TIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES

Similar documents
Diffraction Gratings for the Selection of Ultrashort Pulses in the Extreme-Ultraviolet

On-line spectrometer for FEL radiation at

Photon Diagnostics. FLASH User Workshop 08.

Outline of the proposed JLAMP VUV/soft X-ray FEL and the challenges for the photon beamlines and optics

High-Energy 6.2-fs Pulses for Attosecond Pulse Generation

NIST EUVL Metrology Programs

High Energy Non - Collinear OPA

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

High Power and Energy Femtosecond Lasers

Romania and High Power Lasers Towards Extreme Light Infrastructure in Romania

Spectral Phase Modulation and chirped pulse amplification in High Gain Harmonic Generation

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

FA Noncollinear Optical Parametric Amplifier

Fiber Lasers for EUV Lithography

Progress of the TEO experiment at FLASH

J-KAREN-P Session 1, 10:00 10:

How to build an Er:fiber femtosecond laser

Performance of the SASE3 monochromator equipped with a provisional short grating. Variable line spacing grating specifications

Case Study: Simplifying Access to High Energy sub-5-fs Pulses

Laser systems for science instruments

FLASH II. FLASH II: a second undulator line and future test bed for FEL development.

taccor Optional features Overview Turn-key GHz femtosecond laser

High-Power Femtosecond Lasers

TriVista. Universal Raman Solution

Laser Science and Technology at LLE

Supplementary Information for

Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1

Spider Pulse Characterization

VELA PHOTOINJECTOR LASER. E.W. Snedden, Lasers and Diagnostics Group

Vacuum Ultra Violet Monochromator

Nonlinear Optics (WiSe 2015/16) Lecture 9: December 11, 2015

Application Note (A11)

Compression methods for XUV attosecond pulses

A novel High Average Power High Brightness Soft X-ray Source using a Thin Disk Laser System for optimized Laser Produced Plasma Generation

Sub-300 fs, 0.5 mj pulse at 1kHz from Ho:YLF amplifier and Kagome pulse compression

SCS Optical Laser Delivery

Wisconsin FEL Initiative

PGx11 series. Transform Limited Broadly Tunable Picosecond OPA APPLICATIONS. Available models

Powerful Single-Frequency Laser System based on a Cu-laser pumped Dye Laser

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

Water-Window Microscope Based on Nitrogen Plasma Capillary Discharge Source

Ultrafast instrumentation (No Alignment!)

A transportable optical frequency comb based on a mode-locked fibre laser

VUV-FEL User workshop, August 23-24, 2004

Bridging the Gap Between Tools & Applications

Carrier envelope phase effects on polarization gated attosecond spectra

Guide to SPEX Optical Spectrometer

Dispersion and Ultrashort Pulses II

Infrared Single Shot Diagnostics for the Longitudinal. Profile of the Electron Bunches at FLASH. Disputation

Beam Shaping in High-Power Laser Systems with Using Refractive Beam Shapers

Polarization effects in two-photon nonresonant ionization of argon with extremeultraviolet and infrared femtosecond pulses

EQUATION CHAPTER 1 SECTION 1 TOWARDS INTENSE SINGLE ATTOSECOND PULSE GENERATION FROM A 400 NM DRIVING LASER YAN CHENG

Fundamental Optics ULTRAFAST THEORY ( ) = ( ) ( q) FUNDAMENTAL OPTICS. q q = ( A150 Ultrafast Theory

Vitara. Automated, Hands-Free Ultrashort Pulse Ti:Sapphire Oscillator Family. Superior Reliability & Performance. Vitara Features:

Theoretical Approach. Why do we need ultra short technology?? INTRODUCTION:

k λ NA Resolution of optical systems depends on the wavelength visible light λ = 500 nm Extreme ultra-violet and soft x-ray light λ = 1-50 nm

Development of scalable laser technology for EUVL applications

Low aberration monolithic diffraction gratings for high performance optical spectrometers

