SNOE 200 SNR bearing housings

Similar documents
Maintenance Information

DODGE Grease Lubricated SPLIT-SPHER Roller Bearings and Pillow Blocks

400 SERIES GRINDER PUMPS 41502, 42202,43302, AND MODELS

General Four-Way Operation, Maintenance & Service Manual

The Virgo/Libra Steam Engine

PEDESTAL OVERHAUL. Some of the tools for a pedestal overhaul. Pedestal work stand

1. TABLE OF CONTENT 2. ASSEMBLY ATEX. PENCOflex Installation Instructions & Service Manual

REPAIR INSTRUCTIONS. Cat. No Cat. No MILWAUKEE ELECTRIC TOOL CORPORATION. SDS Max Demolition Hammer. SDS Max Rotary Hammer

Trunnion bearing housings for grinding mills FSDR.. K series

DRIVE COMPONENTS REMOVAL. 9. FXCW/C: see Figure Remove bolt (9), sprocket retainer (8), and thrust washer (7). NOTE PRIMARY DRIVE LOCKING TOOL

AFB (AIR FAN BEARING) INSTALLATION GUIDE

Repair Manual MWS45A-MWS50A-MWS55A MW32A-MWS36A-MWS40A. Ref Rev.D General Pump is a member of the Interpump Group

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL

LORON SERVICE MANUAL / PARTS LIST SINGLE DOUBLE PALLET HANDLER CONTENTS: PAGE 1 Lift Truck Requirements General Installation Procedures

ELECTRIC TOOL CORPORATION

Instruction Manual for DODGE SLEEVOIL RXT Pillow Blocks With External Circulating Oil Lubrication

Instructions for Installation, Operation, Maintenance and Inspection. Slide Bearing Type ZM RH - ZMN - E 07.02

Check valve type RK and RB

OPERATION AND MAINTENANCE FOR MODEL MRV050A REVERSIBLE

KBS 40 Locking Device is a frictionally engaged detachable shaft-hub connection for cylindrical shafts and bores without keyway.

YALE FIGURE 500 & 500R CLOSURE OPERATION AND MAINTENANCE INSTRUCTIONS

PO STYLE AIR CLUTCH INSTALLATION AND MAINTENANCE MANUAL

Orbital Test Stand. Operations and Assembly Manual. Department of Mechanical Engineering Northern Arizona University Flagstaff, AZ 86011

DO35 MAINTENANCE INSTRUCTIONS

Technical Manual. ETP-CLASSIC incl type R. Content

Instruction Manual for DODGE SLEEVOIL RXT Pillow Blocks With Self Lubrication (oil ring)

Click Here to Go Back

INSTRUCTIONS FOR AIRFLEX 36WCBEP/36WCSEP WEAR PLATE REPLACEMENT USING GASKET SEALING TAPE

Mechanical Technical Assistance Manual for washers

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections

caroma marc newson shower mixer

w w w. h d o n l i n e s h o p. d e TIMKEN BEARING CONVERSION TOOL GENERAL INSTALLATION -J04672 REV Kit Number Models

WSG 8-115; 8-125; P; WSG ; WSG P; WSG PS; WSG P; WSG 15-70Inox

Inventory MODEL T10096 TAPER ATTACHMENT FOR G0509 & G0509G LATHE INSTRUCTIONS. Inventory (Figure 1) Needed Items

E.C. HOPKINS LTD PGO4 PEANUT GRINDER OPERATORS MANUAL AND PARTS LIST

MSR/MSB Mechanical Setting Tool

Maintenance & Parts list for:

FBX1104P FBX1104 FBX1106P FBX1106

Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard

Installation Instructions

OPERATION AND MAINTENANCE INSTRUCTIONS AVK UNDERGROUND FIRE HYDRANT

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections

Repair Instructions. Durametallic PSS III. Experience In Motion. Split Seal

Pow-R-Feed Systems Service Manual

HBS-AP ASSEMBLING INSTRUCTIONS

LK36-LK40-LK45 LK50-LK55-LK60

I E D DIN EN ISO 9001 I T Y S Y S T E M. Reg. Nr

JARVIS. Model Brisket Scissor EQUIPMENT... TABLE OF

How to operate (folding)

OPERATING INSTRUCTIONS MODULGRAV. Tel. +49 (0) Fax +49 (0) homepage:

Hydraulic Clamp Carrier. Installation & Operation Manual

Type XTSR71 Sizes

SERVICE PARTS LIST. M18 FUEL SAWZALL Reciprocating Saw F56A BULLETIN NO CATALOG NO

