LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

Similar documents
LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

VW3A4554 line/motor choke - 1 mh - 31 A - 3 phases - 90 W - for variable speed drive

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Characteristics 5 TeSys k contactors and reversing contactors

ZBRT2 double actions (up/down) transmitter for wireless and battery less pushbutton

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

VW3A4552. Price* : USD. ATV31CU22N4 - motor choke - 1 per drive. ATV31CU22N4 - line choke - 1 per drive

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Modular equipment. Presentation, standards. Standard contactors TeSys GC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

Motor starters. TeSys E. Designed for the essential

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

VW3A4556 line choke mh A - 3 phases W - for variable speed drive

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

NS..S contactor relays - with spring terminals AC operated

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

3 - Protection components Circuit-breakers

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

RENF22R2MMW Zelio Timer Relay - Modular

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

Components for safety applications

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

Protection components

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Electromechanical pressure and vacuum switches 0

LXM32AD18M2 motion servo drive - Lexium 32 - single phase supply voltage 115/230V - 0.5/1kW

Protection components

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

LXM32AD72N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Pendant control stations 6

References 1 for asynchronous motors 1

Zelio Control Measurement Relays

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

TeSys H. Protection. Motor controllers. Reliable. Motor starters. Contactors. Circuit breakers. Smart. Ultra-compact 22.5 mm motor starters

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

38 Series - Relay interface modules A. Features /

48 Series - Relay interface modules A. Features

Pendant control stations 6

Pendant control stations 6

Zelio Plug-In Relays. RXG interface relays. Catalog

Page 13-2 Page Page 13-7

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights

Type CP-S, CP-C & CP-A Switch mode

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.

Complete units: Mushroom heads ø 22mm

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Classification Enclosure rating Contact form Contact material

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Transcription:

Product data sheet Characteristics LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 215.00 USD Main Range Product name Product or component type Device short name Contactor application Utilisation category Poles description Power pole contact composition System Voltage [Ie] rated operational current Motor power kw Motor power HP (UL / CSA) Control circuit type [Uc] control circuit voltage Auxiliary contact composition TeSys TeSys D Contactor LC1D Motor control Resistive load AC-1 AC-3 AC-4 3P 3 NO <= 300 V DC power circuit <= 690 V AC 25...400 Hz power circuit 32 A (<= 140 F (60 C)) at <= 440 V AC AC-3 power circuit 50 A (<= 140 F (60 C)) at <= 440 V AC AC-1 power circuit 15 kw at 380...400 V AC 50/60 Hz AC-3 7.5 kw at 220...230 V AC 50/60 Hz AC-3 18.5 kw at 500 V AC 50/60 Hz AC-3 18.5 kw at 660...690 V AC 50/60 Hz AC-3 15 kw at 415...440 V AC 50/60 Hz AC-3 7.5 kw at 400 V AC 50/60 Hz AC-4 2 hp at 115 V AC 50/60 Hz 1 phase motors 5 hp at 230/240 V AC 50/60 Hz 1 phase motors 7.5 hp at 200/208 V AC 50/60 Hz 3 phases motors 10 hp at 230/240 V AC 50/60 Hz 3 phases motors 20 hp at 460/480 V AC 50/60 Hz 3 phases motors 30 hp at 575/600 V AC 50/60 Hz 3 phases motors DC standard 48 V DC 1 NO + 1 NC [Uimp] rated impulse withstand voltage 6 kv conforming to IEC 60947 Mar 16, 2019 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Overvoltage category [Ith] conventional free air thermal current III 50 A at <= 140 F (60 C) power circuit 10 A at <= 140 F (60 C) signalling circuit Irms rated making capacity 550 A at 440 V power circuit conforming to IEC 60947 140 A AC signalling circuit conforming to IEC 60947-5-1 250 A DC signalling circuit conforming to IEC 60947-5-1 Rated breaking capacity 550 A at 440 V power circuit conforming to IEC 60947 [Icw] rated short-time withstand current Associated fuse rating Average impedance [Ui] rated insulation voltage Electrical durability Power dissipation per pole Safety cover Mounting support 138 A <= 104 F (40 C) 1 min power circuit 260 A <= 104 F (40 C) 10 s power circuit 430 A <= 104 F (40 C) 1 s power circuit 60 A <= 104 F (40 C) 10 min power circuit 100 A 1 s signalling circuit 120 A 500 ms signalling circuit 140 A 100 ms signalling circuit 63 A gg at <= 690 V coordination type 1 power circuit 63 A gg at <= 690 V coordination type 2 power circuit 10 A gg signalling circuit conforming to IEC 60947-5-1 2 mohm at 50 Hz - Ith 50 A power circuit 600 V power circuit certifications CSA 600 V power circuit certifications UL 690 V power circuit conforming to IEC 60947-4-1 690 V signalling circuit conforming to IEC 60947-1 600 V signalling circuit certifications CSA 600 V signalling circuit certifications UL 1.65 Mcycles 32 A AC-3 at Ue <= 440 V 1.4 Mcycles 50 A AC-1 at Ue <= 440 V 2 W AC-3 5 W AC-1 With Plate Rail Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 Product certifications Connections - terminals BV CCC CSA DNV GL GOST LROS (Lloyds register of shipping) RINA UL Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end Power circuit: screw clamp terminals 1 cable(s) 0...0.02 in² (1.5...10 mm²) - cable stiffness: solid - Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable end Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - Power circuit: screw clamp terminals 1 cable(s) 0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible - Power circuit: screw clamp terminals 2 cable(s) 0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible - Power circuit: screw clamp terminals 1 cable(s) 0...0.02 in² (1...10 mm²) - cable stiffness: flexible - with cable end Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1.5...6 mm²) - cable stiffness: flexible - with cable end 2