Working in Visible NHMFL

High Rep-Rate KrF Laser Development and Intense Pulse Interaction Experiments for IFE*

A novel tunable diode laser using volume holographic gratings

Observational Astronomy

ASE Suppression in a Diode-Pumped Nd:YLF Regenerative Amplifier Using a Volume Bragg Grating

SPECIAL EXCIMER LASERS

A CW seeded femtosecond optical parametric amplifier

arxiv:physics/ v1 [physics.acc-ph] 18 Jul 2003

Powerful DMD-based light sources with a high throughput virtual slit Arsen R. Hajian* a, Ed Gooding a, Thomas Gunn a, Steven Bradbury a

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

Improving efficiency of CO 2

Continuum White Light Generation. WhiteLase: High Power Ultrabroadband

Optical Parametrical Chirped Pulse Amplification

TECHNIQUES FOR PUMP-PROBE SYNCHRONISATION OF FSEC RADIATION PULSES

BEAM DIAGNOSTICS AT THE VUV-FEL FACILITY

Doppler-free Fourier transform spectroscopy

Development of Ultrashort Pulsed VUV Laser and its Applications

Bioimaging of cells and tissues using accelerator-based sources

combustion diagnostics

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

Basic Components of Spectroscopic. Instrumentation

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

THz meets X-rays: Matthias C. Hoffmann, LCLS Laser Science & Technology Division SLAC National Accelerator Laboratory, Menlo Park, CA, 94025

RF-based Synchronization of the Seed and Pump-Probe Lasers to the Optical Synchronization System at FLASH

FLASH at DESY. FLASH. Free-Electron Laser in Hamburg. The first soft X-ray FEL operating two undulator beamlines simultaneously

SIMPLIFIED SCHEME FOR UV TIME PULSE SHAPING. Abstract

Directly Chirped Laser Source for Chirped Pulse Amplification

NDFG Non-collinear difference frequency generator

Historical. McPherson 15 Mount

Pulse Shaping Application Note

G. Norris* & G. McConnell

Adaptive Optics for. High Peak Power Lasers

In-focus monochromator: theory and experiment of a new grazing incidence mounting

New generation Laser amplifier system for FEL applications at DESY.

Ultrafast Surface-Enhanced Raman Probing of the Role of Hot Electrons in Plasmon-Driven Chemistry. Supporting Information

Light Sources for High Volume Metrology and Inspection Applications

Chemistry Instrumental Analysis Lecture 7. Chem 4631

Frequency modulation of high-order harmonic fields with synthesis of two-color laser fields

Simulation of Grating-Compressor Misalignment Tolerances and Mitigation Strategies

pulsecheck The Modular Autocorrelator

Optimization of supercontinuum generation in photonic crystal fibers for pulse compression

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

Transcription:

TIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES Luca Poletto CNR - Institute of Photonics and Nanotechnologies Laboratory for UV and X-Ray Optical Research Padova, Italy e-mail: poletto@dei.unipd.it

Background: high-order harmonics generation 1.00 30 fs laser pulse 0.75 0.50 0.25 0.00 1.00 sub-10 fs laser pulse 0.75 0.50 0.25 0.00 5 10 15 20 25 30 35 wavelength (nm) HH spectra in Helium, 300 J laser pulse

Outline HANDLING AND SPECTRAL SELECTION OF ULTRASHORT PULSES THE OFF-PLANE CONFIGURATION REALIZATION OF TIME-PRESERVING MONOCHROMATORS

High-order harmonics selection Let us consider the problem of the extraction of a single harmonic within a broad spectrum to obtain an ultrafast XUV monochromatic pulse EUV TUNABLE MONOCHROMATOR FOR HHs THE MONOCHROMATOR HAS TO PRESERVE THE TEMPORAL DURATION OF THE EUV PULSE AS SHORT AS IN THE GENERATION PROCESS This is crucial in order to have both HIGH TEMPORAL RESOLUTION and HIGH PEAK POWER THE PROBLEM OF TIME PRESERVATION IS SIMILAR IN CASE OF THE SPECTRAL SELECTION OF FREE-ELECTRON-LASER PULSES

