EFFECT OF VARIOUS HYSTERETIC MODELS ON SEISMIC FRAGILITIES OF PRECAST INDUSTRIAL BUILDINGS

Similar documents
Effect of Masonry Infills on Seismic Performance of RC Frame Buildings

EXPERIMENTAL AND ANALYTICAL STUDIES ON THE STRENGTHENING OF RC FRAMES

DISTRIBUTION OF EARTHQUAKE INPUT ENERGY IN HIGH RISE BULDINGS WITH VISCOUSLY DAMPED OUTRIGGERS

Nonlinear behavior of Reinforced Concrete Infilled Frames using ATENA 2D

TRAIN INDUCED SEISMIC NOISE OF ACCELERATING AND DECELERATING TRAIN SETS

Heat-Mechanics Interaction Behavior of Laminated Rubber Bearings under Large and Cyclic Lateral Deformation

Shinde Suyog Sudhakar, Galatage Abhijeet.A, Kulkarni Sumant.K, International Journal of Advance Research, Ideas and Innovations in Technology.

Finite Element Study of Using Concrete Tie Beams to Reduce Differential Settlement Between Footings

ANALYSIS OF LATERAL STIFFNESS FOR INFILLED FRAME WITH OPENING

Site-specific seismic hazard analysis

Experimental investigation of the behaviour of pinned beam to column connections to pure shear monotonic and cyclic excitation

Seismic Performance of Brick Infill in RCC Structure

Experimental Study on Pile Groups Settlement and Efficiency in Cohesionless Soil

Effect of Infill Walls on RC Framed Structure

SEISMIC BEHAVIOR OF BEAM-TO-COLUMN DOWEL CONNECTIONS: NUMERICAL ANALYSIS VS EXPERIMENTAL TEST

Dynamic Analysis of Infills on R.C Framed Structures

EFFECTS OF OPENINGS ON COLLAPSE RISK OF INFILED RC BUILDINGS

CODE FORMULA FOR THE FUNDAMENTAL PERIOD OF RC PRECAST BUILDINGS

Cyclic Response of Dowel Connections in Precast Structures

Chapter 13 Tuned-Mass Dampers. CIE Structural Control 1

Preliminary study of the vibration displacement measurement by using strain gauge

Design of structural connections for precast concrete buildings

ANALYSIS ON RESPONSE OF DYNAMIC SYSTEMS TO PULSE SEQUENCES EXCITATION

Prof. Sudhir Misra, Dept of CE (PI) Prof. Samit Raychaudhari, Dept of CE (Co PI) Dr. KK Bajpai, Dept of CE (Co PI)

A novel procedure for evaluating the rotational stiffness of traditional timber joints in Taiwan

International Journal of Science, Engineering and Technology Research (IJSETR), Volume 4, Issue 11, November 2015

THE RELATIONSHIP BETWEEN FILL-DEPTHS BASED ON GIS ESTIMATION, EARTHQUAKE DAMAGE AND THE MICRO-TREMOR PROPERTY OF A DEVELOPED HILL RESIDENTIAL AREA

Modelling of Rebar and Cable Bolt Behaviour in Tension/Shear

ASSESSING THE EFFECTS OF DROPPED OBJECTS ON SUBSEA PIPELINES AND STRUCTURES

Strain Measurements with the Digital Image Correlation System Vic-2D

Designing for Seismic Success with Precast Concrete

Application of Advanced Materials and New Detailing for ABC Column Connections

Seismic Response of Cellwise Braced Reinforced Concrete Frames

SUMMARY SHEETS OF BAR COUPLER CONNECTIONS

Experimental investigation of crack in aluminum cantilever beam using vibration monitoring technique

K L Rakshith, Smitha, International Journal of Advance Research, Ideas and Innovations in Technology.

