Comparison of squareness measurements

Similar documents
Joint ILAC CIPM Communication regarding the. Accreditation of Calibration and Measurement Services. of National Metrology Institutes.

Bureau International des Poids et Mesures. International Recognition of NMI Calibration and Measurement Capabilities: The CIPM MRA

Physikalisch Technische Bundesanstalt

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

5 m-measurement system for traceable measurements of tapes and rules

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

125 years of innovation. Cylindricity. Global Excellence in Metrology

DATA SHEET DEA GLOBAL EXTRA

Reproducibility of surface roughness in reaming

INTERNATIONAL OIML R 103 RECOMMENDATION

Pilot Study EURAMET.AUV.V-P1: Bilateral comparison on magnitude of the complex charge sensitivity of accelerometers from 10 Hz to 10 khz

ME 410 Mechanical Engineering Systems Laboratory

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

FINAL REPORT. EUROMET project No Bilateral comparison of DC and AC voltages BEV - NCM. W. Waldmann (BEV, pilot laboratory) P.

DATA SHEET DEA GLOBAL SILVER 07.XX XX.07

DATA SHEET DEA GLOBAL SILVER 05.XX.05

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

The Pitch Diameter of Pipe Taper Thread Measurement and Uncertainty Using Three-Wire Probe

DATA SHEET GLOBAL EVO. Bridge Coordinate Measuring Machines

APMP GUIDELINES FOR ACCEPTING A QUALITY SYSTEM(V.2.0 WD2) approved on July 2010

Straightness & Parallelism

LK V xx Technical Datasheet

Fast Optical Form Measurements of Rough Cylindrical and Conical Surfaces in Diesel Fuel Injection Components

Module-4 Lecture-2 Perpendicularity measurement. (Refer Slide Time: 00:13)

Wojciech Płowucha, Władysław Jakubiec University of Bielsko-Biała, Laboratory of Metrology

Internationally accepted framework for metrology

PIglide AT3 Linear Stage with Air Bearings

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames TW18 3HR

Metrology at the service of the economy, society and citizens

EURO-ASIAN COOPERATION OF NATIONAL METROLOGICAL INSTITUTIONS (COOMET)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

ISO INTERNATIONAL STANDARD

SMD ENS Metrology - National Standards. Short overview. Hugo Pirée. World Metrology Day 2018 Brussels.

MAHR UK PLC I APPLICATION TIP APPLICATION TIP CONTOUR MEASUREMENT PRACTICE-ORIENTED EDGE MEASUREMENT

LEITZ SIRIO LINE VERSION

Volumetric positioning accuracy of a vertical machining center equipped with linear motor drives (evaluated by the laser vector method)

CIPM and CCPR What are these organizations and how do they affect my testing results. Maria Nadal Photometry, Surface Color and Appearance NIST

Verification of large CMMs - Artefacts and Methods - Eugen Trapet, Spain (Trapet Precision and ISM3D)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Optics and optical instruments Field procedures for testing geodetic and surveying instruments. Part 8:

Metrology & Measurement Lab ME-594

Geometrical product specifications (GPS) Dimensional measuring equipment. Part 1: Plain limit gauges of linear size

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Designated Institutes participating in the CIPM MRA

Material measures of length for general use

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

v tome x m microfocus CT

MEASURING CONDITIONS AND UNCERTAINTIES FOR THE COMPARISON AND CALIBRATION OF NATIONAL DOSIMETRIC STANDARDS AT THE BIPM *

Roundness/Cylindricity Measurement ROUNDTEST RA-2200 Series

TR CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF ELECTRICAL DCLF METROLOGY. Approved By: Senior Manager: Mpho Phaloane Revised By:

Calibration Technique for SFP10X family of measurement ICs

queensgate a brand of Elektron Technology

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY

ANAMET Meeting Mechanical Metrology to support NPL Standards

COOMET Pilot Comparison 473/RU-a/09: Comparison of hydrophone calibrations in the frequency range 250 Hz to 200 khz

SIM.EM S9.b, 1 Ω and 10 kω

The Importance of Global Metrology for Standards, Industry and Trade: Metrology in a Dynamic World

Certificate of Calibration

Bilateral Comparison of 10 V and V Standards between the NML (Forbairt) and the BIPM, April 1998

Organisation Internationale de Métrologie Légale

Ramesh H. Aralaguppi 1, T. Subramanian 2

AUTOMATED INSPECTION SYSTEM OF ELECTRIC MOTOR STATOR AND ROTOR SHEETS

Keysight Technologies Optical Power Meter Head Special Calibrations. Brochure

Application of Simulation Software to Coordinate Measurement Uncertainty Evaluation