Threadlocking Adhesives

RIPPER PEDAL. Bearing / Axle Replacement. ( Disassembly )

H8508 Impact Wrench SERVICE MANUAL. Model (Serial Code FWN) Model (Serial Code FWP)

MSR/MSB Mechanical Setting Tool

Operating Manuel. High Speed Screw Jack G1-G3. Model N/V/R. NEFF-High Speed Screw Jacks G1-G3. Version N/V/R

Installation and Operational Instructions for ROBA -DS couplings Type 95. _ (disk pack HF) Sizes

KRW bearing solutions for rotary tables

Aircraft assembly and disassembly

Ringblaster Mark IV Maintenance Guide. Version 1.5

SETTING UP THE MODEL 210B-2 SRA

No September, Char-Lynn. Power Steering. Repair Information. 20 Series Steering Control Unit 001

Manual for the Feathering Propeller. DF blade model

Char-Lynn Hydraulic Motor. Repair Information. R Series General Purpose Geroler Motor November, 1996

Slide the stock rubber tank mount caps onto the ends of the CS-1 tank mount:

Airflex Product Line PDC Installation, Operation and Maintenance of PDC Assemblies

Table of Contents. B. Base Tool Changer...2 MC-16 Manual Tool Changer...2

HMZ Locknuts simple and reliable locking devices

COYOTE ENTERPRISES, INC. RIMLOC BLAST WHEEL MAINTENANCE & ASSEMBLY MANUAL

No November, Char-Lynn. Hydraulic Motor. Repair Information. R Series General Purpose Geroler Motor

3 Emergency Breakaway Coupling

GLUING SOLUTIONS EDGE BANDING HEAD INSTRUCTIONS MANUAL MA-5075-E

Mechanical Frappe Press

EURO-BEARINGS LTD COMBINED ROLLER BEARINGS & MATING STEEL PROFILES

INSTALLATION OF WELLS SUPER QUICK CHUCK LEFT HAND ON RED WING LATHE

CAUTION! This manual contains important information for the correct installation, operation and maintenance of the equipment described herein.

MODEL T26413, T26414, & T26415 ARBOR PRESS INSTRUCTIONS

Repair Manual 12 PL PILOT

Power Train Lift Max. Capacity: 1,250 lbs.

2. Stand mainframe upright and cut bungee cord tie strap.

Hydrajaws Safety Lifeline Tester

5000 Series Single Impeller Firefighter

4.2 - PUMP MAINTENANCE MODELS: AC, AS, WC, WS

Rev B C-RING TOOL VA0375 ½ in. OPERATING MANUAL

LINEAR MOTION Screw Jack Actuator Models

KRW bearing solutions for rotary tables

Lumber Smith. Assembly Manual. If you are having problems assembling the saw and need assistance, please contact us at:

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7

SAVE THIS FOR FUTURE REFERENCE THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL

Series B Medical Gas Service Outlet Upgrade Kits

Midwest RDH Handpiece Repair Procedure

GP-SD GENIE PROBE SMALL DIAMETER

PET*STAR 4 OPERATOR MANUAL

Chin Strap, Sealed Pull Pins and Swing Catch for Fiberglass Helmets. Contents

Submersible Turbine Assembly Manual

MODELS 49 RA 49 RAZ 49 RAC

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

Ensat driving tools...

Transcription:

Assembly, servicing and maintenance instructions SNOE 200 SNR bearing housings N TS5142 www.ntn-snr.com With You

Contents 1. Types of housing with oil-lubricated pillow block 2. Preparation for assembly 3. Mounting the shaft 4. Finalising 5. Disassembly 6. Commissioning 7. Lubrication 8. Servicing 9. Screws and bolts 10. Screws, threads and measurements 11. Appendix p.3 p.4 p.4 p.5 p.8 p.8 p.9 p. 11 p.12 p.13 p. 14 Pictograms Danger: this pictogram indicates hazards relating to the health of persons and damage to equipment. Instruction: this pictogram indicates advice on assembly and use for quick and efficient working. The objective being to obtain a perfect, secure bearing. 2