Module 2 WAVE PROPAGATION (Lectures 7 to 9)

3D Non-Linear FEA to Determine Burst and Collapse Capacity of Eccentrically Worn Casing

Engineering ground motion selection based on displacement-spectrum compatibility

INFLUENCE OF PILES ON LOAD- SETTLEMENT BEHAVIOUR OF RAFT FOUNDATION

EARTHQUAKE EARLY WARNING and RAPID LOSS INFORMATION GENERATION IN ISTANBUL. Mustafa Erdik Boğaziçi University, Istanbul

Dynamic Modeling of Air Cushion Vehicles

A Mathematical Model to Determine Sensitivity of Vibration Signals for Localized Defects and to Find Effective Number of Balls in Ball Bearing

EFFECT OF CHANGING CONFIGURATIONS AND LENGTHS OF PILES ON PILED RAFT FOUNDATION BEHAVIOUR

WP 6: Validation Studies Vienna Test Case

Proposed changes on NZS 3404 specified part-turn method of tensioning high strength friction grip (HSFG) property class 8.8 bolts

Available online at ScienceDirect. Procedia Engineering 125 (2015 )

ANALYSIS OF PILE-RAFT FOUNDATIONS NON- RESTED AND DIRECTLY RESTED ON SOIL

4.0 EXPERIMENTAL RESULTS AND DISCUSSION

EFFECT OF SETBACK RATIO ON SEISMIC PERFORMANCE OF RC STRUCTURES

Journal of American Science 2015;11(8) Soil Nailing For Radial Reinforcement of NATM Tunnels

Study on embedded length of piles for slope reinforced with one row of piles

A Risk Based Approach for the Robustness Assessment of Timber Roofs

Ductility is Damage People Don t want to live in Damaged Buildings Akira Wada Professor Emeritus Tokyo Institute of Technology

Keywords: Bracing bracket connection, local deformation, selective pallet racks, shear stiffness, spine bracings.

Effect of Connection Rigidity on Seismic Response of Precast Concrete Frames

Seismic Response of Cellwise Braced Multistoried Frames

Tutorial: designing a converging-beam electron gun and focusing solenoid with Trak and PerMag

Study on micro extra deep drawing process with ultrahigh fluid pressure and press motion controls

ASSESSMENT OF BASIC STEEL I-SECTION BEAM BRACING REQUIREMENTS BY TEST SIMULATION

Optimum Design of Nailed Soil Wall

Composite Sections. Introduction BETON PRATEGANG TKS Session 10: 2015/4/27

NALYSIS OF STABILIZING SLOPES USING VERTICAL PILES

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 04, 2016 ISSN (online):

INFLUENCE OF STATIC DISPLACEMENT ON PEAK GROUND VELOCITY AT SITES THAT EXPERIENCED FORWARD-RUPTURE DIRECTIVITY

Development of Wooden Portal Frame Structures with Improved Columns

STRUCTURAL HEALTH MONITORING USING STRONG AND WEAK EARTHQUAKE MOTIONS

: STRUCTURAL DYNAMICS. Course Handout

CE2045-PREFABRICATED STRUCTURES QUESTION BANK

Moment Resisting Connections for Load Bearing Walls

Earthquake Resistance Test Specifications for Communications Equipment

Comparison of behaviour of laterally loaded round and squared timber bolted joints

Vibratory Feeder Bowl Analysis

INTERPRETATION OF SCREW PILE LOAD TEST DATA USING EXTRAPOLATION METHOD IN DENSE SAND

Ground Improvement Prof. G. L. Sivakumar Babu Department of Civil Engineering Indian Institute of Science, Bangalore. Lecture No.

Open Access Push-Pull Interface Connections in Steel Frames with Precast Concrete Infill Panels

DEVELOPMENT OF A SIMULATION METHOD FOR EVACUATION BY WHEELCHAIR USING DISTINCT ELEMENT METHOD

Glued laminated timber beams repair.

a) If a bolt is over-tightened, which will fail first the bolt, or the plastic?

Prediction of the Fundamental Periods for Infilled RC Frame Buildings

IOMAC' May Guimarães - Portugal REAL-TIME STRUCTURAL HEALTH MONITORUN AND DAMAG DETECTION

COMPARISON OF STRUCTURAL SEISMIC RESPONSE BASED ON REAL AND SPECTRUM COMPATIBLE NEAR-SOURCE GROUND MOTION RECORDS

EARTHQUAKE RESPONSE OF HIGHWAY BRIDGES SUBJECTED TO LONG DURATION SEISMIC MOTIONS. Kataoka Shojiro 1

Influence of Peak Factors on Random Vibration Theory Based Site Response Analysis

Aeronautical Science - Professional Pilot - BS

Module 7 : Design of Machine Foundations. Lecture 31 : Basics of soil dynamics [ Section 31.1: Introduction ]

