MODEL AT-10 ANALOG TRANSMITTER

Similar documents
Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Installation and Operating Manual

INSTALLATION & OPERATING MANUAL. AT 08 Analog Transmitter

RENATO DESIRÒ PARABIAGO (MI) Via Sant Anna, 51 Tel Fax

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

Series APD4059. For Load Cells/Pressure Transducer Transmitters. Field Rangeable, with Calibration Resistor. Standard Features.

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

HUMITRAN-RHT & RH RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER RELATIVE HUMIDITY TRANSMITTER

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

MODEL 421 Over/Under Motor Load Monitor

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

INSTALLATION & OPERATION MANUAL

CEC VIBRATION TRANSMITTER

INSTRUCTION MANUAL CLEVELAND-KIDDER TENSION INDICATOR SERIES AO REVISION

SC-FI Series Frequency to Current Signal Conditioner

Non-Submersible Industrial Pressure Transducer

FC Series Signal Conditioners

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

MODEL: M2DYS SEN TRONIC AG

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

Model A. DIN Rail Strain Gage Conditioner. Installation and Operating Manual

Sealed Interface Control: EC20300

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

ARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS

Electro Controls. Input-Output Modules WattsIndustries.co.uk

LAUREL ELECTRONICS, INC.

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

USB-2404-UI Specifications

DRG-SC Series Signal Conditioners

EN SERIES NEMA CASED DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Load Cell Accessories and Services

RHS SERIES RH Set Point Controller/Probe

BC145 SIGNAL ISOLATOR BOARD

TRANSMITTER CSA CSA CSA-528. Instruction Manual EN C III

DC Current Transducers

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

FC-33, DC SELECTABLE SIGNAL CONDITIONER

INSTRUCTIONS PS2500 POWER SUPPLY

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

MAGTROL. LMU Series Load Monitoring Units. LMU Data Sheet. Description. Features

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Economical Digital Indicators For Process and Electrical Measurement

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

OPERATION MANUAL LDM-1000

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

Analogowy przetwornik wzmacniający dedykowany dla czujników tensometrycznych RQA INSTALLATION MANUAL. Rev. 0.2

670K9 SORtrax Level Transmitter

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

C 2030 חפר מיכשור ומערכות בע"מ טכנולוגיות לטיפול במים ושפכים מיכשור אנליטי למדידה ובקרת תהליכים OPERATOR'S MANUAL. 2- Wire E.C transmitter Din Rail

ISOLATED 4-20 ma TRANSMITTERS

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

SPECIFICATION, CONTROLS AND ACCESSORIES

Model 1791 VHF Radio User's Manual

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Delta Style Room Humidity Units

Installation & Operation Manual

AD-8100 & AD-8200 Servo Amplifiers

PANEL MOUNT PROCESS METER IDP

FREQUENCY => CURRENT / VOLTAGE CONVERTER Z111

True RMS Bench Multimeter 5492B

Princo MagneLevel Model LML

TRANSDUCER IN-LINE AMPLIFIER

DIN Thermocouple Conditioner MODEL 5M14(V)

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Output Signal Active Note. Output Signal Temperature 22UTH-51 DC V, DC V

RK PPM Hexane Transmitter Operator s Manual

Torque Sensor Accessories and Services

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

GTT 25A - 40A - 60A - 90A - 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL

ELKOR MOC1 TRANSDUCER SET - MANUAL

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Strain gauge amplifier

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

Meriam Model M ma Loop Calibrator Operating Instructions

INSTALLATION & OPERATION MANUAL

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

TRANSMITTER CSA-522B. Instruction Manual EN E

P1-04ADL-2 Analog Input

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

CAP ANALOG 410 INSTALLATION & OPERATION MANUAL

12/4/ X3 Bridge Amplifier. Resistive bridge amplifier with integrated excitation and power conditioning. Logos Electromechanical

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu

1-830 SERIES DISPLACEMENT TRANSMITTER

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

LVC Low Voltage Conditioner. User Manual

ISOLATED AC/DC POWER SUPPLY

B850 Boiler House Energy Monitor

CX105 Conductivity/Resistivity Transmitter

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

Installation, Operation and Maintenance Manual

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

M2/M2A AC-DC Power Supply Operator s Manual

Transcription:

MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca 12

SECTION I GENERAL INFORMATION FIGURE 4 Model 121 Power Supply Introduction The Model AT-10 Analog Transmitters are electronic devices utilizing solid-state integrated components. They provide the user with a selectable voltage or current output directly proportional to the input signal within a specified linearity. Description The transmitters are intended for field mounting close to the vessel site, thereby reducing installation costs. An integral 20-position terminal strip provides connections for up to four transducers, thus eliminating the need for a separate summing junction box. Two screw type terminal strips provide connections for the supply voltage, transducer wiring, and analog outputs. The zero and span adjustments for the analog outputs are accomplished with two sets of dip-switches and trim pots. The units also include an adjustable filter which can be used to stabilize the output. Filtering is used to minimize the effects of vibration caused by agitators or other devices. Each unit is set to customer specifications or factory standards prior to shipment in order to provide a fully tested and working instrument. Should a change be required, or to verify the initial settings, please follow the procedures outlined in Section II of the manual. The standard packaging is an ABS plastic DIN-Rail mounted enclosure. Optional field-mounted, fiberglass or type 304 stainless steel NEMA-4X enclosures are available. The transmitters are available with an optional 24 Vdc power supply enabling the unit to be operated with 115 Vac. For additional information, please refer to Section III of the manual. Fuse Replacement Fuse L N LED + + - - 115 Vac 24 Vdc The following procedures require work inside the power supply enclosure and should be performed by qualified service personnel. Before opening the unit, disconnect the AC voltage. Remove the front cover from the power supply. Press down gently on the cover of the fuse holder, and turn counter-clockwise. Pull out the cover and fuse as an assembly, replace fuse with a new one. Re-install fuse and cover as an assembly, press down gently and turn clockwise. Replace the front cover on the power supply. Re-apply AC voltage to the unit. In the event of a malfunction, please contact the nearest distributor for assistance. Any attempt to modify or repair the power supply will void the manufacturers warranty. 2 11

Power Input Voltage Output Voltage Power Consumption Fuse Isolation Environmental Operating Temp. Range Storage Temp. Range Relative Humidity Enclosure Dimensions (L x H x D) Mounting Material Weight Installation SECTION III OPTIONS Precise Model 121 24 Volt Power Supply Specifications 115 Vac, 50/60Hz 24 Vdc (norminal) 10 VA maximum 200 ma Class II +14 to +104ºF (-10 to +40 C) -4 to +122ºF (-20 to +50 C) 85% non-condensing 2.75" x 3.50" x 2.25" DIN-Rail mount ABS Plastic 12.5 Ounces Make sure the installation complies with local regulations and electrical codes. Connect AC voltage to the terminals marked L and N. The DC voltage is available on the terminals marked + and -. The second set of terminals are used when powering two transmitters from a single power supply. A red LED is illuminated when the power supply is ON. Refer to Figure 4 on the following page for terminal locations. Power Power Supply Load Cell Excitation Load Current Power Consumption Amplifier Input Signal Output Signals Voltage Current Maximum Gain Coarse Zero Fine Zero Coarse Span Control Fine Span Control Linearity Analog Filter Environmental Operating Temp. Range Storage Temp. Range Thermal Stability Relative Humidity Enclosure Dimensions (L x H x D) Mounting Material Weight Wiring connections Options 115 Vac power supply NEMA 4X Enclosure Specifications 24 Vdc + 15% 10 Vdc 200 ma (4 load cells x 350Ω) 6 VA Selectable, 10mV, 20mV, 30mV Selectable (Internal jumper J1) 0-10 Vdc (2KΩ min load) 4/20 ma (500Ω load max) 4000 4-position dip-switch 20-turn trim-pot 4-position-dip switch 20-turn trim-pot + 0.02% FS Adjustable, 270 turn trim-pot +14 to +104ºF (-10 to +40 C) -4 to +122ºF (-20 to +50 C) 20 ppm/ C 85% non-condensing 5.0" x 3.5" x 2.5" DIN-Rail mount ABS Plastic 7.5 Ounces Terminal blocks, pitch 0.196 DIN-Rail mounted, (See pg. 10) Wall mounted, 10 x 8 x 4 NOTE: All specifications are subject to change. 10 3

TABLE 2 Span Adjustment Dip-switches 1 2 3 4 mv min mv max OFF OFF OFF OFF 2.6 2.8 ON OFF OFF OFF 2.8 3.0 OFF ON OFF OFF 3.0 3.2 ON ON OFF OFF 3.2 3.5 OFF OFF ON OFF 3.4 3.7 ON OFF ON OFF 3.7 4.0 OFF ON ON OFF 4.0 4.4 ON ON ON OFF 4.3 4.9 OFF OFF OFF ON 4.8 5.4 ON OFF OFF ON 5.3 6.1 OFF ON OFF ON 5.9 7.0 ON ON OFF ON 6.8 8.2 OFF OFF ON ON 7.8 9.7 ON OFF ON ON 9.3 12.2 OFF ON ON ON 11.6 16.5 ON ON ON ON 15.2 24.7 FIGURE 3 Analog Filter Adjustment Filter Adjustment J2 removed = No Filtering J2 installed = Filter Activated 9 4 J2 FIGURE 1 Wiring Connections 26 25 24 23 22 21 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Mount the transmitter horizontally on a section of DIN-Rail with Terminal Block positioned on the bottom. If an optional 115 Vac to 24 Vdc power supply is used, the cable between the two devices must not exceed 3 feet.