Assembly, servicing and maintenance instructions 1. Types of housing with oil-lubricated pillow block Single locking Dual opening 1. Upper part of housing 2. Outer side cover (in several parts) 3. Ventilation filter 4. Cover seal 5. Stop plate 6. Slotted round nut 7. Bearing 8. Grub screw 9. Labyrinth seal (outer) 10. Fixing bolt 11. Labyrinth seal (inner) 12. Greasing ring 13. Connecting bolt 14. Cover screw 15. Oil level indicator 16. Lower part of bearing hou-sing 17. Inner side cover (in several parts) 18. Guide pin 19. Fixing bolt (Oil drain hole) 20. Greaser 21. Closed inner cover 22. Open inner cover 23. Threaded ring 3

2. Preparation for assembly a) Before you start work, the work station or assembly area should be cleaned. Ensure that the tools used for assembly are clean. b) The housings must be completely dismantled. To do this, first remove the side covers (2 and 17), then the cover seals (4). Separate the upper and lower sections of the housing (1 and 16). IMPORTANT When re-assembling the housing, it is essential that it is done in the right order, so the parts should be numbered. c) Undo the fixing bolt (10) (which holds the cover (17) greasing ring (12) guide pin (18). d) The shaft, labyrinth seals, internal parts of the housing and the cover must be cleaned and de-greased. e) The bolts (10 and 19) and also the oil level indicator supplied with the housing (15) are fitted using copper sealing rings. Prior to each fitting, it should be checked that these copper seals are new. A copper seal can only be used once. 3. Mounting the shaft a) Put the shaft down horizontally and ensure that it cannot roll. Protect its surface to avoid damage. b) Slide the inner cover (17), flat seal (4) and greasing ring (12) on to the shaft. c) Heat the inner labyrinth seal (11) (the longer one) to approximately 90 C, using, for exam-ple, an SNR Fast Therm 20, Fast Therm 35 or Fast Therm 150 induction heater and thread it on to the shaft, applying pressure to the collet during the whole of its cooling time. 4

Assembly, servicing and maintenance instructions d) Using the same procedure, fit the fixed bearing on to the shaft (max. temperature 120 C). Pay attention to the fitting orientation ( the markings must be pointing towards the end of the shaft). Finally, also fit the stop plate (5) and slotted round nut (6) to lock the bearing (7) in the axial direction. e) Thread the outer labyrinth seal (9) on to the shaft as far as the slotted round nut (6). f) Lock the grub screws (8), using Loctite 222 screw locking compound or similar and tighten to the recommended torque (see Screws and bolts section). g) For fitting the floating bearing, refer to points b) to e). Finally, protect the assembly from contamination by placing a film over it, for example. sealing paste 4. Finalising a) Position the flat seals (4) in front of the two inner covers. b) Fit the previously assembled shaft into the lower part of the housing. c) Apply Marston sealing paste (see data sheet appended) or a similar product on the seals (see drawing above) between the upper and lower parts of the housing (1 and 16) and then assemble the two parts. Tighten the fixing bolts according to the information given in the Screws and bolts section. The screws must be tightened in a cross pattern, first 30% tight and then to the final torque. d) Place the greasing rings (12) on the inner labyrinth seals and push the guide pins (18) into the holes on the under side of the bearing housing base. 5

e) Apply Marston sealing paste or similar to both sides of the cover seals (4) and first screw the inner cover (17) into its locating points. IMPORTANT Allow evaporation time (manufacturer s data sheet, page 14) Tighten the cover screws as per the method and the following diagram: Level 1: 10% torque Level 2: 50% torque Level 3: 100% torque (For torque values, see the Screws and bolts section) Cover screw tightening order f) Protect the bearing (7) and the internal parts of the housing. Allow the product to dry for approximately ten minutes. g) Put a little clean oil in the bearing (7) and distribute it by rotating the shaft. h) Screw in the fixing bolt (10) for the cover (17) greasing ring (12) guide pin (18). i) Fit the outer covers (2) with the flat seals (4). Follow the procedure in point e). j) Ensure that all the openings in the housing, such as for example, the bores for the connection of temperature, vibration or other measurement devices are properly locked. 6

Assembly, servicing and maintenance instructions k) Fix the oil level indicator supplied with the housing (15) at one of the four connection points. Secure the oil level indicator thread in its housing with Loctite 222 thread locking compound or similar. Each time the assembly is taken apart, a new copper sealing ring should be fitted between the cage surfaces and the oil level indicator fixing points. IMPORTANT Copper sealing rings must only be used once and must be changed each time the assembly is taken apart. l) Align the housing with the support and screw in the four feet, following the recommenda-tions in the Screws and bolts section. The screws must be tightened in a cross pattern, first 30% tight and then to the final torque. Fix the housing with pins. Positioning and fitting the SNOE oil level indicator The oil level indicator must be disas-sembled for fitting. Fitting to the housing: 1. Screw the support with the stop plate (for right or left side mounting), the two locknuts and the copper ring into the housing, keeping the assembly vertical. (use screw locking compound). 2. Screw the brass tube, glass window, cap and seals into the support (ensure that the rubber seals are correctly positioned). Important: Ensure that the bleed valve is not covered by the cap or blocked, otherwise the indicator will not display the oil level correctly. * Two stop plates are supplied with the housing for right or left side mounting. 7

