Abridged Data. General Data. MG7095 Tunable S-Band Magnetron for Switched Energy Applications. Cooling. Electrical. Accessories.

Similar documents
MG7095 Tunable S-Band Magnetron

MG5193 Tunable S-Band Magnetron

MG6090 Tunable S-Band Magnetron

MG5223F S-Band Magnetron

MG MW S-Band Magnetron

M5028 Precision Tuned Magnetron

E2V Technologies MG5222 X-Band Magnetron

E2V Technologies MG5223F S-Band Magnetron

E2V Technologies M5187F X-Band Magnetron

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water

X-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

X band Magnetron. Water: Anode cavity Forced-air: Input ceramics and terminals Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

M5187 X-Band Magnetron

E2V Technologies MG6028 Fast Tuned Magnetron

CX1140 Hydrogen Thyratron

S-band 500kW Magnetron

E2V Technologies CX1175C Deuterium-Filled Ceramic Thyratron

E2V Technologies CX1725, CX1725X Liquid Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

ABSOLUTE MAXIMUM RATINGS These ratings cannot necessarily be used simultaneously and no individual ratings should be exceeded.

PET1606J2F. Pilani Electron Tubes & Devices Pvt. Ltd. Water Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1606J2F

PET1610F. Pilani Electron Tubes & Devices Pvt. Ltd. Forced-Air Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1610F

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 8943

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE DOD-011

STA3318 Series StellarMini TM 180 W, Ku-Band Antenna Mount TWTA

Fig.1 Heater dissipation test circuit

CCD42-10 Back Illuminated High Performance AIMO CCD Sensor

CCD47-10 NIMO Back Illuminated Compact Pack High Performance CCD Sensor

8121 Power Tube. Linear Beam Power Tube

CCD30-11 NIMO Back Illuminated Deep Depleted High Performance CCD Sensor

R S / R 100ppb 0.1. Fig. 1: R S /R 0 as a function of gas concentration at 50% RH and 25 C.

CCD97-00 Back Illuminated 2-Phase IMO Series Electron Multiplying CCD Sensor

8988 Power Tube. Linear Beam Power Tube

4665 Power Tube UHF Pulsed Power Amplifier Tube

9007 Power Tube. VHF Linear Power Amplifier Tube 33 Kilowatt Peak Sync Output Thru VHF-TV Band

CCD Back Illuminated 2-Phase IMO Series Electron Multiplying CCD Sensor

Current Probes. User Manual

CCD30-11 Front Illuminated Advanced Inverted Mode High Performance CCD Sensor

Transmitter Triode RS 2041 V YD 1262

Siemens Aktiengesellschaft 137

Siemens Aktiengesellschaft 211

Siemens Aktiengesellschaft 299

Transmitter Tetrode RS 1034

L A B O R A T O R I E S 9740 COZYCROFT AVENUE * CHATSWORTH * CALIFORNIA (800) * (818) * FAX: (818)

MEDIUM-MU AIR-COOLED POWER TRIODE 3CX15,000H3

Power Tube. Beam Power Tube

CCD55-30 Inverted Mode Sensor High Performance CCD Sensor

Transmitter Tetrode TH 347

RADIAL BEAM POWER CPI RADIAL 4CW50,000J BEAM POWER TETRODE 4CX20,000C

MA2709A Thyratron Trigger System

6884 Power Tube. Beam Power Tube

CCD67 Back Illuminated AIMO High Performance Compact Pack CCD Sensor

YC-179 / YC-179A CPI HIGH-MU 4CW50,000J POWER TRIODE YC-179 / YC-179A

90 Siemens Aktiengesellschaft

TECHNIlCAL DATA. Amperes Cathode Heating Time..300

Transmitter Tetrode. Approx. weight 16 kg. 360 Siemens Aktiengesellschaft. ➀ Tube support ➁ Air inlet ➂ Do not use as terminal.