Catalog No. E Perfectly formed for production, quality control rooms and laboratories form measuring instruments from Mitutoyo

PRODUCT BROCHURE HP-L-10.6 HP-L-20.8 LASER SCANNER FOR COORDINATE MEASURING MACHINES

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Agilent 5527A/B-2 Achieving Maximum Accuracy and Repeatability

Contents. Notes on the use of this publication

This is a preview - click here to buy the full publication

Module 2. Milling calculations, coordinates and program preparing. 1 Pepared By: Tareq Al Sawafta

MACHINE TOOL ALIGNMENT TESTS

AFRIMETS.EM.RF-S1. Attenuation and reflection measurements for coaxials at 100 MHz, 1 GHz and 10 GHz Type N Connector

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

AN ANALYSIS OF THE METROLOGY TECHNIQUES TO IMPROVE QUALITY AND ACCURACY

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

A study of accuracy of finished test piece on multi-tasking machine tool

National Conference on Advances in Mechanical Engineering Science (NCAMES-2016)

Length section: New calibration and research services

Some aspects of traceability of camshafts and large gears

Test Answers and Exam Booklet. Geometric Tolerancing

FÉDÉRATION EUROPÉENNE DE LA MANUTENTION Product Group Industrial Trucks. Floors for Use of Industrial Trucks Very Narrow Aisles Trucks Requirements

Borderline between CIPM MRA and testing activities

LION PRECISION. TechNote LT February, Capacitive Sensor Operation and Optimization

Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere

Version 1.1 (01/2015) EURAMET e.v. Bundesallee 100 D Braunschweig Germany. Phone:

Touch Probe Cycles TNC 426 TNC 430

ISO INTERNATIONAL STANDARD. Hot-rolled steel sections Part 14: Hot-finished structural hollow sections Dimensions and sectional properties

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Bilateral Comparison EURAMET.AUV.V-K1.2. (vibration acceleration) Swiss Federal Office of Metrology METAS Christian Hof

Final Report. Bilateral Comparison on Electric Field Measurements Between TÜBİTAK UME and SASO NMCC GULFMET.EM.RF-S1. UME-EM-D

Ball and Hole plate development for evaluation of µcmm

Fitting Multidimensional Measurement Data to Tolerance Zones Taking into Account for the Uncertainties of Measurements

Certificate of Accreditation

Absolute distance interferometer in LaserTracer geometry

TUTORIAL 4: Combined Axial and Bending Problem Sketch Path Sweep Initial Project Space Setup Static Structural ANSYS

ISO 7465 INTERNATIONAL STANDARD. Passenger lifts and service lifts Guide rails for lift cars and counterweights T-type

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Transcription:

Slovenský metrologický ústav Slovak Institute of Metrology Slowakisches Institut für Metrologie EUROMET Supplementary Comparison #910 Comparison of squareness measurements Final Report Jiri Mokros, SMU, Bratislava, April 2010

Content 1 Introduction...3 2 Organisation...3 3 Participants...3 4 Time schedule...3 5 Description of the Standard...4 6 Measurement instructions...4 6.1 Definitions...4 7 Measurands...5 8 Measurement uncertainty...5 9 Measuring devices and procedures...5 9.1 SMU...5 9.2 GUM...7 10 Results...11 10.1 Straightness...11 11 Conclusion...15

Final Report of EUROMET Comparison of squareness measurements No: 910 3 1 Introduction The comparison of squareness measurement was aimed to compare and verify the declared calibration measurement capabilities of participating after the installation of new (GUM) measurement setup following the project EUROMET #570. As regards the technical parameters, the standard corresponds to the standard currently used in the metrological praxis. It makes possible to compare the standard devices in the real conditions. The standard was calibrated by the measurement process currently used in the participant s laboratory (e.g. in the horizontal or vertical position of the square). This comparison was carried out according to the same Technical protocol as that of the project EUROMET #570. 2 Organisation This comparison was submitted as the EUROMET supplementary comparison in the framework of the Mutual Recognition Arrangement (MRA) of the Metre Convention and was aimed to support a confidence in calibration and measurement certificates issued by the participating national metrology institutes (NMI). The comparison was organized according to the rules set up by the BIPM 1. 3 Participants NMI Address Name E-mail Telephone Karloveská 63, Slovak Institute SMU SK-842 55 Bratislava Jirko Mokroš mokros@smu.gov.sk +421 2 60294 253 of Metrology Slovakia Central Office of Measures GUM ul. Elektoralna 2, 00-950 Warszawa, P-10, Poland Anna Kapinska- Kiszko length@gum.gov.pl +48 22 581 9406 4 Time schedule The time schedule was currently modified few times, reflecting the requirements of participants. The real time schedule is shown in the following table. Laboratory Country Date SMU SK November 2007 GUM PL June 2008 SMU SK September 2008 1 T.J. Quinn, Guidelines for CIPM key comparisons (Appendix F to the MRA, 1. March 1999, BIPM, Paris)

