Measuring Vgs on Wide Bandgap Semiconductors APPLICATION NOTE

Similar documents
Isolation Addresses Common Sources of Differential Measurement Error

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

Simplifying DC-DC Converter Characterization using a 2600B System SourceMeter SMU Instrument and MSO/DPO5000 or DPO7000 Series Scope APPLICATION NOTE

Verifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE

Performing Safe Operating Area Analysis on MOSFETs and Other Switching Devices with an Oscilloscope APPLICATION NOTE

Simplifying FET Testing with 2600B System SourceMeter SMU Instruments APPLICATION NOTE

Using the Model 4225-RPM Remote Amplifier/ Switch to Automate Switching Between DC I-V, C-V, and Pulsed I-V Measurements APPLICATION NOTE

Debugging SENT Automotive Buses with an Oscilloscope APPLICATION NOTE

KickStart Instrument Control Software Datasheet

Power Analysis Application Module DPO4PWR MDO3PWR Datasheet

20X Low Capacitance Probe P6158 Datasheet

SOURCE MEASURE UNITS. Make Multiple Measurements Accurately Using a Single Instrument All While Saving Space, Time and Money

Trouble-shooting Radio Links in Unlicensed Frequency Bands TUTORIAL

Using the Ramp Rate Method for Making Quasistatic C-V Measurements with the 4200A-SCS Parameter Analyzer APPLICATION NOTE

Switching Between C-V and I-V Measurements Using the 4200A-CVIV Multi-Switch and 4200A-SCS Parameter Analyzer APPLICATION NOTE

P7500 Series Probes Tip Selection, Rework and Soldering Guide

Don t Let EMI/EMC Compliance Certification Slow You Down TUTORIAL

In-circuit Measurements of Inductors and Transformers in Switch Mode Power Supplies APPLICATION NOTE

Measuring Power Supply Switching Loss with an Oscilloscope

io n Data Sheet or The P5205 is a 100 MHz Active Differential Probe capable of measuring fast rise times of signals in floating circuits. This 1,300 V

Power Measurement and Analysis Software

Sophisticated Power Loss Analysis Using A Digital Phosphor Oscilloscope

Using the 4200A-CVIV Multi-Switch to Make High Voltage and High Current C-V Measurements APPLICATION NOTE

Active Power Factor Correction Verification Measurements with an Oscilloscope APPLICATION NOTE

High-voltage Differential Probes

Soldering a P7500 to a Nexus DDR Component Interposer

Passive High Voltage Probes P5100A-TPP0850-P5122-P5150-P6015A Datasheet

1.5 GHz Active Probe TAP1500 Datasheet

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Passive Voltage Probes

Low Capacitance Probes Minimize Impact on Circuit Operation

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

S540 Power Semiconductor Test System Datasheet

12.5 Gb/s PatternPro Programmable Pattern Generator PPG1251 Series Datasheet

Stress Calibration for Jitter >1UI A Practical Method

Ethernet Transmitter Test Application Software TekExpress 10GBASE-T and NBASE-T Datasheet

10 GHz Linear Amplifier PSPL5866 Datasheet

12.5 Gb/s PatternPro Programmable Pattern Generator PPG1251 Series Datasheet

S540 Power Semiconductor Test System Datasheet

30 A AC/DC Current Probe TCP0030A Datasheet

Differential Probes P6248 P6247 P6246 Datasheet

AC Current Probes CT1 CT2 CT6 Data Sheet

Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet

LE160 LE320 Linear Equalizer Datasheet Tektronix Linear Equalizer

100GBASE-KR4/CR4 & CAUI-4 Compliance and Characterization Solution

Measuring Wireless Power Charging Systems for Portable Electronics

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

AC/DC Current Probe TCP0150 Datasheet

Tire Pressure Monitoring Systems and Remote/Passive Keyless Entry

100GBASE-KR4, 100GBASE-CR4, & CAUI-4 Compliance and Characterization Solution for Real Time Scopes

12.5 Gb/s Driver Amplifier PSPL5865 Datasheet

Measurement Statistics, Histograms and Trend Plot Analysis Modes

TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM TCA292D Datasheet

Fundamentals of AC Power Measurements

Tektronix Logic Analyzer Probes P6800/P6900 Series Datasheet

TriMode Probe Family P7700 Series TriMode Probes

P7600 Series TriMode Probes

Be Sure to Capture the Complete Picture

Automotive EMI/EMC Pre-compliance Tests

DPO7OE1 33 GHz Optical Probe

16 Gb/s, 30 Gb/s, and 32 Gb/s PatternPro Pattern Generator PPG1600, PPG3000, and PPG3200 Series Datasheet Notice to EU customers

