Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Similar documents
Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

EMISSION. EN : 2006 Clause 6.5 Pass. Harmonic Current EN : 2006+A1: 2009+A2: 2009 Class A Pass

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

EN : 2006 Clause 6.5 Pass. Harmonic Current EN : 2006+A1: 2009+A2: 2009 Class A Pass

Radio Spectrum. RF output power ETSI EN V2.1.1: dBm Pass

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

EMC VERIFICATION SUMMARY Report No.: SZHH

TEST REPORT... 1 CONTENT...

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

Page: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6

EMC TEST REPORT : EGO-PZ001, EGO-PZ002, EGO-PZ003, EGO-PZ004, EGO-PZ005, EGO-PZ006, EGO-PZ007, EGO-PZ008

EMC test report AU01+E04

Page: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan

1 SUMMARY OF STANDARDS AND RESULTS

Declaration of Conformity.

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

Page: 1 of 44 EMC TEST REPORT. : Gembird Electronics Ltd. Room 1709, News Building, #2 Shennan Zhong Lu, Shenzhen, China

ELECTRONICS TESTING CENTER(ETC), TAIWAN

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

EMC Test Report. Report Number: M030826

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

Test Report GUANGDONG EAST POWER CO., LTD

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass

EMC standards. Presented by: Karim Loukil & Kaïs Siala

5.3 TEST SETUP AND PROCEDURE TEST DATA MEASUREMENT UNCERTAINTY FLICKER USED TEST EQUIPMENT...18

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

2620 Modular Measurement and Control System

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

EMC Test Report. Shenzhen JT Detection Technology Co., Ltd. Product : Car LED headlight bulbs Brand Name :WEIYAO AUTO LED.

SGS-CSTC Standards Technical Services. SGS-CSTC(Shanghai)Co.,Ltd EMC TEST REPORT SHEMO AV01-A2 LINCON AUTOMATION CO., LTD

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 54 Page 2 of 54

BS EN TESTS ON THE RS-485 FFP2 THE BRAIN REVISION C

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

TEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

EMC TEST REPORT For Prokits Industries Co., Ltd.

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

C E R T I F I C A T I O N

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

Shenzhen Huanxi Technology Co., Ltd. Smart Self-balancing Scooter

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

EMC TEST REPORT For CE

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

EMC TEST REPORT. Report No.: CE10-LIE040101E

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

EMC Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. Power supply STR E. Damon Ma / Engineer

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

Contents. Report No.: EMC-CE-2114 Page: 2 of 39

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

1- GENERAL INFORMATION SYSTEM TEST CONFIGURATION DISTURBANCE VOLTAGE AT THE MAINS TERMINALS RADIATED DISTURBANCES...

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

BUREAU VERITAS. itaste svd

EMC TEST REPORT. Page: 1 of 41. : Netion Electronic Co., Ltd. : Fanhu Industrial Park, Sanshui, Foshan, Guangdong, China. Equipment Under Test (EUT) :

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

CE EMC TEST REPORT. MANUFACTURER : TP-Link Technologies Co., Ltd.

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

EMC TEST REPORT CE TEST REPORT. Report Number : ETLE Report issue date: August 21, 2009

EMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20

EMC TEST REPORT CE TEST REPORT. for Audio / Video receivers and associated equipment

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

Page: 1 of 51 EMC TEST REPORT

Test Report GUANGDONG EAST POWER CO., LTD

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

EMC TEST REPORT. according to

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

TEST REPORT EMC. 1, Mikhaila Kotzubinskogo St., Kyiv, Ukraine, IECCISPR14_1&2_IEC61000_3_2&3B

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

Report No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for

EMC Test report for Plug-in adaptor Models PM1Wab-ccc

C E R T I F I C A T I O N

TEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015.