ISTANBUL EARTHQUAKE RAPID RESPONSE AND THE EARLY WARNING SYSTEM. M. Erdik Department of Earthquake Engineering aziçi University,, Istanbul

(i) Sine sweep (ii) Sine beat (iii) Time history (iv) Continuous sine

IOMAC'13 5 th International Operational Modal Analysis Conference

Quantitative Identification of Near-Fault Ground Motion using Baker s Method; an Application for March 2011 Japan M9.0 Earthquake

A Study on Effect of Sizing Bolt Hole in Single-Lap Connection Using FEA

Engineering Research into Traditional Timber Joints

Beat phenomenon in combined structure-liquid damper systems

Modal analysis: a comparison between Finite Element Analysis (FEA) and practical Laser Doppler Vibrometer (LDV) testing.

Waves Transferring Energy

CHARACTERISTICS OF LUMBER-TO-LUMBER FRAMING CONNECTIONS IN LIGHT-FRAME WOOD STRUCTURES

A Capacity Spectrum Method based Tool developed to properly include the uncertainties in the seismic risk assessment, under a logic tree scheme.

Spatial coherency of earthquake-induced ground accelerations recorded by 100-Station of Istanbul Rapid Response Network

Mechanical behavior of fiberglass reinforced timber joints

Experimental Study on the Seismic Behavior of Retrofitted Concrete Infill

Transcription:

EFFECT OF VARIOUS HYSTERETIC MODELS ON SEISMIC FRAGILITIES OF PRECAST INDUSTRIAL BUILDINGS Mehmet PALANCİ 1, Ali KALKAN 2, Yasin YILMAZ 3, Şevket Murat ŞENEL 4 ABSTRACT One story precast buildings constitutes the majority of industrial building stock of Turkey. Therefore this study interested in the seismic performance of existing precast industrial buildings. For this purpose, Denizli Organized industrial zone, which is among the important industrial regions of western Turkey, was selected. Structural properties of more than a hundred precast buildings were determined by means of project and site investigations and capacity curves of buildings were obtained by using non-linear analysis method. Seismic performance assessment of precast buildings revealed that lateral strength and ductility capacities and vibration periods of buildings range between 10%-30%, 1.3-3.5 and 1-2.8 seconds respectively. In order to assess the seismic performance of buildings, fragility curves were used and lateral drift demands, which control the fragilities of precast buildings, were calculated by using nonlinear time history analyses. More than 300 records, which classified according to their peak ground velocities (to represent low, moderate and severe earthquakes), were selected. Fragility response of precast buildings under different behavior models were examined by using four different hysteretic models. Damage probabilities of buildings were calculated by using each of these models and compared. Comparisons were made by considering different intensity levels and various damage states which are expressed in Turkish Earthquake Code-2007. Buildings were classified into sub groups considering lateral strength and ductility capacities. By this way precast industrial buildings was represented under four different strength and ductility classes. Consequently, the effect of both structural properties of buildings (expressed in terms of lateral strength and ductility) and various hysteric models were considered. Preliminary results have shown that different hysteric models have not significant effect on seismic fragilities of precast industrial buildings. INTRODUCTION In Turkey, majority of industrialized zones are located in high seismic regions. Thus, one story precast buildings constitutes the majority of industrial building stock of Turkey. The amount of damage to these buildings took the attention and this situation led to question seismic safety of precast industrial buildings after devastating earthquakes occurred in 1998 and 1999. In order to better understand seismic behavior of these buildings, seismic performance of existing precast industrial buildings is investigated. For this purpose, Denizli Organized industrial zone (DOIZ), which is among the important industrial regions of western Turkey, was selected. Structural properties of existing precast buildings were determined by means of project and site investigations and capacity curves of buildings 1 Research Asst. Faculty of Eng. and Architecture, Arel Unv., İstanbul, Turkey, mehmetpalanci@arel.edu.tr 2 Research Asst. Dept. of Civil Eng., Pamukkale Unv., Denizli, Turkey, akalkan@pau.edu.tr 3 Graduate Student, Dept. of Civil Eng., Pamukkale Unv., Denizli, Turkey, yasinyilmz@gmail.com 4 Assoc. Prof., Dept. of Civil Eng., Pamukkale Unv., Denizli, Turkey, smsenel@pau.edu.tr 1