Visual Triggering. Technical Brief

16 Gb/s, 30 Gb/s Gb/s, and 32 Gb/s Programmable PatternPro Pattern Generator PPG PPG1600, PPG3000, and PPG3200 Series Datasheet Key features

Advanced Power Measurement and Analysis 5 Series MSO Option 5-PWR Datasheet

30 Gb/s and 32 Gb/s Programmable Pattern Generator PPG Series Datasheet

Low Cost RF Sensors. application note

Advanced Test Equipment Rentals ATEC (2832)

High-impedance Buffer Amplifier System

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

16 Gb/s, 30 Gb/s, and 32 Gb/s PatternPro Pattern Generator PPG1600, PPG3000, and PPG3200 Series Datasheet Key features

Time and Frequency Measurements for Oscillator Manufacturers

Replicating Real World Signals with an Arbitrary/Function Generator

Programmable Pulse/Pattern Generator PSPL1P601 and PSPL1P602 Datasheet

Z-Active Differential Probe Family P7313 P7380A P7360A P7340A Datasheet

Choosing an Oscilloscope for Coherent Optical Modulation Analysis

Passive High Voltage Probes P5100 P5102 P5120 P6015A

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

van der Pauw and Hall Voltage Measurements with the 4200A-SCS Parameter Analyzer APPLICATION NOTE

OM2210 Coherent Receiver Calibration Source OM2210 Datasheet

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

TriMode Probe Family. P7500 Series Data Sheet. Features & Benefits. Applications

46 GBaud Multi-Format Optical Transmitter OM5110 Datasheet

If I Could... Imagine Perfect Vision

TriMode Probe Family. P7500 Series Datasheet. Features & Benefits. Applications

How to Troubleshoot System Problems Using an Oscilloscope with I 2 C and SPI Decoding

10GBASE-KR/KR4 Compliance and Debug Solution

Creating Calibrated UWB WiMedia Signals

GENERAL PURPOSE POWER SUPPLIES, SPECIAL PURPOSE POWER SUPPLIES, AND ELECTRONIC LOADS SELECTOR GUIDE

Making Accurate Current Measurements on Power Supplies with Oscilloscopes APPLICATION NOTE

AC/DC Current Measurement Systems

Advanced Statistical Analysis Using Waveform Database Acquisition

Overcoming RF Signal Generation Challenges with New DAC Technologies WHITE PAPER

Introduction to VNA Basics PRIMER

Frame through-beam sensors

Basics of Using the NetTek YBA250

Understanding AWG70000A Series Frequency Response and DAC Performance

50MHz arbitrary waveform/function generator

CISCO ONS /100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM

Performing Cyclic Voltammetry Measurements Using Model 2450-EC or 2460-EC Electrochemistry Lab System

Through-beam ring sensors

Transcription:

Measuring Vgs on Wide Bandgap Semiconductors

This application note focuses on accurate high-side V GS measurements using the IsoVu measurement system. The measurements described in this application note are shown on a half-bridge configuration with egan FETs on both the high-side and low-side switches. While high-side gate measurements are the focus of this application note, the lowside gate will also be examined. This application note addresses measurements during the following events: 1. High-side Turn-on 2. Hide-side Turn-off / Low-side Turn-on Introduction Components used in topologies such as the half-bridge have greatly evolved leading to advancements in efficiencies, densities, and reliability. An example half-bridge configuration is shown in Figure 1. The advancement of power conversion components and more stringent design requirements have far outpaced the ability to accurately measure and characterize these designs. At present, there is no test and measurement equipment capable of accurately making measurements such as the high-side gate-source voltage. In fact, most differential signals in the presence of today s higher frequency common mode voltages cannot be measured accurately. To make sense of what is happening in these environments, users have been forced to use alternative methods such as extensive simulation, measuring the low-side ( ground referenced) switch and inferring the results to the high-side switch, examining thermal characteristics, EMI proximity probing, or trial and error methods. The benefits of a design such as a half-bridge circuit can only be achieved when the half-bridge circuit, the gate drive circuit, and layout, are all properly designed and optimized. It s impossible to tune and optimize this circuit if you cannot measure it. Completing this design requirement involves characterizing the waveforms shown in the ideal case in Figure 2. FIGURE 1. Half-Bridge Configuration. FIGURE 2. Example Ideal Half-Bridge Switching Waveforms. 2 WWW.TEK.COM

FIGURE 3. High-Side Turn On Characteristics. 1. High-side Turn-on Characteristics In general there are three characteristic regions of the turn on waveform that are of interest. The first region is the C GS charge time. This is followed by the Miller Plateau which is the time required to charge the gate-drain Miller capacitance (C GD ), and is V DS dependent. This charge time increases as V DS increases. Once the channel is in conduction, the gate will charge up to its final value. The ideal representation of these regions is shown in Figure 3. The high-side V GS is riding on top of the switch node voltage which is switching between ground and the input supply voltage. Because of this rapidly changing common mode voltage, the gate-source voltage is impossible to measure without adequate common mode rejection. WWW.TEK.COM 3

