LIGHT INTENSITY METER

Similar documents
USER GUIDE. White LED Light Meter. Model LT Washington Street Melrose, MA Phone Toll Free

USER MANUAL. LUX/FC Light Meter. Model LT505. Additional User Manual Translations available at

netzerotools.com USER GUIDE Extech LT40 LED Light Meter Extech LT45 Color LED Light Meter LED Light Meter Model LT45 netzerotools.

Model ST Instruction Manual. Light Meter. reedinstruments www.

INSTRUCTION MANUAL MODEL 8820 Multi-Function Environment Meter

DIGITAL ILLUMINANCE METER MODEL 1308 INSTRUCTION MANUL

User's Guide. EasyView Light Meter with Memory. Model EA33. Introduction

LUX/FC LED Light Meter TM-201L / TM-209 User s manual

LUX/FC LED Light Meter TM-201L / TM-209/TM-209N /TM-209M

EasyView Light Meter with Memory

Digital Multimeter, Pen Type

INSTRUCTION MANUAL PCE-222

INSTRUCTION MANUAL MODEL 21 MULTI-TESTER

Manual DATALOGGING LIGHT METER - PCE-174

RF/High Frequency Meter HF-A3G

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Model Digital Light Meter

AUTO-SCAN Pen R/C/D Meter for SMD AX-507B USER S MANUAL

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL DLM2

User Guide. EasyView Digital Light Meter. Model EA31

OPERATOR S INSTRUCTION MANUAL

DIGITAL MULTIMETER OPERATOR S MANUAL

DIGITAL LIGHT METER TES-1337 INSTRUCTION MANUAL CONTENTS

USER MANUAL. UV AB Light Meter. Model UV505. Additional User Manual Translations available at

INSTRUCTION MANUAL LM195 LED LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

Advanced Test Equipment Rentals ATEC (2832)

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

Heavy Duty Meter Model

Digital Multi Meter OPERATING INSTRUCTION. Table of Contents

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

DIGITAL MULTIMETER INSTRUCTION MANUAL

Printing Humidity/Temperature Meter

Model. Instruction Manual. Digital ph Pen. reedinstruments. REED Instruments

INSTRUCTION MANUAL LM192 LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

EM5. Multifunctional Environmental Meter. Sealed Unit Parts Co., Inc. User Manual

AMM-1022 Digital Multimeter USER`S MANUAL

Magnetic Field Meter EM-191

CONTENTS MS2033A. 1.Introduction Safety Information...01

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

Pen-type DIGITAL MULTITESTER

Multifunction Digital

User Guide. Digital AC/DC Clamp Meter Model 38394

ET-3888 True RMS Clamp Meter. User Manual

User s Guide. Digital AC/DC Clamp Meter Model 38394

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

2,000 counts, 200 Amp ACA/DCA, 600 V ACV/DCV, True RMS, OHMS, Continuity, Hold, Peak Hold FORK CURRENT TESTER. Model : FT-9950

User Manual Digital Clamp Multimeter. model no.: MSR-C600

Microwave Meter. Instruction Manual

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

AMМ-3320 Multi-function LCR USER`S MANUAL

Read and be familiar with this manual before operating or servicing this device. To ensure operator, technician, and patient safety, use only as

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

True RMS. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, REL, Capacitance Hz, Duty, ACV, ACA, DCV, DCA, Ohms

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

0.01kV (0 to ±0.99 kv)

3423 LUX HiTESTER INSTRUCTION MANUAL

Table of Content. The Statement Safety Statement Safety Instructions Safety Operation Specifications Safety Symbols...

DVM1190 DIGITAL MULTIMETER

LCR METER Model:

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

POWER ANALYZER OPERATION MANUAL. Model : DW-6090A

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

Analog Technologies VC99. Multimeter FEATURES

Model UT233 OPERATING MANUAL

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

Model UT511 OPERATING MANUAL

NOTE: Fully read and understand this manual before using this Digital Multimeter.

MULTIMETRE DIGITAL 3 3/4 AVEC ECHELLE AUTOMATIQUE & EXTINCTION AUTOMATIQUE MANUEL D UTILISATION

TES-1306 DIGITAL THERMOMETER INSTRUCTION MANUAL 1. SAFETY INFORMATION

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

Dawson DSM150. Digital Light Meter User s Manual

USER'S MANUAL DMR-4350

LCR METER Model:

Cat# Multi-functional LED Light Meter

User s Manual. hand-held laser distance meter

multi-function + auto-range, CATIII 1000V ACV/DCV/OHMS/4 to 4000 M ohm, 100V, 250V, 500V, 1000V INSULATION TESTER

4.5 Auto Power Off During use Preparation For Measurement Symbols...3

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Micro-Ohmmeter Model UM200

KMD-S04 Multímetro de bolsillo

DIGITAL MULTIMETER OPERATION MANUAL

2000 A DCA/ACA CLAMP + DMM,

UT232. Operating Manual. Digital Power Clamp Meter

USER'S MANUAL DMR-4300

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / ,

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

USER S MANUAL. 580 TV Line OSD Bullet Camera With 2 External Illuminators

8PK-ST1520 Digital Earth Resistance Tester

VC835 DIGTAL MULTIMETER Operation Manual

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

AC/DC CLAMP METER USER S MANUAL

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

OPERATOR S INSTRUCTION MANUAL

Transcription:

LIGHT INTENSITY METER Users Manual

. Introduction Thank you for purchasing the light intensity meter from us. Please take a few minutes to browse through this user manual before you begin to operate the meter to ensure that you are fully familiarized with how best to operate the meter as accurately and safely as possible. This meter is an illuminance measuring instrument. It is normally used to measure illuminances, e.g.at workplaces. 1.1 Precautions safety measures To get the best service from this meter, please read this user's manual carefully and observe the detailed safety precautions strictly. 1.1.1 During use 1. If the OL symbol will show on the LCD, it means the readings is outside the measuring range. Please keep to the permitted measuring range. 2. Never store the product together with solvents, acides or other aggressive substances. -1-

3. When the battery voltage is under proper operation requirement, the symbol will show on the LCD and the battery need to be replaced with new. 1.1.2 Maintaining the product Do not measure at a high temperature, high humidity places. Keep the light sensor clean. To guarantee correct readings: Hold the instrument horizontally so that the light sensor is directed upwards. When not using the instrument for a long time, please remove the battery and avoid storing in high temperature and high humidity.. Features 1. Display: 6 digits LCD Display 2. Parameters: Lux(lm/m2) foot candle (lm/ft2) 3. Resolution: 1 Lux(0 90000 Lux); 0.1 ftc(0 8300.0 ftc); -2-

4. Range: 0 90000 Lux 0 8300.0 ftc 5. Accuracy: Range Accuracy Environment 0-10000lux ±(4%+50digital) 23 @2856K 10000-90000lux Reference color temperature *If test environment is not at the 2856K color temperature, error will increase. 4000K warm fluorescent lamp:0~10000lux±(10%+200counts) 6000K cold fluorescent lamp:0~10000lux±(10%+200counts) 6. Sample rate: 1 time /sec 7. Auto power off: about 20 minutes 8. Low battery indicator 9. Operating environment: 0 ~ 50 (32 ~122 ),0 ~ 80%RH 10. Storage environment: -20 ~ 60 (-4 ~140 ),0 ~ 80%RH 11. Dimension and Weight: 121(L)x60(W)x30(H)mm, about 180g 12. Accessories: DC1.5V (AAA) x 3pcs String x 1pcs Plastic box x 1pcs Users manual x 1pcs -3-

. Names of parts Instrument Familiarization 1. Sensor cover 2. Light sensor 3. LCD display 4. Function key Unit Func. ON/OFF LCD Display Light intensity meter -4-

The meaning of the symbols represented by the following table Number of Order 1 2 3 Symbol Functions Indicating it is now in the data-holding mode Indicating the display value being the maximum value(max) Indicating the display value being the minimum value(min) 4 Measure values 5 parameter unit 6 parameter unit 7 Indication to the calibration mode -5-

8 Indication low power of batteries. Batteries should be replaced.. Operation instruction 1. Please install new batteries on the meter. 2. Put the meter on the environment to be measured and hold it horizontally so that the light sensor is directed upwards. 3. Press the ON/OFF key to turn the power on. 4. After power on, press the Unit key to select the needed units. 5. When the reading has been stable, read the illumination value. * If you still need more operations, please see the description of keys instruction. -6-

. Keys instruction 1. ON/OFF key Press the key to turn the power ON and press the key once more to turn the power OFF. 2. Func. key Press the key can select the state of MAX MIN HOLD. The cycle of views shows as following figure: Mode key Mode key Measure mode Hold mode Max mode Mode key Min mode Mode key Hold mode: Reading are held. Max mode: Maximum values since the instrument was last switched on or last reset. Min mode: Minimum values since the instrument was last switched on or last reset. -7-

3. Unit key 1) Unit set Press the key can change the parameter unit: lux, ftc. 2) Back light contrl If press the key >2sec. the back light will be turned on, Press the key once >2sec. the light will be turned off. If the back light is not closed within 60 seconds, it will be turned off automatically. 3) Auto power off set When the meter is powered on, it is under auto power off mode. The meter will power itself off after 20 minutes if no key operation. Cancelled auto power off function: press Unit key when power on until the LCD display AP OFF, then press the ON/OFF key to confirm the setting. And then the meter will be power off. -8-

. Reference table of illumination standard Place Illumination - Office Conference Room, 200 ~ 750 Living room Administration 700 ~ 1,500 Typing 1000 ~ 2,000 - Factory Packaging, Access 150 ~ 300 Assembly line 300 ~ 750 Check 750 ~ 1,500 Electronic components 1,500 ~ 3,000 assembly line - Hotel Public places, Lavatory 100 ~ 200 Reception room 200 ~1,000 - Store Staircase, corridor 150 ~ 200 Presentation window, 750 ~ 1,500 Packaging station Shop window 1,500 ~ 3,000 - Hospital -9-

Ward, Warehouse 100 ~ 200 Medical examination 300 ~ 750 room Operating room, 750 ~ 1,500 Emergency Room - School Hall, Indoor stadium, 200 ~ 750 Classroom Laboratory, Library 500 ~ 1,500. Maintenance 1. CLEANING INSTRUCTIONS The meter may be wiped down with a wet sponge or cloth using a mild water based detergent or anti-bacterial soap and rinsed under a gentle stream of cold water. NOTE: This unit is not designed for complete submersion or washing in water. 2. BATTERY REPLACEMENT -10-

Use the following procedure: When the battery voltage drop below proper operation range the symbol will appear on the LCD display and the battery need to be replaced. Press the battery cover and towards arrowhead direction to open the battery cover. Replace the battery with three new 1.5V batteries (AAA). Replace the battery cover. -11- WLS2110