Femtosecond pulses The time broadening of the pulse may be forced by a FILTERING OF ITS SPECTRUM operated by the optics FOURIER LIMIT FWHM 2 FWHM 1.5 10 3 Wavelength in nm Time in fs If the whole bandwidth of a single harmonics is selected, the spectral extension is maintained. The same case applies to a FEL in case of a low-resolution monochromator used as a spectral filter (e.g. suppression of the background or selection of the FEL harmonics)

Single-grating monochromator The wavelength selection is operated by a diffraction grating. The optical path of a ray differs from that of the neighbor by the quantity OP = m, where m is the diffraction order. The total difference, between the path on first to last groove is OP Nm Es: 5-mm FWHM beam, =30 nm (41 ev), 300 gr/mm grating, normal incidence 1500 illuminated grooves path-difference OP FWHM = 45 m, t FWHM = 150 fs

Limit of the grating monochromator For a given resolution, the minimum number of illuminated grooves (first diffracted order) is N = (Rayleigh criterion). This gives a broadening on the focus that is equal to the Fourier limit. FWHM 2 FWHM 1.7 10 3 If the number of grooves that are illuminated is the minimum for a given resolution, the broadening given by a diffraction grating is comparable to the Fourier limit. OPERATION AT GRAZING INCIDENCE! When working with gratings at grazing incidence, the illuminated area is long and the number of illuminated grooves is normally far superior to the Rayleigh limit. The problem of time preservation has to be analyzed!

Design of single-grating monochromators Aim of the design is to keep the number of illuminated grooves as close as possible to the resolution / For a grating used in the classical diffraction scheme, the effective groove density as seen by the beam is increased by the factor 1/cos E.g., for = 85, 1/cos 11 The groove density and the corresponding blaze profile that are required to maintain very low temporal broadening (few to several tens of femtoseconds) is unfeasible The classical diffraction scheme can be used to make the spectral selection with a single grating The temporal broadening is in the range 100-200 fs FWHM for technically feasible monochromators The efficiency is limited by the quality of the grating surface ( 20%)

Double-grating design Scheme for path length equalization: the mechanism which originates the path difference must be canceled. equalization of path length for diverse spectral components combination of two diffractive elements in negative dispersion correction of the optical aberrations DRAWBACKS OF THE DOUBLE-GRATING DESIGN LOW EFFICIENCY (two gratings) DESIGN NOT SUITABLE FOR BROAD-BAND MONOCHROMATORS AT GRAZING INCIDENCE P. Villoresi, Appl. Opt. 38, 6040 (1999)

Conclusions: spectral selection of ultrashort pulses The spectral selection of XUV ultrashort pulses made by diffraction gratings may introduce a severe temporal broadening Single-grating monochromators with 100 fs resolution are used in HH beamlines Time-preserving configurations have to be realized with double-grating designs: difficult at grazing incidence

Outline HANDLING AND SPECTRAL SELECTION OF ULTRASHORT PULSES THE OFF-PLANE CONFIGURATION REALIZATION OF TIME-PRESERVING MONOCHROMATORS

The off-plane mount OFF-PLANE MOUNT the incident and diffracted wave vectors are almost parallel to the grooves