FIGURE 4. Comparison of LeCroy s DA1855A High-Side V GS Output to Ideal. FIGURE 5. Comparison of the Tektronix IsoVu High-Side V GS Output to Ideal. You may have tried making the high-side V GS measurement and gotten a waveform similar to the output of the DA1855A on a LeCroy scope shown in Figure 4. Comparing this actual output to the ideal transition, it s difficult to extract any meaningful details regarding what is happening in each of the regions referenced above and make design decisions based on this measurement. It s worth noting that the waveform shown below changes dramatically based upon position of the probe s input leads making a repeatable measurement impossible. However, the IsoVu measurement system shows the details of what is occurring in the design and the measurement is stable and repeatable. This waveform clearly shows resonances and signal details previously hidden. 4 WWW.TEK.COM

Until now, the LeCroy DA1855A with a 12-bit oscilloscope has offered the most insight into these kinds of measurements. With this measurement system, the user may have been tempted to optimize their design based on the waveform information. After all, it does seem to show some of the expected characteristics. However, the IsoVu system tells a very different story. Figure 6 shows a comparison of these two measurement systems and reveals how optimizing based on a measurement system with limited CMRR and bandwidth can cause users to severely mis-tune their design. FIGURE 6. Comparison of Waveforms on a LeCroy Oscilloscope with IsoVu Waveform Overlaid. IsoVu offers users the resolution and repeatability required to optimize the performance of their designs. As you can see in Figure 7, there is clear correlation between the Miller plateau and the switch node transition. FIGURE 7. High-Side V GS Turn On and Switch Node Compared to Ideal. Although the low-side switch is supposed to be ground referenced, it s interesting to see the actual waveform and how it may affect the high-side performance. Figure 8 shows that the low-side switch has ringing due to parasitic coupling between the low-side switch, the high-side gate and the switch node. FIGURE 8. Interaction of the High-Side and Low-side Switches. WWW.TEK.COM 5

FIGURE 9. High-Side Turn Off, Low-Side Turn On, and Dead Time. 2. High-side Turn-off / Low-side Turn-on Characteristics Many of the same characteristics are apparent during the high-side turn-off/low-side turn on transitions. As shown in Figure 9, the Miller plateau on the low-side V GS is clearly visible. The coupling due to parasitics between the switch node and the high and low-side FETs is apparent, and the IsoVu measurement system has more than adequate bandwidth to measure the dead time. Accurate measurement of the time aligned high-side and lowside events is critical to avoid simultaneous conduction of the two FETs which can lead to excess switch loss, efficiency loss and device degradation. Conclusion To accurately make difficult measurements such as the highside V GS measurement, you need a measurement system which combines high bandwidth, high common mode voltage, and high common mode rejection. Along with its complete galvanic isolation, the Tektronix IsoVu system offers 1 GHz bandwidth, 2000 V common mode voltage and 1 Million to 1 (120 db) common mode rejection ratio. It s the combination of these specifications which makes these kinds of difficult measurements possible. 6 WWW.TEK.COM

WWW.TEK.COM 7

Contact Information: Australia* 1 800 709 465 Austria 00800 2255 4835 Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium* 00800 2255 4835 Brazil +55 (11) 3759 7627 Canada 1 800 833 9200 Central East Europe / Baltics +41 52 675 3777 Central Europe / Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France* 00800 2255 4835 Germany* 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Indonesia 007 803 601 5249 Italy 00800 2255 4835 Japan 81 (3) 6714 3010 Luxembourg +41 52 675 3777 Malaysia 1 800 22 55835 Mexico, Central/South America and Caribbean 52 (55) 56 04 50 90 Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands* 00800 2255 4835 New Zealand 0800 800 238 Norway 800 16098 People s Republic of China 400 820 5835 Philippines 1 800 1601 0077 Poland +41 52 675 3777 Portugal 80 08 12370 Republic of Korea +82 2 6917 5000 Russia / CIS +7 (495) 6647564 Singapore 800 6011 473 South Africa +41 52 675 3777 Spain* 00800 2255 4835 Sweden* 00800 2255 4835 Switzerland* 00800 2255 4835 Taiwan 886 (2) 2656 6688 Thailand 1 800 011 931 United Kingdom / Ireland* 00800 2255 4835 USA 1 800 833 9200 Vietnam 12060128 * European toll-free number. If not accessible, call: +41 52 675 3777 Find more valuable resources at TEK.COM Copyright Tektronix. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies. 07.16 EA 53W-60779-0