Estimating Frequency Response Characteristics of Human Baroreflex System

Similar documents
Spectral Analysis and Heart Rate Variability: Principles and Biomedical Applications. Dr. Harvey N. Mayrovitz

Arterial pulse waves measured with EMFi and PPG sensors and comparison of the pulse waveform spectral and decomposition analysis in healthy subjects

Biosignal filtering and artifact rejection, Part II. Biosignal processing, S Autumn 2017

Relation between HF HRV and Respiratory Frequency

Chapter 5. Frequency Domain Analysis

UNIVERSITY OF CALGARY DEPARTMENT OF ELECTRICAL & COMPUTER ENGINEERING BIOMEDICAL SIGNAL ANALYSIS ENEL 563

HIGH FREQUENCY FILTERING OF 24-HOUR HEART RATE DATA

6.555 Lab1: The Electrocardiogram

Biosignal filtering and artifact rejection. Biosignal processing I, S Autumn 2017

Bivariate phase-rectified signal averaging a novel technique for cross-correlation analysis in noisy nonstationary signals

A Tool and Methodology for AC-Stability Analysis of Continuous-Time Closed-Loop Systems

Analysis and Design of Autonomous Microwave Circuits

FOURIER analysis is a well-known method for nonparametric

Chapter 4 SPEECH ENHANCEMENT

Large-scale cortical correlation structure of spontaneous oscillatory activity

Variations in breathing patterns increase low frequency contents in HRV spectra

Frequency Domain Analysis for Assessing Fluid Responsiveness by Using Instantaneous Pulse Rate Variability

FOR PROOFREADING ONLY

Figure S3. Histogram of spike widths of recorded units.

Real-time digital signal recovery for a multi-pole low-pass transfer function system

Amplitude Modulation Effects in Cardiac Signals

Wavelet analysis of blood flow dynamics: effect on the individual oscillatory components of iontophoresis with neutral electrolytes

(i) Understanding the basic concepts of signal modeling, correlation, maximum likelihood estimation, least squares and iterative numerical methods

2 TD-MoM ANALYSIS OF SYMMETRIC WIRE DIPOLE

Introduction. Chapter Time-Varying Signals

Noise estimation and power spectrum analysis using different window techniques

Fundamentals of Time- and Frequency-Domain Analysis of Signal-Averaged Electrocardiograms R. Martin Arthur, PhD

Temperature Control in HVAC Application using PID and Self-Tuning Adaptive Controller

Interface Electronic Circuits

Biosignal Analysis Biosignal Processing Methods. Medical Informatics WS 2007/2008

White-light interferometry, Hilbert transform, and noise

Low-Frequency Transient Visual Oscillations in the Fly

A Study on Correlation of AE Signals from Different AE Sensors in Valve Leakage Rate Detection

New Features of IEEE Std Digitizing Waveform Recorders

PHYSIOLOGICAL DE-NOISING FMRI DATA. Katie Dickerson & Jeff MacInnes February 11th, 2013

Measurement System for Acoustic Absorption Using the Cepstrum Technique. Abstract. 1. Introduction

Biomedical Signals. Signals and Images in Medicine Lecture 1 Dr Nabeel Anwar

A FEEDFORWARD ACTIVE NOISE CONTROL SYSTEM FOR DUCTS USING A PASSIVE SILENCER TO REDUCE ACOUSTIC FEEDBACK

Improved direct torque control of induction motor with dither injection

DIGITAL FILTERING OF MULTIPLE ANALOG CHANNELS

ON WAVEFORM SELECTION IN A TIME VARYING SONAR ENVIRONMENT

EE 791 EEG-5 Measures of EEG Dynamic Properties

Construction of a High-Pass Digital Filter From a Low-Pass Digital Filter

SOUND QUALITY EVALUATION OF FAN NOISE BASED ON HEARING-RELATED PARAMETERS SUMMARY INTRODUCTION

System Identification & Parameter Estimation

Chapter 5 Window Functions. periodic with a period of N (number of samples). This is observed in table (3.1).