Final Report of EUROMET Comparison of squareness measurements No: 910 4 5 Description of the Standard Cylindrical squareness standard of steel with 102 mm diameter and 401,5 mm height with marked positions for the profile lines, weight 25 kg. 6 Measurement instructions 6.1 Definitions Angle between fitting line (in the case of the cylindrical standard) the angles are understood as the interior angles between the corresponding LS regression-lines fitted through the measured profiles at 30, 120, 210, 300 and the envelope plane of the basis (see Fig. 1). The measured profiles the generatrix profiles at 30, 120, 210, 300 (marked on the "TOP" plane) around the circumference of a cylinder. The starting point of measurement 5 mm from the zero point. Zero points are given by the inter-section of four generatrix profiles with BASIS plane. The density of measuring points of the profile shall be 0,5 mm (in extra cases should be allowed the integer multiple of 0,5 mm, max. 2 mm). Angles of the squares were measured using the technique currently applied by the participant. This method was described in details by each participant in the annex A2 "Measurement Report". Local deviation from straightness the distance between the measured point and the LS regression-line fitted through the measured profile in the measured plane; the positive value corresponded to the orientation outside from the material of square The squares were measured in the position currently used in the laboratory horizontally or vertically. Fig. 1

Final Report of EUROMET Comparison of squareness measurements No: 910 5 Squareness shall be measured using the technique currently used by the participant. This method shall be in details described by each participant in the "Measurement Report". 7 Measurands The following parameters have to be calibrated: - interior angles between the LS regression-line fitted through the measurement profiles at 30, 120, 210, 300 and the envelope plane of the basis (resting on a surface plate), - local LS straightness deviation for all measured profiles (4) of standard (results to be reported in electronic format only). Supplementary data: - radius of the probe tip, - ambient temperature and its time drift during the measurement period, - description of the standard device on which the calibration has been performed, - description of the measurement methods and the data evaluation, - the method of calculation of the combined standard uncertainty u C (k = 1) related to the angle between fitting lines and uncertainty of local deviation from straightness, - measurement uncertainty budget. 8 Measurement uncertainty The combined standard uncertainty u C (k = 1) of all measurement results had to be estimated according to the ISO Guide for the Expression of Uncertainty in Measurement. Participants were asked to report their measurement uncertainty budget in the annex A2 "Measurement Report". 9 Measuring devices and procedures The measuring devices used by the participants are shortly described below. The required form of data reporting was designed in order to reveal possible error sources of individual NMIs. 9.1 SMU Description of measuring device: The measuring device NME 90 (with 1300 mm straightness column, resting on a surface plate and air bearing carriage) compares form and angle position of vertical arm of measured rectangular standard with form and position of measuring column. Air

Final Report of EUROMET Comparison of squareness measurements No: 910 6 bearing carriage bears two inductive sensors, which read a profile line of the measured square. The square standard under test is placed on a granite base plate so its base is connected with this plate (envelope plane). The angle of square is defined by the fitting line (evaluated from individual measured points on vertical arm) and by the horizontal plane, given by the granite base plate of device. Such a determination of square was chosen by the device producers, because this way is usually used in industry. Procedure of measurement: For the measurement of angle standard the well-known method of error separation technique (reversal technique) by means of self-calibration is used. This method allows the evaluation of the profile of square vertical arm without beforehand information about the profile of the measuring column. Process of the measurement consists of two steps measurement of the square standard in 0 position and in 180 position. Procedure of result calculation: Measurement profiles are transferred to an Excel worksheet. The slope of the profiles is calculated by linear regression, resulting in the angle of the squareness standard. Deviation of each measured point from the LS regression line is the local straightness deviation Uncertainty evaluation and budget of angle between fitting lines and uncertainty evaluation and budget of local straightness: For straightness: Quantity X i Estimate x i Standard uncertainty u(x i ) Probability distribution Sensitivity coefficient c i Uncertainty contribution u i (y) [µm] reading of inductive sensor 0 µm 0,03 µm rectangular 1 0,03 flank leading of air bearing 0 µm 4 µm normal 0,001 0,004 insufficient compensation of leading of air bearing due to different initial height 0 µm 25 µm normal 0,002 0,05 quality of contact of sensor with the tested surface 0 µm 0,04 µm normal 1 0,04 Vibrations 0 µm 0,07 µm normal 1 0,07 u c 0,10 Expanded uncertainty U (for k=2) 0,20

