Comparative Analysis of an SPWM Inverter and Vector Control Method for control of an Adjustable AC Drive

Similar documents
ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

International Journal of Advance Engineering and Research Development

Analysis of Advanced Techniques to Eliminate Harmonics in AC Drives

Speed Control of Induction Motor using Space Vector Modulation

Space Vector PWM Voltage Source Inverter Fed to Permanent Magnet Synchronous Motor

Analysis of Voltage Source Inverters using Space Vector PWM for Induction Motor Drive

Design of Three Phase SVPWM Inverter Using dspic

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

A Sliding Mode Controller for a Three Phase Induction Motor

Closed Loop Control of Three-Phase Induction Motor using Xilinx

SINGLE PHASE BRIDGELESS PFC FOR PI CONTROLLED THREE PHASE INDUCTION MOTOR DRIVE

Simulation Analysis of Three Phase & Line to Ground Fault of Induction Motor Using FFT

Speed Control of Induction Motor using Multilevel Inverter

NPTEL

An Induction Motor Control by Space Vector PWM Technique

Comparative Analysis of Space Vector Pulse-Width Modulation and Third Harmonic Injected Modulation on Industrial Drives.

Reduction of Harmonics and Torque Ripples of BLDC Motor by Cascaded H-Bridge Multi Level Inverter Using Current and Speed Control Techniques

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

SVPWM Based Two Level VSI for Micro Grids

Harmonics White Paper

International Journal of Advance Engineering and Research Development

HIGH PERFORMANCE CONTROL OF AC DRIVES WITH MATLAB/SIMULINK MODELS

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Journal of Engineering Technology

Volume I Issue VI 2012 September-2012 ISSN

OPTIMAL TORQUE RIPPLE CONTROL OF ASYNCHRONOUS DRIVE USING INTELLIGENT CONTROLLERS

Nicolò Antonante Kristian Bergaplass Mumba Collins

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

A Novel Four Switch Three Phase Inverter Controlled by Different Modulation Techniques A Comparison

Comparison between Scalar & Vector Control Technique for Induction Motor Drive

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

CHAPTER 3 VOLTAGE SOURCE INVERTER (VSI)

Modeling and Simulation of Induction Motor Drive with Space Vector Control

ADVANCED DC-DC CONVERTER CONTROLLED SPEED REGULATION OF INDUCTION MOTOR USING PI CONTROLLER

CHAPTER 4 CONTROL ALGORITHM FOR PROPOSED H-BRIDGE MULTILEVEL INVERTER

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

THE rapid development of power electronics in recent

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

Performance Analysis of Induction Motor Drive Fed by VSI for Various Modulation Index

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

Control of Induction Motor Fed with Inverter Using Direct Torque Control - Space Vector Modulation Technique

Analysis & Hardware Implementation Of Three-Phase Voltage Source Inverter

Modeling and Analysis of Common-Mode Voltages Generated in Medium Voltage PWM-CSI Drives

The Amalgamation Performance Analysis of the LCI and VSI Fed Induction Motor Drive

Development of a V/f Control scheme for controlling the Induction motorboth Open Loop and Closed Loop using MATLAB.

ON-LINE NONLINEARITY COMPENSATION TECHNIQUE FOR PWM INVERTER DRIVES

Study of Power Factor Correction in Single Phase AC-DC Converter

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 06, 2014 ISSN (online):

Performance Enhancement of Sensorless Control of Z-Source Inverter Fed BLDC Motor

Modeling and Simulation of Matrix Converter Using Space Vector PWM Technique

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

Modeling and Simulation of Five Phase Induction Motor Fed with Five Phase Inverter Topologies

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

Induction motor control by vector control method.

SVPWM Based Speed Control of Induction Motor with Three Level Inverter Using Proportional Integral Controller

Comparative Analysis of Multiple-pulse VSC-Based STATCOM s for Voltage-Dip Mitigation

CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Simulation and Analysis of Space Vector PWM Inverter Fed Three Phase Induction Motor Drive

Space Vector PWM and Model Predictive Control for Voltage Source Inverter Control

CHAPTER-III MODELING AND IMPLEMENTATION OF PMBLDC MOTOR DRIVE

DIRECT TORQUE CONTROL OF THREE PHASE INDUCTION MOTOR BY USING FOUR SWITCH INVERTER

A NEW DESIGN METHOD OF OUTPUT FILTER FOR SPACE VECTOR PWM FED INDUCTION MOTOR

p. 1 p. 6 p. 22 p. 46 p. 58

A VARIABLE SPEED PFC CONVERTER FOR BRUSHLESS SRM DRIVE

Harmonics Elimination Using Shunt Active Filter

Hybrid 5-level inverter fed induction motor drive

A Switched Boost Inverter Fed Three Phase Induction Motor Drive

Experiment 3. Performance of an induction motor drive under V/f and rotor flux oriented controllers.