186 Siemens Aktiengesellschaft

CCD30 11 Back Illuminated High Performance CCD Sensor

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Type B

General Data Electrical Heater for Oxide-Coated Unipotential Cathode: Voltage (AC or DC) 26.5 ± 10% Current at 26.5 volts

Model 113 Scintillation Preamplifier Operating and Service Manual

Siemens Aktiengesellschaft 101

CCD42-40 NIMO Back Illuminated High Performance CCD Sensor

CCD47-20 Back Illuminated NIMO High Performance NIMO Back Illuminated CCD Sensor

CCD97 00 Front Illuminated 2-Phase IMO Series Electron Multiplying CCD Sensor

Svetlana 4CX7500A Radial Beam Power Tetrode

CCD42-40 NIMO Back Illuminated High Performance CCD Sensor

8984 Power Tube. VHF Linear Beam Power Tube

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I

Product Information PI

4662 Power Tube. Linear Beam Power Tube

8792 Power Tube. Linear Beam Power Amplifier Tube

Marconi Applied Technologies CCD47-20 High Performance CCD Sensor

E2V Technologies CCD42-80 Back Illuminated High Performance CCD Sensor

HIGH-MU POWER TRIODE 3CW40,000A7

8807 Power Tube. Beam Power Tube

ROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Electrical :

Marconi Applied Technologies CCD30-11 Inverted Mode Sensor High Performance CCD Sensor

R-F Skewed Hybrids. Type H1SB and H1SB-R. & R-F Balanced Hybrids Type H1R, H3X and Type H1RB, H3XB and Type H1RB-40. System Manual CH44 VER03

4CM500,000G MULTIPHASE-COOLED POWER TETRODE

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE /

Type 297, High-Voltage Mica Capacitors Corona-free Mica Coupling Capacitors for Medium-Voltage PDA s

Marconi Applied Technologies CCD39-01 Back Illuminated High Performance CCD Sensor

83092 Photomultiplier Family

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 6410A

CCD42-80 Back Illuminated High Performance CCD Sensor

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE /

NOsparc! MHXAC1F120! MHXAC1F240! MHXAC1F480 PATENTS AND PATENTS PENDING. Contact Arc Suppressor

Rotating Anode X-ray Tube Assembly

4X150A/7034 Radial Beam Power Tetrode

Transmitter Tetrode. Approx. weight 1,1 kg Packing dimensions: approx. 310 mm 310 mm 320 mm. Siemens Aktiengesellschaft 375

Proximity Sensor Terminology

Schottky Rectifier, 440 A

E2V Technologies CCD42-10 Inverted Mode Sensor High Performance AIMO CCD Sensor

codestrip, these modules detect relative linear position.

Product Information PI

Log Periodic Dipole Array Antenna

Dynamo Brushless DC Motor and GreenDriveTM Manual

Rotating Anode X-Ray Tube Housing Assembly. General Data

A Prototype Frequency Machine for Plasma Tube Research

MAIN FEATURES OVERVIEW GENERAL DATA ORDERING INFORMATION

Transcription:

The data should be read in conjunction with the Magnetron Preamble and with British Standard BS9030: 1971 Abridged Data Mechanically tuned pulse magnetron intended primarily for linear accelerators. Frequency range (cooling water 40 ) - 2993 to 3002 MHz Peak output power - 3.1 MW Magnet - separate Output - to No. 10 (WR 284 waveguide) (72.14 x 34.04 mm internal) Cooling - Water The use of an isolator is recommended (see note 1) MG7095 Tunable S-Band Magnetron for Switched Energy Applications General Data Electrical Cathode - Indirectly heated Heater voltage (see note 2) - -17 V dc Heater current - 10.6 A Peak heater starting current, not to be exceeded Cathode pre-heating time (minimum) Mechanical - 20 A max - 4.0 min Overall dimension - see outline Net weight - 8 kg approx. Accessories Electromagnet (see notes 5 and 6) - MG6062 Waveguide transition - M4152S Magnet - 8PM0100-SERIES Tuner revolutions to cover frequency range (see note 3). Mounting position (see note 4) - 4.75 - any Cooling The magnetron is water cooled and has an integral water jacket. The recommended water flow is 5 litres per minute or more; a pressure of approximately 1.25 kg/cm 2 will be necessary to give this rate of flow. The outlet water temperature must not exceed 50 C. Whilst e2v technologies has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any use thereof and also reserves the right to change the specification of goods without notice. e2v technologies accepts no liability beyond the set out in its standard conditions of sale in respect of infringement of third party patents arising from the use of tubes or other devices in accordance with information contained herein. e2v technologies (uk) limited, Waterhouse Lane, Chelmsford, Essex CM1 2QU United Kingdom Holding Company: e2v technologies plc Telephone: +44 (0)1245 493493 Facsimile: +44 (0)1245 492492 Contact e2v by e-mail: enquiries@e2v.com or visit www.e2v.com for global sales and operations centres. e2v technologies (uk) limited 2016 A1A-774962 Version 6, October 2016 Template: DF764388A-11 123748

