TLS-A. Laurel Electronics, Inc. Triple output loop splitter. Connection details and general information

Similar documents
TIM-018 Mk2. London Electronics Limited. Triple output loop splitter. Connection details and general information

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Artistic Licence. Candle-Power CP12. User Guide. Download this user guide by scanning the following QR code: Candle-Power CP12 User Guide Version 4-8

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

4002-ALM USER MANUAL 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

MODEL AT-10 ANALOG TRANSMITTER

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

QUICK TESTER FOR TRANSFORMERS AND CAPACITORS

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

712B. Users Manual. RTD Calibrator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

PRetrans Table of contents

OTO Line SE Signature

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

Installation and Operating Manual

OPTITEMP TT 20 Technical Datasheet

DIN Thermocouple Conditioner MODEL 5M14(V)

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

This section is specifically about safety matters

Installation instructions

RM3-IV-LPI. 4-20mA Loop Powered Signal Isolators ma & DC Volts Inputs Operation and Instruction Manual

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

Series BDF for Process

HAWK5000 Operators Manual

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

TA MHz oscilloscope probe TA MHz oscilloscope probe

DATA SHEET Selectable AC transducer TAS-311DG

Instruction Manual Model Upconverter

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

LT3000 ULTRASONIC LEVEL TRANSMITTER

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

2002-ALM USER MANUAL

Series P. Applications

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

HUMITRAN-RHT & RH RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER RELATIVE HUMIDITY TRANSMITTER

Heiland electronic GmbH TD / TD1 / TD2. B&W-Densitometers. USERS MANUAL Version 5

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Power Supplies 3. SDN-C Compact DIN Rail Series

USER'S MANUAL DMR-6700

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply.

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

Instruction Manual Model Upconverter

ULT-DIN O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs

Model Number Structure

User Instructions. Model PS-2001L. Power Supply. Model SPS Power Supply. Audiocom Intercom Systems Rev. A, 4/2001.

WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D Herxheim Tel. (07276) FAX 6978

USER'S MANUAL DMR-2400

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

712C. Users Manual. RTD Calibrator

P5201 Universal Programmable Transmitters with Galvanic Isolation

Earth 2/3 MI 2126 Instruction Manual Version 1.0, Code No

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu

LIGHT TRANSMITTER OPERATION MANUAL. 4 to 20 ma. Model : TR-LXT1A4

ULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

INSTALLATION WARNING: BEFORE COMMENCING INSTALLATION ISOLATE YOUR MAINS ELECTRIC SUPPLY

PRODUCT SAFETY SOLUTIONS MODEL HWI-01. Model HWI-01 Serial Number:

GAKU-ON MONO POWER AMPLIFIERS OWNER S INFORMATION

USER'S MANUAL DMR-4350

7006 Loop Mate 1 Loop / Voltage / Current Simulator

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

MINI MCR-SL-UI-I-LP-NC

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

Process displays For standard signals, temperature, resistance measurement

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

QFM21... Duct sensors. Symaro. for relative humidity and temperature

RMO500 M I C R O O H M M E T E R

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Worldwide Manufacturer of Gas Detection Solutions. Transmitter EC 23. Operation Manual

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

AC MASTER Switch mode sine wave inverter

QPM Series Indoor Air Quality Duct Sensors

T L Audio CRIMSON SERIES. User Manual EQ-3012 PARAMETRIC EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

Industrial Serie +600S

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

INSTRUCTION MANUAL LKG

OPERATING INSTRUCTIONS

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

ALM42 ALM46 ALM48 ALM43

PHV RO High Voltage Passive Probe. Instruction Manual

Ricochet Alphasonic Level Transmitter Model LA15 Owner s Manual

AUG / 99 P S I P M E

Transcription:

Laurel Electronics, Inc. 3183-G Airway Avenue, Costa Mesa, CA 92626 Tel 714 434-6131 Fax 714 434-3766 www.laurels.com Triple output loop splitter TLS-A Connection details and general information 1 2 3 4 5 6 7 8 TIM018 Mk 2 S1 Z1 S2 Z2 S3 Z3 Loop splitter 9 10 11 12 13 14 15 16 Revision 0 Dated: 29 Oct 2007 1

2

Alphabetic Index Block diagram page 8 Connections Input 4-20mA active source page 9 Input 4-20mA 2 wire source page 10 Input 4-20mA 3 wire source page 11 Outputs 4-20mA page 14 Power supply - 95-265 VAC page 12 Power supply - 11-30 VDC page 13 Calibration of each output page 15 Dimensions and weights page6 Introduction page 4 Mounting and removal page 7 Specifications page 16 Warnings page 5 3

