Installation Instructions (For Dealer or Contractor)

Similar documents
Wall Mount Bracket YM-81

Installation Instructions

ELPMB27. Short Throw Projector Wall Mount Installation Manual xxx(fr) xxx(de) xxx(it) xxx(es) xxx(pt) xxx(zhs)

Aluminum Frame Type Instruction Manual

PWM-T210 Installation Instructions UNIVERSAL FLAT PANEL MOUNT

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

INSTALLATION GUIDE MICROWAVE OVEN UPMC3084ST. MFL _00

Universal flat-panel mount

INSTALLATION MANUAL PBL-UMP

ET-PKL100S. Installation Instructions. Ceiling Mount Bracket (for Low Ceilings) Model No.


SUPPLEMENTARY INSTALLATION INSTRUCTIONS Ventilating Fan (Contractor Pack)

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

Wooden Frame Type Instruction Manual

Crosby & Bown. Motorised Projection Screen. User Guide. Thank you for purchasing a Crosby and Bown projection screen

ATBG280/6 Bench Grinder Bench Grinder ATBG280/6 230V-50Hz 280 Watt 150mm x 25mm Wheel size

Wall mounting bracket

Installation Instructions

INSTALLATION MANUAL PBC-UMS

LCD DISPLAY MOUNT

Sliding Door Kit

INSTALLATION MANUAL ELPMB50

INSTALLATION MANUAL SP-CEIL-012

Installation Instructions

Installation Instructions

Installation Instructions

Tube Facing Tool.

PMT-L31 (for Low Ceilings) PMT-H35 (for High Ceilings)

Blackout Fan Kits with Breathable Wall Light Traps

ORP-F1 Regular: Basic / J-Connection / M-Connection

Model POA-CHB-XL50. Assembly and Installation Manual. Projector Bracket. Contents. Be sure to consult with a qualified installation specialist

Installation Instructions

NOVA-EXT Versatile Projector Mount Model: NOVA-EXT

VYTEX PREMIUM SLIDING GLASS DOOR. Table of Contents. Precautions and Safety 2. Tools Required...3. Inspect and Prepare Door...4

FD50-H SLIDING DOOR SYSTEM Installation Manual (Ceiling Mount Type for Pocket Door, with Dual Soft Close) Part No.FD50DHCP-PD

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

Operating Manual 6 Industrial Bench Grinder ATBG280/

Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims

Blackout Fan Kit with Breathable Wall Light Trap

Quick Set Dovetail Jig

Installation Instructions

OWNER S MANUAL #DC2V3 #DC2V3CF 1-1/2 HP, 1500 CFM DUST COLLECTOR. VERSION 1 -w/ 6 INLET PORT. Model #DC2V Global Rd.

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

ROTARY HAMMER OWNER'S MANUAL

Sliding Door Kit

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

Installation Manual. (for qualified service personnel) Table of Contents. For Your Safety... 39

Wall mounting bracket

Blackout Fan Kits with Breathable Wall Light Traps

INSTALLATION INSTRUCTIONS

Installation Guide Guide d installation

Installation Instructions

incorrect use or handling that exceeds normal operating limits.

Dual Arm Tilt LCD Mount

Handling instructions

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System

Frameless Inline Door With Return QCI5263

INSTALLATION MANUAL SFM2

ClearSpan PolyMax Windbreak Wall

COMPLEX GRINDER OF MILL& DRILL

INSTALLATION MANUAL ELPMBUNI

ORP-R1 Mini/Regular: Basic / J-Connection / M-Connection

ATD AMP Variable Speed Reciprocating Saw Owner s Manual

Maintenance and other important non-personal injury and non-material damage instructions or statements that should be observed.

