Wind Direction Transmitter - compact - with serial output x0.x00

Similar documents
Wind Direction Transmitter - compact

Wind Direction Transmitter - compact - with Poti Output xx.712

Wind Direction Transmitter - compact - GMR, analogue output xxx

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

Wind Transmitter First Class

Wind Direction Transmitter - compact - TMR, analogue output x.xxx xxx

Wind Transmitter compact xx

Wind Direction Transmitter - compact - with Poti Output xx.712

Wind Transmitter compact xx

Wind Transmitter First Class / 141 / / 141 / 161

Wind Transmitter - compact

Wind Transmitter First Class Advanced Classified according to IEC ( )

Wind Direction Transmitter First Class analogue output x0.1xx

Wind Transmitter - with analogue output xxx

Wind Transmitter - with frequency output xx.xxx

Combined Wind Transmitter - with analogue output xxx

Instruction for Use /05/09. Wind Transmitter - compact x0.xxx x0.xx x0.xx0

Wind Direction Transmitter First Class Low Power Device with digital output, 8 Bit serial-synchronous x0.000

Wind Direction Transmitter First Class analogue output x0.1xx

Brightness Transmitter

Digital Anemometer

WIND VANE THIES COMPACT

WIND VANE THIES COMPACT TMR

Sensor PAR xxx

WIND VANE THIES FIRST CLASS 2014 TMR

Precipition Sensor with analogue Intensity Output ,

Wind Direction Transmitter First Class - Device with digital output, RS Wind velocity signal acquisition x0.400

Brightness Transmitter - direction-independent xxx

Hygro-ThermoTransmitter-compact xxx

Precipitation Transmitter xxx / xxx

Precipitation Transmitter / 008 / 009 / 010 / 011 / 107 / / 009

Precipitation Monitor ,

THE WORLD OF WEATHER DATA Measurement and Documentation: Thies range of service for meteorology, environmental protection and industry

ABSOLUTE ROTARY ENCODER SSI

ABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL

Baro Transmitter PTB x1.073

NEW. Automation Technology 768 series

ABSOLUTE ROTARY ENCODER SSI

ABSOLUTE ROTARY ENCODER SSI

XXXX e. X d.. X X X a

WIND T H E W O R L D O F W E A T H E R D A T A

OPERATING INSTRUCTIONS

Product Information. RCN 2000 RCN 5000 RCN 8000 Absolute Angle Encoders for Safety-Related Applications

XXXX e. X d.. X X X a

Technical data. General specifications V DC No-load supply current I 0. typ. 50 ma Power consumption P 0

LENORD. +BAUER... automates motion. GEL 2351 with current or voltage interface. Technical information Version General. Features.

FINAL. Hygro-ThermoTransmitter-compact xxx xxx MEETINSTRUMENTATIE. Instruction for use /06/ x4.0xx/1xx/4xx/8xx...

Precipitation transmitter

SW 16mm. SW 15mm. SW 19mm

6-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

Technical data. General specifications. Linearity error ± 0.1 Electrical specifications Operating voltage U B

n Measurable displacements between n Linearity: max. ± 0.05 % n Housing diameter 12.9 mm n Service life: 10 8 movements

Multiturn absolute encoder

Product Information. ECN 413 ECN 425 ERN 421 ERN 487 Rotary Encoders for Drive Control in Elevators

WIND MONITOR ANEMO / WIND VANE YOUNG ALPINE

ABSOLUTE ROTARY ENCODER SSI PROGRAMMABLE

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 700 a at 40 C Mission Time (T M ) L 10

Product Information. ERN 1085 Incremental Rotary Encoder with Z1 Track

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT

ABSOLUTE ROTARY ENCODER DEVICE NET

Rotary Encoder System Compact Model Range

Ultrasonic Anemometer

LENORD. +BAUER... automates motion. Magnetic incremental encoder GEL 293 for heavy duty applications. Technical Information Version 04.

Operating Instructions. Combination sensor

Magnetic absolute rotary encoder GEL 235 Singleturn, Multiturn up to 28 bits (SSI)

Material: Weight: Shaft Loads:

Technical data. General specifications V DC Power consumption P 0. 1 W Time delay before availability t v

Oil & Gas / Heavy Industry Type 2REX-A-NA-SSI

Multiturn absolute encoder

Combi sensor C B1. A: Wind wheel. west, east, south C: Dawn sensor D: Rain sensor. Ref.-No. with DCF77 receiver WS 10 KSDCF (No KNX device)

Table and Furniture Base Fittings Plinth Adjusting Fittings

INSTALLATION INSTRUCTION RRU DOUBLE LIGHT POLE MOUNT

ABSOLUTE ROTARY ENCODER CAN-BUS

INLINE flowmeter for continuous flow measurement

Measuring and Controlling Unit Multronic OC

LENORD. +BAUER... automates motion. GEL 295x Customer-specific precision encoder. Technical Information Version General information.