Simulation of Five Phase Voltage Source Inverter with Different Excitation for Star Connected Load

ANALYSIS OF POWER QUALITY IMPROVEMENT OF BLDC MOTOR DRIVE USING CUK CONVERTER OPERATING IN DISCONTINUOUS CONDUCTION MODE

Self-Excitation and Voltage Control of an Induction Generator in an Independent Wind Energy Conversion System

Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives

Analysis and Comparison of DTC Technique in 2 Levels & 3 Level Inverter Fed Induction Motor Drive

CHAPTER 2 CURRENT SOURCE INVERTER FOR IM CONTROL

Control of Induction Motor Drive using Space Vector PWM

A Novel Voltage and Frequency Control Scheme for a Wind Turbine Driven Isolated Asynchronous Generator

Simulation of Speed Control of Induction Motor with DTC Scheme Patel Divyaben Lalitbhai 1 Prof. C. A. Patel 2 Mr. B. R. Nanecha 3

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

A Performance Study of PI controller and Fuzzy logic controller in V/f Control of Three Phase Induction Motor Using Space Vector Modulation

FUZZY LOGIC BASED DIRECT TORQUE CONTROL OF THREE PHASE INDUCTION MOTOR

SCOTT TRANSFORMER AND DIODE CLAMPED INVERTER FED INDUCTION MOTOR BASED ON FOC

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

A Novel Three-Phase to Nine-Phase Transformation using a Special Transformer Connection

Voltage Regulated Five Level Inverter Fed Wind Energy Conversion System using PMSG

A NOVEL SWITCHING PATTERN OF CASCADED MULTILEVEL INVERTERS FED BLDC DRIVE USING DIFFERENT MODULATION SCHEMES

Current Control Technique for Three Phase Shunt Active Power Filter by Using Adaptive Hysteresis Current Controller

IN MANY industrial applications, ac machines are preferable

Research on Parallel Interleaved Inverters with Discontinuous Space-Vector Modulation *

Research Article International Journals of Advanced Research in Computer Science and Software Engineering ISSN: X (Volume-7, Issue-6)

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

Induction Motor Drive using SPWM Fed Five Level NPC Inverter for Electric Vehicle Application

CHAPTER 5 MODIFIED SINUSOIDAL PULSE WIDTH MODULATION (SPWM) TECHNIQUE BASED CONTROLLER

Grid Interconnection of Wind Energy System at Distribution Level Using Intelligence Controller

EE POWER ELECTRONICS UNIT IV INVERTERS

A Series-Connected Multilevel Inverter Topology for Squirrel-Cage Induction Motor Drive

Keywords - Induction motor, space vector PWM, DTC, sensorless control, reconstruction.

South Asian Journal of Engineering and Technology Vol.2, No.16 (2016) 21 30

Transcription:

Comparative Analysis of an SPWM Inverter and Vector Control Method for control of an Adjustable AC Drive Ritika Verma 1 1 Student, M.Tech, Department of Electrical & Electronics Engineering, LNCT, Bhopal (M.P.), India Abstract Now-a-days, adjustable speed drive has became a significant load component for power distribution system. It involves the use of Induction motors (Wound rotor type & squirrel cage ) The paper here is based on analysis, control and modeling of induction motors and also investigates its effects on Total current harmonic distortion on an adjustable speed by the use of PWM generator and Vector control method. With the help of Park s transformation,we can convert three phase system to two phase and then it can be converted into two axes system (d, q). By varying two vectors of flux and torque, the rotor current can be controlled and therefore, THD and speed for current and voltage is calculated. Keywords - Adjustable speed drives, PWM generator, MATLAB/Simulink, squirrel cage induction motors, three phase stator currents, Vector control. I. ADJUSTABLE SPEED DRIVES Now-a-days, Adjustable Speed drives are widely used in many applications. The use of ASDs leads to current harmonics pollution in the power grid. Since these loads results in unacceptable levels of voltage distortion, these are highly undesirable. Harmonic measurements require special equipment, which is quite expensive and not always available. This paper investigates the modeling and control of an Induction machine for an adjustable speed drive and harmonic analysis was carried out. Using ac drives and ac motors have the advantages of lower maintenance, higher speeds and smaller size. Compared to dc drives, the higher cost of ac drives is in part compensated by a lower ac machine cost. Compared to uncontrolled ac motors, supplied by a power grid, the efficiency of inverter controlled drives can be vastly increased by, e.g. flux optimization. II. INDUCTION MACHINE Per-phase equivalent circuits which are often used in design and analysis of ac machines are appropriate for the static analysis but not to predict the dynamic behaviour of the motor. A dynamic model is necessary to understand and analyze vector control of ac motor drives. With the development of reference frame theory, a significant breakthrough was achieved in the analysis of three-phase ac machines. The machine model can be transformed to another reference frame to using these techniques. It is possible to simplify the complexity of the mathematical machine model by judicious choice of the reference frame. The need for compact and accurate machine models is obvious, as digital control techniques are being extended to control current, torque and flux of the ac machines. The induction motor is the most widely used motor type in industry because of its good self-starting capability, low cost, simple and rugged structure, and reliability, etc. Induction motors are used in adjustable speed applications where fast dynamic response is not required. With the concept of vector control it is possible to control the induction motors to achieve dynamic performance comparable to that of dc motors. The dynamic model of the induction motor is necessary in order to understand and analyze vector control. The characteristics of induction motors are easily described by the dynamic model equations developed on a rotating reference frame and then it is converted to stationery frame. 2013 Copyright IRJEAS. All Rights Reserved 10

III. THE CONCEPT OF HARMONIC A harmonic is a component of periodic wave having frequency that is an integral multiple of the fundamental power line frequency of 50 H z. The fundamental wave is pure sine wave without distortion. The 2nd harmonic differs in frequency and amplitude from the fundamental wave. It has two times the frequency and half the amplitude. The 3 rd harmonic has three times amplitude of the fundamental And so on. Fig. 6.1.1 depicts the fundamental, 2nd and 3rd harmonic. applications which can operate smoothly over the full speed range, can generate full torque at zero speed, and is capable of fast acceleration and deceleration but that is becoming increasingly attractive for lower performance applications as well due to FOC's motor size, cost and power consumption reduction superiority. Not only is FOC very common in induction motor control applications due to its traditional superiority in high-performance applications, but the expectation is that it will eventually nearly universally displace single-variable scalar volts-per-hertz (V/f) control. Since any periodic waveform f(t) can be expressed as a Fourier series, it follows that the sum of the fundamental, the second harmonic, and so on, must produce the waveform f(t). Generally, the sum of two or more sinusoids of different frequencies produces a waveform that is not a sinusoid The most commonly used index for measuring the harmonic content of a waveform is the total harmonic distortion (THD). It is a measure of the effective value of a waveform and may be applied to either voltage or current. Total harmonic distortion is the contribution of all the harmonic frequency currents to the fundamental. Just as waveforms can be added to produce distorted waves, distorted waves may be decomposed into fundamental and harmonic components. Total Current Harmonic Distortion (THDi) The THDi is a measure of the effective value of the harmonic components of a distorted waveform. This index can be calculated for either voltage or current. The following equation gives THD for current. where P i is the rms value of harmonic component I of the current. IV. VECTOR CONTROL It is also called field-oriented control (FOC), is a variable frequency drive (VFD) control method which controls three-phase AC electric motor output by means of three controllable VFD inverter output variables: Voltage magnitude, Voltage angle, Frequency. FOC is a control technique used in AC synchronous and induction motor applications that was originally developed for high-performance motor V. INDUCTION MOTOR OPERATION An induction motor (1M) is only a part of an adjustable speed drive assembly. As such the 1M is fed from power electronics converter (PEC), but indirectly in most cases from the industrial power grid. Based on the JxB force principle, three operation modes of 1M are easily identified (with Us - ideal noload speed, U - mover speed): Motoring: lui < I US I; U and Us either positive or negative. Generating: lui > IUs I; U and Us either positive or negative. Braking: (U>O & Us <0) or (U<O & Us >0). The basic principle of vector control is to separate the components of stator current responsible for production of flux and the torque. The vector control is obtained by the magnitude, frequency and the phase of the stator current by inverter control. Since the control is obtained by controlling both phase angle and magnitude of current this method of control is called vector control. The main objective of vector control is to achieve superior performance under torque and speed change. For vector control of induction motor its model is considered in a synchronously rotating d-q reference frame. VI. SIMULATION An adjustable speed drive consists of rectifier and inverter. Its functioning depends on the joint action of the rectifier and the inverter. 11