LAB 4: OPERATIONAL AMPLIFIER CIRCUITS

Experiment 1: Amplifier Characterization Spring 2019

Experiment 7: Frequency Modulation and Phase Locked Loops

Using Rank Order Filters to Decompose the Electromyogram

Phase Synchronization of Two Tremor-Related Neurons

Introduction to Electronic Circuit for Instrumentation

Site-specific seismic hazard analysis

Biosignal filtering and artifact rejection. Biosignal processing, S Autumn 2012

A Low-Cost Programmable Arbitrary Function Generator for Educational Environment

Changing the sampling rate

Appendix. Harmonic Balance Simulator. Page 1

Developing a Versatile Audio Synthesizer TJHSST Senior Research Project Computer Systems Lab

Lab 8. Signal Analysis Using Matlab Simulink

One-Dimensional FFTs. Figure 6.19a shows z(t), a continuous cosine wave with a period of T 0. . Its Fourier transform, Z(f) is two impulses, at 1/T 0

Comparison of Signal Attenuation of Multiple Frequencies Between Passive and Active High-Pass Filters

IIR Ultra-Wideband Pulse Shaper Design

DYNAMIC LOAD SIMULATOR (DLS): STRATEGIES AND APPLICATIONS

ESA400 Electrochemical Signal Analyzer

Advanced Digital Signal Processing Part 2: Digital Processing of Continuous-Time Signals

Supporting Text Signal Conditioning.

ELECTROMYOGRAPHY UNIT-4

X. MODULATION THEORY AND SYSTEMS

Response spectrum Time history Power Spectral Density, PSD

Evoked Potentials (EPs)

Operational amplifiers

Chapter 2. Signals and Spectra

Spatial coherency of earthquake-induced ground accelerations recorded by 100-Station of Istanbul Rapid Response Network

Computer Evaluation of Exercise Based on Blood Volume Pulse (BVP) Waveform Changes

Electronic Noise Effects on Fundamental Lamb-Mode Acoustic Emission Signal Arrival Times Determined Using Wavelet Transform Results

A multi-window algorithm for real-time automatic detection and picking of P-phases of microseismic events

Lab #9: Compound Action Potentials in the Toad Sciatic Nerve

Real-time fundamental frequency estimation by least-square fitting. IEEE Transactions on Speech and Audio Processing, 1997, v. 5 n. 2, p.

ARTIFICIAL GENERATION OF SPATIALLY VARYING SEISMIC GROUND MOTION USING ANNs

Blood Flow Analysis Using Ultrasound Doppler Technique

Laboratory Activities Handbook

Spectrum Analysis - Elektronikpraktikum

Analysis of room transfer function and reverberant signal statistics

Biomedical Signal Processing and Applications

Biomedical Engineering Evoked Responses

UNIT-3. Electronic Measurements & Instrumentation

Determination of instants of significant excitation in speech using Hilbert envelope and group delay function

USE OF WHITE NOISE IN TRACE/PARCS ANALYSIS OF ATWS WITH INSTABILITY

Implementation of decentralized active control of power transformer noise

Laboratory Assignment 5 Amplitude Modulation

IOMAC' May Guimarães - Portugal

A SIMPLE APPROACH TO DESIGN LINEAR PHASE IIR FILTERS

Laboratory Experiment #1 Introduction to Spectral Analysis

Accurate Identification of Periodic Oscillations Buried in White or Colored Noise Using Fast Orthogonal Search

CSE 3215 Embedded Systems Laboratory Lab 5 Digital Control System

System on a Chip. Prof. Dr. Michael Kraft

Noise Reduction Technique for ECG Signals Using Adaptive Filters

ELECTRICAL CURRENT FOR PAIN CONTROL

Theory of Telecommunications Networks

Digital Signal Processing

Transcription:

