Validation of spectral response polychromatic method measurement of full size photovoltaic modules using outdoor measured data

Similar documents
Initial solar cell characterisation test and comparison with a LED-based solar simulator with variable flash speed and spectrum

Effect of I-V translations of irradiance-temperature on the energy yield prediction of PV module and spectral changes over irradiance and temperature

Review of uncertainty sources in indoor PV calibration of c-si, and thin film single junction and multi junction cells and modules

Voltage-dependent quantum efficiency measurements of amorphous silicon multijunction mini-modules

Loughborough University Institutional Repository. This item was submitted to Loughborough University's Institutional Repository by the/an author.

Accessing the performance. light processing projector

Determining spectral response of a photovoltaic device using polychromatic filters

Performance of high-eciency photovoltaic systems in a maritime climate

Development of a solar cell spectral response mapping system using multi-lbic excitation

Advantages in using LEDS as the main light source in solar simulators for measuring PV device characteristics

Spectrally Selective Sensors for PV System Performance Monitoring

Primary Calibration of Solar Photovoltaic Cells At the National Metrology Centre of Singapore

Actual PV module performance including spectral losses in the UK

Impact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates

Optimising Layer Thickness of Multi-Junction Silicon Devices for Energy Production in a Maritime Climate

Radiometric Measurement Traceability Paths for Photovoltaic Calibrations. Howard W. Yoon Physical Measurement Laboratory NIST

INDOOR AND OUTDOOR CHARACTERIZAITION OF a-si:h P-I-N MODULES

PORTABLE LED FLASHER WITH IMPLEMENTED BYPASS DIODE TESTER

The Effect of Photon Flux Density and Module Temperature on Power Output of Photovoltaic Array

Solar Simulation Standards and QuickSun Measurement System. Antti Tolvanen Endeas Oy

PHYS General Physics II Lab Diffraction Grating

Solar Cell Parameters and Equivalent Circuit

Power Rating of Multi-junction Solar Cells: Focus Thin Film

Project full title: "Nanowire based Tandem Solar Cells" Project acronym: Nano-Tandem Grant agreement no: Deliverable D6.1:

Stitched transmission lines for wearable RF devices

Actual issues on power measurement of photovoltaic modules

Bending vibration measurement on rotors by laser vibrometry

Optical design of a low concentrator photovoltaic module

APPLICATION NOTE. The Challenge of Making Reliable Solar Cell Measurements. Technology and Applications Center Newport Corporation

Designing practical on-site. on-site calibration protocols for acoustic systems: key elements and pitfalls.

CHARACTERIZATION OF CPV CELLS ON A HIGH INTENSITY SOLAR SIMULATOR: A DETAILED UNCERTAINTY ANALYSIS

CES Solar Cell Testing Centre, Pilot Plant Development and Training Institute (PDTI), Thailand 3

How to Evaluate PV Project Energy Yield

USER S GUIDE. for MIDDLETON SOLAR SECONDARY STANDARD PYRANOMETER WITH INTEGRATING CAVITY DETECTOR

PhysicsAndMathsTutor.com 1

Large Area Steady State Solar Simulator - Apollo

UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells

The European Commission s science and knowledge service

Performance Loss of PV systems. Giorgio Belluardo

Updating to remain the same: Habitual new media [Book Review]

A miniature reconfigurable printed monopole antenna for WLAN/WiMAX and LTE communication bands

Accurate determination of distribution network losses

CHAPTER-2 Photo Voltaic System - An Overview

The Standard for over 40 Years

Cylindrical electromagnetic bandgap structures for directive base station antennas

Program for UV Intercomparison 2014 in Davos:

The University of Toledo R. Ellingson and M. Heben

Representing human movement and behaviour in virtual environment using gaming software

Laboratory 2: PV Module Current-Voltage Measurements

Design and operation influences regarding rise and fall time of a photoconductive microwave switch

Making the Invisible Visible: New Luminescence Inspection Technology for PV Production

RGB Laser Meter TM6102, RGB Laser Luminance Meter TM6103, Optical Power Meter TM6104

Loughborough University Institutional Repository. This item was submitted to Loughborough University's Institutional Repository by the/an author.