Tightening torque Operating time Power circuit: screw clamp terminals 2 cable(s) 0...0.02 in² (2.5...10 mm²) - cable stiffness: solid - Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 22.12 lbf.in (2.5 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm Power circuit: 22.12 lbf.in (2.5 N.m) - on screw clamp terminals - with screwdriver Philips No 2 53.55...72.45 ms closing 16...24 ms opening Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Mechanical durability Operating rate 30 Mcycles 3600 cyc/h at <= 140 F (60 C) Complementary Coil technology Control circuit voltage limits Time constant Inrush power in W Hold-in power consumption in W Built-in bidirectional peak limiting diode suppressor 0.1...0.25 Uc drop-out at 140 F (60 C), DC 0.7...1.25 Uc operational at 140 F (60 C), DC 28 ms 5.4 W at 68 F (20 C) 5.4 W at 68 F (20 C) Auxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1 Type mirror contact (1 NC) conforming to IEC 60947-4-1 Signalling circuit frequency Minimum switching current Minimum switching voltage Non-overlap time Insulation resistance 25...400 Hz 5 ma signalling circuit 17 V signalling circuit 1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact > 10 MOhm signalling circuit Environment IP degree of protection IP20 front face conforming to IEC 60529 Protective treatment TH conforming to IEC 60068-2-30 Pollution degree 3 Ambient air temperature for operation Ambient air temperature for storage Permissible ambient air temperature around the device Operating altitude 23...140 F (-5...60 C) -76...176 F (-60...80 C) -40...158 F (-40...70 C) at Uc 9842.52 ft (3000 m) without derating in temperature Fire resistance 1562 F (850 C) conforming to IEC 60695-2-1 Flame retardance V1 conforming to UL 94 Mechanical robustness Height Width Depth Product weight Vibrations contactor open 2 Gn, 5...300 Hz Vibrations contactor closed 4 Gn, 5...300 Hz Shocks contactor closed 15 Gn for 11 ms Shocks contactor open 8 Gn for 11 ms 3.35 in (85 mm) 1.77 in (45 mm) 3.98 in (101 mm) 1.18 lb(us) (0.535 kg) Ordering and shipping details Category 22345 - CTR,D-LINE,OPEN,NONREV-NEW Discount Schedule I12 GTIN 003389110357363 Nbr. of units in pkg. 1 Package weight(lbs) 1.1400000000000001 Returnability N 3

Country of origin FR Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Green Premium product Compliant - since 0627 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Product environmental profile Available Product end of life instructions Available California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. - - - - - - - More information For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months 4

Product data sheet Dimensions Drawings LC1D32ED Dimensions (1) Minimum electrical clearance LC1 D25 D38 D183 D323 b 85 99 c without cover or add-on blocks 99 99 with cover, without add-on blocks 101 101 c1 with LAD N or C (2 or 4 contacts) 132 132 c2 with LA6 DK10 144 144 c3 with LAD T, R, S 152 152 with LAD T, R, S and sealing cover 156 156 5

Product data sheet Connections and Schema LC1D32ED Wiring 6