VOLTAGE WAVE QUALITY IN LOW VOLTAGE POWER SYSTEMS

Similar documents
1. Introduction to Power Quality

Section 11: Power Quality Considerations Bill Brown, P.E., Square D Engineering Services

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

Coupling modes. Véronique Beauvois, Ir Copyright 2015 Véronique Beauvois, ULg

PQ Monitoring Standards

Simulation Results of a Shunt Active Power Filter with Control Based on p-q Theory

Harmonic distortion analysis on the MV and LV distribution networks: problems, influencing factors and possible solutions

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 9

Power Quality Analysers

Power Quality in Metering

MEASUREMENT CAMPAIGN AND ASSESSMENT OF THE QUALITY OF SUPPLY IN RES AND DG FACILITIES IN SPAIN

Harmonic control devices. ECE 528 Understanding Power Quality

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

Fundamentals of Power Quality

An Introduction to Power Quality

POWER QUALITY AND SAFETY

SHUNT ACTIVE POWER FILTER

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Power quality as a reliability problem for electronic equipment

OPTIMAL DESIGN OF A SINGLE TUNED PASSIVE FILTER TO MITIGATE HARMONICS IN POWER FREQUENCY

Improve Power Factor and Reduce the Harmonics Distortion of the System

POWER QUALITY A N D Y O U R B U S I N E S S THE CENTRE FOR ENERGY ADVANCEMENT THROUGH TECHNOLOGICAL I NNOVATION

1C.4.1 Harmonic Distortion

Roadmap For Power Quality Standards Development

Power Quality Basics. Presented by. Scott Peele PE

ENERGY SAVING WITH OPTIMIZATION OF VOLTAGE AND CURRENT QUALITY

Power Quality and Digital Protection Relays

Harmonic Filters for Single Phase Equipment

Southern Company Power Quality Policy

Laboratory no. 3 FLUORESCENT LAMPS FITTINGS

PowerMonitor 5000 Family Advanced Metering Functionality

Power Quality and Circuit Imbalances Northwest Electric Meter School Presented by: Chris Lindsay-Smith McAvoy & Markham Engineering/Itron

QUESTION BANK PART - A

DESIGN AND DEVELOPMENT OF ACTIVE POWER FILTER FOR HARMONIC MINIMIZATION USING SYNCHRONOUS REFERENCE FRAME (SRF)

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

CHAPTER 1 INTRODUCTION

POWER QUALITY SPECIFICATIONS AND GUIDELINES FOR CUSTOMERS ENGINEERING STANDARDS CITY OF LETHBRIDGE ELECTRIC

Analysis of Harmonic Distortion in Non-linear Loads

Power Factor and Power Factor Correction

Understanding Harmonics

POWER CORPORATION. Power Quality. Specifications and Guidelines for Customers. Phone: Fax:

Interharmonic Task Force Working Document

Design and Simulation of PFC Circuit for AC/DC Converter Based on PWM Boost Regulator

Low Pass Harmonic Filters

A Guide to Power Quality Testing

Power Quality Monitoring and Power Metering Tutorial

Introduction to Harmonics and Power Quality

Improving Passive Filter Compensation Performance With Active Techniques

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

Emicon Engineering Consultants L.L.C.

Voltage and Current Waveforms Enhancement using Harmonic Filters

p. 1 p. 6 p. 22 p. 46 p. 58

Harmonic Power. A VFDs.com Whitepaper Written by Ernesto Jimenez

Research and Trends in Power Quality

World Journal of Engineering Research and Technology WJERT

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Thyristorised Automatic Power Factor

COOPERATIVE PATENT CLASSIFICATION

Voltage Sags Evaluating Methods, Power Quality and Voltage Sags Assessment regarding Voltage Dip Immunity of Equipment

Power Quality Improvement using Passive & Active Filters

Technical Brief: Flow Direction of Harmonics and High- order Harmonics

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

Novelty Technique for Power factor Improvement by a Single phase Rectifier

The Use of an Active Power Filter for Harmonic Elimination and Power Quality Improvement in a Nonlinear Loaded Electrical Installation

Effective Harmonic Mitigation with Active Filters

Power Quality Study of Electrical Installation in Academic Institute Case Study

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans. Electronic Measurements & Instrumentation

Power quality report. A Manufacturing Plant

shunt (parallel series

1C.6.1 Voltage Disturbances

Poornima G P. IJECS Volume 3 Issue 6 June, 2014 Page No Page 6453

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

Literature Review for Shunt Active Power Filters

There s Gold in Those Waveforms Richard P. Bingham, Dranetz-BMI

MEASUREMENT METHODS OF THE CHARACTERISTICS AND TARGET VALUES OF THE VOLTAGE QUALITY SUPPLIED BY HYDRO-QUEBEC SYSTEM

Tripping of circuit breakers in PV installations due to zero sequence field impedance