Thanks for shopping with Improvements! 7 ft. Wall Christmas Tree w/ Stand Item #419359

HEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING

INSTRUCTION BOOKLET AND WARRANTY INFORMATION 6 BENCH GRINDER

Diva Acoustical Ceiling

General Installation Instructions

10" Wet Tile Cutting Saw

OPERATOR'S MANUAL ROUTER MOUNTING KIT

Installation Instructions

Installation and Assembly: Articulating Swivel Arm for 37" - 60" Flat Panel Displays

BEFORE YOU BEGIN Read these instructions completely and carefully.

Installation Instructions

18 GAUGE ELECTRIC METAL SHEAR

Model S-520 Coin Counter / Sorter Operating Manual

48 in. X 96 in. 500 Pound Capacity Motorized Overhead Storage Unit Installation Guide [OPTION B] MODEL # PRM4X8 Patent Pending

Football Goal Posts MODEL SERIES: FGP400 and FGP600 series

G. H. I. N. J. O. 22"x 28" Poster Holder. P. Q. romotional wall displ

METAL BENDER OPERATING & MAINTENANCE INSTRUCTIONS Model Nos: CCB1 & CCB2 Part Nos: & CCB2 CCB1

Wall Mount Assembly and Mounting Guide (55 /84 )

GENERAL OPERATIONAL PRECAUTIONS

SB-WM-ART1-M-BL. Weatherproof Universal Single-Arm Articulating Mount for Medium Displays INSTALLATION MANUAL

ClearSpan PolyMax Windbreak Wall

PAM-200 Universal Projector Mount

Tilting & Swiveling Plasma/LCD Flat Panel Wall Mount Installation Guide Model: A380SM

Nibbler MODEL JN1601. WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

Wall Mounting Bracket

ClearSpan Hydroponic Table Kit

The POWER. In PRESENTATION PRODUCTS. Instruction Book for TENSIONED DUAL MASKING ELECTROL DA-LITE SCREEN COMPANY, INC.

VARIABLE SPEED WOOD LATHE. Model DB900 INSTRUCTION MANUAL

Universal flat-panel mount

Drill INSTRUCTION MANUAL. WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE 1 REFERENCE.

SB-WM-ART2-L-BL SB-WM-ART2-XL-BL

ENGLISH (Original instructions) INSTRUCTION MANUAL. Shear Wrench 6922NB DOUBLE INSULATION. IMPORTANT: Read Before Using.

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

GrowSpan Single Swinging Door Black-Out Door Kit

PMT-L11 (for Low Ceilings) PMT-H15 (for High Ceilings)

Jabiru Installation instructions

Transcription:

9701R870HH9001 HOME USE LOSSNAY TYPE Installation Instructions (For Dealer or Contractor) Before proceeding with the installation work, be sure to read through these instructions. The installation work should be done by an authorized dealer or qualified contractor. Please ensure that the separate Operating Instructions are handed over to the customer. Essential safety precautions Before proceeding with operation, please be sure to read Essential Safety Precautions as it will tell you how to operate the product properly and safely. The displays have the following significance. WARNING CAUTION This applies to mishandling or misoperation of the product which may lead to a fatal or serious injury. This applies to mishandling or misoperation of the product which will lead to an injury or damage to your home, household effects, etc. The graphic symbols have the following significance. Prohibited Do NOT disassemble. Use is prohibited wherever water is present. You must follow the instructions given. Disconnect the power plug. Contents Page Before installation Safety precautions 2 Outline drawings 2 Installation positions 3 Installing the unit Unpacking 4 Wall hole construction 5 Preparations before installation 5 If the wall is more than 300 mm thick 6 Installing the mounting plate 6 Installing the main unit 6 Outdoor construction 7 Test run Test run 8 1