5. Disassembly a) Drain the assembly, for this you can use the fixing bolts (19). b) Undo the bolts and screws (13 and 14). c) Remove the upper part of the housing (1) and the covers (2 and 17). IMPORTANT Since flat seals (4) can disintegrate when removing the covers, it is recommended that they are changed. d) Remove the guide pin (18) and take out the greasing ring (12) from the labyrinth seal nut (11) on the shaft. e) Remove the shaft. f) Remove the stop plate (5) by lifting up the strip and unscrew the slotted round nut (6). g) Remove the bearing on a press or with an extractor, pressing on the inner ring. The extrac-tion force must not reach the outer ring, since this could damage the raceways or rolling bodies. h) Check to see whether the bearing has suffered any damage to the surfaces of the bearing seat, cam rollers or cage. 6. Commissioning Slowly pour oil through the ventilation filter opening (3) until the maximum mark on the gauge is reached. Then screw the filter back inside to prevent any contamination in the housing. The greases and the recommended quantities are given in the Lubrication section. Then make a test by manually rotating the shaft. Finally, turn the bearings, if possible reducing the speed of rotation by half. Check the oil level and add some more, if necessary. In service, the oil level must always be between the H max. and H min. marks,, on the oil level gauge. For the first few hours, check the temperature of the bearings. 8

Assembly, servicing and maintenance instructions 7. Lubrication The quantities of oil given in this table are for indication purposes only. The essential criterion is the level of oil during service. Housing reference Approx. oil quantity [l] Oil level in service [mm] H min. H max. SNOE214 1,4 50 65 SNOE217 1,4 50 65 SNOE218 1,5 45 60 SNOE219 1,6 55 70 SNOE220 1,7 55 65 SNOE222 2,1 50 70 SNOE224 2,3 50 70 SNOE226 2,3 55 75 SNOE228 3,7 55 70 SNOE230 4,2 65 90 SNOE232 4,7 60 80 SNOE234 II 5,2 90 105 SNOE236 II 5,2 75 110 SNOE238 II 6,5 70 100 SNOE240 II 6,3 75 98 SNOE244 II 8,2 80 110 SNOE248 II 10,0 100 125 SNOE252 II 12,0 118 143 Table 1 The quality and viscosity of the oil to be used depend on the temperature of the bearing, its load, the speed of rotation of the shaft and other external factors; approximate data are there-fore not possible. The viscosity of the oil may be defined in relation to the average diameter of the bearing and the speed of rotation. Diagram 1 shows the operating viscosity ν1. At the service temperature, the oil should at least have viscosity ν1. But the aim is to obtain an operating viscosity of ν = 2 ν1. The reference viscosity at a temperature of 40 C is the ISO viscosity class, which can be found in table 2. The oil viscosity to temperature graph shows the relationship for standard mineral oils. 9

Diagram 1 Viscosity ν 1 Diagram 2 Temperature/viscosity for mineral oils Viscosity [mm 2 /s] Operating temperature t [ C] Operating viscosity ν [mm 2 /s] 10