Transcription:

Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result EN 55014-1:2006+A1:2009+A2:2011 Clause 4.1.1 Pass EN 55014-1:2006+A1:2009+A2:2011 Clause 4.1.2 Pass EN 55014-1:2006+A1:2009+A2:2011 Clause 4.2.2 N/A** EN 55014-1:2006+A1:2009+A2 :2011 Clause 4.1.2 N/A Harmonic Current emission EN 61000-3-2:2014 Class A Pass Voltage Fluctuation and Flicker EN61000-3-3:2013 Clause 5 Pass IMMUNITY(EN 55014-2:1997+A1:2001+A2:2008) Test Item Test Method Class / Severity Electrostatic Discharge(ESD) IEC 61000-4-2:2008 Radio-frequency electromagnetic fields (80MHz to 1GHz) IEC 61000-4-3:2010 Electrical Fast Transients (EFT) IEC 61000-4-4:2012 Surge IEC 61000-4-5:2005 Injected Currents, 0.15MHz to 230MHz IEC 61000-4-6:2013 4 Kv Contact 8 Kv Air 3V/m, 80%, 1kHz, Amp. Mod. AC 1.0Kv DC 0.5Kv 1Kv D.M. 2Kv C.M. 3Vr.m.s.(emf), 80%, 1kHz Amp. Mod. 0 % U T * for 0.5per Performance Criteria B A B B A Result Pass N/A Pass Pass Pass Pass Voltage Dips and Interruptions IEC 61000-4-11:2004 40 % U T * for 10per C Pass 70 % U T * for 25per Pass Remark: Pass Fail N/A A.M Test item meets the requirement Test item does not meet the requirement Test case does not apply to the test object Amplitude Modulation Differential Mode Common Mode * U T is the nominal supply voltage ** According to the electrical characteristics and usage of the equipment, the EUT does not produce discontinuous radio interference voltages on AC Mains. Therefore this test item has been skipped.

Reference No.: WTS15F0323845E Page 3 of 33 2 Contents Page COVER PAGE 1 1 TEST SUMMARY...2 2 CONTENTS...3 3 GENERAL INFORMATION...5 3.1 GENERAL DESCRIPTION OF E.U.T.... 5 3.2 DETAILS OF E.U.T.... 5 3.3 DESCRIPTION OF SUPPORT UNITS... 5 3.4 STANDARDS APPLICABLE FOR TESTING... 5 3.5 TEST FACILITY... 6 3.6 SUBCONTRACTED... 6 3.7 ABNORMALITIES FROM STANDARD CONDITIONS... 6 4 EQUIPMENT USED DURING TEST...7 4.1 MEASUREMENT UNCERTAINTY... 8 5 EMISSION TEST RESULTS...9 5.1 MAINS TERMINALS DISTURBANCE VOLTAGE, 148.5KHZ TO 30MHZ... 9 5.1.1 E.U.T. Operation...9 5.1.2 Block Diagram of Test Setup...9 5.1.3 Measurement Data... 10 5.1.4 Mains Terminals Disturbance Voltage Test Data... 10 5.2 DISTURBANCE POWER, 30MHZ TO 300MHZ... 12 5.2.1 E.U.T. Operation... 12 5.2.2 Block Diagram of Test Setup... 12 5.2.3 Measurement Data... 13 5.2.4 Disturbance Power Test Results on AC Line... 13 5.3 HARMONICS CURRENT EMISSION... 14 5.3.1 E.U.T. Operation... 14 5.3.2 Block Diagram of Setup... 14 5.3.3 Harmonic Current Emission Test Data... 15 5.4 VOLTAGE FLUCTUATION AND FLICKER... 18 5.4.1 E.U.T. Operation... 18 5.4.2 Block Diagram of Setup... 18 5.4.3 Voltage Fluctuation and Flicker Test Data... 19 6 IMMUNITY TEST RESULTS... 20 6.1 PERFORMANCE CRITERIA... 20 6.2 ELECTROSTATIC DISCHARGE (ESD)... 20 6.2.1 E.U.T. Operation... 21 6.2.2 Block Diagram of Setup... 21 6.2.3 Direct Discharge Test Results... 22 6.2.4 Indirect Discharge Test Results... 22 6.3 ELECTRICAL FAST TRANSIENTS (EFT)... 22 6.3.1 E.U.T. Operation... 23 6.3.2 Block Diagram of Setup... 23 6.3.3 Test Results... 23 6.4 SURGE... 24 6.4.1 E.U.T. Operation... 24 6.4.2 Block Diagram of Setup... 24 6.4.3 Test Results... 25 6.5 INJECTED CURRENTS IMMUNITY, 0.15MHZ TO 230MHZ... 25