were obtained by using non-linear analysis method. Analysis results have shown that lateral strength and ductility capacities and vibration periods of buildings range between 10%-30%, 1.3-3.5 and 1-2.8 seconds respectively. In recent years, probabilistic methods are widely used in many engineering fields and this situation shows that these methods can also be applied for precast buildings. One of the important methods which give opportunity to assess seismic performance of buildings is the calculation of seismic fragility curves of buildings. In order to assess the seismic performance of buildings, fragility curves were used and lateral drift demands, which control the fragilities of precast buildings, were calculated by using non-linear time history (NLTH) analyses. Lateral drift demands were calculated by selecting more than 300 records according to their peak ground velocities (to represent low, moderate and severe earthquakes). Seismic behavior of precast buildings is represented by four different hysteretic models (elastoplastic (EP), elastoplastic with %5 hardening (EP5%), Modified Clough stiffness degrading model (Mod. Clough) and bilinear slip (Bil. Slip)) were used. Damage probabilities of buildings were calculated for hysteretic models and compared by considering different intensity levels and various damage states. Buildings were classified into sub groups and precast industrial buildings were represented under four different strength and ductility classes. By his way, the effect of both structural properties of buildings (expressed in terms of lateral strength and ductility) and various hysteric models on seismic fragilities of precast industrial buildings was investigated. CAPACITY CURVE AND DAMAGE LEVELS OF PRECAST BUILDINGS Structural models of each building in the building stock were created and axial load ratio of each member was determined. Properties of each member (column) were determined by site and project investigations. By combining each data, strength and ductility capacities of individual member (column) were determined by moment-curvature analyses. During the moment-curvature analysis, concrete behavior model was represented by Modified Kent-Park (Park et al., 1982) model and each member sectional damage levels Immediate Occupancy(IO), Life Safety(LS), Collapse Prevention(CP) was obtained by considering concrete and steel strain limits given in Turkish Earthquake Code-2007 (TEC-2007, 2007). Strain limits of each damage level given in TEC-2007 are shown in Table 1. During the moment curvature analyses, both concrete and steel strain based limits were checked and curvature capacity of member damages was determined which limit was satisfied first. Yield curvature and moment capacity of members was calculated by considering Priestley et al. (2007) approach. Table 1. Strain based sectional member damage definitions Member damage level Concrete Steel Immediate Occupancy (IO) ( ε ) = 0. 0035 ( ε ) = 0. 01 c IO ρ s Life Safety (LS) ( ε ) 35 0.01 cc LS = + 0. 0135 ( ε s ) LS = 0. 04 ρ sm ρ s Collapse Prevention (CP) ( ε ) 4 0.014 cc CP = + 0. 018 ( ε s ) CP = 0. 06 ρ sm One story precast industrial buildings can simply be shown in Fig.1. Majority of these buildings are constructed as hinged upper connections. For this reason, each member s behavior can be represented as cantilever column and as seen from the figure that plastic hinge regions are located at the bottom of each column. This type of behavior makes simple to calculate capacity curve of buildings. For this reason, individual response of each member is calculated and then they are combined. Construction of capacity curve of precast industrial buildings can be found in the study performed by Senel and Palanci (2013). s IO 2

M.Palanci, A.Kalkan, Y.Yılmaz, Ş.M.Şenel 3 Figure 1. Typical representation of one storey existing precast buildings In Fig.2, response of cantilever type member is shown. By using moment-area theorem, displacement capacity of individual members can be calculated by Eqs.(1-3). It should be noted that one of the key factor on displacement capacity of member is the length of plastic hinge. In this study, plastic hinge length is taken the half of column height as suggested in TEC-2007. Strength capacity of is calculated by Eq.(3). Figure 2. Response of cantilever column 2 y i Li δ y i = φ 3 (1) Lp i δ = + ( ) DS δ y φ i DS φ i y L i i p L i i 2 (2) M y v i t = i L (3) Capacity curve of buildings were determined by lateral strength capacity and displacement capacity, respectively. During the calculation of capacity curves, it was considered that all columns have same drift ratios at roof level. By using this assumption, lateral strength capacity of buildings was calculated by summing of individual strength capacity of columns. Each damage state of buildings (Slight damage, moderate damage, extensive damage and collapse) was also determined by considering minimum displacement of each member damage level. It is worth to state that similar properties of columns (column dimensions, transverse/longitudinal ratios) cause similar damage levels of each individual column. Because of this reason, individual member damage drift ratios of columns (Immediate Occupancy, Life Safety, and Collapse Prevention) are not widely distributed. Aforementioned process was carried out for each DOIZ buildings and capacity curves were determined. Vibration period of buildings which is related with stiffness of the building was calculated from elastic slope of capacity curves. In Fig.3, lateral strength ratio (V t /W) according to vibration period (Fig.3a) and distribution of ductility capacity of buildings (Fig.3b) are illustrated. High i