Final Report of EUROMET Comparison of squareness measurements No: 910 7 For Angle: Quantity X i Estimate x i Standard uncertainty u(x i ) Probability distribution Sensitivity coefficien c i Uncertainty contribution u i (y) Local deviations of square and base plate Temperature change of the arm of sensor carrier Temperature dilatation coefficient of the arm of the sensor carrier Change of temperature difference between top and bottom baseplate surface Influence of the dilatation temperature coefficient uncertainty through the change of temperature gradient in vertical direction 0 µm/m 0,4 µm/m normal 0,3 0,12 µm/m 0 C 0,012 C normal 8 µm/(m. C) 0,10 µm/m 24 µm/(m. C) 0,6 µm/(m. C) rectagular 0,06 C 0,036 µm/m 0 C 0,096 C normal 96 µm/(m. C) 0,96 µm/m 3,8 µm/(m. C) 0,1 µm/(m. C) rectagular 0,6 C 0,06 µm/m Straightness uncertainty 0 µm 0,10 µm normal 0,5 m -1 0,05 µm/m u c 0,98 µm/m 0,20 Expanded uncertainty U (for k=2) 1,96 µm/m 0,40 " 9.2 GUM Description of measuring device: Coordinate measuring machine CMM5 Nr 302 manufacturer: SIP firm, Switzerland, measuring range: up to 700 mm along X axis, up to 500 mm along Y and Z axis axial measuring accuracy : 0,5 µm + L/1200mm spatial measuring accuracy: 0,8 µm + L/1200mm The machine can measure both in point to point mode and scanning mode

Final Report of EUROMET Comparison of squareness measurements No: 910 8 Procedure of measurement: The cylindrical square was measured in vertical position in ZX measuring plane of the machine. It was placed on the granite surface plate which was set on measuring table of the machine (Fig.1). This surface plate was established a measuring basis. Fig.1. The position of cylindrical square in measuring space of the machine. 1) measuring table of the machine, 2) surface plate, 3) cylindrical square The corresponding LS fitting lines were measured using two methods of measurement. Firstly by probing points using special program for line measurement. Secondly by probing points using scanning mode. The density of measuring points on each line was about 0,5 mm in both used methods of measurement. The angles between the respective LS fitting lines (30, 120, 210,300 ) and envelope plane of the basis were measured five times. The reference system was established according to the axis of the cylindrical square. These two methods of measurement were used for comparison of the results. Procedure of result calculation: The angles between the respective LS fitting lines (30, 120, 210, 300 ) and the basis were calculated as a mean value obtained from all measurements made for the each line. The calculations were carried out for the two methods of measurement separately. As regards the local straightness deviation the corresponding LS fitting lines were estimated from all measured points probed using special program for line measurement. Then the distances between the respective points and corresponding points laying on these lines were calculated. As a result the worst deviations from the respective LS fitting lines were chosen from all measured lines. Uncertainty evaluation and budget of local straightness and budget of angle between fitting lines and uncertainty evaluation: Uncertainty evaluation of angles between respective LS fitting lines and the basis. The total uncertainty of angles between respective LS fitting lines and the basis was evaluated taking into account the following influences: l) short term reproducibility of LS line position,