Introduction Please contact us if you need help, if you have a complaint, or if you have suggestions to help us improve our products or services for you. If you contact us about a product you already have, please tell us the full model number, serial number, and software version, so that we can give you accurate and fast help. You can check the software version when you first switch on the transmitter. The power LED will blink in 2 groups of flashes. Count the flashes in the 1st group and then in the second group. If you see 1 flash in the 1st group and 3 in the second group, the software version is 1.3 This product has a 2 year warranty. We will put right or replace any item which is faulty because of bad workmanship or materials. This warranty does not cover damage caused by misuse or accident. IMPORTANT If this equipment is important to your process, you may want to buy a spare to cover possible failure or accidental damage in the future. This is because at some times, for example during our factory shutdown periods, you may have to to wait several weeks for an equivalent replacement. Or, we may have no stock at the time you urgently need it. You may also need to pay extra shipping charges if you want a fast, guaranteed courier service. Warranty repairs or replacements are normally returned with a standard courier service. We do not offer any compensation for losses caused by failure of this instrument. If you do not agree with these conditions, please return this item now, in unused, clean condition, in its original packaging and we will refund the purchase price, excluding any carriage paid. We thought you d prefer to know about possible delays and extra charges now, rather than during a panic. We always try to improve our products and services, so these may change over time. You should keep this manual safely, because future manuals, for new designs, may not describe this product accurately. We believe these instructions are accurate, and that we have competently designed and manufactured the product, but please let us know if you find any errors. 4

! Warnings Please carefully read all warnings and ONLY install the item when you are sure that you ve covered all aspects. * Connect the equipment according to current IEE regulations and separate all wiring according to IEC1010. * Power supplies to this equipment must have anti-surge (T) fuses rated at 250mA for AC supply or 1A for DC supplies in the range 11-30VDC. * Check that the model number and supply voltage suit your application before you install the equipment. * Don t touch any circuitry after you have connected the equipment, because there may be lethal voltages on the circuit board or connector terminals. * We designed this equipment for Pollution-Degree 2 environments only. This means you must install it in a clean, dry environment. * Only adjust on-board switches or connections with the power turned off. * Make sure all screw terminals are tight before you switch the equipment on. * Only clean the equipment with a soft dry lint-free cloth. Do not use any solvents. Safety First...Don't assume anything... Always double check. If in doubt, ask someone who is QUALIFIED to help you in the subject. 5

Dimensions and weights Case (stacking) width : 22.5 mm Case forward projection : 111.0 mm Case height : 99.0 mm Typical transmitter weight : 200 grams Operating conditions : 0 to 50 degrees C, 10 to 90%rh non-condensing Storage conditions : -20 to +70 degrees C, 10 to 90%rh non condensing Case sealing : IP40 Case Material : Polyamide PA 6.6 Cable dimensions : Accepts multistrand wires total area from 1mm 2 to 4mm 2 Flammability Class : V0 (UL94) 99 mm 111 mm 6

DIN rail mounting & removal The TLS-A mounts simply and quickly onto DIN rail in accordance with EN 60 715. Simply clip the housing onto the rail. To prevent side to side movement, you may also wish to add end-stops, which we can supply as a pair. Ask for accessory XSTOP for plastic end-stops or XEARTH for metal stops with earthing terminal. Cooling: Single splitters are rated for use in still air at 0 to 50 degreesc. However, as you stack units together, they will gain heat, which you must remove with forced air ventilation. 1 unit, natural ventilation 0-50C 2 units, natural ventilation 0-40C 3 or more units, natural ventilation 0-35C Any number of units, ventilated with air from underneath at >0.5ms -1 0-50 C Use a crossflow or tangential blower To remove a module, place the tip of a 3mm terminal screwdriver in the slotted metal clip at the base. Pull the clip downwards, and lift the module off the rail. 7

Block diagram O/P3 - O/P3 + O/P1 - O/P1 + O/P2 - O/P2 + Span 1 Zero PSU with isolation Span Zero 2 Span 3 Zero Isolation Transformer wide range switchmode power supply I/P - I/P + Excitation + Earth Power Power 8