vibration periods, emphasize the problems of inadequate lateral stiffness of precast buildings observed in past earthquakes, is also valid for DOIZ buildings. Lateral Strength ratio (Vt/W) 35% 30% 25% 20% 15% 10% 5% (a) Period (T) 0% 1.50 2.00 2.50 3.00 60.0% 45.0% 41.8% 30.6% 30.0% 17.3% 15.0% 5.1% 5.10% 0.0% <1.5 1.5-2.0 2.0-2.5 2.5-3.0 >3.0 Figure 3. Capacity related parameters of industrial precast buildings (b) DETERMINATION OF SEISMIC DISPLACEMENT DEMANDS Seismic capacity of all buildings was determined in the earlier chapter, and lateral strength ratios (V t /W) are obtained. In order to determine seismic performance of the buildings seismic demands should be calculated. In this study, seismic demands are calculated using nonlinear-time history analyses. For this reason, 364 records were selected (292 unscaled and 72 scaled records). Records were scaled (maximum scale factor: 1.52) to represent moderate to severe earthquakes in terms of higher peak ground velocities (PGV). In literature, some studies (Akkar and Ozen 2005, Akkar and Kucukdogan 2008) pointed out the high correlations between seismic demand of single degree of freedom systems (sdof) and PGV values. Thus, PGV was considered as earthquake parameter during the calculation of fragility curves of precast buildings and PGV value of records were selected between 20 and 80 cm/s. In Table 2, number of selected records corresponding to each PGV bin is given. As it can be seen from the tables that 12 PGV intervals was generated and almost equal number of records were selected to obtain uniform PGV distribution. After selection of records, each building was analyzed using its own lateral strength ratio and vibration period by Bispec (Hachem, Bispec) program. During the analyses seismic behavior of precast buildings is represented by four different hysteretic models elastoplastic (EP), elastoplastic with %5 hardening (EP5%), Modified Clough stiffness degrading model (Mod. Clough) and bilinear slip (Bil. Slip). Table 2. Strain based sectional member damage definitions PGV bin name Lower-Upper limits (cm/s) No. of records Mean Std.dev PGV1A <25.0 29 21.69 1.21 PGV1B 25.0-30.0 31 27.31 1.50 PGV1C 30.0-35.0 34 32.05 1.48 PGV1D 35.0-40.0 30 37.35 1.9 PGV2A 40.0-45.0 30 41.77 1.28 PGV2B 45.0-50.0 30 47.15 1.54 PGV2C 50.0-55.0 30 52.16 1.47 PGV2D 55.0-60.0 30 57.18 1.32 PGV3A 60.0-65.0 30 62.07 1.14 PGV3B 65.0-70.0 30 67.52 0.97 PGV3C 70.0-75.0 30 72.55 PGV3D >75.0 30 77.31 1.09 ANALYTICAL FRAGILITY CURVES OF PRECAST BUILDINGS As a result of nonlinear dynamic analyses, 142688 maximum seismic demands are calculated for all hysteric models. Exceeding numbers and ratios of each group and each damage level was obtained by 4

