Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

Similar documents
Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

Operating Instructions METRA HIT 1A/2A /1.10. Analog Multimeter

METRATESTER 5+ Tester for DIN VDE /6.15

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

MAVOWATT 4 Multifunction Power Meter

METRISO 5000 A/AK. High-Voltage Insulation Tester With Battery or Crank Generator Operating Mode. Option Z580A Crank Generator. Operating Instructions

SECULIFE SR PC Controllable Instrument for Measuring Safety-Relevant Characteristic Values of Electrical Devices /2.

METRAClip87 and 88 Clamp Multimeters

METRAClip85 and 86 Clamp Multimeters

Operating Instructions. METRAport 3A /6.09. Analog Multimeter

3B SCIENTIFIC PHYSICS

Operating Instructions CAMILLE BAUER METRAWATT METRAOHM /9.97. Low impedance resistance meas. instrument

PROFiTEST C Test Instrument per DIN VDE /8.14

METRAHIT WORLD. International TRMS Multimeter /2.16. Features

3B SCIENTIFIC PHYSICS

METRAHIT WORLD International TRMS Multimeter

AC/DC CLAMP METER USER S MANUAL

PROFiTEST C Test Instrument per DIN VDE /11.10

METRISO 5000 D-PI Digital High-Voltage Insulation Tester

USER'S MANUAL DMR-6700

SECULIFE HIT METRAHIT X-TRA OUTDOOR TECH PRO BASE TRMS Digital Multimeter

MS2030 CAT III 600 V A V AUTO RS232

METRAHIT T-COM Cable Multimeter for Measurements in Symmetrical Copper Cable Networks

PHV RO High Voltage Passive Probe. Instruction Manual

High precision measurement system for current and voltage IHC-A/B-RM01/03

Precipition Sensor with analogue Intensity Output ,

CLAMP MULTIMETER METRACLIP 85 ENGLISH. User s manual

Operating Instructions. METRAport 40S /1.13. Digital Multimeter

Operating Instruction

PKT 512A-RO High Impedance Passive Cable Divider

METRAHIT MULTICAL Multimeter, Calibrator

K1 K2. User's manual AC/DC CURRENT PROBE C H A U V IN A R N O U X AC/DC CURRENT PROBE. 1 mv/ma OFF 300V CAT II

TETRIS 1000 High Impedance Active Probe. Instruction Manual

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Multifunction AC/DC Voltage Tester

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

400 MHz Passive High-Voltage Probe R&S RT-ZH

30XR-A Professional Digital Multimeter Users Manual

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

METRAHIT EXTRA ETECH ESPECIAL EBASE High Resolution TRMS Digital Multimeter

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

400Amp True RMS AC Clamp Meter + NCV

BENNING. CM7 Electrical Tester. Service Information

CONTENTS MS2033A. 1.Introduction Safety Information...01

Operating Instructions METRA HIT 16I/L/T. Analog Digital Multimeter with Insulation Measurement /5.06

Operating Instructions METRAHIT 30M /3.15. Precision Digital Multimeter

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

POINTAX 6000L2 Point Recorder

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

METRAHIT T-COM Cable Multimeter for Measurements in Symmetrical Copper Cable Networks

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Precipitation Monitor ,

Multi range AC current clamps (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no

Digital Clamp Meter Model: &

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Model DIGITAL MULTIMETER

Multifunction Digital

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Data Sheet. RISH Max-14 Analog-Digital Multimeter. RISH Max-14 Analog-Digital Multimeter. Page 1 of 5. Rishabh Instruments 1 / 05 / IX / 1210 / B

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

DM-45 Digital Multimeter

LINAX 4000L Continuous-line recorder

Warning, refer to accompanying documents V CAT II Overvoltage category II device. CSA Canadian Standards Association

AMM-1022 Digital Multimeter USER`S MANUAL

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Fluke and

Measure voltage without test leads. Product Highlights

MW3105 DIGITAL CLAMP MULTIMETER

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

80i-110s AC/DC CURRENT PROBE

QUICK SETUP GUIDE SECULIFE HITAM

Advanced Test Equipment Rentals ATEC (2832)

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Sound Level Meter C.A 832

DMM8900 SERIES USERS MANUAL

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

Mini Clamp Meter Model:

Operator s Manual. PP016 Passive Probe

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

KMD-S04 Multímetro de bolsillo

MINI MCR-SL-UI-I-LP-NC

QUINT-PS-24DC/24DC/10

Power supply CP-E 24/2.5

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

ProfiScale MULTI Multimeter

Installation and Operating Instructions for Phase Demodulator Type _.2

MultiMeter-Pocket CAT III 1000 V

METRAHIT ISO TRMS Multimeter with Insulation Measurement

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Transcription:

Operating Instructions 3-349-298-15 3/11.09 METRAVOLT 7A Voltage Tester per IEC 61243-3 with Phase and Polarity Tester and Phase Sequence Indicator CAT IV GMC-I Messtechnik GmbH Südwestpark 15 90449 Nürnberg Germany Phone+49 911 8602-111 Fax +49 911 8602-777 E-Mail info@gossenmetrawatt.com www.gossenmetrawatt.com