Reference No.: WTS15F0323845E Page 4 of 33 6.5.1 E.U.T. Operation... 25 6.5.2 Block Diagram of Setup... 26 6.5.3 Test Results... 26 6.6 VOLTAGE DIPS AND INTERRUPTIONS... 27 6.6.1 E.U.T. Operation... 27 6.6.2 Block Diagram of Setup... 27 6.6.3 Test Results... 28 7 PHOTOGRAPHS TEST SETUP... 29 7.1 PHOTOGRAPH MAINS TERMINAL DISTURBANCE VOLTAGE TEST SETUP... 29 7.2 PHOTOGRAPH DISTURBANCE POWER TEST SETUP... 29 7.3 PHOTOGRAPH HARMONIC CURRENT AND VOLTAGE FLUCTUATION AND FLICKER TEST SETUP... 30 7.4 PHOTOGRAPH ESD IMMUNITY TEST SETUP... 30 7.5 PHOTOGRAPH EFT IMMUNITY TEST SETUP... 31 7.6 PHOTOGRAPH SURGE IMMUNITY TEST SETUP... 31 7.7 PHOTOGRAPH INJECTED CURRENTS IMMUNITY TEST SETUP... 32 7.8 PHOTOGRAPH VOLTAGE DIPS AND INTERRUPTIONS IMMUNITY TEST SETUP... 32 8 PHOTOGRAPHS CONSTRUCTIONAL DETAILS... 33 8.1 EUT FRONT VIEW... 33

Reference No.: WTS15F0323845E Page 5 of 33 3 General Information 3.1 General Description of E.U.T. Product Name... : Electric height adjustable desk frame Model No.... : A6 Remark... : --- 3.2 Details of E.U.T. Technical Data... : AC 220-240, 50Hz, 240W 3.3 Description of Support Units The EUT has been tested as an independent unit. A6 is the test sample. The DV,DP tests were performed in the condition of AC264V/50Hz input. The other tests were performed in the condition of AC 230V/50Hz input. 3.4 Standards Applicable for Testing The tests were performed according to following standards: EN55014-1:2006+A1:2009 +A2:2011 EN55014-2:1997+A1:2001 +A2:2008 EN 61000-3-2:2014 EN 61000-3-3:2013 Electromagnetic compatibility-requirements for household appliances, electric tools and similar apparatus-part 1:Emission Electromagnetic compatibility Requirements for household appliances, Part 2: Immunity Product family. Electromagnetic compatibility (EMC) -- Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase). Electromagnetic compatibility (EMC) -- Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current 16 A per phase and not subject to conditional connection.

Reference No.: WTS15F0323845E Page 6 of 33 3.5 Test Facility The test facility has a test site registered with the following organizations: IC Registration No.: 7760A Waltek Services (Shenzhen) Co., Ltd. has been registered and fully described in a report filed with the Industry Canada. The acceptance letter from the Industry Canada is maintained in our files. Registration 7760A, August 03, 2010. FCC Registration No.: 880581 Waltek Services (Shenzhen) Co., Ltd. has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration 880581, May 26, 2011. 3.6 Subcontracted Whether parts of tests for the product have been subcontracted to other labs: Yes No If Yes, list the related test items and lab information: Test items:--- Lab information:--- 3.7 Abnormalities from Standard Conditions None.

Reference No.: WTS15F0323845E Page 7 of 33 4 Equipment Used during Test Mains Terminal Disturbance Voltage (Conducted Emission) Item Equipment Manufacturer Model No. Serial No. Calibration Status 1. EMI Test Receiver R&S ESCI 101178 Valid 2. LISN R&S ENV216 101215 Valid 3. LISN SCHWARZBECK NSLK 8128 8128-289 Valid 4. Cable HUBER+SUHNER CBL2-NN-3M 2230300 Valid 5. Switch ESE RSU/M2 --- Valid Disturbance Power Item Equipment Manufacturer Model No. Serial No. Calibration Status 1. EMI Test Receiver R&S ESCI 101178 Valid 2. Absorbing Clamp LUTHI MDS21 4067 Valid 3. Cable HUBER+SUHNER CBL2-NN-9M 2230900 Valid 4. Switch ESE RSU/M2 --- Valid Discontinuous Disturbance Item Equipment Manufacturer Model No. Serial No. Calibration Status 1. Discontinues Disturbance Analyzer TESEQ DIA1512D 28302 Valid 2. LISN R&S ENV216 101215 Valid Harmonics and Flicker Measuring System Item Equipment Manufacturer Model No. Serial No. Calibration Status 1. ESD Harmonics and Flicker Measuring System TESEQ PROFLINE210 5-400 1133A014 98 Item Equipment Manufacturer Model No. Serial No. Calibration Status Valid 1. ESD Simulator TESEQ NSG437 521 Valid EFT & Voltage Dips and Interruptions Item Equipment Manufacturer Model No. Serial No. Calibration Status 1. EMS test system TESEQ NSG3040 0319 Valid 2. Clamp TESEQ CDN8014 31405 Valid Surge Item Equipment Manufacturer Model No. Serial No. Calibration Status 1. Surge Simulator TESEQ NSG3060 1395 Valid Injected Currents

