SPECIFICATION FOR 11 KV CLASS, 24/15.7, 30/19.7 & 45/29.5 AMPS SPECIAL DESIGN TRANSFORMERS.

Similar documents
SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

Prolific Systems & Technologies Pvt. Ltd. CORE DETAILS. CENTRE Figure - II L-2 X Y Wt-2

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

POTENTIAL TRANSFORMER

TECHNICAL SPECIFICATION OF 11 KV THREE PHASE FOUR WIRE, THREE CTs COMBINED METERING CTPT SET OF ACCURACY CLASS 0.5s

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

TECHNICAL SPECIFICATION OF 11 KV AND 22 KV THREE PHASE FOUR WIRE, THREE

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

SOUTHERN ELECTRICITY SUPPLY COMPANY OF ODISHA LIMITED (SOUTHCO UTILITY)

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS CT & PT GROUP C

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

EARTHING TRANSFORMER

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS

Reference Number PPS 05 - (RIC Standard: EP SP)

No. COA/BHL/2018/293 Dated: REQUEST FOR QUOTATIONS

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

Maharashtra State Electricity Distribution Company Limited

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

General Electricity Company of Libya

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

APDRP SCHEME, WESCO. Technical Specification for Distribution Transformers ( 11/0.4KV ) PART 1: GENERAL

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

TECHNICAL SPECIFICATION

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

CAPACITOR VOLTAGE TRANSFORMER

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

Particulate Control O&M Training. APC/PCUG Conference July 12-16, 2009 The Woodlands, TX

Technical Specification For 33 KV, Single Phase, Dead Tank Type Out Door Current Transformer Of Different Ratio

User s Manual For CT Model IMB

TECHNICAL SPECIFICATION FOR SELF PROTECTED SINGLE PHASE DISTRIBUTION TRANSFORMERS ( SPECIFICATION NO: DIST/01-N/2004 )

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

HOW TO SAFE GUARD THE TRANSFORMER..???

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

DISTRIBUTION TRANSFORMER kv

Company Directive ENGINEERING SPECIFICATION EE SPEC: 5/5. Relating to 11kV Distribution Transformers

TECHNICAL SPECIFICATION FOR 22 KV CURRENT TRANSFORMERS

TECHNICAL SPECIFICATION FOR G. I. WIRE (4MM)

This Manual Part recommends design criteria for resistors suitable for railway signaling circuits other than electronic.

2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type

DISTRIBUTION TRANSFORMER 11 / kv

Maharashtra State Electricity Distribution Company Limited MATERIAL SPECIFICATIONS CELL

(TECHNICAL SPECIFICATIONS & GTP FORMATS) 11KV METERING UNITS

MESP TECHNICAL SPECIFICATION FOR A 1500V DC RECTIFIER TRANSFORMER

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

Technical Specification. for 1.1 KV Copper Control Cable

BUREAU OF INDIAN STANDARDS. Draft Indian Standard TWO COMPONENTS HIGH BUILD EPOXY MICACIOUS IRON OXIDE (MIO) PIGMENTED INTERMEDIATE COAT SPECIFICATION

TECHNICAL SPECIFICATION OF 630 KVA, 11/ KV DRY TYPE OUTDOOR TRANSFORMERS.

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

SECTION METAL FABRICATIONS

TIGHTENING TORQUE ON WOODEN CORE CLAMP (Nm) (STEEL FASTENER) 1 M M M M M

Maharashtra State Electricity Distribution Co. Ltd.

PUBLIC POWER CORPORATION ENGINEERING & CONSTRUCTION OF TRANSMISSION PROJECTS DEPARTMENT

Basic Principles and Operation of Transformer

SECTION-IV TECHNICAL SPECIFICATIONS FOR TRANSFORMER REPAIRING MATERIALS

PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS

PPC TECHNICAL SPECIFICATION D/ NCMD / THREE-PHASE DISTRIBUTION TRANSFORMERS

Electrical Design Process

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

SECTION-IV TECHNICAL SPECIFICATIONS FOR TRANSFORMER REPAIRING MATERIALS

BANGALORE ELECTRICITY SUPPLY COMPANY LIMITED

Maharashtra State Electricity Distribution Company Limited

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

PS REV NO: 01 PAGE : 2 OF 22

Introduction. Centrado leading-edge transformer. Introduction

LIGHTNING ARRESTOR. September 2017 WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

MIL- B Rev NAVSEA 0900-LP

Transformers handling and transport

MESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2

VOLUME - 4 (GENERAL TECHNICAL SPECIFICATIONS)

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

SCHEDULE A SR. NO. 1 No.