Impact of Harmonic Resonance and V-THD in Sohar Industrial Port C Substation

An Introduction to the CSCT as a New Device to Compensate Reactive Power in Electrical Networks

The Impact of Connecting Distributed Generation to the Distribution System E. V. Mgaya, Z. Müller

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Alexandre A. Carniato, Ruben B. Godoy, João Onofre P. Pinto

Performance Analysis of Three Phase Cascaded H-Bridge Multi Level Inverter for Voltage Sag and Voltage Swell Conditions

ANALYSIS OF VOLTAGE TRANSIENTS IN A MEDIUM VOLTAGE SYSTEM

Fatima Michael College of Engineering & Technology

International Journal of Advance Engineering and Research Development ANALYSIS AND MITIGATION OF HARMONICS IN MEDICAL FIELD

Power Quality Monitoring using LabView

Power Quality Analysis in Power System with Non Linear Load

CHROMA ATE INC. Programmable AC Source 61500/61600 Series. Product Manager: Galen Chou

CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER

Performance Analysis of Passive Filter for Harmonics Due to Non-Linear Load in Power System

POWER QUALITY PRODUCTS FOR NON-LINEAR LOADS

Power Quality Report. A Manufacturing Plant

22.0 Harmonics in Industrial Power Systems

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

POWER QUALITY AND ENERGY EFFICIENCY IN LOW VOLTAGE ELECTRICAL POWER SYSTEM OF THE TECHNICAL UNIVERSITY OF GABROVO

Harmonic Analysis to Improve Power Quality

ABB DRIVES Technical guide No. 6 Guide to harmonics with AC drives

Transcription:

VOLTAGE WAVE QUALITY IN LOW VOLTAGE POWER SYSTEMS José M. R. Baptista, Manuel R. Cordeiro and A. Machado e Moura Department of Electrical Engineering U.T.A.D., Vila Real University Quinta de Prados, 5 Vila Real (Portugal) phone: +5 595, fax:+5 59548, e-mail: baptista@utad.pt, cordeiro@utad.pt Department of Electrical Engineering F.E.U.P., Engineering Faculty of Oporto University Rua Roberto Frias, 4 Porto (Portugal) phone: +5 5844 e-mail: mmoura@fe.up.pt Abstract. This paper deals with some disturbances that reach the electric power systems. These problems originated some interest due to the changes of the electric loads characteristics, which were predominantly electromechanical and today are predominantly non-linear. This is due to the electronic systems involved. Results of some measurements performed in electric grid of the Oporto Engineering Faculty Campus and in the University of Vila Real (UTAD) are presented and some solutions that had been implemented for the related problems minimization are also described. Key words Harmonic distortion, voltage sags, voltage fluctuations, flicker and active harmonic conditioner.. Introduction The vertiginous evolution of the technological society showed through the irreversible automation of the industrial processes, justified for the increase of the productivity, flexibility and industrial product quality. The electric power systems are subjected with increasing number of nonlinear loads. This evolution in the characteristic of loads allowed improvements in the quality of modern life and the production. These loads, at the same time that pollute the electric grid generating a series of impure signals and harmonics, are themselves more sensible to the effect created by these distortions.. Some problems that reaches the electric network A. Overvoltages An overvoltage is characterized by a drastic instantaneous increase of the voltage of the power system greater than percent at the power frequency, with short duration. Of all the critical events, the voltage peaks are the potentially most dangerous ones and are at the origin of great damages. Overvoltages are usually the result of load switching (e.g., switching of a large load, or energizing a capacitor bank). B. Voltage Sags Voltage sag is a short-duration (typically,5 to cycles) reduction in the rms voltage caused by faults on the power system (short circuits) and the starting of large loads, such as motors. Momentary interruptions (typically no more than to 5s) cause a complete loss of voltage and are a common result of the actions taken by utilities to clear transient faults on their systems. C. Frequency variations Frequency variations are defined as the deviation of the power system fundamental frequency from its specified nominal value (5Hz in our case). Frequency variations that go outside of accepted limits for normal steady-state operation of the power system can be caused by faults on the bulk power transmission system, a large block of load being disconnected, or a large source of generation going off-line. D. Voltage fluctuations - Flicker Voltage fluctuations are systematic variations of the voltage envelope or a series of random voltage changes. Loads, which exhibit continuous, rapid variations in the load current magnitude, can cause voltage variations that are often referred to as flicker. The term flicker is derived from the impact of voltage fluctuation on lamps such that they are perceived to flicker by the human eye. To be technically correct, voltage fluctuation is an electromagnetic phenomenon while flicker is an undesirable result in some loads. https://doi.org/.484/repqj.7 7 RE&PQJ, Vol., No., April