Monocromators in the off-plane mount Entrance slit Plane mirror Entrance slit Paraboloidal mirror Plane mirror Plane grating Plane grating Paraboloidal mirror Exit slit Paraboloidal mirror Paraboloidal mirror Exit slit W. Werner and H. Visser, Appl. Opt. 20, 487 (1981)

diffraction efficiency diffraction efficiency Efficiency of gratings for XUV monochromators 0.8 0.6 0.4 0.2 Grating #1 I-st order, experiment I-st order, simulation 0-th order, experiment 0-th order, simulation 2-nd order, experiment 2-nd order, simulation 0.6 0.4 0.2 Grating #2 0.0 30 40 50 60 70 80 90 wavelength (nm) 0.0 20 40 60 80 wavelength (nm) 0.6 Grating #3 Grating gr/mm blaze angle altitude angle blaze wavelength Wavelength 0.4 region 1 400 9.7 3 44 nm 20-90 nm 2 400 4.5 5.6 38 nm 20-90 nm 0.2 3 600 7 3 21 nm 10-45 nm 0.0 10 20 30 40 wavelength (nm) M. Pascolini et al, Appl. Opt. 45, 3253 (2006)

Classical design vs off-plane Wavelength 30 nm Beam size 1 mm half-width The off-plane mount should be used for time responses in the 10-100 fs range. The classical mount is suitable for time responses in the 100-200 fs range.

Single-grating monochromators in the off-plane mount The groove density that is required to maintain very low temporal broadening is feasible with high efficiency =30 nm (41 ev), resolution 2%, 2 mrad FWHM divergence Monochromator parameters: p = 300 mm, = 4 Grating: 200 gr/mm, = 2.5 Time duration at the output: 12 fs FWHM Grating blaze angle: 2.5 High efficiency is expected

Conclusions: the off-plane design The off-plane mount gives generally higher efficiency than the classical mount Single-grating monochromators with very low temporal broadening and high efficiency can be designed Double-grating grazing-incidence designs can be used L. Poletto, P. Villoresi, F. Frassetto, Diffraction gratings for the selection of ultrashort pulses in the extreme-ultraviolet, in Advances in Solid-State Lasers: Development and Applications, M. Grishin ed., INTECH (Croazia), http://sciyo.com/books/show/title/advancesin-solid-state-lasers-development-and-applications (2010)

Outline HANDLING AND SPECTRAL SELECTION OF ULTRASHORT PULSES OFF-PLANE CONFIGURATION REALIZATION OF TIME-PRESERVING MONOCHROMATORS

Case 1: single-grating monochromator Toroidal mirror to collimate the light from the entrance slit Plane grating in the off-plane mount Toroidal mirror to focus the light on the exit slit Grating rotation to perform the spectral selection

The ARTEMIS facility @Rutherford Lab (UK) Three femtosecond synchronised laser beams 1. 14 mj, 30 fs, 1-3 khz CEPstabilised 2. <10fs 800nm pulses 3. 30 fs, tuneable UV to mid-ir Two femtosecond XUV beamlines 1. Broadband 10-100 ev XUV 2. Monochromatic short pulse (10-50 fs) OPA Tuneable UV to mid-ir CEP-stabilised Ti:Sapphire CPA system 14 mj, 30 fs, khz CEP D e l a y XUV generation XUV monochromator 10-100 ev XUV Science Stations Hollow fibre <10 fs CEP stable, 0.8 m Courtesy by E. Springate and E. Turcu (RAL)

Facility Layout Red Dragon laser XUV Monochromator Hollow fibre compressor OPA HE-Topas tuneable laser XUV generation Broadband HHG XUV Monochromatic XUV Slide with 4 gratings AMO Station Materials Science Station

The XUV monochromator of ARTEMIS Tunable in the 12 ev-100 ev range Four plane gratings in the off-plane mount Low resolution gratings: pulse duration ~10 fs High resolution gratings: pulse duration ~50 fs High efficiency: 25% peak efficiency measured Exit slit Toroidal mirrors HH source Ti:Sa laser Gratings Laser-jet interaction F. Frassetto et al, SPIE Proc. Vol. 7077, 707713 (2008)

