Indicator. Model Number Legend Base Units with Optional Boards

K3HB-R. Model Number Structure. Rotary Pulse Indicator. Model Number Legend. Base Units with Optional Boards. Base Units.

Model Number Structure

CompoBus/D-type Digital Controller

Model Number Structure

Solid-state Timer H3DS

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

NPN PNP NPN PNP NPN PNP

Model Number Structure


Count/Time Totalizers

Digital Counter. DIN 72 x 72 mm Counters with Easy-to-use Functions

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Solid-state Twin Timer

Process Meter. Applicable

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Model Number Structure

Solid-state Timer H3DE

ELECTRONIC COUNTER (with pre-scaling function) UL File No.: E C-UL File No.: E122222

Model Number Structure

Supply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000

Solid-state Timer H3DS

Fuzzy Temperature Controllers E5AF

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Temperature Controllers E5 J

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

APPENDIX APPENDIX A 1

Solid-state Timer H3DE

Model Number Structure

Phase-sequence Phase-loss Relay

Model Number Structure

FA Wireless SS Terminals

Ordering Information. Application Example. New General-purpose Incremental. Rotary Encoder

Resolution (divisions) 256, 360, , 360, 720, 1,024 Pre-wired Model

Solid-state Timer H3DS

Self-powered Counter

Name Number of I/O points (words used) Model Antenna style. 512 outputs max. (32 words) Magnetic Base Antenna (1) --- WD30-AT001 (See note.

E2Q5. Square Proximity Sensor. Long Distance Square Inductive Proximity Sensor. Ordering Information

E3X-NL. Employs OMRON's Unique Free Angle Optics Technology for Detecting Minute Differences in Glossiness. Optical Fiber Glossy Object Sensor

Safety Relay Unit. OFF-delay time

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

Power supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)

Solid-State Digital Counter H7AN

SPECIFICATIONS Digital Indicator 1. General

Output configuration. Dark-ON. Light-ON. Dark-ON. Light-ON. Dark-ON. Light-ON

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

PLC-K506 Series FEATURES DESCRIPTION FEATURES

Contents H3DS. DIN Track Mounted, Standard 17.5-mm Width Timer Range. Broad Line-up of H3DS Series. Solid-state Timer. Common to ALL Timers H3DS-X

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

02/11/2015

SPST-NO SPDT DPST-NO DPDT

02/11/2015

Position Indicator with/without Limit Values

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

Single-phase Voltage Relay

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Single-phase Current Relay

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)

Multi-point Temperature Controller

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Absolute Rotary Encoder

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm.

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

Energy Management Three-phase energy meter with output modules Type EM4-DIN

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

Incremental Rotary Encoder E6B2

Panel Mount PLC. NEW standard: Timer + Counter + Temperature Controller + PLC. The FP-e PLC comes in the following three types

General Specifications

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series

96M0374. Instruction Manual. Analog Sensor Controller. RD Series

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

Z500. High-Precision Sensor that Measures and Displays an Object's Profile. Profile Measuring System

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

Process displays For standard signals, temperature, resistance measurement

onlinecomponents.com

Y Type. W Type. AC voltage AC current

Remote Sensor Amplifier Terminal

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:

E5EC/E5AC-800. Main I/O Functions. Digital Temperature Controller (Simple Type) (48 96 mm/96 96 mm)

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Multifunctional counter tico 772/773/774

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Field Network SRT Series

Transcription:

Authorised Distributors:- AS & AAIN INDIA PVT TD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-4797575 Fax : 011-4797574 E-mail : sales@ashalain.com Up/Down Counting Pulse Indicator CSM DS_E_7_1 Measure igh-speed Up/down Pulses with this Up/down Pulse Meter. Perfect for Measuring Rotary Encoder and ON/OFF Pulse Signals at igh Speed Cumulative pulse input is 50 kz, quadrature pulse inputs are 5 kz, and up/down pulse inputs are 0 kz. Note: No-voltage contacts of up to 0 z are supported. The count value can be converted to any value. The length equivalent for any pulse can be set to any desired value. This is effective for feed amount and position monitor displays. Refer to Safety Precautions for All Digital Panel Meters. Model Number Structure Model Number egend Base Units and Optional Boards can be ordered individually or as sets. Base Units 1 5 1. Input Sensor Code NB: NPN input/voltage pulse input 5. Supply Voltage 100-40 VAC: 100 to 40 VAC 4 VAC/VDC: 4 VAC/VDC Optional Board Sensor Power Supply/Output Boards Relay/Transistor Output Boards Event Input Boards K- K4- K5-4 A Special BCD Output Cable (sold separately) is required. 4. Event Input Type Code None: None 1: 5 inputs (M terminal block), NPN open collector : 8 inputs (10-pin MI conn ector), NPN open collector : 5 inputs (M terminal block), PNP open collector 4: 8 inputs (10-pin MI connector), PNP open collector Note: 1. CPA can be combined with relay outputs only.. Only one of the following can be used by each Digital Indicator: RS-C/RS-485 communications, a linear output, or DeviceNet communications. Accessories (Sold Separately) K-DICN: Special Cable (for event inputs with 8-pin connector) K-BCD: Special BCD Output Cable Base Units with Optional Boards - 1 4 5. Sensor Power Supply/Output Type Code None: None CPA: Relay output (PASS: SPDT) + Sensor power supply (1 VDC±10%, 80 ma) (See note 1.) 1A: inear current output (0 to 0 or 4 to 0 ma DC) + Sensor power supply (1 VDC±10%, 80 ma) (See note.) A: inear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power supply (1 VDC±10%, 80 ma) (See note.) A: Sensor power supply (1 VDC ±10%, 80 ma) FK1A: Communications (RS-C) + Sensor power supply (1 VDC±10%, 80 ma) (See note.) FKA: Communications (RS-485) + Sensor power supply (1 VDC±10%, 80 ma) (See note.). Relay/Transistor Output Type Code None: None C: Relay contact (///: SPST-NO each) T1: Transistor (NPN open collector: //PASS//) T: Transistor (PNP open collector: //PASS//) BCD?:BCD output + transistor output (NPN open collector: //PASS//) DRT: DeviceNet (See note.) * Rubber Packing K-P1 Model Note: Rubber packing is provided with the Controller. 1

Specifications Ratings Supply voltage Allowable power supply voltage range Power consumption (See note 1.) Current consumption Input External power supply 100 to 40 VAC, 4 VAC/VDC, DeviceNet power supply: 4 VDC 85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 5 VDC 100 to 40 VAC: 18 VA max. (max. load) 4 VAC/DC: 11 VA/7 W max. (max. load) DeviceNet power supply: 50 ma max. (4 VDC) No-voltage contact, voltage pulse, open collector 1 VDC±10% 80 ma Event inputs old input NPN open collector or no-voltage contact signal Reset input ON residual voltage: V max. ON current at 0 Ω: 4 ma max. Bank input Max. applied voltage: 0 VDC max. OFF leakage current: 0.1 ma max. Output ratings Relay output 50 VAC, 0 VDC, 5 A (resistive load) (depends on Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations the model) Transistor output Maximum load voltage: 4 VDC, Maximum load current: 50 ma, eakage current: 100 µa max. inear output inear output 0 to 0 ma DC, 4 to 0 ma DC: oad: 500 Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS inear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC: oad: 5 kω max, Resolution: Approx. 10,000, Output error: ±0.5% FS (1 V or less: ±0.15 V; no output for 0 V or less) Display method Negative CD (backlit ED) display 7-segment digital display (Character height: PV: 14. mm (green/red); SV: 4.9 mm (green)) Main functions Scaling function, measurement operation selection, output hysteresis, output OFF delay, output test, display value selection, display color selection, key protection, bank selection, display refresh period, maximum/minimum hold, reset Ambient operating temperature 10 to 55 C (with no icing or condensation) Ambient operating humidity 5% to 85% Storage temperature 5 to 65 C (with no icing or condensation) Altitude,000 m max. Accessories Watertight packing, fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include a DeviceNet connector (irose R1-5.08P-5SC(01)) and crimp terminals (irose R1-SC-11) (See note.) Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommended.. For KB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Cables.