WIDE SPECTRAL RANGE IMAGING INTERFEROMETER

Chromatic Modulation Based Acoustic Analysis Technique. For In-process Monitoring Of Laser Materials Processing. Submitted for

Design, construction and characterization of a steady state solar simulator

Supporting Information A comprehensive photonic approach for solar cell cooling

High-speed Micro-crack Detection of Solar Wafers with Variable Thickness

Environmental control by remote eye tracking

CHAPTER 3 CUK CONVERTER BASED MPPT SYSTEM USING ADAPTIVE PAO ALGORITHM

Proprietary Calibration Certificate

Antenna frequency and beam reconfliguring using photoconducting switches

BLACKBODY RADIATION PHYSICS 359E

A case study analysis of the application of design for manufacture principles by industrial design students

Operating Instructions for ISSI Series LM2X, LM2X-DM, LM2X-DMHP

IEC : Measurement of current-voltage characteristics of bifacial photovoltaic devices

THE spectral response (SR) measurement of a solar cell is

I D = I so e I. where: = constant T = junction temperature [K] I so = inverse saturating current I = photovoltaic current

GEO-SolarSIM-D2 and SunTracker-2000/3000

apogeeinstruments.com Introducing the PV-100 PV Monitoring Package

Investigation of the effect of metallic frames on 4G eyewear antennas

Color Measurement with the LSS-100P

Review and Adjudication Information. Group: DSSC/OPV Task Force Taiwan PVTC Chapter Date: TBD Aug 6, 2015 Time & Time zone: TBD

B. Cavity-Enhanced Absorption Spectroscopy (CEAS)

Failure modes and effects analysis through knowledge modelling

Reconfigurable antenna using photoconducting switches

Tunable narrowband filters with cross-shaped resonators for THz frequency band

Characterisation of Photovoltaic Materials and Cells

Solid State Luminance Standards

CHAPTER 4 PERFORMANCE ANALYSIS OF DERIVED SPV ARRAY CONFIGURATIONS UNDER PARTIAL SHADED CONDITIONS

SUPPLEMENTARY INFORMATION

Lumen lm 1 lm= 1cd 1sr The luminous flux emitted into unit solid angle (1 sr) by an isotropic point source having a luminous intensity of 1 candela

Bandwidth Enhancement through Fractals and Stacking of Microstrip Antenna for Ku-Band Applications

Cutting tools in finishing operations for CNC rapid manufacturing processes: simulation studies

Dr E. Kaplani. Mechanical Engineering Dept. T.E.I. of Patras, Greece

A Revision of IEC nd Edition Data Correction Procedures 1 and 2: PV Module Performance at Murdoch University

An acoustic emission slope displacement rate sensor: Comparisons with established instrumentation

1) Solar simulator with I-V measurement setup and software

Spectral Analysis of the LUND/DMI Earthshine Telescope and Filters

Dispersion measurement in optical fibres over the entire spectral range from 1.1 mm to 1.7 mm

Adaptive notch filters from lossless bounded real all-pass functions for frequency tracking and line enhancing

Quantum Efficiency Measurement System with Internal Quantum Efficiency Upgrade

Part 1: New spectral stuff going on at NIST. Part 2: TSI Traceability of TRF to NIST

\Ç à{x ÇtÅx Éy ALLAH à{x `xüv yâä

JAWIRA TIMUR SDN. BHD.,

PoS(PhotoDet 2012)058

Bifacial Outdoor Rotor Tester- BIFROT

Multi-Wavelength Laser Sensor for Intruder Detection and Discrimination

High Power Pulsed Laser Diodes 850-Series

Advancements in solar simulators for Terrestrial solar cells at high concentration (500 to 5000 Suns) levels

Transcription:

Loughborough University Institutional Repository Validation of spectral response polychromatic method measurement of full size photovoltaic modules using outdoor measured data This item was submitted to Loughborough University's Institutional Repository by the/an author. Citation: AL HUSNA, H., 2016. Validation of spectral response polychromatic method measurement of full size photovoltaic modules using outdoor measured data. IN: Hutchins, M., Treharne, R. and Cole, A. (eds.) 12th Photovoltaic Science, Application and Technology Conference C98 (PVSAT-12), University of Liverpool, 6-8th April, pp 157-160. Additional Information: This is a conference paper. Metadata Record: https://dspace.lboro.ac.uk/2134/21736 Version: Accepted for publication Publisher: c The Solar Energy Society Rights: This work is made available according to the conditions of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) licence. Full details of this licence are available at: https://creativecommons.org/licenses/by-nc-nd/4.0/ Please cite the published version.