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 700 a at 40 C Mission Time (T M ) L 10

Multiturn absolute encoder

Phone: Fax: Web: -

LENORD GEL BAUER

INLINE flowmeter for continuous flow measurement

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

Absolute Rotary Encoder EXAG Explosion Proof. Canopen

INLINE flowmeter for continuous flow measurement

LENORD. +BAUER... automates motion. GEL 2037 with heavy duty flange or tooth wheel adapter. Technical information Version General.

12-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

12-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

LENORD. +BAUER... automates motion. Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter

2-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT Enhanced Sidelobe Suppression

Encoder - Absolut 2RMHF-SSI

TECHNICAL DATASHEET Absolute Encoder AC 58 - BiSS / SSI

IBV 100/EXE 100 Interpolation and Digitizing Electronics

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

Technical data. Functional safety related parameters MTTF d Mission Time (T M ) max. 140 ma Power consumption P 0. Voltage drop

ABSOLUTE ROTARY ENCODER DEVICE NET

Data Sheet AS25/AS50. Absolute / Incremental Singleturn Encoder 18 Bit

Clamping devices 521

Measurement and Sensor Systems with conception

Absolute Rotary Encoder EXAG Explosion Proof. Device Net

Rotary Measurement Technology Incremental Encoders

Transcription:

THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021450/11/05 Wind Direction Transmitter - compact - with serial output - 4.3129.x0.x00 ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany Box 3536 + 3541 37025 Göttingen Phone ++551 79001-0 Fax ++551 79001-65 www.thiesclima.com info@thiesclima.com

Contents 1 Models available... 2 2 Application... 3 3 Construction and Mode of Operation... 3 4 Recommendation Side Selection/Standard Installation... 4 5 Installation... 4 5.1 Mechanical Mounting... 4 5.2 Electrical Mounting... 4 6 Plug Mounting... 5 7 Maintenance... 5 8 Connecting Diagram... 6 9 Technical Data... 7 10 Dimensional Drawing... 8 11 Accessories... 9 Figures Figure 1: Connecting diagram for models with cable... 6 Figure 3 : Interface specification... 7 Figure 4: Dimensional drawing with cable... 8 Figure 5: Dimensional drawing with plug... 8 1 Models available Order-No. Meas. range Elect. output Heating capacity Connection 4.3129.00.000 0... 360 5 bit serial 20 W 12 m cable LiYCY 6 x 0,25 mm² 4.3129.00.150 0... 360 5 bit serial 20 W 15 m cable LiYCY 6 x 0,25 mm² 4.3129.00.300 0... 360 5 bit serial 20 W 3,5 m cable LiYCY 6 x 0,25 mm² 4.3129.00.500 0... 360 5 bit serial 20 W 5,5 m cable LiYCY 6 x 0,25 mm² 4.3129.00.700 0... 360 5 bit serial 20 W 7 pole plug 4.3129.10.110 0... 360 5 bit serial w/o heating 10 m cable LiYCY 6 x 0,25 mm² 2-10 021450/11/05

2 Application The wind direction transmitter is designed for the acquisition of the horizontal wind direction. The measuring values are output as electrical digital signals, for example for processing or storing. An electronically-regulated heating system has been installed optionally for wintertime use, in order to prevent a blocking of the gap between the external rotation parts by ice aggregation. Power for the heating system could be provided for instance by our Power Supply Unit, Order No. 9.3388.00.000. 3 Construction and Mode of Operation The outer parts of the instrument are made of corrosion-resistant material ( aluminum, stainless steel, plastic ). The aluminum parts are additionally protected by means of an anodic coat. Labyrinth sealing protects sensitive parts inside the instrument against humidity. The wind direction is detected by means of a low-inertia wind vane, the ball bearing axis of which is connected to a code disc. This code disc contains a 5 bit Gray-code which is scanned optoelectronically, and is available at the output in serial form. The code disc resolves the wind direction into 32 sectors (11,25 / Sector). The serial output signal is proportional to the 32 sectors. The sectors start at wind direction N (North) with sector 0, and end with sector n (see drawing). Sektor 31 [North = 0 = 360 ] N Sektor 0 W S S E 32 Sektors 3-10 021450/11/05