Characteristics Connectable sensors ON residual voltage: V max. OFF leakage current: 1.5 ma max. oad current: Must have a switching capacity of 0 ma or higher. Must be able to properly switch load currents of 5 ma or less. Max. No. of display digits 5 ( 19999 to 99999) Comparative output response time inear output response time Insulation resistance Dielectric strength Noise immunity Vibration resistance Shock resistance Weight Degree of Front panel protection Rear case Terminals Memory protection Applicable standards EMC Display range 19,999 to 99,999 Measurement range Functions F1, F: ± gigacounts Functions F: 0 to 4 gigacounts Input signals Contact input (dry contact input) (0 z max. with ON/OFF pulse width of 15 ms min.) No contact Mode Input frequency ON/OFF ON voltage OFF voltage Input voltage pulse range pulse width impedance F1 0 to 0 kz 16 μs min. 4.5 to 0 V 0 to V 10 kω F 0 to 5 kz 0 μs min. F 0 to 50 kz 9 μs min. Open collector Mode Input frequency ON/OFF range pulse width Note: The Up/Down Counting Pulse F1 0 to 0 kz 16 μs min. Meter will malfunction if a pulse greater than the input frequency F 0 to 5 kz 0 μs min. range is input. SYSERR may F 0 to 50 kz 9 μs min. appear on the display. 1 ms max.: Transistor output; 10 ms max.: Relay contact output (time until the comparative output is made when there is a forced sudden change in the input signal from 15% to 95% or 95% to 15%) 10 ms max. (time until the final analog output value is reached when there is a forced sudden change in the input signal from 15% to 95% or 95% to 15%) 0 MΩ min. (at 500 VDC),00 VAC for 1 min between external terminals and case 100 to 40 VAC models: ±1,500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse width of 1 μs/100 ns) 4 VAC/VDC models: ±1,500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse width of 1 μs/100 ns) Frequency: 10 to 55 z; Acceleration: 50 m/s, 10 sweeps of 5 min each in X, Y, and Z directions 150 m/s (100 m/s for relay outputs) times each in axes, 6 directions Approx. 00 g (Base Unit only) Conforms to NEMA 4X for indoor use (equivalent to IP66) IP0 IP00 + finger protection (VDE0106/100) EEPROM (non-volatile memory) Number of rewrites: 100,000 U61010C-1, CSA C. No. 1010.1 (evaluated by U) EN61010-1 (IEC61010-1): Pollution degree /Overvoltage category II EN616: 1997, A1: 1998, A: 001 EMI: EN616 industrial applications Electromagnetic radiation interference CISPR 11 Group 1, Class A Terminal interference voltage CISPR 11 Group 1, Class A EMS: EN616 industrial applications Electrostatic Discharge Immunity EN61000-4-: 4 kv (contact), 8 kv (in air) Radiated Electromagnetic Field Immunity EN61000-4-: 10 V/m sine wave amplitude modulation (80 Mz to 1 Gz, 1.4 to Gz) Electrical Fast Transient/Burst Noise Immunity EN61000-4-4: kv (power line), 1 kv (I/O signal line) Surge Immunity EN61000-4-5: 1 kv with line (power line), kv with ground (power line) Conducted Disturbance Immunity EN61000-4-6: V (0.15 to 80 Mz) Power Frequency Magnetic Immunity EN61000-4-8: 0 A/m (50 z) continuous time Voltage Dips and Interruptions Immunity EN61000-4-11: 0.5 cycle, 0 /180, 100% (rated voltage)