Single & Three Phase Transformers SAMPLE. Learner Workbook. Version 1. Training and Education Support Industry Skills Unit Meadowbank

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

Howard Smart Transformer Specification Guide

TECHNICAL SPECIFICATION FOR OUTDOOR 160 KVA AMORPHOUS / CRGO CORE CSP ALUMINIUM CONDUCTOR DISTRIBUTION TRANSFORMERS WITH BEE 5 STAR RATING

Miniature Steam Pty Ltd (Incorporating Live Steam Supplies)

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

Anodising is the process where Aluminum Oxide film is created on the section to avoid corrosion. (The tanks used are nos. 16, 17, 19 and 20)

Liquid-Filled Transformers

WEST BENGAL STATE ELECTRICITY DISTRIBUTION COMPANY LTD.

MIL- B B. MIL- B Rev NAVSEA 0900-LP II: ATTRIBUTES: YES NO N/A

SYRIAN ARAB REPUBLIC MINISTRY OF ELECTRICITY PUBLIC ESTABLISHMENT FOR DISTRIBUTION THE ELECTRICITY (PEDE) SPECIFICATIONS FOR

SPECIFICATION FOR SAFETY POLE SIGNS & ACCESSORIES

METAL FABRICATION SECTION 8: METAL FABRICATION SCOPE MATERIAL.

Transcription:

SPECIFICATION FOR 11 KV CLASS, 24/15.7, 30/19.7 & 45/29.5 AMPS SPECIAL DESIGN TRANSFORMERS. 1. SCOPE: This specification covers design, manufacture, testing and supply of 6.64/10.12 KV 24/15.7, 30/19.7 & 45/29.5 Amps special design transformers. 2. The supplier shall have to produce an attested copy of the License of manufacturing the special Design Transformer from the patent holder of the concept (GUVNL). 3.1 AMBIENT CONDITIONS : i. Maximum ambient temperature in shade : 45 C ii. Max. weighted average ambient temp. : 40 C iii. Maximum temperature under sun : 55 C iv. Minimum ambient temperature : 0 C v. Maximum relative humidity : 95% vi. Average thunder storm days / annum : 15 vii. Average rainy days per annum : 90 viii. Average annual rail fall : 750/800Ml ix. Number of months of tropical monsoon : 3 x. Maximum wind pressure : 150 Kg/M 2 3.2 INSTALLTION : Outdoor either pole mounted, hung or platform mounted. 3.3 SYSTEM : 11KV CLASS Single Phase, 50 Hz + 3% Voltage Class : 11000 volts Voltage variation : + 5% BIL : 75 KV peak 4. APPLICABLE STANDARDS : Unless otherwise specifically stated in this specification the transformers shall conform to the following standards considering this as single phase transformers. IS 2026 Part I, II, III & IV IS 3639 1966 IS-6600/1972 IS 3347 IS 2099-86 IS 5621-80 IS 7421-88

5. MATERIAL : 5.1 INSULATION : The insulation of wire / strip, inter-layers between two winding and to earth shall be of class A. Wherever wood is used it shall be well-seasoned and dry. Wire/strips shall be DPC. So far as paper, press Boards are used they shall be of reputed makes (Appendix A) and conform to ISI. 5.2 WINDING : Transformers shall have Copper windings except below 30 Amps 11 KV Class which shall have Aluminum winding. 6. STANDARD RATINGS : 6.1 The Standard continuous ratings are 24,30 & 45 Amps. 6.2 No load voltage ratio : 6.64/10.12 KV for 11 KV class. 7. FITTINGS : The following standard fittings shall be provided : i) Phase R should be identified as it is ground phase with symbol 1 ii) iii) iv) The Earthing terminals with symbol 1 with tinned copper lugs. Lifting lugs of adequate size for lifting the transformer and lifting the active parts assembly separately. The lifting lugs shall be made from minimum 8mm thick MS Plate with adequate base. Rating and terminal marking plates. The figures shall be etched and not anodized. The plates shall be riveted on oil level gauge side. v) Thermometer pocket for all ratings. The tube of thermometer pocket shall vi) vii) remain immersed in oil to the extent of at least 100mm. Oil conservator tank (a) filling hole and plug on the top. (b) Oil level gauge and (c) Breather of having aluminum die cast body and silica gel 0.5 Kg. Breather pipe shall be provided. Position of oil level gauge shall be towards rating and terminal marking plate. A drain cum sampling valve of 32 mm dia (1.1/4 Bsp) with plug on top cover of the transformers for drawing sample etc.