Assembly, servicing and maintenance instructions 8. Servicing At regular intervals, it should be checked that the bearing units are operating normally and at the right temperature. Unusual noises or temperatures are signs of a malfunction.. If possible, the cause should be determined immediately. An unbalanced load or insufficient greasing could, for example, alter the usual noise during operation. To monitor the condition of bearings, tapped holes placed laterally in the housing (M8, M10) allow devices to be installed that can record vibration (SPM for example). To measure the bear-ing s temperature (PT100 for example), the G1/4 or G1/2 tapped holes in the upper part of the body can be used. (see SCREWS AND BOLTS section) These devices allow signs of damage to be detected in time, and the right moment identified to change the bearing housing. The oil level should be checked regularly (at least once a month) and during operation, since the oil level is lower when the shaft is running. When adding oil during operation at full speed, the oil level should be approximately 5 mm below the maximum, so as to avoid over-filling. After two or three days of operation (50 to 70 hours approximately), it is recommended that the oil is drained and its lubrication qualities checked. The results of the analysis will enable oil change cycles to be determined. For cold air ventilation, an additional oil change is indicated after approximately 2000 hours of service, for warm air ventilation, approximately 1000 hours. The next changes should be decided on after analysis of the oil. The reference thresholds are approximately 5,000 hours for cold air ventilation and 2,000 hours for warm air ventilation. The manufacturer s recommendations should be followed. Re-greasing is necessary at regular intervals (according to the cycles); it is done via the greaser (Note: not suitable for felt seals). When re-greasing, a quantity of grease should be added, sufficient to make the sealing clearance overflow. Under normal conditions of use, for a bearing temperature up to approximately 100 C, a penetration class 3 lithium soap grease with a drop point of 180 C is perfectly suitable, for example Shell Alvania RL3 or Esso Beacon 3. It is important to check the permeability of the ventilation filter (3) regularly and replace it if necessary. 11

9. Screws and bolts Recommended tightening torques Fixing bolts Upper/lower parts Cover screw Guide pin Labyrinth seal (with nut lock compound) Recommended pillow block bolts Standard ISO 4014 ISO 4017 DIN 916 ISO 4014 Property class 8.8 8.8 8.8 8.8 No. (on the drawing) (n 13) (n 14) (n 8) - SNOE214 M10 35 Nm SNOE217 M10 35 Nm M20 260 Nm SNOE218 M10 35 Nm M20 260 Nm SNOE219 M10 35 Nm M24 440 Nm SNOE220 M20 260 Nm M24 440 Nm SNOE222 M20 260 Nm M30 870 Nm SNOE224 M20 260 Nm M30 870 Nm SNOE226 M20 260 Nm M30 870 Nm SNOE228 M20 260 Nm M30 870 Nm SNOE230 M24 440 Nm M36 1520 Nm SNOE232 M24 440 Nm M36 1520 Nm SNOE II 234 M24 440 Nm M8 12 Nm M36 1520 Nm SNOE II 236 M24 440 Nm M8 12 Nm M36 1520 Nm SNOE II 238 M30 870 Nm M42 2040 Nm SNOE II 240 M30 870 Nm M42 2040 Nm SNOE II 244 M36 1520 Nm M8 12 Nm M42 2040 Nm SNOE II 248 M36 1520 Nm M10 35 Nm M42 2040 Nm SNOE II 252 M36 1520 Nm M42 2040 Nm Table 2 12

Assembly, servicing and maintenance instructions 10.Screws, threads and measurements For any further information you may require, please contact us at the following address: SNR WÄLZLAGER GMBH - INDUSTRY ENGINEERING DIVISION BIELEFELD - Postfach 17 01 45 33701 Bielefeld Tél.: 05 21 924 00 0 Fax: 05 21 924 00 77 13

11. Appendix Data sheet MARSTON Colour: Density (at 25 C): Base material Solvent: Minimum thermal resistance: Maximum thermal resistance: Max. filling capacity: State when delivered Behaviour in respect of corrosion Preparation: Recommendation: Storage period: red 1.1 g/cm³ 63 to 67% polyurethane mixture of acetone and ethyl acetate 33 to 37% -50 C +270 C approx. 0.2 mm liquid prevents atmospheric corrosion carefully clean the surfaces and remove oil and grease (using Hyloma Cleaner, for example) wait approximately 10 minutes for evaporation of the solvent before continuing with assembly. indefinite at ambient temperature Resistance: Polyurethane based sealing paste, extremely adhesive and retaining its elastic properties. Thanks to its excellent heat, mechanical and chemical resistance, Marston is the ideal product for particularly delicate seals. In particular, Marston resists all mineral oils, numerous synthetic oils, lubricants, fuels, additives, air, gas, water and anti-freeze. Marston-Domsel GmbH Quality assurance 14

15

www.ntn-snr.com A U T O M O T I V E / A E R O S P A C E / I N D U S T R Y TS5142.GB - Document non contractuel - NTN-SNR tous droits réservés - 04/13 - Photos: NTN-SNR NTN-SNR ROULEMENTS www.ntn-snr.com - 1 rue des Usines 74000 Annecy France Tel. +33 (0)4 50 65 30 00 S.A. au capital de 11 359 542 - RCS ANNECY B 325 821 072 Id. Fiscale : FR 48 325 821 072 SIRET 325 821 072 00015 Codes APE 2815 Z Code NACE