Operation Functions (Operating Modes) F1 to F Function name Individual inputs Phase differential inputs Pulse counting input Function No. f1 f f Function Operation Operation image (application) F1 Individual inputs Counts input A as incremental pulses and input B as decremental pulses. The count is incremented on the rising edge of input A and decremented on the rising edge of input B. If both inputs rise at the same time, the count is not changed. The count is incremented when input B is later than input A and decremented when input B is earlier than input A. Counting the number of people entering an area Photoelectric sensor Input A BCD output To Programmable Controller Input A Input B Input B Increment OD input Decrement 1 1 1 Count 0 F Phase differential inputs This function is normally used when connected to an incremental rotary encoder. The count is incremented on the falling edge of input B when input A is OFF. The count is decremented on the rising edge of input B when input A is OFF. Detecting position and speed on a semiconductor wafer conveyor line Wafer F Pulse counting input Input A Input B OD input Count 0 Counted on the rising edge of input A Input A OD input Count 0 1 1 (See note.) 4 1 1 0 5 Counting the number of workpieces 6 BCD output To Programmable Controller E6 Note: 1. Meaning of and in Display Symbol Input method No-voltage input Short- Open. Requires at least half the minimum signal width. If there is less than half, a ±1 count error may occur. Input Type Setting NO: Voltage pulse high NC: Voltage pulse low No-contact or voltage pulse input 00 01 Contact 10 11 4

What Is Prescaling? Prescaling converts the count value to any numeric value. To display @@@@.@ mm in a system that outputs 50 pulses for a 0.5-m feed, the length per pulse = 500 mm (0.5 m) 50 =. 1. The prescale value for the is set using the mantissa X exponent Y, so the prescale value =.0000 10, X =.000, and Y = 00.. Next, set the decimal point position for one digit to the right of the decimal point: 0.5 m Encoder 50 pulses 5

Common Specifications Event Input Ratings KB-P/-C OD, RESET, BANK1, BANK, BANK4 Contact ON: 1 kω max., OFF: 100 kω min. No-contact ON residual voltage: V max. OFF leakage current: 0.1 ma max. oad current: 4 ma max. Maximum applied voltage: 0 VDC max. Output Ratings Contact Output Item Rated load Rated through current Mechanical life expectancy Electrical life expectancy Resistive loads (50 VAC, cosφ=1; 0 VDC, /R=0 ms) 5 A at 50 VAC 5 A at 0 VDC 5 A 5,000,000 operations 100,000 operations Inductive loads (50 VAC, closed, cosφ=0.4; 0 VDC, /R=7 ms) 1 A at 50 VAC 1 A at 0 VDC Transistor Outputs Maximum load voltage 4 VDC Maximum load current 50 ma eakage current 100 µa max. inear Output Item Outputs 0 to 0 ma 4 to 0 ma 0 to 5 V 1 to 5 V 0 to 10 V Allowable load impedance 500 Ω max. 5 kω min. Resolution Approx. 10,000 Output error ±0.5% FS ±0.5% FS (±0.15 V for 1 V or less and no output for 0 V) Serial Communications Output Item Type RS-C, RS-485 Communications method alf duplex Synchronization method Start-stop synchronization (asynchronous) Baud rate 9600/1900/8400 bps Transmission code ASCII Data length 7 bits or 8 bits Stop bit length bits or 1 bit Error detection Vertical parity and FCS Parity check Odd, even BCD Output I/O Ratings (Input Signal ogic: Negative) I/O signal name Item Rating Inputs REQUEST CCOMPEN- Input signal No-voltage contact input SATION Input current for no-voltage input 10 ma RESET Signal level ON voltage 1.5 V max. OFF voltage V min. Outputs DATA Maximum load voltage 4 VDC POARITY OVER Maximum load current 10 ma DATA VAID RUN eakage current 100 µa max. OUT1 OUT OUT OUT4 OUT5 Maximum load voltage Maximum load current eakage current 4 VDC 50 ma 100 µa max. Refer to the KB Communications User's Manual (Cat. No. N19) for details on serial and DeviceNet communications. 6