Reference No.: WTS15F0323845E Page 8 of 33 Item Equipment Manufacturer Model No. Serial No. Calibration Status 1. Conducted Immunity test system TESEQ NSG4070-75 31469 Valid 2. CDN TESEQ M016 31586 Valid 3. Clamp TESEQ KEMZ801 32362 Valid 4.1 Measurement Uncertainty Test Item Frequency Range Uncertainty Note Conducted Emission 150kHz~30MHz 2.66dB (1) Disturbance Power 30MHz~300MHz 3.21dB (1) Radiated Emission 30MHz~1GHz 5.03dB (1) (1)This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

Reference No.: WTS15F0323845E Page 9 of 33 5 Emission Test Results 5.1 Mains Terminals Disturbance Voltage, 148.5kHz to 30MHz Test Requirement... : EN 55014-1 Test Method... : EN 55014-1 Test Result... : Pass Frequency Range... : 148.5kHz to 30MHz Class/Severity... : Table 1 of EN55014-1 5.1.1 E.U.T. Operation Operating Environment: Temperature... : 23.1 C Humidity... : 42.0%RH Atmospheric Pressure... : 101.2kPa EUT Operation: Input Voltage... : AC 264V/50Hz Operating Mode... : On mode 5.1.2 Block Diagram of Test Setup The Mains Terminals Disturbance Voltage tests were performed in accordance with the EN 55014-1.

Reference No.: WTS15F0323845E Page 10 of 33 5.1.3 Measurement Data The maximised peak emissions from the EUT was scanned and measured for both the Live and Neutral Lines. Quasi-peak & average measurements were performed if peak emissions were within 6dB of the average limit line. 5.1.4 Mains Terminals Disturbance Voltage Test Data Live Line :

Reference No.: WTS15F0323845E Page 11 of 33 Neutral Line :

Reference No.: WTS15F0323845E Page 12 of 33 5.2 Disturbance Power, 30MHz to 300MHz Test Requirement... : EN 55014-1 Test Method... : EN 55014-1 Test Result... : Pass Frequency Range... : 30MHz to 300MHz Class/Severity... : Table 2 of EN55014-1 5.2.1 E.U.T. Operation Operating Environment: Temperature... : 23.1 C Humidity... : 42.0%RH Barometric Pressure... : 101.2kPa EUT Operation: Input Voltage... : AC 264V/50Hz Operating Mode... : On mode 5.2.2 Block Diagram of Test Setup The Disturbance Power test was performed in accordance with the EN 55014-1.

Reference No.: WTS15F0323845E Page 13 of 33 5.2.3 Measurement Data Extending the cable to 6 meters, performed quasi-peak & average measurements since peak emissions from the EUT were detected within 15dB of the limit line. Average measurements were only performed if the quasi-peak measurements were within 15dB of the average limit line. According to the Clause 4.1.2.3, if both of the following conditions (1) and (2) are fulfilled: 1) all emission readings from the equipment under test shall be lower than the applicable limits (Table 2a) reduced by the margin (Table 2b); 2) the maximum clock frequency shall be less than 30 MHz. The Appliances are deemed to comply in the frequency range from 300 MHz to 1 000 MHz 5.2.4 Disturbance Power Test Results on AC Line

Reference No.: WTS15F0323845E Page 14 of 33 5.3 Harmonics Current Emission Test Requirement... : EN61000-3-2 Test Method... : EN61000-3-2 Test Result... : Pass Class/Severity... : Class A 5.3.1 E.U.T. Operation Operating Environment: Temperature... : 23.1 C Humidity... : 42.0%RH Barometric Pressure... : 101.2kPa EUT Operation: Input Voltage... : AC 230V/50Hz Operating Mode... : On mode 5.3.2 Block Diagram of Setup The Harmonics Current emission test was performed in accordance with the EN 61000-3-2.