Maximum and Minimum Ratings (Absolute values) These ratings cannot necessarily be used simultaneously, and no individual rating should be exceeded. Table 1 Magnetic field (see notes 5, 6 and 7). Min Max 100 165 mt Heater voltage (see note 2). -16.5-17.5 V dc Heater starting current (peak). - 20 A Anode voltage (peak). - 52 kv Anode current (peak) (see note 8). 60 120 A Input power (mean). - 8.0 kw Pulse duration. - 5.0 µs Rate of rise of voltage pulse (see note 9). 80 120 kv/µs Outlet water temperature. - 50 C VSWR at output couplet (see note 1) Pressurizing of waveguide (see note 10). - 1.5:1. - 300 kpa Test Conditions and Limits The magnetron is tested to comply with the following electrical specification. Test Conditions Magnetic field (see notes 5 and 7). 163.0 ± 2.5 1630 ± 25 Heater voltage (for test). 6.0 V Anode current (peak). 120 A Duty cycle (see note 11). 0.001 Pulse duration. 5.0 µs VSWR at output coupler. 1.1:1 Minimum rate of rise of voltage pulse (see note 9) mt gauss. 120 kv/µs Limits Min Max Anode voltage (peak). 46 52 kv Output power (peak) (see note 12). 3.1 - MW Frequency (see notes 13, 14 and 15) lower end of tuning range. - 2993 MHz upper end of tuning range. 3002 - MHz RF bandwidth at ¼ power. - 1.5 MHz Frequency pulling (VSWR not less than 1.5:1). - 7.0 MHz Stability (see note 16). - 0.5 % Heater current. See note 17 Inlet water at 40 C. Life Test The quality of all production is monitored by the random selection of tubes which are then life-tested under typical operation conditions. If the tube is to be operated under conditions other than those specified herein, e2v should be consulted to verify that the life of the magnetron will not be impaired. Notes 1. It is recommended that the magnetron should be isolated from the load by means of an isolator of approved design. Information on the characteristics of a suitable isolator may be obtained from e2v. 2. With no anode input power. It is recommended that a DC power supply is used to operate the heater. Use of an AC supply may result in damage to the heater circuit. The use of an AC heater supply during HT operation may result in frequency modulation of the RF pulses. Contact e2v for further information. The heater voltage must be reduced within 5 seconds after the application of HT according to the schedule shown on page 4. The magnetron heater must be protected against arcing by the use of a minimum capacitance of 4000 pf shunted across the heater directly at the input terminals; in some cases a capacitance as high as 2 µf may be necessary depending on the equipment design. e2v technologies (uk) limited 2016 Document subject to disclaimer on page 1 A1A-774962 Version 6, page 2

3. The tuner mechanism is driven by means of three tapped holes in the tuner knob (see outline drawing) via a flexible drive. The torque required is 0.7 kg-cm minimum; the torque applied must not exceed 5.0 kgcm. 4. To minimize frequency deviation when the magnetron is rotated about a horizontal axis, this axis should be parallel to the axis of the tuner. 5. The magnetron is designed for use with a separate permanent magnet or electromagnet. The north seeking pole of the magnet must be adjacent to the cathode terminal, marked C. The position of the magnet must be adjusted so that the axis of the field is in line with the axis of the anode and is at right angles to the H plane of the system waveguide. The user is invited to consult e2v on the choice of magnets. 6. The magnetron can be used at lower power levels by reducing both the magnetic field (which controls the peak voltage) and the peak current (see graph); this is necessary for maintaining a good RF spectrum and constant impedance. will be 0.5 MHz high 20 seconds after switching on HT and 0.1 MHz high 5 minutes after switching on. 14. With a water flow rate of 5.0 litres per minute. 15. The maximum variation of frequency when the magnetron is rotated through 360 around any axis of the magnetron will not be greater than 0.7 MHz. 16. With the magnetron operating into a VSWR of 1.15:1. Pulses are defined as missing when the RF energy level is less than 70% of the normal energy level in a 0.5% frequency range. Missing pulses are expressed as a percentage of the number of input pulses applied during the period of observation after a period of 10 minutes operation. 17. Measured with heater voltage of -17 V and no anode input power, the heater current limits are 9.5 A minimum, 11.5 A maximum. 7. Shape and limits of magnetic field. Seek advice from e2v. 8. Stable magnetron performance not guaranteed below 60A, but can be operated down to 40A without risk of damage 9. Defined as the steepest tangent to the leading edge of the voltage pulse about 80% amplitude. Any capacitance in the viewing system must not exceed 6.0 pf. 10. At the maximum pressure of 300 kpa gauge the maximum leakage will be such that with an enclosed volume of 1 litre the pressure will not drop by more than 70kPa in 7 days. It is recommended that the pressurised arc suppressant gas used in the waveguide should contain no more helium than is typically found in air, i.e. 0.0005% 11. The various parameters are related by the formula: Pi = I apk x v apk x Du Where Pi = mean input power in watts I apk = peak anode current in amperes v apk = peak anode voltage in volts and Du = duty cycle. 12. The maximum variation of mean output power when the magnetron is rotated through 360 around any axis of the magnetron will not be greater than 4%. 13. The frequency of the magnetron will vary after the application of anode voltage. Typically the frequency e2v technologies (uk) limited 2016 Document subject to disclaimer on page 1 A1A-774962 Version 6, page 3