DeviceNet Communications Communications protocol Supported Remote I/O communications communications I/O allocations Message communications Connection methods Baud rate Communications media Communications distance Conforms to DeviceNet Master-Slave connection (polling, bit-strobe, COS, cyclic) Conforms to DeviceNet communications standards. Allocate any I/O data using the Configurator. Allocate any data, such as DeviceNet-specific parameters and variable area for Digital Indicators. Input area: blocks, 60 words max. Output area: 1 block, 9 words max. (The first word in the area is always allocated for the Output Execution Enabled Flags.) Explicit message communications CompoWay/F communications commands can be executed (using explicit message communications) Combination of multi-drop and T-branch connections (for trunk and drop lines) DeviceNet: 500, 50, or 15 Kbps (automatic follow-up) Special 5-wire cable ( signal lines, power supply lines, 1 shield line) Baud rate Network length (max.) 500 Kbps 100 m max. (100 m max.) 50 Kbps 100 m max. (50 m max.) 15 Kbps 100 m max. (500 m max.) Drop line length (max.) 6 m max. 9 m max. 6 m max. 78 m max. Total drop line length (max.) 6 m max. 156 m max. The values in parentheses are for Thick Cable. Communications power supply 4-VDC DeviceNet power supply Allowable voltage fluctuation range 11 to 5-VDC DeviceNet power supply Current consumption 50 ma max. (4 VDC) Maximum number of nodes 64 (DeviceNet Configurator is counted as one node when connected.) Maximum number of slaves 6 Error control checks CRC errors DeviceNet power supply Supplied from DeviceNet communications connector 7

Connections External Connection Diagrams Terminal Arrangements Note: Refer to Internal Block Diagram on page 10 for information on isolation. A Operating Power Supply 1 100 to 40 VAC 4 VAC/VDC 4 5 A1 6 A A B C D E *Check the required power supply type. B Sensor Power Supply/Output Sensor power supply + PASS output C Relays, Transistors, BCD and DeviceNet B1 PASS 1 VDC 80 ma B B B4 B5 B6 Sensor power supply <CPA> Sensor power supply + linear output + 0-5/1-5/ B1 0-10 V B + 0-0/ B 4-0 ma B4 + 1 VDC 1 VDC B5 Sensor 80 ma 80 ma power B6 supply <A> <1A> Sensor power supply Relay Outputs <C1> C1 C C C4 C5 C6 Relay Outputs <C> C1 C COM C C4 C5 COM C6 BCD (NPN Open Collector): <BCD> Applicable Connector (Sold separately) DR-E50MAG1 (ONDA TSUSIN KOGYO CO., TD.) Special Cable (Sold separately) K-BCD (OMRON) (DR-E50MAG1 with 0.-m cable) PASS C C4 C5 COM C6 Transistor Outputs <T1> <T> C1 C NPN PNP DeviceNet Connector (Included) <DRT> 1 4 5 1: V (Power supply cable: Black) : CAN (Communications cable: Blue) : Shield 4: CAN (Communications cable: White) 5: V+ (Power supply cable: Red) Applicable Connector: R1-5.08P-5SC (01) (IROSE EECTRIC CO., TD.) * Attach the provided crimp terminals. B1 B B The BCD COMMON is shared. The pins indicated in the above diagram as blank (white) boxes have been removed. * Only one of the following can be used for each Digital Indicator: communications, BCD, or DeviceNet. B (+) A ( ) B (+) A ( ) 1 VDC 80 ma 1 VDC 80 ma RS-485 <FKA> SD RD SG 1 VDC 80 ma RS-C <FK1A> B4 + B5 Sensor power B6 supply <A> Sensor power supply + communications B1 B B B4 + B5 Sensor power B6 supply Contact Outputs 5 V PASS Transistor Outputs (NPN Open Collector) Safety Standards Conformance Always use a EN/IEC-compliant power supply with reinforced insulation or double insulation for the DeviceNet power supply. The product must be used indoors for the above applicable standards to apply. PASS 8