1) Rectifier The rectifier is a six pulse full-wave diode bridge rectifier (p=6), It is represented in the form of a universal bridge in the simulation circuit shown in Fig. 6.1. It converts the power supply ac voltage into dc voltage with a certain ripple. Traditional modeling for controlled rectifiers is a time-delay element in the s-domain. Rectified dc voltage has mean voltage slightly less than peak line voltage due to voltage drops in the power switches and ripple frequency of 300 Hz. To reduce the THD of the input current, the main obstacles are the gaps in the input current, present during the time intervals when the phase voltage of the considered phase is neither minimal nor maximal among the phase voltages, causing both the diodes connected to that phase to be reverse biased. Fig 6.1 Matlab simulink of PWM induction motor 50 0 2) DC link The DC link is commonly called DC bus The diodes in the rectifier convert the input sinusoidal ac voltage to a rectified dc voltage which is then smoothed by the dc link in order to produce a dc voltage with lower ripple. It also acts as energy reserve to supply the inverter when the supply fails. ASD immunity against disturbances therefore depends on the energy stored in this circuit and energy demanded by the load. In Fig. 6.2 dc link is represented with an inductance L and a shunt capacitance C. Representation of the DC link filter is essential for the correct simulation of ASDs. It is the filter that makes the ASD harmonic current waveforms different from those of the DC drives. 3) Inverter The inverter is controlled by the PWM scheme. In a sampling interval T= 11 f C, the pulse width angle can be changed only once. Therefore the PWM inverter is working in discrete state. The purpose of the inverter is to convert the low ripple dc voltage to adjustable ac voltage to allow the speed control of an induction motor. The purpose of the inverter is to convert the low ripple dc voltage to adjustable ac voltage to allow the speed control of an induction motor. The PWM inverter cannot be considered only as a proportional element. Since its output voltage is out of control once the pulse width is applied, it should be looked as a sample and linear-varying element. -50 0 0.2 0.4 0.6 0.8 1 Time Fig 6.1.1 Waveforms of harmonic component Fig 6.2 Matlab simulink by Vector control method Fig 6.2.1 Waveforms of reduced harmonic component by vector control Mathematical Equations Ψ rd =L m i sd /1+sT r Where L m =Mutual inductance 12

Where I a =i m sinwt I b =i m sin(wt-120) I c =i m sin(wt-240) I sd =direct axis stator current s =Laplace Transform T r =Rotor Time costant, L r /R r Tm =3/2L m /Lrz p Ψ rd i sq L r = Rotor resistance Z p =number of pole pairs I sq = quadrature axis stator current T m = motor torque These are the instantaneous values of three phase stator currents displaced by 120 degree each Now these three phases can be converted into stationery d-q axis by using the formula the speed of an induction motor viz, V/f control, FOC, Direct torque control Here my purpose is to reduce the harmonic current by using the vector control method or it is also known as Field oriented control of induction motor. In this method we separate the component of stator currents, d and q, so that the direct axis component is responsible for controlling the rotor flux and quadrature axis component is responsible for controlling the torque. For applying this method, one has to transform abc (three phase stator currents) to rotating axis d-q frame. A speed controller is also used so that it compares the rotor speed to the reference speed. This block can be obtained from electric drives library in sim power systems. Again the power grid ac voltage is converted to dc and then again to ac by the use of rectifier and inverter and finally fed to the induction motor. Rotor flux can be controlled by stator direct axis current and rotor torque can be controlled by the quadrature axis stator current. We will get function fcn in user defined library which is given by 5.6e-4*u^2 and therefore the value of K can be given by 5.6 *10-4 Nominal torque of the motor is given by 19.8778Nm (P/w) The rating of the given motor is 5Hp, 415V,60Hz, 4 pole machine This speed is once again given to the motor (squirrel cage induction motor), we are using machine measurement demultiplexer to get the values of stator three phase currents, electromagnetic torque, rotor speed and getting the result on the scope connected. I have used various voltage and current measurement to know the values of voltages and current supplied from power grid to the adjustable drive for getting the harmonic free voltage to be fed to asynchronous motor, I am converting ac to dc firstly by the use of universal bridge and then converting dc to ac which is to be fed to the Induction motor Phase PWM Inverter (%) Vector Control (%) A 20.89 1.29 B 21.40 1.40 C 23.77 1.30 Table 6.1 Vector controlled ASD By evaluation of the harmonic distortion spectra of PWM inverter fed ASD and Vector controlled ASD it is clear that harmonic distortion is very less in vector control as compared to PWM scheme. VII. CONCLUSION The issue of power quality has become more apparent due to the ever increasing number of non-linear loads. The low frequency harmonic current produced by these loads can cause damage to the power system equipment. Adjustable speed drive (ASD) is becoming a significant load component for power distribution. Designing of these loads to reduce the problems arising from harmonic pollution is done in this paper. This paper involves simulation of ASD such that power quality is significantly improved by reducing the harmonics to a significant level. For vector control method, I am using AC3(field oriented control of induction motors ) in electrical drives library.there are various methods to control 13