Validation of Spectral Response Polychromatic Method Measurement of Full Size Photovoltaic Modules using Outdoor Measured Data H. Alhusna*, A. Smith, T.R. Betts, R. Gottschalg Centre for Renewable Energy Systems Technology (CREST), Loughborough University, Loughborough, Leicestershire, LE113TU, UK * Corresponding Author: H.Alhusna@lboro.ac.uk Abstract This paper presents the validation of a polychromatic method of spectral response measurement applied to full size mono-crystalline silicon photovoltaic modules using outdoor measured data. The difference between short-circuit current modelled from the measured spectral response and outdoor spectral irradiance and the directly-measured current is below 5% which confirms the validity of the spectral response curve obtained using the polychromatic measurement method. Introduction Energy yield prediction of photovoltaic (PV) devices is important in order to design a PV system that can deliver maximum energy at specific location. For this, information about the characteristics of the device and meteorological data from the site are necessary. Depending on the material, generation of power in response to the incident spectral irradiance varies from one PV device to another. Therefore, it is important to know the spectral response characteristic of the device to evaluate energy yield estimation and even for making accurate spectral mismatch corrections for power rating at Standard Test Conditions. To date, there are very few reports available on the indoor spectral response measurement of a full size PV module using filter based monochromatic methods in a flasher system, because it is very challenging to achieve accuracy due to the high uncertainties in measurement, especially those due to low signal strength contributed by the employment of narrowband filters. The polychromatic measurement used here is a unique filter based method that can be applied to measure spectral response characteristics of large PV devices. Instead of narrowband filters, the method employs different broadband filters to create variation of spectral distribution incident on the device under test (DUT) while concurrently measuring the generated current. As a result, a relatively larger signal read out can be detected, and uncertainty due to transmitted signal can be improved. The determination of spectral response characteristics by this method is done by numerical modelling based on the measurements of spectral irradiance and current. The feasibility of this method has been demonstrated previously, where the modelled spectral response of small-area PV devices of different technologies showed a good agreement in comparison to the spectral response curves determined via a standard monochromatic method, within ±5% difference [1]. In this work, the polychromatic measurement method is applied to a full size PV module. Due to the high uncertainties in measurement of the spectral response characteristic monochromatically at such large areas, the validation of the polychromatic method is performed indirectly by comparison of short-circuit currents measured outdoors under a range of different natural spectra to those modelled with the spectral response characteristic determined indoors with the polychromatic method. Polychromatic spectral response measurement The modelling of spectral response curve of PV device by polychromatic method is carried out in two steps which are optical/electrical measurement and numerical fitting. The description of these is discussed in the following. The type of PV module measured in this work is of mono-crystalline silicon, with dimensions 1.6m 0.8m. Spectra and current measurement Measurement of current-voltage (I-V) characteristics of full size PV modules using a flash type solar simulator is common in the PV industry and in research laboratories. In such a system,

the uniformity of the projected light across the measurement plane is high, to meet simulator classification. For the Pasan 3b simulator as used at CREST, the nonuniformity is less than 2% over a measurement area of 2m 2m. The system is equipped with a filter cassette to house up to 20 filters and a filter shifting system adjacent to the main light source. This projects a uniform light across the measurement plane at 8m distance. during the same period as the I-V curve sweep. Fig. 3 illustrates the measured spectral irradiance of the Pasan spectral irradiance distribution transmitted through the broadband filters. Fig. 1 Image of light bulbs (right) and measurement rig (left) of the solar simulator used. A set of broadband filters have been selected for maximum variation in spectra, based on their transmission profiles. As can be seen in Fig. 2, the wavelengths of the cut-off type filters are evenly distributed across the wavelength range. These are supplemented with a smaller number of visible band colour filters. Most of the filters are made of cost-friendly thermoplastic material. This gives an economical advantage over the monochromatic filter based measurement method which requires a set of costly narrowband/interference filters to ensure a good quality measurements. Fig. 2 Transmission profile of the broadband filters. An AvaSpec-UL (Avantes) spectrometer is positioned in the measurement plane, with the optical input aligned with the DUT to measure incident spectral irradiance. Time delay issues (rise of flash pulse intensity and detector triggering) have been raised in a few reports as one of the major uncertainty contributions in spectral measurement of short-pulse light sources [2]. The unit used here however is triggered optically on the rising pulse edge, with a delay to acquire the spectrum Fig. 3 Spectral irradiance distributions used for spectral response determination, measured by Avantes spectrometer. The measured incident spectral irradiance of each filter and corresponding shortcircuit current generated by the DUT are organised as shown in Table 1 below. λ nm F1 F2 F13 257 0 0 0 304 0.0029 0.0034 0.0012 1176 0.0168 0.0434 0.0819 I sc (A) 5.5234 4.3188 1.0564 Table 1 Example of tabulated data of measured irradiance spectra and currents (each column is a different spectrum, each row a different wavelength). Fitting algorithm The determination of spectral response in this work utilises a Levenberg-Marquardt (LM) fitting tool to optimise the parameters of a Gaussian summation model of the device spectral response. The Gaussian model and measured irradiance spectra are used together to model a set of shortcircuit currents (one for each different spectrum). The error between the measured short-circuit currents and the modelled ones is evaluated as a sum of the squared differences and the LM tool is used to minimise this. The calculation of short-circuit current can be made using equation (Eq. 1) below: λ max I sc = A SR λ E λ d λ min λ (Eq. 1) Where A is the area of the PV device (or cell in the case of a series-connected string), SR λ is the spectral response characteristic, and E λ is the incident spectral irradiance. To model current values, SR λ in Eq. 1 is replaced with a Gaussian sum model (the SR model from