E Pulse Inputs Up/Down Counting Pulse Meter: NPN Input: KB-@NB Input A E1 Voltage E NPN E COM Input B E4 Voltage E5 NPN E6 COM Note: E and E6, as well as B6, are internally connected. PNP Input: KB-@PB E1 Input A E PNP E COM E4 Input B E5 PNP E6 COM Note: E and E6, as well as B5, are internally connected. D Event Inputs NPN Input Model NPN input section E, E5 COM E, E6 1 V 510 Ω 700 Ω Note: A -wire DC sensor can also be connected. Check the ratings and characteristics tables, however, for the connection conditions. Voltage pulse input section 1 V 510 Ω E1, E4 10 kω 700 Ω E, E6 Models with Terminal Blocks <1> <> OD RESET COMPENSATION COM Models with Connectors <> <4> 1: : S-TMR 1 : OD 4: RESET 5: COMPENSATION 6: COM 7: BANK4 8: BANK 9: BANK1 9 10 10: COM Applicable Connector (Sold separately) XG4M-100 (OMRON) Special Cable (Sold separately) K-DICN (OMRON) (XG4M-100 with -m cable) Note: The actual terminal label abbreviates "COMPENSATION" to "CMP." Use terminal pin D6 as the common terminal. Use NPN open collector or no-voltage contacts for event input. PNP types are also available. OD: D RESET: D4 COMPENSATION: D5 D6 COM 1 V 4.7 kω.9 kω BCD Output Cable Model Shape Pin arrangement K-BCD Note: The BCD Output Cable has a D-sub plug. Cover: 17JE-7-1A (manufactured by DDK); Connector: equivalent to 17JE-70-0 (D1) (manufactured by DDK) Special Cable (for Event Inputs with 8-pin Connector) Model Appearance Wiring K-DICN KB end Connected device end (PC, display device, etc.) 00 mm 8 mm 46.5 mm Cover: DR-E50PA5 (manufactured by onda Tsushin Co., td.) Connector: DR-E50MAG1 (manufactured by onda Tsushin Co., td.) 9 10 1,000 mm Cable marking ( m) D-sub connector (7-pin female) Cover: 17JE-7-1A (manufactured by DDK) Connector: Equivalent to 17JE-170-0 (manufactured by DDK) Stud: 17-00A (manufactured by DDK) Pin No. 1 4 5 6 7 8 9 10 Signal name S-TMR OD RESET COM BANK4 BANK BANK1 COM COMMON 1 0 4 1 10 1 8 4 10 0 OVER 4 4 DATA VAID 8 5 4 RUN 1 6 5 COMMON 10 1 7 6 REQUEST 4 8 7 MAX REQ. 8 9 8 MIN REQ. 1 10 9 OD 10 11 0 RESET 4 1 1 POARITY 8 1 1 14 10 15 4 PASS 4 16 5 8 17 6 10 4 1 18 7 COMMON 19 9

Derating Curve for Sensor Power Supply (Reference Values) For 1V Maximum current (ma) 140 10 100 80 1 60 40 0 0 0 10 0 10 0 0 40 50 60 Ambient temperature ( C) Note: 1. The above values were obtained under test conditions with the standard mounting. The derating curve will vary with the mounting conditions, so be sure to adjust accordingly.. Internal components may be deteriorated or damaged. Do not use the Digital Indicator outside of the derating range (i.e., do not use it in the area labeled A, above). Internal Block Diagram Pulse input Pulse input Waveform shaping Keys EEPROM Indications BCD I/O Event input BCD Input Output Transistor output Digital input Drive Waveform shaping Microcomputer Drive Drive X Transistor output Relay output inear output inear output Drive Drive DeviceNet DeviceNet Sensor power supply Filter Drive Communications driver Communications VO VDD VCOM Power supply (isolated) VO DC-DC Converter (isolated) Power supply 10