Reference No.: WTS15F0323845E Page 15 of 33 5.3.3 Harmonic Current Emission Test Data

Reference No.: WTS15F0323845E Page 16 of 33

Reference No.: WTS15F0323845E Page 17 of 33

Reference No.: WTS15F0323845E Page 18 of 33 5.4 Voltage Fluctuation and Flicker Test Requirement... : EN 61000-3-3 Test Method... : EN 61000-3-3 Test Result... : Pass 5.4.1 E.U.T. Operation Operating Environment: Temperature... : 23.1 C Humidity... : 42.0%RH Barometric Pressure... : 101.2kPa EUT Operation: Input Voltage... : AC 230V/50Hz Operating Mode... : On mode 5.4.2 Block Diagram of Setup The Voltage Fluctuation and Flicker test was performed in accordance with the EN 61000-3-3.

Reference No.: WTS15F0323845E Page 19 of 33 5.4.3 Voltage Fluctuation and Flicker Test Data

Reference No.: WTS15F0323845E Page 20 of 33 6 Immunity Test Results 6.1 Performance Criteria Performance criterion A: The apparatus shall continue to operate as intended during the test. No degradation of performance or loss of function is allowed below a performance level (or permissible loss of performance) specified by the manufacturer, when the apparatus is used as intended. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended. Performance criterion B: The apparatus shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level (or permissible loss of performance) specified by the manufacturer, when the apparatus is used as intended. During the test, degradation of performance is allowed, however, no change of actual operating state or stored data is allowed. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended. Performance criterion C: Temporary loss of function is allowed, provided the function is selfrecoverable or can be restored by the operation of the controls, or by any operation specified in the instructions for use. For further details, please refer to EN 55014-2. 6.2 Electrostatic Discharge (ESD) Test Requirement... : EN 55014-2 Test Method... : IEC 61000-4-2 Test Result... : Pass Discharge Impedance... : 330 / 150pF Discharge Voltage... : Air Discharge: ±8kV Contact Discharge: ±4kV HCP & VCP: ±4kV Polarity... : Positive & Negative Number of Discharge... : Minimum 10 times at each test point Discharge Mode... : Single Discharge Discharge Period... : 1 second minimum

Reference No.: WTS15F0323845E Page 21 of 33 6.2.1 E.U.T. Operation Operating Environment: Temperature... : 23.4 C Humidity... : 46.3%RH Barometric Pressure... : 101.3kPa EUT Operation: Input Voltage... : AC 230V/50Hz Operating Mode... : On mode 6.2.2 Block Diagram of Setup The ESD test was performed in accordance with the IEC 61000-4-2.

Reference No.: WTS15F0323845E Page 22 of 33 6.2.3 Direct Discharge Test Results Observations: Test points: 1. All Exposed Surface & Seams; 2. All metallic part Direct Discharge Test Results Applied Voltage (kv) Performance Criterion Test Point Contact Discharge Air Discharge ±8 B 1 N/A Pass* ±4 B 2 Pass* N/A Remark: * During the test no deviation was detected to the selected operation mode(s) 6.2.4 Indirect Discharge Test Results Observations: Test points: 1. All sides. Indirect Discharge Test Results Applied Voltage (kv) Performance Criterion Test Point Horizontal Coupling Vertical Coupling ±4 B 1 Pass* Pass* Remark: * During the test no deviation was detected to the selected operation mode(s) 6.3 Electrical Fast Transients (EFT) Test Requirement... : EN 55014-2 Test Method... : IEC 61000-4-4 Test Result... : Pass Test Level... : 1.0kV on AC Mains Polarity... : Positive & Negative Repetition Frequency... : 5kHz Burst Duration... : 300ms Test Duration... : 2 minutes per level & polarity

Reference No.: WTS15F0323845E Page 23 of 33 6.3.1 E.U.T. Operation Operating Environment: Temperature... : 23.4 C Humidity... : 46.3%RH Barometric Pressure... : 101.3kPa EUT Operation: Input Voltage... : AC 230V/50Hz Operating Mode... : On mode 6.3.2 Block Diagram of Setup The Electrical Fast Transients Immunity test was performed in accordance with the IEC 61000-4-4. 6.3.3 Test Results Test Port Test Level(kV) Performance Criterion Result Line-Neutral 1.0 B Pass* Remark: * During the test no deviation was detected to the selected operation mode(s)