Before installation Safety precautions WARNING Do not alter the unit or disassemble it more than necessary. (Fire, electric shock or injury may result.) Do not install the unit in a bathroom or other highly humid location. (Fire or electric shock may result.) Use the unit at the rated voltage and within the control capacity range. (Failure to do so may result in fire or electric shock.) Make sure the outside air intake opening is positioned so that it will not take in combustion gases or other exhaust. Position the unit so that it will not become covered with snow. (If intake air is not fresh, oxygen may become depleted in the room.) Install the unit securely to a sufficiently strong wall surface. (Injuries may result if the unit falls.) CAUTION Install the unit only on a wall. Do not install it on a ceiling. (Injuries could result if the unit falls.) Do not install the unit in excessively hot areas, areas of oily smoke, or near open flames (Fire may result). Wear gloves when attaching the unit (or injury may result). Attach the unit so that the air supply/exhaust pipes slope downward toward outdoors. (Rainwater entering the unit could cause electric shock or fire, or wet indoor items.) Install the supplied outdoor weather covers. (Rainwater entering the unit could cause electric shock or fire, or wet indoor items.) After installation, be sure to remove the power plug from the wall outlet when not using the unit for an extended period. (Failure to do so could cause insulation deterioration, resulting in electric shock or fire from a short-circuit.) Outline drawings Fresh air supply grille Indoor air exhaust grille Outer diameter 752 Outdoor weather cover Power cord Cord Shutter knob Shutter open position Operation indicator Shutter closed position Wall thickness 50 to 300 (Unit: mm) If the wall is thicker than 300 mm, use the extension pipes and the pipe extension joints (separately sold parts). 2

Installation positions Mounting plate Edge of main unit Require to be secured Mounting hole 36 6 Require to be secured (Adjustable) min. min. (Adjustable) min. (Min.) (Max.) min. (Adjustable) Pitch Position of screw for securing unit horizontally (Unit: mm) Position of screw for securing unit horizontally Air exhaust hole (80 to 90 wall hole) Air intake hole (80 to 90 wall hole) 2 WHITE WHITE AC 220-240V 50Hz 220V 60Hz BROWN L BLUE N BROWN BROWN 0.4 1 3 BLUE BLUE BLUE NEON LAMP RED RED R E D BLACK BLACK PINK BLACK GREEN/YELLOW 3

Installing the unit Unpacking Pipe mounting plates: 2 Weather covers: 2 s: 2 Flange nuts: 2 Aluminum tape: 2 packets Weather cover mounting plate: 2 Screws for securing weather covers: 4 Mounting plate Wood screws: 10 Main unit Screws for securing main unit: 2 (For attaching mounting plate/for securing main unit horizontally) Remove mounting plate. Remove two screws for se-curing main unit. Keep the screws for securing the main unit in a safe place. Screws are needed when installing the main unit. 4

Wall hole construction 83 mm min. 44 mm min. 83 mm min. Wood screw (for loose attachment) Determine the installation position. 1. Place the mounting plate on the wall. 2. Check that the reinforcement (indoor wall) is positioned properly to secure the mounting plate. 3. Attach the mounting plate loosely (with single wood screw). Reinforcement 113 mm min. (from nearest obstruction) Mounting plate hole pitch Calibrations Exhaust pipe hole center Air supply pipe hole center Determine the position of the wall holes. 1. Place a caliper on the calibrations on the mounting plate. 2. Mark the center position of the wall hole. Position the wall holes away from obstructions in the wall, within the ranges shown in the table below. Vertical direction Horizontal direction Exhaust pipe Air supply pipe Air supply/exhaust hole position hole position pipe hole pitch From main unit center 15 mm below to 25 mm above From main unit From main unit center to left center to right 200 to 350 mm 85 to 175 mm 85 to 175 mm Wall 5 Wall hole Drill the wall holes. 1. Remove the mounting plate. 2. Drill wall holes of 80 to 90 mm. To prevent rainwater entering indoors, drill the holes so they slope downward toward outdoors. Indoors Outdoors Lossnay element Preparations before installation Indoors Wall thickness 30mm Outdoors Cut here. Cutting air supply/exhaust pipes. 1. Measure the wall thickness. 2. Cut the pipes to a length of [wall thickness] + 30 mm. Be sure to cut off the end without the flange. Before installation Under After installation Under Catch Secure air supply/exhaust pipes to mounting plate. 1. Insert pipe into mounting plate. 2. Rotate pipe counterclockwise. 3. Secure flange (four catches). Catch Pipe mounting plate 5