4-20mA Input - Active source Where to connect 4-20mA input if the input does not need excitation Notes: Terminal 9 = Signal - Terminal 10 = Signal + Terminal 11 = not used Terminal 12 = Excitation + Excitation voltage is 20V DC +/-10% Maximum current 30mA Input resistance 50 Ohms - + 4-20mA input from an active source 9

4-20mA Input - 2 wire source Where to connect 4-20mA input if the input comes from a 2 wire transmitter Notes: Terminal 9 = not used Terminal 10 = Signal + Terminal 11 = not used Terminal 12 = Excitation + Excitation voltage is 20V DC +/-10% Maximum current 30mA Input resistance 50 Ohms - + 2 wire transmitter Typical device 10

4-20mA Input - 3 wire source Where to connect 4-20mA input if the input comes from a 3 wire transmitter Notes: Terminal 9 = Signal - Terminal 10 = Signal + Terminal 11 = not used Terminal 12 = Excitation + Excitation voltage is 20V DC +/-10% Maximum current 30mA Input resistance 50 Ohms Com Sig +V Typical device 3 wire transmitter 11

AC Power Where to connect AC power to your loop splitter First check the voltage rating on the silver label on the side of the loop splitter. It MUST say 95-265 VAC if you want to power your transmitter from an AC supply. DO NOT connect AC Power if the Voltage rating is 11-30 VDC INT-X-Series 4-20mA 0-10V Notes: Terminal 13 = Earth / Ground Terminal 14 = no connection Terminal 15 = Line / AC Hi Terminal 16 = Neutral / AC Lo There is a 160mA fuse in the splitter. You must fuse your power circuit 250mA. Earth ~ ~ 12

DC Power Where to connect DC power to your loop splitter First check the voltage rating on the silver label on the side of the loop splitter. It must say 11-30 VDC if you want to power your transmitter from a DC supply Notes: Terminal 13 = Earth / Ground Terminal 14 = no connection Terminal 15 = Positive Terminal 16 = Negative There is a 2A fuse in the splitter. You must fuse your power circuit 1A INT-X-Series 4-20mA 0-10V Earth + - 13

4-20mA outputs Where to connect 4-20ma outputs Use screened twisted pair data cable. Keep data cable away from power cabling and noise to reduce interference to the data. Terminal 4 is connected to terminal 6 and terminal 8 inside the splitter. O/P 1 O/P 3 - + O/P 2 - + - + Notes: Terminal 1 = not used Terminal 2 = not used Terminal 3 = O/P 3 - Terminal 4 = O/P 3 + Terminal 5 = O/P 1 - Terminal 6 = O/P 1+ Terminal 7 = O/P 2 - Terminal 8 = O/P 2+ Outputs can drive into 600 Ohms max. at 20mA All + outputs are commoned and are at the same potential as Excitation + 14

Calibration of each output. 1) Apply power, and leave the loop splitter running for a few minutes before commencing calibration. 2) Apply 4 ma to the input, and measure O/P 1. Adjust its zero pot to obtain 4mA output. 3) Apply 20 ma to the input and measure O/P 1. Adjust its span pot to obtain 20 ma output. 4) Repeat steps 2) & 3) until no further adjustment is needed. 5) Apply 12mA and check that the output is 12mA also. 6) Repeat steps 2 to 5 until no further adjustment is necessary, and then repeat the same procedure for outputs 2 and 3. 15

Specifications Input Signal... Input Resistance... Resolution... Open Circuit Input Response... Speed of Response... Accuracy... Temperature stability... 4-20mA 50 Ohms infinite Downscale Drive < 100 ms +/- 0.1% of span 100 ppm of range/c span and zero Outputs Number of output channels... 3 Loop drive capacity... 600 Ohms per loop at 20mA Span adjustability... +/- 9 ma at 20 ma input Zero adjustability... +/- 1 ma at 4 ma input Influence between outputs... Minimal. Any load conditions on one O/P has negligible effect on others Ajustment location... On front face of transmitter, via access slot Isolation... Isolated from ground, but not from input Excitation Supply... 20 VDC nominal +/- 10% Current Capacity... 30mA max. permissible load Power Supply AC Supply... Current Consumption... Mechanical Base size... Forward projection... Weight... Environmental Operating Temperature... Storage Temperature... Humidity... 95-265 VAC as standard. 11-30VDC optional Allow 3VA if excitation supply fully loaded. 22.5 mm wide by 99 mm high 111 mm 220 grammes 0 to +50 degrees C -20 to +70 degrees C 10 to 90% rh max. at 40 C, non condensing. 16