Estimating Frequency Response Characteristics of Human Baroreflex System Suchart Kiewnok and Thaweesak Yingthawornsuk Abstract- The existence of feedback loop in the baroreflex system makes it difficult to determine the open-loop transfer function characteristic of the central arc by which blood pressure (BP) modulates sympathetic nerve activity (SNA) and the peripheral arc by which SNA modulates BP. Random aortic pressure perturbation and electrical stimulation of aortic depressor nerve have been proposed to identify these open-loop characteristics under closedloop conditions in animals, but are limited of application in humans. We explored the random breathing technique to identify open-loop characteristics under closed-loop condition in 0 healthy subjects (7m/3f 27±2years, ±S.E.). Random interval breathing (RB) can perturb BP with white noise characteristics over the physiologically relevant frequency range of 0.0-0.3 Hz. We measured the muscle SNA of the peroneal nerve and the continuous BP. The peripheral arc transfer function (SNA >BP) could be approximated by a secondorder low-pass filter and the fitted parameters of dynamic gain, natural frequency, damping ratio, and lag time were.2±0.35, 0.06±0.0 Hz, 0.49±0.4, and.05±0.26 s, respectively. The central arc transfer function (BP >SNA) could be approximated by a firstorder high-pass filter and the fitted parameters of dynamic gain, corner frequency, and lag time were.75±0.28, 0.7±0.04 Hz, and 0.57±0.8 s, respectively. In conclusion, the proposed random breathing technique is an useful tool of assessment in human autonomic nervous system for identification of open-loop transfer functions in the closed-loop baroreflex system. I Keywords- Baroreflex, RB, SNA, BP I. INTRODUCTION N the circulatory system, a change in carotid sinus pressure causes a carotid sinus baroreflex control mediated alteration of efferent sympathetic nerve activity. This also modulates arterial pressure []. The existence of this feedback loop in the baroreflex system makes its openloop transfer function difficult to be determined by s of conventional frequency domain approaches based on the Fourier transformation. The broad-band respiratory perturbation is one of the most extensively studied influences on human autonomic nervous system [5]. Suchart Kiewnok is from Department of Electrical Technology Education, King Mongkut's University of Technology Thonburi, Thailand. Thaweesak Yingthawornsuk is with Department of Media Technology, King Mongkut's University of Technology Thonburi, Thailand The characteristics of baroreflex system can be noninvasively determined over a wide range of physiologically relevant frequencies. The closed feedback loop of carotid sinus baroreflex system can be generally decomposed into two major arcs, central arc and peripheral arc. The estimated transfer function from carotid sinus pressure to efferent sympathetic nerve activity would represent the frequency response characteristic of central arc. The estimated transfer function from efferent sympathetic nerve activity to arterial pressure would represent the frequency response characteristic of peripheral arc. This study was proposed to estimate the open-loop transfer function characteristics of human carotid sinus baroreflex system under closed-loop condition by using random breathing as an exogenous perturbation. This perturbation technique makes it possible to identify the openloop transfer function characteristics of baroreflex control with the closed-loop identification method [8]. II. METHODOLOGY We studied ten volunteers (7males/3females, 27±2years, ±S.E.) in resting supine position. Instantaneous lung volume, muscle sympathetic nerve activity, and blood pressure were measured during a period of random breathing perturbation for at least six minutes after recording base line. Broad-band respiration activity is elicited by instructing volunteers to follow triangular waveforms with their inspiration and expiration. The dept and duration of respiration are randomly selected on the IBM laptop screen. In the closedloop identification protocol, we perturbed the carotid sinus baroreflex according to random breathing with the broadened frequencies between 0.0 Hz and 0.3 Hz [5]. Signals were digitized by a 4-bit analog-to- digital converter with a sampling rate of 500 Hz per channel. The muscle sympathetic nerve activity was measured using a pair of tungsten microelectrodes inserted percutaneously into the peroneal nerve at the fibular head. Details regarding of this technique has been published previously [6]. The pre-amplified nerve signal was full-wave rectified and then was integrated by a resistance-capacitor circuit with a time constant of 0. s. The smoothed envelope of nerve signal was referred as integrated muscle sympathetic nerve activity (IMSNA). Since the absolute voltage of nerve activity depends on various physiological conditions such as positioning of the electrodes and size of the nerves, we expressed the amplitude of IMSNA in arbitrary unit (a.u.). 2