E. Harmonic distortion Harmonic distortion is a deformation of a voltage or current sinusoidal wave. A harmonic signal can be defined as a sinusoidal signal whose frequency is multiple of the fundamental frequency. Distorted waveforms can be decomposed into a sum of the fundamental frequency and the harmonics. Harmonic distortion originates in the non-linear characteristics of devices and loads on the power system. this example the harmonic frequency is three times the basic frequency. F. Noise Noise is defined as unwanted electrical signals with broadband spectral content lower than khz, superimposed upon the power system voltage or current in phase conductors, or found on neutral conductors or signal lines. Noise in power systems can be caused by power electronic devices, control circuits, arcing equipment, loads with solid-state rectifiers, and switching power supplies.. Harmonics definitions and related parameters It is, especially the sinusoidal voltage waveform that is necessary to keep since the production until the final receivers, passing thought the distribution, with the purpose to preserve its essential characteristics for the transmission of useful power to the terminal equipments. Fig. Example of a distorted signal According to French mathematician Joseph Fourier, any periodic signal, can be decomposed in an sum of pure sine waves in which the frequency of each sinusoid is an integer multiple of the fundamental frequency of the distorted wave. () The electric grid comes being target not linear load constant. This evolution in the characteristic of loads however allowed improvements in the quality of modern life, this type of loads, at the same time that they pollute the electric grid, generating a lot of impure signals and harmonics, they are well more sensible to the effect created by these distortions. When the voltage and current waveforms leaves of being sinusoidal, the disturbances appear, that affect numerous utility equipments, originating equipment failures. The distorted loads, produces in the power system distorted currents. Distorted currents from harmonicproducing loads also distorted the voltage as they pass trough the system impedance. Thus a distorted voltage is present to other end users. Therefore, while it is the voltage with which we are ultimately concerned, we must address phenomena in the current to understand the basis of many power quality problems. A. Harmonic definitions According to EN 56, a harmonic voltage is a sinusoidal signal whose frequency is multiple of the basic voltage frequency. The voltage or current waveforms in one point of the electric system can have the aspect of the figure distorted signal. Analysing the signals in this figure we can say that the distorted signal is the result of the addition of the harmonic with the basic component. In Where Y represents the DC component amplitude that in steady state is normally null. The Y n parameter represents the rms value of the order n harmonic, while ϕ n represents the harmonic angle phase for t =. Therefore, we can define the harmonics as being sinusoidal oscillations whose frequency is multiple of the fundamental frequency. B. Harmonic order Harmonics are classified by three parameters: its order, the frequency and the sequence, in accordance with table. TABLE Harmonics classification Order 4... n Freq.(Hz) 5 5... n*5 Seq. + - +...... The harmonic number (order) represents the number of times that the frequency of this harmonic is bigger than the basic component (equation ). f harmonic order = () f fundamental https://doi.org/.484/repqj.7 8 RE&PQJ, Vol., No., April