If the wall is more than 300 mm thick Use the extension pipes (separately sold Parts P-100P-E) and pipe extension joints (separately sold Parts P-100PJ-E). Attach them to the pipes as shown below. (Each set can extend the pipes by 300 mm.) O-ring Quantity Requirement 2 sets of P-100P-E for 1 VL-100U-E 1 set of P-100PJ-E for 1 VL-100U-E 1. Screw the extension joints all the way into the air supply/exhaust pipes, making sure they fit securely. Caulking Before screwing the extension joints into the pipes, apply caulking (commercially available) to the O-rings on the joints (to prevent condensation inside the pipes wetting the indoor wall). Extension joint (P-100PJ-E) Extension pipe (P-100P-E) 2. Screw the extension pipes all the way into the extension joints, making sure they fit securely. 3. Cut the pipes to a length of [wall thickness] + 30 mm. Installing the mounting plate Wood screw Be sure to secure. Screw (for loose attachment) Weight Mounting plate Secure mounting plate. Secure the mounting plate to the wall (using seven wood screws and the single screw for loose attachment). You can align the plate horizontally by suspending a weight from the top and aligning its string with the center line. Be sure to secure the mounting plate with the two screws near the catches, and with screws in symmetrical positions. To attach the plate to a concrete wall, use concrete screws to secure it (commercially available). Secure air supply/exhaust pipes. Pipe mounting Wall hole plate Under Aluminum tape Under CAUTION Install the air supply/exhaust pipes so that they slope downward toward outdoors. (Rainwater entering the unit may cause electric shock or fire, or wet indoor items.) Under mark 1. Pass the air supply/exhaust pipes through the wall holes. (The under mark should be on the bottom.) 2. Secure the pipes with aluminum tape. Installing the main unit Main unit Square hole Catch Secure main unit. 1. Hang main unit on mounting plate. 2. Secure main unit with the two screws provided. (Press main unit into wall.) Screw for securing main unit Mounting plate 6

Outdoor construction Attach weather covers packed together with unit. Caulking Wall hole caulking Fill in any gaps between the air supply/ exhaust pipes and the wall holes with caulking (commercially available). Weather cover mounting plate UPPER Attaching weather covers 1. Insert weather cover mounting plate into air supply/exhaust pipes. 2. Tighten flange nuts. (Secure so that upper marks on flanges are on top.) Weather cover mounting plate have two holes ( 5mm) in them. Use these holes to secure the flanges to the wall. 3. Secure the weather covers with the screws. Flange nut Weather cover Cap area Screw for securing weather cover To keep the air supply and exhaust sides separate, each weather cover attaches only to one side. Check that each cap area is positioned on the left, as shown in the diagram. Caulking Weather cover To prevent rainwater leakage Caulk any gaps around the weather covers. After installing the unit, before conducting a test run, check the unit again to make sure it has been installed correctly. Be sure to correct any problems discovered. (Failure to correct problems may result in poor performance as well as causing safety problems.) 7

Test run Insert the power plug into the wall outlet. Knob Open Check the shutter s open/close operation. Slide the knob to check the shutter opens and closes normally. Open Closed Closed Check operating modes. 1. Slide the knob to the shutter open position. 2. Pull the cord to start operation. 3. Pull the cord a few more times to check the unit responds accordingly. Cord Operation indicator Once Twice Three times HI operation LO operation (Operation indicator lights.) Off (Operation indicator goes out.) Check there are no strange vibrations or noises. Stop the unit after checking. Knob Close the shutter. Slide the knob to the shutter closed position. Close Close Remove the power plug from the wall outlet. 8