8. TECHNICAL PARTICULARS : 8.1 LOSSES AND IMPEDANCE : The no-load loss, load loss and impedance value for transformers shall be as under. The tolerance for percentage impedance shall be + 10% No-load current No load losses at rated voltage & frequency Load losses at 75 C Rating Wind- Impedance ing at 75 C Y-B Short Y-B Short A. a) 24 A/11KV Al. 1% 170 W 1250 W 2.5 % 7.64 % b) 24 A/11KV Cop. 1% 160 W 1140 W 2.5% 7.64 % B. 30 A/11KV Cop. 1% 180 W 1340 W 2.6% 7.75 % C. 45 A/11KV Cop. 1% 230 W 1840 W 2.6% 7.75 % Note : In actual execution if a unit records higher losses i.e. beyond permissible tolerance, the same will be rejected. 8.2 TEMPERATURE RISE LIMIT : a) Temperature rise in top oil by thermometer. : 40 C Max. b) Temperature rise in winding by resistance method : 50 C Max. 9. BUSHING AND METAL PARTS : The HV porcelain bushings and metal parts shall be as per following IS: IS 5621/80 IS 7421/88 IS 2099/86 IS 3347 (Part III/ Sec. I / 1988) IS 3347 (Part -I/ Sec. I / 1979) IS - 3347 (Part III/ Sec. II / 1982) The metal parts shall be made from drawn or rolled quality tinned brass or copper of electro plated. 10. TRANSFORMER OIL : The Transformer oil to be supplied as first filling of transformer shall comply with IS-335/1987 11. TRANSFORMER TANK : 11.1 The tank will be made of prime quality MS sheet of thickness stated below with necessary stiffener to withstand the pressures built in during the expansion of oil due to temperature rise.

11 KV Rating Minimum thickness of plate in mm For sides For Top & Bottom 24 Amps 3.15 5 30 Amps 4.50 5 45 Amps 4.50 5 11.1 The exterior of the transformer tank and other ferrous fittings shall be thoroughly cleaned, scraped/ sand blasted and given a priming coat and two finishing coats of durable oil and weather resistant paint of light admiralty Gray conforming to colour code No. 697 of IS-5/1978. 11.1.2 Inside of the tank shall be thoroughly cleaned/scrapped/sand blasted and coated with oil resistant paint or epoxy coat or phonemic / melamine varnish coat. These protective coats shall not contaminate the oil due to due to peeling or decomposition during the life of the transformers. 11.1.3 All the screws, bolts and nuts exposed to atmosphere shall be hot dip galvanized if diameter is 12 mm or more. They shall be either electro galvanized or hot dip galvanized if diameter is less than 12 mm. The screws and clamps for fixing HV bushing shall also be electro-galvanized. The inside dimension of the tank and shape to clearly indicated in the drawings. Only positive 5% tolerance will be allowed in actual fabrication of tank, no negative tolerance will be allowed. 12. CORE : 12.1 CORE MATERIALS : Non edging, oxide film coated CRGO laminations of prime quality shall be used as core material. 12.2 CONSTRUCTION : 12.2.1 Core shall be so constructed that there are adequate vertical cooling ducts to cool the core. The core when vertically standing shall be rigid. Insulated core / type bolts shall be provided wherever necessary. 12.2.2 The core shall be so constructed that the air-gaps in all the limbs are identical. 12.2.3 FLUX DENSITY : The flux density shall be so selected that over fluxing is limited to 5% over voltage (Max. 1.9 Tesla)

12.2.4 NO LOAD CURRENT : The percentage no load current shall be as under : Minimum percentage no load current at Normal voltage 5% over voltage 24 Amps 1 2 30 Amps 1 2 45 Amps 1 2 13 WINDING : This is generally of round wire and coils are in form of packets and number of coils are connected in series to achieve the necessary voltage ratio. The coils assembly should be sand with type The number of coils per limb shall depend upon the necessary cooling surface and the mechanical strength. 13.1 CONNECTION : The coil series connections shall be crimped / brazed or screw connected after thoroughly cleaning the ends. The joint in the coil shall be buttwelded. However the brazing of copper wire shall be acceptable. All connections shall be insulated by paper wrapping, leads shall be properly supported and secured in place avoiding accidental short circuit. Coils supports shall be of rigid non-compressible insulating material. 14. ASSEMBLY : The core and coil assembly shall be supported by press channels and the coils fully pressed by the tie rods. Guides on all the four sides shall be provided to prevent shifting of the active parts and thereby accidental touching the tank. 15. DRAWING : The Tenderer shall submit the following drawings along with offer. 15.1 GENERAL ARRANGEMENT : G.A. drawing showing fittings shall be furnished. The details of cooling system, viz. Number of cooling tubes radiators, their size and position on tank must be very clearly indicated. The details on drawing shall be in line with G.T.P.