By table it can be said that two harmonics types exist, odd and the pairs. The odd harmonics are the ones that are find in the electric installations, industrial and commercial buildings, while the harmonics of pair order only appear when asymmetry in the signal due to continuous component exists. C. Total harmonic distortion (THD) There are several measures commonly used for indicating the harmonic content of a waveform with a single number. One of the most common is total harmonic distortion (THD). Two equations exist to calculate the THD. ( h ) + ( h ) +...( h ) THD = % () f h ( h ) + ( h ) +...( hn ) ( h ) + ( h ) + ( h ) +...( h ) THD = % (4) r Where h, h,..., h n represents the harmonics rms value for order,,..., n. THD r represents the total harmonic distortion relatively to the total signal, in this case, <THD r <, while THD f represents the total harmonic distortion relatively to the fundamental component, this definition is used by IEC 6--, in this case values above % are possible to the THD f. 4. Harmonic effects and consequences The harmonic distortion is caused by nonlinear devices in the power system, like electronics systems, personals computers and fluorescent lamps, also helps in the increment of the amount of harmonics in an installation. A. Harmonic effects Heating of the conductors and other devices: The heating is one of the most important effect associated to the harmonics, being able to happen especially in the machines (motors, alternators, transformers) windings, and in the neutral conductor of an installation. Protection devices switching: Signals with harmonics can have low current rms value and reach very high peak values. This fact takes protection devices to switchs off. Resonance: Capacitors in parallel with an inductor form a resonant circuit, able to amplify some signals. When in a power system we place a capacitor bank that forms a resonant circuit, since the capacitor bank is placed in parallel with the electric grid that is predominantly inductive. This fact takes that some harmonics can be amplified, arriving in certain cases to destroy the capacitor bank. n n Vibrations and couplings: The high frequencies contained in the harmonics, provoke electromagnetic interferences that can be radiated or conducted. The electromagnetic interferences can provoke vibrations in the electrical equipment and couplings in the communication networks. In the last case, this noise can provoke errors in the information transmitted. Deterioration in the voltage waveform: When a power system has a great harmonic content, the current distortion provoked for non-linear loads leads to a deformation in the voltage waveform resulting in a flatness in the upper/lower part of this, as it can be seen in the figures presented in the following chapter. B. Harmonic consequences Conductors: The conductor s impedance depends on the frequency. The electrical grids are projected to work with one frequency (5 Hz in our case), when the frequency increases; the conductor s impedance also increases (skin effect). As consequence a superheating of the conductors is verified originating the insulation destruction and provoking short circuits and fires. Computers and informatics loads: The computers are the elements that more harmonics produce and in simultaneous most sensible are to them. The harmonics components in an installation that feeds computers and informatics systems can be of such high form that they lead to the hard disks destruction, sporadically loss of data and resets. Capacitors: The capacitors impedance fall with the frequency, therefore, how much bigger it is, the biggest will be the possibilities to appear parasitic currents. Overloads can exist whose consequence is the capacitors destruction. Transformers: The effect in the transformers is diverse. On the other hand, as already it was said, it will have windings superheating, and at the same time, the impedance source increase due to the harmonics, provoking an increase in the transformer losses. 5. Active harmonic conditioners Similar to solve of an efficient and definitive form the problems created by the harmonics, equipment called for active compensators of harmonics exists in the market. The concept of active harmonic conditioner, also calls active filters exists since some decades, however due to lack of adequate technology its development was limited. Figure shows the basic principle of the shunt-type active harmonic conditioner. Provided that the device is able to inject at any time a current where each harmonic current has the same amplitude as that of the current in the load and is in opposition of phases, then Kirchoff s law at point A guarantees that the current supplied by the source is purely sinusoidal. The combination of non-linear loads + active harmonic conditioner forms a linear load (in https://doi.org/.484/repqj.7 9 RE&PQJ, Vol., No., April

which current and voltage are linked by a factor k). This kind of device is particularly suited for harmonic compensation of LV networks irrespective of the chosen point of coupling and of the type of load (the device is self-adaptive). some of which had been filtered, with active harmonic conditioners. It can verify the voltages and currents waveforms as well as the voltage harmonic spectrum in one of the phases and the total harmonic distortion in different situations. In figure the results gotten in a machinery laboratory without active harmonic conditioner are presented while in Figure 4 we can see the same signals with active harmonic conditioner. Volts 4 Amps - - - - - -4-6:7:5,7 6:7:5,75 6:7:5,8 6:7:5,85 6:7:5,9 6:7:5,95 CHA Volts CHB Volts CHC Volts CHA Amps CHB Amps CHC Amps Fig. Principle of compensation of harmonic components by shunt type active harmonic conditioner % of FND 6 CI THD Norm to Hi at 9-4- 6:7:5, (a) 5 The following functions are thus performed according to the level of insertion: -Local harmonics compensation: if the active harmonic conditioner is associated with a single non-linear load, -Global harmonics compensation: if the connection is made (for example) in the MLVS (Main Low Voltage Switchboard) of the installation. The shunt-type active harmonic conditioner thus forms a current source independent of power network impedance, and with the following intrinsic characteristics: -its band-width is sufficient to guarantee removal of most harmonic components (in statistical terms) from the load current. We normally consider the range H - H to be satisfactory, as the higher the order, the lower the harmonic level. -its response time is such that harmonic compensation is effective not only in steady state but also in slow transient state (a few dozen ms), -its power enables the set harmonic compensation objectives to be met. However this does not necessarily mean total, permanent compensation of the harmonics generated by the loads. Provided that these three objectives are simultaneously achieved, the shunt-type active harmonic conditioner forms an excellent solution as it is self-adaptive and there is no risk of interaction with power network impedance. [5] 6. Experimental results 4 Thd H5 H H5 H CHA Volts % 9 8 7 6 5 4 Total RMS: 5. Volts DC Level : -. Volts Fundamental(H) RMS: 4.8 Volts Total Harmonic Distortion (H-H5): 5.97 % of FND Even contribution (H-H5):.7 % of FND Odd contribution (H-H49): 5.97 % of FND BI THD Hi to Norm at 9-4- :7:, (b) : :4 : : :4 : : :4 4: 4: CHA Ithd 9-4- ::, - 9-4- 4::, (c) Fig. Monitorizations doing at a Machinery Lab without active harmonic conditioner. (a) Currents and voltages waveforms. (b) Harmonic spectrum of voltage at phase A. (c) Total harmonic distortion variation (I THD ) I THD Average=5%. In this chapter some monitorizations results doing in different types of electrical installations are presented, https://doi.org/.484/repqj.7 RE&PQJ, Vol., No., April