BCD Output Timing Chart A REQUEST signal from a Programmable Controller or other external device is required to read BCD data. Single Sampling Data Output Continuous Data Output REQ. MAX.MIN. DATA DATA VAID All data "igh" Approx. 0 ms 0-ms pulse min. (50 ms max.) Data 40 ms 16 ms All data "igh" The data is set in approximately 0 ms from the rising edge of the REQUEST signal and the DATA VAID signal is output. When reading the data from a Programmable Controller, start reading the data when the DATA VAID signal turns ON. The DATA VAID signal will turn OFF 40 ms later, and the data will turn OFF 16 ms after that. REQ. MAX.MIN. DATA DATA VAID All data "igh" Approx. 0 ms The KB BCD output model has an open collector output, so wired OR connection is possible Data 1 Data 40 ms 4 ms 40 ms 4 ms 64 ms 64 ms Measurement data is output every 64 ms while the REQUEST signal remains ON. Note: If OD is executed when switching between data 1 and data, either data 1 or data is output depending on the timing of the hold signal. The data will not go OW. KB (1) KB () KB () Programmable Controller DATA (including PO and OVER) and DATA VAID can be used in a wired OR. RUN,,, PASS,, and are always output, with or without a REQUEST signal. Do not used a wired OR connect for these signals. REQ. (1) REQ. () REQ. () DATA DATA VAID (1) () () (See note.) (See note.) (See note.) Note: eave 0 ms min. between DATA VAID turning OFF and the REQUEST signal. Programmable Controller Connection Example Digital Indicator SYSMAC Programmable Controller Connector pin No. (See note.) DC Input Unit 1.COMMON.1 COM IN Display Unit Connection Example Digital Indicator Connector pin No. (See note.) 1.COMMON.1. 4.4 5.8 10 IN IN IN Internal. 4.4 5.8 10.DATA VAID 4.RUN IN.DATA VAID 4.RUN IN To 10 1 To 10 +5 V 40 Ω 40 Ω 40 Ω 40 Ω 5.COMMON 6.REQUEST 0.RESET 1.POARITY (+/ polarity) OUT OUT COM (0 V) 4 VDC Transistor Output Unit Internal Internal +5 V 40 Ω 40 Ω 40 Ω 40 Ω 5.COMMON 6.REQUEST 0.RESET 1.POARITY (+/ polarity) Short V OD 8 C BA DP E V OD 8 C BA DP E V OD M7E-01D@N, 01@N 8 C BA DP E V O SEC +4 V 0 V DC power supply <M7E Digital Display Unit> Note: The BCD output connector pin number is the D-sub connector pin number when the BCD Output Cable (sold separately) is connected. This number differs from the pin number for the Digital Indicator narrow pitch connector (manufactured by onda Tsushin Kogyo Co., td.). Refer to the following User's Manual for application precautions and other information required when using the Digital Indicator: KB-R/P/C Digital Indicator User's Manual (Cat. No. N16) The manual can be downloaded from the following site in PDF format: OMRON Industrial Web http://www.fa.omron.co.jp 11

Component Names and Functions Max./Min. status indicator Turns ON when the maximum value or minimum value is displayed in the RUN level. evel/bank display In RUN level, displays the bank if the bank function is ON. (Turns OFF if the bank function is OFF.) In other levels, displays the current level. PV display Displays PVs, maximum values, minimum values, parameter names, and error names. Position meter Displays the position of the PV with respect to a desired scale. Comparative output status indicators Display the status of comparative outputs. Status indicators Max Min P B CMW old T SV display Displays SV and monitor values. SV display status indicators Display Function it when communications writing is ON CMW (enabled) and not lit when OFF (prohibited). Turns ON/OFF when hold input turns old ON/OFF. MAX/MIN EVE MODE SIFT UP 5 4 T 1 Indicator T 5, 4,,, 1 Function Turns ON when parameters for which teaching can be performed are displayed. In RUN level, turn ON when the comparative set value 1,,, 4, or 5 is displayed. MAX/MIN Key EVE Key MODE Key SIFT Key UP Key Used to switch the display between the PV, maximum value, and minimum value and to reset the maximum and minimum values. Used to switch level. Used to switch the parameters displayed. Used to change parameter settings. When changing a set value, this key is used to move along the digits. When changing a set value, this key is used to change the actual value. When a measurement value is displayed, this key is used to execute or clear the forced-zero function or to execute teaching. 1