M.Palanci, A.Kalkan, Y.Yılmaz, Ş.M.Şenel 5 comparing each displacement demand and damage levels. Analytical fragility curves of precast buildings were then drawn by assuming two-parameter lognormal distribution using these exceedance ratios. Lognormal distribution parameters; mean (λ) and standard deviation (σ) were estimated by least squares method. Eq.(4) can be used to express cumulative probability of interested exceeding damage level. (lnpgv - λ) Pr = Φ [ ] (4) σ In equation, Φ is represented as standard cumulative normal distribution function and as mentioned earlier PGV is ground motion parameter selected for this study. In Fig.4, probability of extensive damage fragility curves is drawn for each hysteric model and all buildings. Mean fragility curve of each hysteric model is also illustrated with thick lines. Fig.4 clearly indicates the variability of fragility curves of buildings and hysteric models. In order to investigate the effect of hysteric models and structural parameters, mean fragility curve of each strength and ductility classes is obtained and compared. P(%) P(%) (a) (b) (c) (d) Figure 4. Probability of extensive damage (a: EP, b: EP (%5), c: Mod. Clough, d: Bil. Slip) EFFECT OF STRUCTURAL PARAMETERS AND HYSTERIC MODELS ON FRAGILITY CURVES Senel et al. (2013) is investigated the effect of stiffness which is related with vibration period, lateral strength ratio and ductility parameters on seismic performance of precast buildings. According to study, lateral strength ratio and ductility capacity parameters have highest priority on seismic performance of precast buildings especially at higher damage levels. Accordingly, structural parameters (lateral strength ratio and ductility capacity) are willingly selected to investigate the effect of hysteric models on seismic performance (fragility) of precast buildings. Selected structural parameters are clustered into four groups and given as follows:

Low strength low ductility cap. : Vt/W < 18% & µ< 2.5 High strength low ductility cap. : Vt/W 18% & µ< 2.5 Low strength high ductility cap. : Vt/W < 18% & µ 2.5 High strength high ductility cap. : Vt/W 18% & µ 2.5 After separation of groups the effectiveness of damage states on hysteric models was first checked. Observations indicated similar probability of slight and moderate damage states for all hysteric models in each group. Fig.5 presents seismic fragilities of slight and moderate damage states of distinct low strength& low ductility and high strength& high ductility buildings groups. In the figures it is hard to distinguish seismic fragilities of hysteric models. Similar observations were made for rest of groups. For this reason, the effect of structural parameters and hysteric models are investigated for extensive damage and collapse states in the rest of paper. Bil. Slip Vt/W 0.18 μ 2.5 Slight Mod. Clough Vt/W 0.18 μ 2.5 Slight EP Vt/W 0.18 μ 2.5 Slight EP (%5) Vt/W 0.18 μ 2.5 Slight Bil. Slip Vt/W 0.18 μ 2.5 Moderate Mod. Clough Vt/W 0.18 μ 2.5 Moderate EP Vt/W 0.18 μ 2.5 Moderate EP (%5) Vt/W 0.18 μ 2.5 Moderate Bil. Slip Vt/W<0.18 μ<2.5 Slight Mod. Clough Vt/W<0.18 μ<2.5 Slight EP Vt/W<0.18 μ<2.5 Slight EP (%5) Vt/W<0.18 μ<2.5 Slight Bil. Slip Vt/W<0.18 μ<2.5 Moderate Mod. Clough Vt/W<0.18 μ<2.5 Moderate EP Vt/W<0.18 μ<2.5 Moderate EP (%5) Vt/W<0.18 μ<2.5 Moderate Figure 5. Comparison of different hysteric model fragilities in terms of slight and moderate damages After first observations, the effectiveness of parameters is followed in two cases. In the first case, the effects of structural parameters are evaluated for each hysteric model. Fig.6 presents the comparison of seismic fragilities of two damage states for all building groups and hysteric models. As expected, high probabilities are observed in low strength& low ductility groups and low probabilities are observed in high strength& high ductility groups. If the ductility capacity or lateral strength ratio is kept constant, it will be seen that the probability of damages decreases with an increasing ductility capacity and/or lateral strength ratio. 6