Timed event at -6- :47:5, 4 Volts Amps Amps 75 5 5 5 5 - -5-5 - -5 - - -75-5 -4 - :47:5, :47:5,5 :47:5, :47:5,5 :47:5, CHA Volts Volts CHC Amps CHB Volts CHC CHA Amps CHB Amps - :7:9, :7:9,5 :7:9, :7:9,5 :7:9, CHA Amps CHB Amps CHC Amps Timed event at 8-5- :7:9, (a) (a) % of FND 4.5 Volts 4 4..5..5..5 -. -.5. Thd H5 H H5 H CHA Volts Total RMS:.7 Volts DC Level : -.9 Volts Fundamental(H) RMS:.5 Volts Total Harmonic Distortion (H-H5): 4.5 % of FND Even contribution (H-H5):.8 % of FND Odd contribution (H-H49): 4.5 % of FND Timed event at -6- :47:5, (b) - -4 :7:9, :7:9,5 :7:9, :7:9,5 :7:9, CHA Volts CHB Volts CHC Volts Timed event at 8-5- :7:9, % of FND 5 (b) % 8 7 75 6 5 5 5 4 Thd H5 H H5 H CHA Amps Total RMS:.7 Amps DC Level : -. Amps Fundamental(H) RMS:.49 Amps Total Harmonic Distortion (H-H5):.4 % of FND Even contribution (H-H5): 6.6 % of FND Odd contribution (H-H49):.4 % of FND : :4 : : :4 : : :4 4: 4: 4:4 5: CHA Ithd -6- ::, - -6-5::, (c) %.5 Timed event at 8-5- :57:9, (c) Fig.4 Monitorizations doing at a Machinery Lab with active harmonic conditioner. (a) Currents and voltages waveforms. (b) Harmonic spectrum of voltage at phase A. (c) Total harmonic distortion variation (I THD ) I THD Average=,5%.. 7.5 5..5. Figure 5 shows the results gotten in a informatics laboratory with about 5 computers, without active harmonics conditioner. In that kind of installations the currents waveforms are pulsed due to the switching supply. 97.5 95. : : :4 : : :4 4: 4: 4:4 5: 5: CHA Ithd CHB Ithd CHC Ithd 8-5- ::, - 8-5- 5::, (d) Fig.5 Monitorizations doing at a Informatics Lab without active harmonic conditioner. (a) Currents and (b) voltages waveforms. (c) Harmonic spectrum of voltage at phase A. (d) Total harmonic distortion variation (I THD ) I THD Average=5%. https://doi.org/.484/repqj.7 RE&PQJ, Vol., No., April

7. Conclusions After detailed analysis and monitorization of electric installations supplying different types of loads we conclude that the waveform signals of voltage and current are very different. As consequence, the involved total harmonic distortion (THD) in the different installations types are also very different, being able to reach values above % for ITHD in the case of installations supplying informatics equipment. As solution to minimize this kind of problems the active harmonics conditioner also called active harmonic filters are used. The performance of this equipment is sufficiently good, taking a remarkable decrease in the total harmonic distortion and a good improvement in the power system quality. Acknowledgement The authors are gratefully to Ing. Armínio Teixeira of FEUP for is cooperation and given facilities. We are also in great debt to Ing. Augusto Vaz and Simões Alves of Labelec (EDP group). References [] R. Dugan, Mark McGranaghan, H. Beaty, Electrical Power Systems Quality, Mc Graw Hill [] Gregory Porter, J. Andrew Van Sciver, Power Quality Solutions, Prentice Hall [] Ángel Pérez Miguel, Nicolás de Medina, Manuel Antón, La Amenaza de los Armónicos y sus Soluciones Paraninfo [4] Éric Félice, Perturbaciones Armónicas Paraninfo [5] E. Bettega, J. N. Fiorina, Active harmonic conditioners and unity power factors rectifiers, Cahier technique Nº 8 Schneider electric https://doi.org/.484/repqj.7 RE&PQJ, Vol., No., April