1 2 4 3 5 6 7 8 1 Test electrodes (under protective covers) 2 LED display for voltages (> 50 V) and polarity 3 LED for phase test and phase sequence test 4 Moving-iron measuring element for exact voltage indication 5 LCD indicator for voltages of more than 24 V, phase test and phase sequence test 6 Name plate 7 Accessible electrode for phase test and phase sequence test (rear) 8 Key for LED display (2) and measuring element (4) Meaning of symbols on the instrument Warning concerning a point of danger! (Attention: observe documentation!) Indicates CE conformity VDE testing authority approval mark This device may not be disposed of with the trash. 2 GMC-I Messtechnik GmbH

Table of Contents Page 1 Application...3 2 Safety Precautions...3 3 General Information...5 4 Testing...5 4.1 General Information... 5 4.2 Testing voltage and polarity... 5 4.3 Tests with the Accessible Electrode... 6 5 Technical data...8 6 Maintenance...9 7 Repair and Replacement Parts Service, DKD Calibration Center and Rental Instrument Service...10 8 Product Support...10 1 Application The METRAVOLT 7A is a two-pole voltage tester with LCD indicator, a high-quality moving-iron measuring element and LED display. You can use the METRAVOLT 7A to measure DC and AC voltages in the rated voltage ranges specified on the name plate. Furthermore, you can determine polarity as well as phase and phase sequence. The casing is made of solid rubber and protects the internal measuring element against heavy shocks, water and dust. Thanks to its high degree of protection (IP65) the METRAVOLT 7A may even be used in rain. 2 Safety Precautions The METRAVOLT 7A has been approved by VDE test authorities for application of VDE GS marking. When used for its intended purpose, the safety of the operator, as well as that of the instrument, is assured. GMC-I Messtechnik GmbH 3

In order to maintain flawless technical safety conditions, and to assure safe use, it is imperative that you read these operating instructions thoroughly and carefully before placing your instruments into service, and that you follow all instructions contains therein. Observe the following safety precautions: The voltages indicated on the METRA- VOLT 7A are rated voltages. The voltage tester may only be used in systems working with those rated voltage ranges. Faultless indication of values is only guaranteed between -10 C and +55 C. Hold the instrument by the handles only, to avoid covering the display and touching the test electrodes before and during tests. Just before they are used, voltage testers need to be checked to ensure they function correctly. Carry out the function test and check the instrument at a known voltage source - e.g. a 230 V socket. If the display of one or several systems fails in the course of checking, the instrument must not be used again. The METRAVOLT 7A must not be switched on for more than 30 seconds. For the determination of phase conductors and phase sequence by means of the accessible electrode, the perceptibility of the display may be impaired, e.g. when using protection means against direct contact, in unfavourable locations, for example on wooden ladders or insulating floor coverings, as well as in unfavourable lighting conditions and in an improperly grounded AC voltage system. The voltage tester may only be opened by our repair and replacement parts service personnel. Voltage testers must be clean and dry. 4 GMC-I Messtechnik GmbH

3 General Information The METRAVOLT 7A is equipped with keys on both sides of its handles with which you switch on the measuring element and the LED display. Without pressing the keys the instrument performs high-resistance tests and while pressing them, low-impedance tests are performed. The specified rated voltage ranges refer to the three indicating systems LCD, LED and measuring element. 4 Testing 4.1 General Information Existing voltage is directly displayed on the LCD indicator when the keys are not pressed. You can also determine phase and phase sequence. The measuring element is switched on when you press both keys. The test current becomes low-resistive as a result of the added load. 4.2 Testing voltage and polarity! Attention! The maximum allowable on-time for voltage testing is 30 seconds. Note! The internal resistance of the METRA- VOLT 7A is very high when the keys are not pressed. In extreme cases, indication of inductive or capacitive voltages may occur which disappears when both keys are pressed. AC voltage When both test electrodes are placed on AC voltage within the rated voltage range, a V- symbol is shown on the LCD indicator. When both keys are pressed, the measuring element always indicates the r.m.s. value. In addition, light-emitting diodes signal existing voltages of 50 V or more. Both LEDs light up when AC voltage is present (±). GMC-I Messtechnik GmbH 5

DC voltage and polarity When both test electrodes are placed on DC voltage within the rated voltage range, a V- symbol is shown on the LCD indicator. When both keys are pressed, the measuring element indicates the value. In addition, one of the two LEDs signals voltages from 50 V onwards. Polarity is determined as follows: The LED marked + lights up when the test probe marked + is connected to the positive pole. 4.3 Tests with the Accessible Electrode With the accessible electrode (brass button rear under the measuring element), you can perform phase and phase sequence tests. The tests can be carried out with or without the keys pressed.! Attention! While working with the accessible electrode the perceptibility of the display may be impaired (see part 2 Safety Precautions ). Note! Tests performed with the accessible electrode are only possible in systems working with properly grounded AC voltage systems at voltages of at least 165 V to earth. 6 GMC-I Messtechnik GmbH