16. TERNIMAL ARRANGEMENT : 17. The HV bushings shall be of approved makes. (please refer Appendix A for approved suppliers) 17.1 TERNIMAL ARRANGEMENT : (a) Phase to phase (b) Phase to earth H.V. 11 KV 255mm 205mm 18. ROUTINE TESTS : All routine tests as per Appendix C attached. 19. DEVIATION FROM SPECIFICATION : There shall be no deviatio0n from these specifications, norms and procedures. However, if tenderer to do so, the same shall be indicated only of the guaranteed technical particulars. 20. PACKING : The packing shall be robust enough for the rough handling which is normal during rail / road transport. The details of the packing are however, left kto the discretion of the manufacturer. 21. GUARANTEED TECHNICAL PARTICULARS (GTP) : Tenderer should submit the details in Appendix B attached. 22. ESTING INSTRUMENTS : The class of accuracy of instruments shall be as under : (a) Watt meters - 0.2 class or better (b) Voltmeter & Ammeter - 1.0 class or better 23. GUARANTEE & WARANTEE : The guarantee period shall be 12 months from the date of supply for the manufacturing defect. If the transformer fails during guarantee period the supplier should arrange to repair the failed transformer with in one month on receipt of GP failed transformer at their works. To and fro arrangement shall be made by the Company. 24. TESTING OF TRANSFORMER OIL : The sample of transformer oil to be drained from one of the transformer selected randomly from the lot offered for inspection and the test results must match as per IS 335 / 1987.

A P E N D I X A APPROVED SUPPLIERS FOR VARIO9US MATERIALS ARE AS UNDER: (1) Bushings : H.V. 1. BEPCO 2. JAYASHREE 3. W.S.I. 4. ASSOCIATED PORCELAIN (Only 11KV) 5. SESHASAYEE 6. JAIPUR GLASS (Only 11KV) 7. LUSTER CERAMICS NOTE : Embossing showing the manufacturer s name should be clearly visible, even after fixing the same on transformer. (2) Insulation Paper : (1) Triveni Tissus or any other reputed make (2) Any other reputed imported make (3) Insulating Materials : (1) Senapati Whitely (2) Raman Boards (3) Shalimar (4) Permali-Wallace (5) Wipro

A P P E N D I X B Manufacturers name and address : G.T.P. Sr.No. Particulars Confirmation 1 It shall be conventional 2. Voltage H.V. 11000 3. Impulse withstand voltage of 75 KV Peak for 11 KV Class. 4. Transformers shall Copper windings except below 30 Amps 11 KV Class which shall have Aluminum winding. 5. Insulation Class A 6. a) Top oil temperature rise limit of 40 C by thermometer with feeding of guaranteed load loss plus tolerance converted to 75 C and guaranteed no load loss plus tolerance. b) Temperature rise limit of 50 C of winding by resistance method. 7. LOSSES & IMPEDANCE : 7.1 Maximum no load current & losses at 50 HZ and rated voltage Rating Winding No-load current No load losses at rated voltage & frequency A. a) 24 A/11KV b) 24 A/11KV Al. Cop. 1% 1% 171 W 160 W B. 30 A/11KV Cop. 1% 180 W C. 45 A/11KV Cop. 1% 230 W

7.2 Maximum load losses at full load in watts & maximum percentage impedance at 75ºC Rating Winding Load losses at 75 C Impedance at 75 C Y-B Short Y-B Short A. a) 24 A/11KV b) 24 A/11KV Al. Cop. 1250 W 1140 W 2.5 % 2.5% 7.64 % 7.64 % B. 30 A/11KV Cop. 1340 W 2.6% 7.75 % C. 45 A/11KV Cop. 1840 W 2.6% 7.75 % 7.3 Operating flux density at 50 Hz : 1.69 Tesla Max 7.4 Percentage no/load current (Max) at normal voltage and frequency a) 24 Amps 1 b) 30 Amps 1 c) 45 Amps 1 7.5 ----- do ------- but at 105% normal voltage a) 24 Amps 2 b) 30 Amps 2 c) 45 Amps 2 8. Pressure test of tank as per IS-1180 Part - I 9. Outside paint Light admiralty Grey as per IS 5 colour code 697. 10. Transformer oil shall conform with IS 335/1987 11. Only GUVNL approved make of HV Bushing shall be used. 12. Minimum external clearance as under shall be maintained. 11 KV (a) HV Phase to phase 255mm (b) HV Phase to earth 205mm 13. Thickness of sheet metal in mm for tank shall be following minimum Ratings Sides Top & Bottom a) 24 Amps 3.15 5 b) 30 Amps 4.50 5 c) 45 Amps 4.50 5