Dimensions 101. 91 Terminal cover (included) Character Size for Main Display (mm) PV display SV display 14. 4.9 Panel Cutout Dimensions 10 min. 100 (11) 7.6.5 75 min. 9 +0.8 0 96 1 1. 95 * 45 +0.6 0 48 44.8 Wiring Precautions For terminal blocks, use the crimp terminals suitable for M screws. Tighten the terminal screws to the recommended tightening torque of approx. 0.5 N m. To prevent inductive noise, separate the wiring for signal lines from that for power lines. Wiring Use the crimp terminals suitable for M screws shown below. *DeviceNet models: 97 mm Terminal: M, Terminal Cover: Accessory Mounting Method 1. Insert the KB into the mounting cutout in the panel.. Insert watertight packing around the Unit to make the mounting watertight. Watertight packing 5.8 mm max. 5.8 mm max. Unit Stickers (included) No unit stickers are attached to the Digital Indicator. Select the appropriate units from the unit sticker sheets provided.. Insert the adapter into the grooves on the left and right sides of the rear case and push until it reaches the panel and is fixed in place. Adaptor CD Field of Vision The KB is designed to have the best visibility at the angles shown in the following diagram. Note: For measurements for commercial purposes, be sure to use the unit required by any applicable laws or regulations. 10 0 Rubber Packing (Sold Separately) K-P1 If the rubber packing is lost or damaged, it can be ordered using the following model number: K-P1. (Depending on the operating environment, deterioration, contraction, or hardening of the rubber packing may occur and so, in order to ensure the level of waterproofing specified in NEMA4, periodic replacement is recommended.) Note: Rubber packing is provided with the Controller. 1

Main Functions Main Functions and Features Measurement Function The KB-R has the following six functions for receiving and displaying input pulses. F1: Rotation (rpm)/circumferential speed F: Absolute ratio F: Error ratio F4: Rotational difference F5: Flow rate ratio F6: Passing time The KB-P has the following six functions for receiving and displaying input pulses. F1: Passing speed F: Cycle F: Time difference F4: Time band F5: Measuring length F6: Interval The has the following three functions for receiving and displaying input pulses. F1: Individual inputs F: Phase differential inputs F: Pulse counting input Filters Input Types Specify the types of sensor connected to input A and input B. Compensation Compensation func in-ta, in-tb, in-ta compn, com-p The display can be changed to a preset compensation value using the compensation input. Outputs Comparative Output Pattern out-p Zone and level comparative output patterns can be selected for comparative outputs. Output OFF Delay Delays turning OFF comparatives for a set period. This can be used to provide sufficient time to read the comparative output ON status when the comparative result changes at short intervals. Shot Output Turns ON the comparative output for a specific time. Output ogic Reverses the output logic of comparative results. Output Test Output operation can be checked without using actual input signals by using the keys to set a test measurement value. inear Outputs A current or voltage proportional to the change in the measurement value can be output. Standby Sequence off-d shot out-n test lset.c, lset.v, lset.h, lset.l stdby The comparison outputs can be kept OFF until the measurement value enters the PASS range. Key Operations Teaching The present measurement value can be used as a scaling value. Key Protection Key protection restricts level or parameter changes using the keys to prevent unintentional key operations and malfunctions. 14

Display Display Value Selection The display value can be set to the present value, the maximum value, or the minimum value. Display Color Selection The present value display color can be set to green or red. The color of the present value can also be switched according to the comparative output. Display Refresh Period disp color d.ref When the input changes rapidly, the display refresh period can be lengthened to control flickering and make the display easier to read. Other Bank Selection Switch between 8 comparative value banks using the keys on the front panel or external inputs. A set of set comparative values can be selected as a group. Bank Copy Any bank settings can be copied to all banks. Interruption Memory bnk - c c opy memo The measured value can be recorded when the power supply is interrupted. Position Meter pos - t, pos - h, pos - l The present measurement value c an be displayed as a position in relation to the scaling width on a 0-gradation position meter. Prescale ps.ax, ps.ay, ps.bx, ps.by The input signal can be converted and displayed as any value. Comparative Set Value Display sv.dsp Select whether or not to display the comparative value during operation. Display auto-return ret Automatically returns the display to RUN level when there are no key operations (e.g., max./min. switching, bank settings using keys). A DIMENSIONS SOWN ARE IN MIIMETERS. To convert millimeters into inches, multiply by 0.0 97. To convert grams into ounces, multiply by 0.057. In the interest of product improvement, specif ications are subject to change without notice. Authorised Distributors:- AS & AAIN INDIA PVT TD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-4797575 Fax : 011-4797574 E-mail : sales@ashalain.com 15