Health and Safety Hazards e2v magnetrons are safe to handle and operate provided that the relevant precautions stated herein are observed. e2v does not accept responsibility for damage or injury resulting from the use of electronic devices it produces. Equipment manufacturers and users must ensure that adequate precautions are taken. Appropriate warning labels and notices must be provided on equipment incorporating e2v devices and in operating manuals. High Voltage Equipment must be designed so that personnel cannot come into contact with high voltage circuits. All high voltage circuits and terminals must be enclosed and failsafe interlock switches must be fitted to disconnect the primary power supply and discharge all high voltage capacitors and other stored charges before allowing access. Interlock switches must not be bypassed to allow operation with access door open. RF Radiation Personnel must not be exposed to excessive RF radiation. All RF connectors must be correctly fitted before operation so that no leakage of RF energy can occur and the RF output must be coupled efficiently to the load. It is particularly dangerous to look into open waveguide or coaxial feeders while the device is energized. Screening of the cathode sidearm of high power magnetrons may be necessary. X-Ray Radiation High voltage magnetrons emit a significant intensity of X- rays not only from the cathode sidearm but also from the output waveguide. These rays can constitute a health hazard unless adequate shielding of X-ray radiation is provided. This is a characteristic of all magnetrons and the X-rays emitted correspond to a voltage much higher than that of the anode. e2v technologies (uk) limited 2016 Document subject to disclaimer on page 1 A1A-774962 Version 6, page 4

Heater Voltage Reduction Schedule Recommended Parameters for Various Power Levels e2v technologies (uk) limited 2016 Document subject to disclaimer on page 1 A1A-774962 Version 6, page 5

Hole Ø8.00 ±0.05 Ø152.25 Ø139.70 2 Holes threaded ¼ - 28 UNF-2B by 6.00 min deep Outline (All dimensions without limits are nominal) 22.5 Ø38.00 Ø51.00 22.5 Outline Notes. 1. This surface is marked with the letter C to indicate the cathode terminal. 2. The magnetron will fit between magnet poles 76.46 diameter and 75.44 apart. 3. Positional tolerance of holes 0.15 diameter. 4. Positional tolerance of holes 0.05 mm 5. Positional tolerance of flange 1.5 mm diameter with respect to reference planes A and B 8 Holes Ø8.00±0.10 Equispaced See Note 3 Reference Plane A Ø19.00 107.00±0.30 107.00 Hole Ø6.40 ±0.05 Reference Plane B 73.82±0.20 See Note 2 See Note 1 6.35±0.10 55.96±0.16 25.00 3 holes theaded 10-32 UNF-2B by 6.50 deep. Equispaced See Note 4 370.00 Ø19.05 X 191.50 12.50±0.50 Water Jacket Connections Threaded ¼ BSP 89.00 135.50 31.40 Ø94.85 5.55 Ø91.82 Ø133.50 See Note 5 8 holes Ø6.40±0.10 Equispaced See Note 3 35.00 Ø104.90 3.20 Hole threaded M8 x 15.00 DP Ø120.65 ±0.13 Scrap View in Direction X e2v technologies (uk) limited 2016 Document subject to disclaimer on page 1 A1A-774962 Version 6, page 6