Phase Test The phase conductor is identified by establishing contact between the test electrode marked with +L1 and the conductor and by touching the accessible electrode Pol-L1- Sensor at the same time. If the triangle is shown on the LCD indicator, the conductor is energized. Note! If the other test probe (without + L1) is used during single-pole tests, the V symbol appears on the LCD indicator in addition to the triangle if voltage is applied. Depending on the location (insulated ground), the -symbol may be indicated as well. The symbols additionally indicated are meaningless in this case. Phase sequence test To determine the phase sequence between two phases in the 230/400 V 3-phase system by applying both test electrodes and touching the accessible electrode, proceed as follows: Search for the phase conductors using one pole (see phase test). Apply both test electrodes to two phase conductors (while pressing keys: approx. 400 V is indicated). Touch the accessible electrode with your finger. When phase L1 is applied to the test probe marked + L1, and phase L2 to the other test probe, the triangle lights up if rotation is clockwise. If the triangle does not light up, the direction of rotation is counter-clockwise. Note! If 230 V is indicated instead of 400 V (while pressing keys), the neutral conductor may have been contacted with one of the test probes. A simple way of checking is by exchanging the two test probes and briefly touching the accessible electrode several times. GMC-I Messtechnik GmbH 7

5 Technical data Nominal conditions of use Rated voltage range Rated frequency range Input resistance Current 24... 740 V 0... 100 Hz 1 M (57 k with measuring element activated) I S = 0,6 ma (13 ma with measuring element activated) Analog Indicator (Measuring Element) Type moving-iron element class 2.5 Display range 120... 740 V Limit deviation AC/DC: 2.5% with reference to the upper end scale value LCD and LED Indicators 2-pole measurement (24... 740 V): V signals that voltage is applied 1-pole measurement with accessible electrode (as from 165 V to earth): signals that phase is applied 2-pole measurement with accessible electrode (as from 165 V to earth): signals clockwise rotation 2 LEDs (50... 740 V) 2-pole measurement: LEDs signal voltages of more than 50 V: one LED lights up for DC voltage (also for polarity test), two LEDs light up for AC voltage Electrical Safety Measurement category Surge voltage withstand Test voltage CAT IV 740 V 12 kv 6.0 kv Electromagnetic Compatibility Interference emission/ Interference immunity IEC 61236 8 GMC-I Messtechnik GmbH

Ambient Conditions Operating temperatures Relative humidity Elevation 10... + 55 C < 85%, no condensation allowed max. 2000 m Mechanical Design Protection IP65 Extract from table on the meaning of IP codes IP XY (1 st digit X) Protection against foreign object entry IP XY (2 nd digit Y) Protection against the penetration of water 6 dust-tight 5 water jets Housing Impact-resistant, dustproof plastic housing Display cover unbreakable Connector cable between test probes Rubber-insulated flexible cable H07RNF, 1 m Dimensions Test probe with indicator: 274 mm 75 mm 47 mm Weight 460 g 6 Maintenance The METRAVOLT 7A is completely maintenance-free. Nevertheless, we would advise you to observe the following instructions for safe use: The voltage tester should be kept dry and clean. The plastic housing can be cleaned with a cloth dampened with isopropyl alcohol or soapy water. Device Return and Environmentally Compatible Disposal The instrument is a category 9 product (monitoring and control instrument) in accordance with ElektroG (German Electrical and Electronic Device Law). This device is not subject to the RoHS directive. We identify our electrical and electronic devices (as of August 2005) in accordance with WEEE 2002/96/ EG and ElektroG with the symbol shown to the right per DIN EN 50419. These devices may not be disposed with the trash. Please contact our service department regarding the return of old devices. GMC-I Messtechnik GmbH 9

7 Repair and Replacement Parts Service, DKD Calibration Center* and Rental Instrument Service When you need service, please contact: GMC-I Service GmbH Service-Center Thomas-Mann-Straße 20 90471 Nürnberg Germany Phone +49 911 817718-0 Fax +49 911 817718-253 E-Mail service@gossenmetrawatt.com This address is only valid in Germany. Please contact our representatives or subsidiaries for service in other countries. * Calibration Laboratory for Electrical Quantities DKD K 19701 accredited per DIN EN ISO/IEC 17025:2005 Accredited measured quantities: direct voltage, direct current values, DC resistance, alternating voltage, alternating current values, AC active power, AC apparent power, DC power, capacitance, frequency and temperature 8 Product Support When you need support, please contact: GMC-I Messtechnik GmbH Product Support Hotline Phone +49 911 8602-0 Fax +49 911 8602-709 E-Mail support@gossenmetrawatt.com Edited in Germany Subject to change without notice A pdf version is available on the internet 10 GMC-I Messtechnik GmbH