VIII. REFERENCES 1. M.Farhney,"Design Considerations when Applying various ASD topologies to meet H armonic Compilance", Paper No. PCIC - 2010-15 Copyright material IEEE. 2. Mukhtar Ahmed,"High Performance AC drives:modeling, Analysis and Control", Springer Publications, London, 2010. 3. Yu Yu; Yang Zhao;" Harmonic and Interharmonic currents generated by the VSI fed Adjustable Speed Drives", IEEE International Conference IPMEC'09, 2009, pp. 2464-2467. 4. Li Zhang," Power Converter Circuits", Marcel Dekker Inc., New York, 2004. 9. T. Kartik, R.Kameswara Rao Analysis of Effects of Vector Control on Total Current Harmonic Distortion of Adjustable Speed AC Drive,International Conference on Computing, Electronics and Electrical Technologies [ICCEET] 2012 10. Xu, X., et al. 1988. "A Stator Flux Oriented Induction Machine Drive", in Conf. Rec. Power Electronics Specialists, PESC'88, Kyoto, Japan,pp. 870-876. 11. Xu, X., Nowotny, D.W. 1990. "Implementation of Direct Stator Flux Oriented Control on a Versatile DSP Based System", in Conf. Rec. IEEE-IAS Annual Meeting, pp. 437-443 12. Y. S. Wang and L. Wang, Unbalanced switching effects on dynamic performance of an isolated three-phase self-excited generator, Elect.Mach. Power Syst., vol. 29, no. 4, pp. 375 387, Apr.2001. 5. Sumitha Mohan, Henry GCuldner Ralf Briest Henrik Wolf Dresden University of Technology Analysis and control aspects of harmonic distortion in the front-end three phase four-wire PWM boost rectffier EPE 2005 - Ditsdcn 6. Simulation Study of AC Motor Speed Sensorless Vector Control System Based on SVPWM JIN Hui, ZHAO Yue-ling College of Electric Engineering Liaoning University of Technology,Jinzhou, China, 2009 Ninth International Conference on Hybrid Intelligent Systems 7. A Proof of Concept Study of Predictive Current Control for VSI-Driven Asymmetrical DualThree-Phase AC Machines Federico Barrero, Senior Member, IEEE, Manuel R. Arahal, Member, IEEE, 8. Pulse Multiplication in AC DC Converters for Harmonic Mitigation in Vector- Controlled Induction Motor Drives,Bhim Singh, Senior Member, IEEE, G. Bhuvaneswari, Senior Member, IEEE, 13. Zhao, Y., Lipo, T.A. 1996. "Modeling and Control of a Multi-phase Induction Machine with Structural Unbalance" Part I, in IEEE Trans. Energy Conv., Vol. 11, No. 3, pp. 570-577. 14. R. C. Bansal, T. S. Bhatti, and D. P. Kothari, A novel mathematical modeling of induction generator for reactive power control of isolated hybrid power systems, Int. J. Modeling Simulation, vol. 24, no. 1, pp.1 7, 2004. 15. Vas, P: 1998. "Sensorless Vector and Direct Torque Control",Clarendon Press, Oxford 16. Trzynaldowski, A.M. 1994. "The field Orientation Principle in Control of Induction Motors",Kluwer Academic Publishers, Amsterdam. 17. M.P. Kazmierkowski, A novel vector control scheme for transistor PWM inverterfed induction motordrive,ieeet rans. 14

Onindust.Vol.38, No.1, Feb1991, pp.41-47. 18. J. Soltani, G. Esmaily, Dynamic performance of the self controlled synchronous motor drive system supplied by SPWM and UPWM voltage source inverters ICEE, Tehran, May 1996, pp.311-318. 19. F. Blaschke, The principle of field orientation as applied to the new transvector closed -loop control system for rotating-field machines Siemens Rev, vol. 39, no. 3, pp. 217-220, may1972. 15