M.Palanci, A.Kalkan, Y.Yılmaz, Ş.M.Şenel 7 EP Vt/W<0.18 μ<2.5 Extensive EP Vt/W<0.18 μ<2.5 Collapse EP Vt/W<0.18 μ 2.5 Extensive EP Vt/W 0.18 μ<2.5 Extensive EP Vt/W<0.18 μ 2.5 Collapse EP Vt/W 0.18 μ<2.5 Collapse EP Vt/W 0.18 μ 2.5 Extensive EP Vt/W 0.18 μ 2.5 Collapse EP (%5) Vt/W<0.18 μ<2.5 Extensive EP (%5) Vt/W<0.18 μ<2.5 Collapse EP (%5) Vt/W<0.18 μ 2.5 Extensive EP (%5) Vt/W 0.18 μ<2.5 Extensive EP (%5) Vt/W<0.18 μ 2.5 Collapse EP (%5) Vt/W 0.18 μ<2.5 Collapse EP (%5) Vt/W 0.18 μ 2.5 Extensive EP (%5) Vt/W 0.18 μ 2.5 Collapse Mod. Clough Vt/W<0.18 μ<2.5 Extensive Mod. Clough Vt/W<0.18 μ 2.5 Extensive Mod. Clough Vt/W 0.18 μ<2.5 Extensive Mod. Clough Vt/W 0.18 μ 2.5 Extensive Mod. Clough Vt/W<0.18 μ<2.5 Collapse Mod. Clough Vt/W<0.18 μ 2.5 Collapse Mod. Clough Vt/W 0.18 μ<2.5 Collapse Mod. Clough Vt/W 0.18 μ 2.5 Collapse Bil. Slip Vt/W<0.18 μ<2.5 Extensive Bil. Slip Vt/W<0.18 μ<2.5 Collapse Bil. Slip Vt/W<0.18 μ 2.5 Extensive Bil. Slip Vt/W 0.18 μ<2.5 Extensive Bil. Slip Vt/W<0.18 μ 2.5 Collapse Bil. Slip Vt/W 0.18 μ<2.5 Collapse Bil. Slip Vt/W 0.18 μ 2.5 Extensive Bil. Slip Vt/W 0.18 μ 2.5 Collapse Figure 6. Effect of structural parameters on seismic fragilities of precast industrial buildings In second case, each building group is evaluated separately and effect of hysteric models on seismic fragilities of precast buildings is investigated. It can be seen from the Fig.7 that in all building groups and in each damage case Bil. Slip hysteric model results give the highest probabilities. Furthermore, EP %5 hysteric model results give the lowest probabilities in each group. Except the minor changes, similar probabilities are observed in EP and Modified Clough hysteric models.

Bil. Slip Vt/W<0.18 μ<2.5 Extensive Bil. Slip Vt/W<0.18 μ<2.5 Collapse Mod. Clough Vt/W<0.18 μ<2.5 Extensive EP (%5) Vt/W<0.18 μ<2.5 Extensive EP Vt/W<0.18 μ<2.5 Extensive Mod. Clough Vt/W<0.18 μ<2.5 Collapse EP (%5) Vt/W<0.18 μ<2.5 Collapse EP Vt/W<0.18 μ<2.5 Collapse Bil. Slip Vt/W<0.18 μ 2.5 Extensive Bil. Slip Vt/W<0.18 μ 2.5 Collapse Mod. Clough Vt/W<0.18 μ 2.5 Extensive EP (%5) Vt/W<0.18 μ 2.5 Extensive Mod. Clough Vt/W<0.18 μ 2.5 Collapse EP (%5) Vt/W<0.18 μ 2.5 Collapse EP Vt/W<0.18 μ 2.5 Extensive EP Vt/W<0.18 μ 2.5 Collapse Bil. Slip Vt/W 0.18 μ<2.5 Extensive Bil. Slip Vt/W 0.18 μ<2.5 Collapse Mod. Clough Vt/W 0.18 μ<2.5 Extensive EP (%5) Vt/W 0.18 μ<2.5 Extensive Mod. Clough Vt/W 0.18 μ<2.5 Collapse EP (%5) Vt/W 0.18 μ<2.5 Collapse EP Vt/W 0.18 μ<2.5 Extensive EP Vt/W 0.18 μ<2.5 Collapse Bil. Slip Vt/W 0.18 μ 2.5 Extensive Bil. Slip Vt/W 0.18 μ 2.5 Collapse Mod. Clough Vt/W 0.18 μ 2.5 Extensive EP (%5) Vt/W 0.18 μ 2.5 Extensive Mod. Clough Vt/W 0.18 μ 2.5 Collapse EP (%5) Vt/W 0.18 μ 2.5 Collapse EP Vt/W 0.18 μ 2.5 Extensive EP Vt/W 0.18 μ 2.5 Collapse Figure 7. Effect of hysteric models on seismic fragilities of precast industrial buildings Even though behavior of EP and Modified Clough hysteric models are quite different, fragilities of these models are similar. In the study, Modified Clough model was used to reflect strength and stiffness degrading characteristics but as mentioned in earlier, precast industrial buildings have lower lateral stiffness capacity. So, the effect of stiffness degrading behavior cannot clearly be seen on 8