Calibration Procedure (cont d) Apply a known weight and adjust the fine span trim pot for the correct output. Turning the trim pot clockwise increases the output while turning it counter clockwise decreases the output. Re-check zero and span calibration and re-adjust if required. Replace the metal cover after calibration has been completed. Analog Filter Adjustment If the output is unstable under normal operating conditions, slowly turn the filter adjustment clockwise until the output stabilizes. See Figure 3 for location of the filter adjustment. TABLE 1 Zero Adjustment Dip-switches 1 2 3 4 mv min mv max OFF OFF OFF OFF -0.8 1.6 ON OFF OFF OFF 1.2 3.7 OFF ON OFF OFF 3.0 5.5 ON ON OFF OFF 4.6 7.1 OFF OFF ON OFF 5.9 8.4 ON OFF ON OFF 7.2 9.7 OFF ON ON OFF 8.3 10.8 ON ON ON OFF 9.3 11.8 OFF OFF OFF ON 10.2 12.8 ON OFF OFF ON 11.0 13.6 OFF ON OFF ON 11.8 14.3 ON ON OFF ON 12.5 15.0 OFF OFF ON ON 13.1 15.7 ON OFF ON ON 13.7 16.2 OFF ON ON ON 14.3 16.8 ON ON ON ON 14.8 17.3 8 5 The Model AT-10 is designed to be installed in the field close to the vessel. Terminal strip provides connections for up to four transducers, thereby eliminating the need for a separate summing junction box. 1. - Excitation (cell # 1) 11. - Excitation (cell # 3) 21. + 4/20 ma 2. + Excitation (cell # 1) 12. + Excitation (cell # 3) 22. + 0-5 / 0-10 Vdc 3. - Signal (cell # 1) 13. - Signal (cell # 3) 23. - Analog Output 4. + Signal (cell # 1) 14. + Signal (cell # 3) 24. - 24 Vdc (supply) 5. Shield 15. Shield 25. + 24 Vdc (supply) 6. - Excitation (cell # 2) 16. - Excitation (cell # 4) 26. Ground 7. + Excitation (cell # 2) 17. + Excitation (cell # 4) 8. - Signal (cell # 2) 18. - Signal (cell # 4) 9. + Signal (cell # 2) 19. + Signal (cell # 4) 10. Shield 20. Shield NOTE: Some transducer manufacturers utilize a 6-conductor cable (+/- Sense leads). When using these type of transducers, the + Sense lead must be connected to the + Excitation terminal and the - Sense lead must be connected to the - Excitation terminal.

SECTION II CALIBRATION Prior to calibrating the instrument perform the following calculations. This will enable you to determine where the dip-switches should be positioned for zero and span. Obtain the capacity and full scale output of the transducer/s from the calibration certificates. If required, convert them into the engineering units being used in the system. Use the above values in the following formulas to determine the zero and span mv values. Multiply the full scale mv/v output of the transducer/s by the excitation voltage to obtain mv. Example: 3.0 mv/v x 10 Vdc = 30 mv. Zero (mv) = Z x O / C Z = Tare weight (vessel, agitator, etc) O = Full scale output in mv C = Total capacity of the transducers. Set the zero adjustment dip-switches so the calculated value is within the minimum and maximum mv ranges given in Table 1. Span (mv) = S x O / C S = Net weight (live or product weight) O = Full scale output in mv C = Total capacity of the transducers. Calibration Procedure Remove the metal cover to expose the dip-switches, jumpers and trim pots as shown in Figure 2 below. Set the zero and span dip-switches so the calculated values are within the minimum and maximum mv ranges given in Tables 1 and 2. Position jumper J1 for current or voltage output. See Figure 2. Connect a digital multi-meter to terminal strip terminals 21 and 23 for current output or to terminals 22 and 23 for voltage output. Apply power to the unit and allow a couple of minutes for the transmitter to warm up before making any adjustments. Remove any weight from the system and adjust the fine zero trim pot for a reading 0 Vdc or 4 ma. Turn the trim pot clockwise to increase the output, or counter-clockwise to decrease the output. FIGURE 2 Zero & Span Adjustments Set the span dip-switches so the calculated value is within the minimum and maximum mv ranges given in Table 2. J1 installed = 4/20 ma J1 removed = 0-10 Vdc J1 Sample calculation: ZERO ADJ. SPAN ADJ. Three 1000 lb. load cells, output = 3.0 mv/v Tare weight = 500 Lbs. Net weight = 2000 Lbs. 3.0 mv/v x 10 Vdc = 30 mv Zero (mv) 500 Lbs. x 30 mv / 3,000 Lbs. = 5 mv Table 1 dip-switch setting = Off, On, Off, Off (3.0 to 5.5 mv) Span (mv) 2000 Lbs. x 30 mv / 3,000 Lbs. = 20 mv Table 2 dip-switch setting = On, On, On, On (15.2 to 24.7 mv) 1 2 3 4 1 2 3 4 6 7