4 Recommendation Side Selection/Standard Installation In general wind measurement instruments should be able to detect the wind conditions of a large area. In order to obtain comparable values when determining the surface wind, measurements should be taken at a height of 10 meters over an even unobstructed area. An unobstructed area means that the distance between the wind transmitter and an obstacle should be at least 10 times the height of the obstacle ( s. VDI 3786 ). If it is not possible to fulfil this condition, then the wind transmitter should be set up a height where local obstacles do not influence the measured values to any significant extent (approx. 6-10 m above the obstacle). The wind transmitter should be set up in the centre of flat roofs and not on the roof side in order to avoid bias in the direction (privileged directions). 5 Installation Attention: Storing, mounting and operation under weather conditions is permissible only in vertical position, as otherwise water can get into the instrument. Remark: When using fastening adapters (angle, traverses, hangers etc.) please take a possible effect by turbulences into consideration. 5.1 Mechanical Mounting The mounting of the transmitter could be done for example at a traverse with a boring of PG 21 or on hangers with a boring of 29 mm. (for ex. traverse compact, order-no. 4.3171.30.000). The connection cable or connecting plug is passed through the boring, and the wind direction transmitter is fixed with hexagonal nut (SW36) after the north alignment. North Alignment Rotate the case markings (north marking) on the shaft and on the protective cap until they are aligned. Then select an obvious point in a northerly direction in the surroundings ( a tree, a building etc.) with the aid of a compass. Take a bearing on this point over the wind vane and the counter weight of the wind direction transmitter, and when these coincide screw the wind transmitter into place. (the north marking must indicate to the geographic north). 5.2 Electrical Mounting For electrical connection please refer to the connecting diagram. 4-10 021450/11/05

6 Plug Mounting 1. Stringing parts 2. Stripping and widening of shield 3. Assembling shield clamping ring 4. Soldering wire, tripping distance bush 5. Cutting off projecting shield 6. Assembling remaining parts according to plan 7 Maintenance After proper mounting the instrument works maintenance free. Heavy pollution can clog up the slit between the rotating and the stationary parts of the wind transmitter. This slit must be kept clean. 5-10 021450/11/05

8 Connecting Diagrams Order-No. 4.3129.00.000 4.3129.00.150 4.3129.00.300 4.3129.00.500 Heating 20 W PG 9 / Cable Cable colour code 4.3129.10.110* 1 Power supply 5...14 V DC 2 3 Ground Data Wind direction 4 5 6 Clock Hz Hz Heating 24 V AC / DC 20 W Shield Ground 1 white 2 brown 3 green 4 yellow 5 grey 6 pink * the instrument w/o heating is dispensed with 5 + 6 Figure 1: Connecting diagram for models with cable Order-No. 4.3129.00.700 Heating 20 W View on the soldered joint of the counter plug 7 pol Plug 1 2 3 4 5 6 7 3 4 2 7 5 1 6 Power supply 5..14 V DC Ground Data Clock Wind direction Hz Hz Heating 24 V AC / DC 20 W Figure 2: Connecting diagram for models with plug 6-10 021450/11/05

9 Technical Data Characteristic Description / value Measuring range 0 360 Resolution 11,25 Accuracy ± 5 Measuring principle Opto-electronic Output 5-Bit Code serial Electr. output Output signal Load (max.) U L = 0 / U H U B (unloaded) 10 ma Serial interface see interface specification Operating voltage 5... 14 V DC Current consumption Standby-operation Active operation at U B = 5 V < 15 µa < 500 µa Operating voltage heating 24 V DC/AC, max. 20 W Ambient temperature - 40 C... + 70 C Survival speed maximally 80 m/s, 30 minutes Connection See models available Dimensions See dimensional drawing Mounting For ex. onto a mast tube with receptacle thread PG 21 or boring 29 mm Protection IP 55 Weight approx. 0,6-1,1 kg ts tc Clock Data tw LSB 8 bit MSB LSB 8 bit invers MSB Parameter Symbol Min Max Unit Start pulse (1. Clock pulse) ts 2 10 ms Conversion time until data valid tw - 1,5 ms Clock puls lenght tc 0,2 10 ms Measuring value scan rate f - 30 Hz Figure 2 : Interface specification 7-10 021450/11/05

10 Dimensional Drawing Counter weight Wind vane 120 North - marking 166 220 Ø50 165 PG 21 SW 36 PG 9 Figure 3: Dimensional drawing with cable Counter weight Wind vane 120 North - marking 166 210 Ø50 165 PG 21 SW 36 Plug Figure 4: Dimensional drawing with plug 8-10 021450/11/05

11 Accessories The following accessories are available for the wind direction transmitter: Traverse For mounting the wind speed transmitter and wind direction transmitter compact jointly onto a mast. 4.3171.30.000 4.3171.31.000 Clamping range: Ø 48... 102 mm Clamping range: Ø 116... 200 mm Sensor distance: 0,8 m Material: Aluminum Traverse, short For mounting the wind direction transmitter compact onto a mast. 4.3171.40.000 4.3171.41.000 Clamping range: Ø 48... 102 mm Clamping range: Ø 116... 200 mm Length: 0,4 m Material: Aluminum Lightning rod For mounting the a.m. traverses 506351 Length: 0,56 m Material: stainless steel Please contact us for other accessories such as cables, power supply units, masts, as well as for additional mast- or system-constructions. 9-10 021450/11/05

ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany P.O. Box 3536 + 3541 37025 Göttingen Phone ++551 79001-0 Fax ++551 79001-65 www.thiesclima.com info@thiesclima.com - Alterations reserved - 10-10 021450/11/05