M.Palanci, A.Kalkan, Y.Yılmaz, Ş.M.Şenel 9 fragility curve of precast industrial buildings. In conclusion, results have shown that different hysteric models have not significant effect on seismic fragilities of precast industrial buildings. ACKNOWLEDGEMENT The authors acknowledge support provided by Scientific and Technical Research Council of Turkey (TUBITAK) under Project No: 110M255. The authors wish to express their gratitude also to directorate of Denizli Organized Industrial Zone for providing design projects of precast buildings. CONCLUSIONS Structural properties of numerous precast industrial buildings were determined in DOIZ by using design projects of precast buildings and then buildings were inspected by site investigations. Nonlinear analysis models of DOIZ buildings were prepared and capacity curve of buildings were constructed. Using obtained capacity curves, buildings were divided into 4 groups according to their lateral strength ratio and ductility capacity. Previous studies and experiences have shown that selected groups can be used to represent inventory buildings and existing building stock of Turkey. Thus, groups can be used to evaluate the relation of damage states and capacity related parameters of precast industrial buildings. For this purpose, probabilistic approach was used and fragility curve of precast buildings for various earthquake intensities was calculated. While fragility curves of precast industrial buildings were prepared, different hysteric models were also used for corresponding groups. By this way the effect of various hysteric models on seismic fragilities of precast buildings were investigated. Obtained fragility curves were evaluated and following conclusions are made: Ductility parameter becomes more effective on seismic fragilities of precast buildings especially at higher damage levels. Lateral strength ratio is found as the most effective parameter on seismic fragilities of precast buildings. Observations has clearly that lateral strength ratios may be used to represent slight and moderate damage levels, but this situation is not valid for extensive and collapse damage states. So, both ductility and lateral strength ratio parameters should be used together to represent higher damage ratios. Extensive and collapse fragility curves are relatively close together in buildings which have lower ductility (μ<2.5). Hysteric models on slight and moderate damage fragilities have lower effects (See Fig.4).. This situation is valid for all building groups Higher probabilities are observed in low strength& low ductility groups and low probabilities are observed in high strength& high ductility groups as expected and this situation is valid for all hysteric models. It is found that bilinear slip hysteric model gives the highest probabilities for all building groups among the other hysteric models. Elastoplastic with 5% hardening model gives the lowest probabilities. It is observed that modified Clough and elastoplastic with no hardening hysteric models have similar probabilities. When all seismic fragilities are evaluated, it is seen that different hysteric models have not significant effect on seismic fragilities of precast industrial buildings. REFERENCES Akkar S and Kucukdogan B (2008) Direct use of PGV for estimating peak nonlinear oscillator displacements, Earthquake Engineering and Structural Dynamics, 37(12):1411-1433

Akkar S and Ozen O (2005) Effect of peak ground velocity on deformation demands for sdof systems, Earthquake Engineering and Structural Dynamics, 34:1551-1571 Hachem M.M., BiSpec, http://eqsols.com/default.aspx Park R, Priestley MJN and Gill WD (1982) Ductility of Square-Confined Concrete Columns, Journal of Structural Division-ASCE, 108(ST4):929 950 Priestley MJN, Calvi GM and Kowalsky MJ (2007) Displacement Based Seismic Design of Structures, IUSS Press, Pavia Senel SM and Palanci M (2013) Structural Aspects and Seismic Performance of 1-Story Precast Buildings in Turkey, J. Perform. Constr. Facil., 27(4):437-449 Senel SM, Palanci M, Yılmaz Y, Kalkan A (2013) Yapısal parametrelerin tek katlı mafsallı prefabrik binalarin hasar görebilirlik eğrileri üzerindeki etkisi, 2. Türkiye Deprem Mühendisliği ve Sismoloji Konferansı, Hatay, Turkey, 25-27 September TEC-2007 (2007), Regulations on buildings to be built in seismic regions, Ministry of Public Works and Settlement, Ankara 10