Final Report of EUROMET Comparison of squareness measurements No: 910 9 2) short term reproducibility of the surface plate position including flatness deviation, 3) error of the angle between two axes of the machine, 4) error emerging from temperature gradient in measuring plane of the machine, 5) error emerging from used method of measurement. Short term reproducibility of every LS fitting line position (30, 120, 210, 300 ) was evaluated as a maximal difference between obtained values of the respective LS fitting line measured five times and repetition of the measuring program for a few days. As a result the worst value obtained from all measurement for each line was accepted. Short term reproducibility of the surface plate position including flatness deviation was evaluated as a sum of the influences emerging from measurement of the surface plate position and influences emerging from measurement of its flatness. The surface plate position was measured every time before measurement of LS fitting line position. The worst value obtained from all measurements was accepted as a result. Flatness of the surface plate was measured before starting of measuring program and then its influence for angle measurement was estimated. Error of the angle between two axes of the machine was taken from calibration certificate of the machine. Error emerging from temperature gradient in measuring plane of the machine was estimated as the following: temperature gradient in measuring plane of the machine during measurement was 0,08 C, thermal expansive coefficient for steel is 11,5* 10-6 * C -1, the value of the length taken into ca1culation is 400 mm, so 0,08 C*11,5*10-6 * C -1 *400 mm = 0,000368 mm, the change of the angle is a = 0,00000092 rad, a = 180 /3,14*0,00000092 = 0,00005 (about 0,2"). The error emerging from used method of measurement was calculated as a maximal difference between the value of the angle obtained from the first method and the value of the angle obtained from the second method. This difference is 0,2"

Final Report of EUROMET Comparison of squareness measurements No: 910 10 Uncertainty budget of local straightness deviation for the cylindrical square Source of uncertainty Short termreproducibility of the local straightness measurement Magnitud e Standard Type of uncertaint distribution y Sensitivity coefficient Uncertainty 0,6 µm Rect. 0,35 µm 1 0,35 µm Probing error 0,3 µm Norm. 0,10 µm 1 0,1 µm Error emerging from temperature gradient in measuring plane 0,5 µm Rect. 0,29 µm 1 0,29 µm Total uncertainty of local straightness deviation for k = 1 is 0,47 µm Uncertainty budget of angle measurement between LS fitting line and the basis Source of uncertainty Magnitude Short term reproducibility of LS fitting line position Short term reproducibility of the surface plate position including flatness deviation Type of distribution Standard uncertainty Sensitivity coefficient Uncertainty 0,7" Rect. 0,41" 1 0,41" 0,7" Rect. 0,41" 1 0,41" Error of the angle between two axes of the machine Error emerging from temperature gradient in measuring plane of the machine Error emerging from used method of measurement 0,3" Rect. 0,18" 1 0,18" 0,2" Rect. 0,12" 1 0,12" 0,2" Rect. 0,12" 1 0,12" Total uncertainty of the angle measurement between LS fitting line and the basis for k = 1 is 0,64". Comments: The density of probed points during measurement of cylindrical square is not exactly 0,5 mm because of the measuring software of the machine. Although the entered value is 0,5 mm the software corrected this value by itself in measuring range.

Final Report of EUROMET Comparison of squareness measurements No: 910 11 10 Results 10.1 Straightness Since the measured profile was unknown beforehand and just two NMIs participated, the results are presented in terms of differences of weighted mean of results, submitted by participants. Measurements of profile 30 : Measurements of profile 120 :

Final Report of EUROMET Comparison of squareness measurements No: 910 12 Measurements of profile 210 : Measurements of profile 300 : The following graphs show the deviations of indidual profiles from the weighted mean and limits corresponding to the En = 1 (for USMU = 0,20 µm, UGUM = 0,94 µm).

Final Report of EUROMET Comparison of squareness measurements No: 910 Differences of profile 30 : Differences of profile 120 : 13

Final Report of EUROMET Comparison of squareness measurements No: 910 14 Differences of profile 210 : Differences of profile 300 : Comments to the graphs: En values exceed 1 just for the 120 profile, namely 4 last points from the total number of 790. It is well bellow the expected number (39 or 40), corresponding to the P = 95% uncertainty.

Final Report of EUROMET Comparison of squareness measurements No: 910 15 Squareness Angle deviations of individual NMIs from 90 : Profiles Angle deviations g SMU (") Angle deviations g GUM (") Diff. SMU (") Diff. GUM (") En value (") 30 2,19 1,94-0,02 0,22 0,26 120-1,54-1,98-0,04 0,40 0,46 210-3,10-3,02 0,01-0,07 0,08 300 1,10 1,40 0,03-0,28 0,32 The reference values were calculated as the weighted mean deviations from 90 for each profile (U SMU = 0,20", U GUM = 1,28") 11 Conclusion Taking into account the calculated value of En, the results of measured straightness can be (with the comments to the graphs) claimed as consistent. Taking into account the calculated value of En, the difference between values of measured angle submitted by both participants can be claimed as consistent. Therefore it can be concluded that both NMIs meet the MRA criteria required for the acceptation of claimed uncertainties for both parameters (squareness, straightness).