here onwards) as per (Eq. 2). E λ is filled with measured spectral irradiance data. N SR mod = a i exp [ (λ b i )2 i=1 (Eq. 2) 2c i 2 ] The LM fitting tool iteratively minimises the error between measured and modelled currents (Fig. 4). measured spectral response curve of the device of same technology (different size) which qualitatively confirms its validity. Fig. 4 Simplified flow chart illustrating the process of the fitting algorithm. This fitting algorithm is applied to spectra and current measurement data taken to model the spectral response curve. An additional algorithm to find a reasonable set of starting values is also applied before executing the main LM fitting tool, to ensure that the tool works reliably. Fig. 5 shows the result of modelled currents and its comparison with respective measured currents generated by the DUT for the different optical filters. The figure shows that the difference between the two falls in a relatively small band, ±2%. Fig. 6 Spectral response model curve plotted using final determined fitted parameters. Validation of modelled spectral response It is difficult to spectrally characterise a full size PV module due to the limitation of requiring extremely high power light sources to enable monochromatic separation. Even then, with single-pulse type sources (as are the majority of solar simulators at this scale) one cannot employ standard techniques for extracting information from low signal-to-noise measurements (eg: phase locked loops) [3]. On account of this, the validation of the polychromatically-determined spectral response is performed by means of shortcircuit current comparison (modelled from the spectral response and actual measurements) of a module of the same manufacturer, model number and production batch which has been operated outdoors with concurrent outdoor spectral irradiance measurements. Outdoor data measurement Fig. 5 Comparison of measured and modelled currents of the DUT under each filtered spectrum. The final result of the modelled spectral response when plotted using the fitted parameters output by the LM fitting tool is illustrated in Fig. 6. The modelled spectral response curve indicates that the DUT is most responsive in the near infrared, which is sensible since it is made from mono-crystalline silicon material. It also has a relatively similar shape to the monochromatically Fig. 7 Outdoor PV performance and meteorological data monitoring system. The outdoor PV module performance monitoring site at CREST is equipped with pyranometers and spectrometers to record the meteorological conditions experienced

by the modules. All the modules and detectors used for this work are fixed on a rack with 35 inclination, facing south. Fig. 8 illustrates the inclined irradiance shift throughout one cloudy day (27/02/2016), recorded by the pyranometer. The maximum irradiance of the day is recorded at around mid-day, when the solar zenith angle is small, despite the relatively intense cloud cover condition (high irradiance fluctuation). Current calculation and comparison Eq. 1 is again used to calculate the current at the 3 selected conditions. In this case, spectral data recorded by the EKO is substituted for E λ, and the polychromatic spectral response for SR λ. Short-circuit current measurements of the PV module under these conditions are extracted from the monitoring data and compared with the respective modelled currents. The result for this is shown in Fig. 10. The overall difference between modelled and measured currents is below 5%. The highest difference is observed at the time of the lowest current generation, which is reasonable since low signal contributes to higher uncertainty in the spectral measurements. Fig. 8 Inclined irradiance shift over different meteorological conditions for a day. For this validation work, 3 set of spectral distributions at 3 different conditions of the day (as presented in Table 2) are selected by looking at Fig. 8, to be used for shortcircuit current modelling. Time Condition 11:02 Low irradiance, mild cloud cover 12:00 High irradiance, mild cloud cover 13:55 Low irradiance, heavy cloud cover Table 2 3 selected points of the day and description of its meteorological condition. Outdoor spectral irradiance is recorded by an EKO MS700 spectrometer every minute within a 350nm-1050nm wavelength range. Fig. 9 shows the inclined spectral irradiance of the selected conditions, as measured by EKO. Fig. 10 Comparison of short-circuit currents measured outdoors and modelled using the polychromatic spectral response and measured spectral irradiance under different conditions. Conclusions The spectral response curve of a 1.6m 0.8m full size mono-crystalline silicon PV module has been determined using the polychromatic measurement method. The spectral response curve has been validated by comparison to actual currents recorded under 3 different outdoor conditions. The comparison between the two exhibits differences below 5%. The following step for this work is to perform a thorough uncertainty analysis on the method. References [1] H. Alhusna, A. Smith, M. Krawczynski, T. Betts and R. Gottschalg, Spectral Response Measurements of Photovoltaic Devices using a Pulsed Source Solar Simulator, in PVSAT-11, Leeds, 2015. Fig. 9 Variation of spectral irradiance distribution measured by EKO MS700 at different conditions. [2] F. Schubert, K. Klameth, S. Darou and D. Spinner, Meausurement uncertainties of a compact array spectrometer, Energy Procedia, vol. 77 (2015), pp. 179-186, 2015. [3] Measurement of spectral responsivity of a photovoltaic device (Part 8), IEC 60904-8, 2014.