A. Data Analysis The recorded data were normalized to reduce the difference of amplitude scale. The normalized data were analyzed starting at minute after the onset of the perturbation. We then resampled the data at 0 Hz with an anti-aliasing filter. The 6-min resampled data were then subdivided into 50% overlapping bins of,024 data points (02.4 s) per segment [8]. The linear trend removal and Harming window were applied to each segment before subsequent calculation of the open-loop transfer functions. We applied Fourier transformation and obtained power spectra of blood pressure [BP(f)], integrated muscle sympathetic nerve activity [SNA(f)], and random breathing [RB(f)]. The crosspower spectra between signals were calculated for each segment and then ensemble-averaged over segments to reduce spectral variance [7]. The coherence between BP and SNA was also estimated. B. Closed-Loop Identification Figure schematizes the closed-loop system where the aortic pressure is directly propagated to the carotid sinus baroreceptors. This system identification relies on an exogenous perturbation. This approach has been popularly used to demonstrate in animal model study [8] and in humans [3]. In this framework, the equations of sympathetic nerve activity and blood pressure can be written as SNA(f) = H (f) BP(f) + U(f) () BP(f) = H 2 (f) SNA(f) + V(f) + H x (f) RB(f) (2) Because E[S U.RB (f)] converges to zero by virtue of the white-noise nature of RB(f), we can obtain an unbiased estimate of Hi(f) as follow. H (f) E[S E[S SNA RB (4) BP RB Once we obtain H (f), we can estimate U(f) from equation and H 2 (f) can be estimated as the following equation. H (f ) 2 E[SBP U (5) E[SSNA U III. RESULTS The actual recordings obtained from one volunteer are shown in Figure 2. The magnitudes of power spectral density of random respiratory signal were fairly constant up to 0.3 Hz and diminished to noise level at higher frequencies as shown in Figure 3. So, we estimated the open-loop transfer functions of the baroreflex system up to 0.3 Hz. In Figure 4, the coherence is above 0.5 along frequency range from 0.02 Hz to 0.25 Hz, Calculating the ensemble average of crosspower spectra between terms of equation and RB(f). We have, V(f) H x (f BP(f) RB(f) H (f) H 2 (f) U(f) SNA(f) Fig.. Closed-loop identification in frequency domain. H (f) and H 2 (f) represent the central and peripheral arc transfer functions, respectively. SNA(f), BP(f), and RB(f) represent Fourier transforms of sympathetic nerve activity, blood pressure, and random respiration, respectively. U(f) and V(f) represent unknown internal noises in SNA(f) and BP(f), respectively. H x (f) denotes transfer function from perturbation RB(f) to BP(f). E[S SNA RB (f)] = H (f) E[S BP RB (f)] + E[S U RB (f)] (3) Blood Pressure (mmhg) Respiration 2 0 - -2 0 20 40 60 80 00 200 60 20 80 40 0 0 20 40 60 80 00 22

Integrated MSNA 700 00000 IMSNA(arb. unit) 500 300 00-00 0000 000 00 0 20 40 60 80 00 0 0.00 0.0 0. Figure 2. Measured random respiration (top), blood pressure (middle), and integrated muscle sympathetic nerve activity (bottom) under closed-loop condition random breathing perturbation Figure 4. Mean power spectra of the blood pressure (top) and the integrated muscle sympathetic nerve activity (bottom), respectively. Neural Arc Respiration 000 0000 00 000 00 0 0 0. 0.0 0.00 0.0 0. subject subject2 subject3 subject4 0. 0.00 0.0 0. Fig. 3. Mean power spectra of the random respiration from fourteen healthy volunteers. 000 00 Blood Pressure 000 00 0 0. 0.0 0.00 0.0 0. 0 0. 0.0 0.00 0.00 0.0 0. subject subject2 subject3 subject4 Figure 5. Transfer functions of four normal volunteers estimated under closed-loop system identification. Neural arc transfer function (top) showed high-pass characteristic in each volunteer, whereas peripheral arc transfer function (bottom) showed low-pass characteristics. Small solid line and bold line indicate individual and values, respectively. 23