Reference No.: WTS15F0323845E Page 24 of 33 6.4 Surge Test Requirement... : EN 55014-2 Test Method... : IEC 61000-4-5 Test Result... : Pass Test level... : 1kV Live to Neutral, 2kV Live to PE and Neutral to PE, Interval... : 60s between each surge No. of surges... : 5 positive at 90, 5 negative at 270. 6.4.1 E.U.T. Operation Operating Environment: Temperature... : 23.4 C Humidity... : 46.3%RH Barometric Pressure... : 101.3kPa EUT Operation: Input Voltage... : AC 230V/50Hz Operating Mode... : On mode 6.4.2 Block Diagram of Setup The Surge Immunity test was performed in accordance with the IEC 61000-4-5.

Reference No.: WTS15F0323845E Page 25 of 33 6.4.3 Test Results Test Port Applied Voltage (kv) Performance criterion Result Between Phase And Phase 1 B N/A Between Live And Neutral 1 B Pass* Between Live And Earth 2 B N/A Between Neutral And Earth 2 B N/A Remark: * During the test no deviation was detected to the selected operation mode(s) 6.5 Injected Currents Immunity, 0.15MHz to 230MHz Test Requirement... : EN 55014-2 Test Method... : IEC 61000-4-6 Test Result... : Pass Frequency Range... : 0.15MHz to 230MHz Test level... : 3V r.m.s. (unmodulated emf into 150 ) Modulation... : 80%, 1kHz Amplitude Modulation. 6.5.1 E.U.T. Operation Operating Environment: Temperature... : 23.4 C Humidity... : 46.3%RH Barometric Pressure... : 101.3kPa EUT Operation: Input Voltage... : AC 230V/50Hz Operating Mode... : On mode

Reference No.: WTS15F0323845E Page 26 of 33 6.5.2 Block Diagram of Setup The Injected Currents Immunity test was performed in accordance with the IEC 61000-4-6. 6.5.3 Test Results Frequency Line Test Level Modulation Step Size Dwell Time Performance Criterion Result 0.15MHz to 230MHz 2 Wire AC Supply Cables 3Vr.m.s. 80%, 1kHz Amp. Mod. 1% 1s A Pass* Remark: * During the test no deviation was detected to the selected operation mode(s)

Reference No.: WTS15F0323845E Page 27 of 33 6.6 Voltage Dips and Interruptions Test Requirement... EN 55014-2 Test Method... IEC 61000-4-11 Test Result... Test Level(Voltage reduction) No. of Dips / Interruptions... 6.6.1 E.U.T. Operation Pass 0% & 40% &70 % of U T (Supply Voltage) 1 per Level at 20ms intervals Operating Environment: Temperature... Humidity... Barometric Pressure... EUT Operation: Input Voltage... 23.4 C 46.3%RH 101.3kPa AC 230V/50Hz Operating Mode... On mode 6.6.2 Block Diagram of Setup The Voltage Dips and Interruptions Immunity test was performed in accordance with the IEC 61000-4- 11.

Reference No.: WTS15F0323845E Page 28 of 33 6.6.3 Test Results Test Level in %U T Performance criterion 50Hz 60Hz Duration Result Duration Result 0 C 0.5 Pass* 0.5 N/A 40 C 10 Pass* 12 N/A 70 C 25 Pass* 30 N/A Remark: * During the test no deviation was detected to the selected operation mode(s)

Reference No.: WTS15F0323845E Page 29 of 33 7 Photographs Test Setup 7.1 Photograph Mains Terminal Disturbance Voltage Test Setup 7.2 Photograph Disturbance Power Test Setup

Reference No.: WTS15F0323845E Page 30 of 33 7.3 Photograph Harmonic Current and Voltage Fluctuation and Flicker Test Setup 7.4 Photograph ESD Immunity Test Setup

Reference No.: WTS15F0323845E Page 31 of 33 7.5 Photograph EFT Immunity Test Setup 7.6 Photograph Surge Immunity Test Setup

Reference No.: WTS15F0323845E Page 32 of 33 7.7 Photograph Injected Currents Immunity Test Setup 7.8 Photograph Voltage Dips and Interruptions Immunity Test Setup

Reference No.: WTS15F0323845E Page 33 of 33 8 Photographs Constructional Details 8.1 EUT Front View ====== End of Report ======