Pictures

XUV Beamline: fsec Resolution 30fs, IR- Laser splitter Gas Jet: HHG Delay stage (a) 30fs, IR Laser beam (c) 30fs XUV monochromatic beam (b) 30fs XUV+IR focused on Kr atoms in ToF spectrometer (a) <0.6fs Resolution Interferometer XUV + IR XUV-Pump + IR-Probe: Kr 2+ ion yield function of temporal delay XUV vs. IR (b) XUV pulse duration measured ~ 30fs: XUV H23 (E=35.7eV) + IR (E=1.55eV). Courtesy by E. Turcu (RAL) and W. Bryan (Swansea Univ., UK)

Case 2: double-grating monochromator (1) DOUBLE-GRATING CONFIGURATION The two gratings are mounted in COMPENSATED CONFIGURATION and SUBTRACTIVE DISPERSION. Time compensation 1) the differences in the path lengths of rays with the same wavelength that are caused by the first grating are compensated by the second grating 2) rays with different wavelengths within the spectrum of the pulse to be selected are focused on the same point Focusing The focusing is provided by the toroidal mirrors Spectral selection A slit placed on the intermediate focus carries out the spectral selection of the HHs Wavelength scanning The wavelength scanning is performed by rotating the gratings around an axis tangent to the surface and parallel to the grooves

Case 2: double-grating monochromator (2) HHs source Plane grating 1 Toroidal mirror 1 Toroidal mirror 2 Intermediate slit Toroidal mirror 3 Toroidal mirror 4 Plane grating 2 Output focal point L. Poletto, Appl. Phys. B 78, 1013 (2004) L. Poletto and P. Villoresi, Appl. Opt. 45, 8577 (2006) L. Poletto, Appl. Opt. 48, 4526 (2009)

The monochromator for the HH experiment in Milano Monochromator chamber Generation chamber 20-60 nm tunability Toroidal mirrors Intermediate slit Toroidal mirrors HH source Ti:Sa laser Grating 2 Grating 1 Valve for gas injection L. Poletto et al, CLEO 2006

Image performance, wavelength calibration, efficiency

Temporal characterization Focus of IR pump pulse - HHs source Toroidal mirror 1 Plane grating 1 Toroidal mirror 2 Slit Plane grating 2 Toroidal mirror 3 XUV-IR combination mirror IR dressing pulse - varied delay with pump pulse Toroidal mirror 4 XUV focus - Ar gas jet Time-of-flight spectrometer XUV Absolute photodiode The temporal characterization is achieved by cross-correlation measurement of the XUV pulses with a synchronized 25-fs, 800-nm pulse at 1-kHz repetition rate. The harmonic pulse ionizes a gas in the presence of the IR field. When the two pulses overlap in time and space on a gas jet, sidebands appear in the photoelectron spectrum. The sideband amplitude as a function of the delay between the XUV and IR pulses provides the cross-correlation signal. L. Poletto et al, Opt. Lett. 32, 2897 (2007) L. Poletto et al, Rev. Sci. Inst. 80, 123109 (2009)

Trade-off in time preservation Single grating design Increase of the pulse duration ( 20-50 fs range) Maximum throughput for a grating monochromator (>30% in the offplane mount) Simple optical design Double grating design Preservation of the pulse duration in the few-fs range Lower throughput because of the two gratings (15-20%) More complex optical design

Conclusions: time-preserving monochromator Time-preserving monochromators for ultrashort pulses ( few tens of femtoseconds) with gratings in the off-plane mount have been realized The spectral selection of HHs is performed within a broad spectral interval Single-grating configuration: residual temporal broadening Double-grating configuration: preservation of the pulse duration Off-plane design can be applied also to beamlines for free-electronlaser radiation High efficiency Low temporal broadening Classical diffraction design is suitable for responses in the 100-200 fs time scale

People involved at LUXOR Dr. Fabio Frassetto Dr. Stefano Coraggia Prof. Paolo Villoresi Dr. Luca Poletto CNR - Institute of Photonics and Nanotechnologies LUXOR - Laboratory for UV and X-Ray Optical Research Padova, Italy Contact person: poletto@dei.unipd.it