A. Model Fitting The estimated central arc transfer function was fitted to a first-order high-pass filter and the estimated peripheral arc transfer function was fitted to a second-order low-pass filter with the iterative nonlinear least-square regression [9]. For the peripheral arc characteristic, the estimated gain, corner frequency, damping ratio, and lag time determined by fitting were. 2 0.35, 0.06 0.0 Hz, 0.49 0.4, and.05 0.26 s,respectively. The estimated gain, corner frequency, and lag time for the central arc characteristic determined by fitting were.75 0.28, 0.7 0.04 Hz, and 0.57 0.8 s, respectively. B. Validation Of Estimation The correlation factor between the calculated power spectra (from estimation function of central arc) and the power spectra of measured SNA was determined. The calculated power spectra of SNA can be found by multiplying the squared open-loop transfer function of central arc with the power spectra of measured BP. We also determined the correlation factor for BP. From the peripheral arc. The coefficients of correlation (0.92 and 0.94 for SNA and BP, respective) were found to be significant at level 0.00 for all fourteen volunteers Magnitude (a.u./mmhg) 00 0 0. 0 H H 2 0.0 0. 0.3 0. 0.0 0.0 0. 0.3 Fig. 6. Model Fittings of central (left) and peripheral (right) arc transfer function. Dashed lines and solid lines indicate estimated open-loop transfer functions and the best fitted model functions, respectively PHASE 000 00 0 0. 0.0 Magnitude ( mmhg/a.u.) 0.00 0.00 0.0 0. 270 20 50 90 30-30 -90-50 -20-270 0.00 0.0 0. SD+ SD- Figure 7. Mean transfer functions of four normal volunteers estimated. Peripheral arc transfer function (top) and phase shift (bottom). Solid lines and dashed line indicate and SD values, respectively. SD+ IV. DISCUSSION It has been shown that the closed-loop nonparametric method with an exogenous perturbation of random breathing could identify the open-loop transfer function reasonably well. The central and peripheral arc transfer functions represent the high-pass and low-pass filter characteristics, respectively. The coherence values were less than unity for all frequencies. This implies that substantially internal noise was present in sympathetic nerve activity in term of linear system relationship. This noise consists of physiological internal fluctuation, nonlinear system responses, and physical noise associated with the recoding process itself. The exogenous perturbation increased variations both in both pressure and sympathetic nerve activity, while not affection the estimation of open-loop transfer function under closed-loop condition is biased by feedback effect of internal noise on SNA and BP. Identification of the peripheral transfer function with the closed-loop identification approach is dependent on the magnitude of unknown internal noise in sympathetic nerve activity. It should be noted that any nonlinear responses of the sympathetic nerve activity to the baroreceptor pressure input can be mathematically treated as the unknown internal noise. Therefore, might be expected to improve the system identification. Several noninvasive techniques have been applied to perturb the baroreflex system: neck suction[2] and lower body negative pressure[4]. Although neck suction causes excitation of the carotid sinus baroreflex, other baroreflex system such as the aortic arc baroreflex would oppose the action of the carotid sinus baroreflex. The method of low body negative pressure is promising as a s of blood pressure perturbation. However, with the lower body negative pressure, the pressure perturbation is imposed on the venous side rather the arterial side. We should investigate the question of identification of arterial baroreflex function using venous perturbations before extrapolating to its utility in the framework of closed-loop system identification V. CONCLUSION The application of the randomized breathing perturbation is useful to identify the open-loop transfer functions of central and peripheral arcs. This nonparametric frequency domain approach allows for investigation of the baroreflex control not only under normal conditions but under the pathophysiological conditions as well. 24

ACKNOWLEDGMENT Authors would like to thank Dr. Thaweesak Yingthawornsuk, Department of Media Technology, KMUTT, for the valuable suggestion on experimental design and discussion on results, and Department of Electrical Technology Education as well for supporting laboratory facilities. REFERENCES [.] Mancia, G., and A.L. Mark. Arterial baroreflex in humans. In: Handbook of Physiology. The Cadiovascular System. Peripheral Circulation and Organ Blood Flow. Bethesda, MD: Am. Physiol. Soc., 983, sect. 2, vol. III, pt.2, chapt. 20, p. 755-794. [2.] Thames, M. D., T. Kinugawa, M. L. Smith, and M. E. Dibner-Dunlap. Abnormalities of baroreflex control in heart failure. J. Am. Coll. Cardiol. 22, Suppl. A: 56A-60A, 993. [3.] Ikeda, Y., T. Kawada, M. Sugimachi, O. Kawaguchi, T. Shishido, T.Sato, H. Miyano, W. Matsuura, J. Alexander, Jr., and K. Sunagawa. Neural arc of baroreflex optimizes dynamic pressure regulation in achieving both stability and quickness. Am. J. Physiol. 27 (Heart Circ. Physiol. 40): H882-H890, 996. [4.] Oppenheim, A. V., and R. W. Schafer. Discrete-Time Signals and Systems. In: Digital signal Processing. Englewood Cliffs, NJ: Prentice- Hall, 975, p.6-44. [5.] Sundlof,G., and B.G. Wallin. The variability of muscle nerve sympathetic activity in resting recumbent man. J. Physiol. Lond. 272: 383-397, 997. 25