ELPA-SINE SINGLE PHASE AC ELECTRONIC LOAD

Similar documents
Additionally, voltage & current signals can be routed to an oscilloscope through analog

LAB-GSS. BIDIRECTIONAL DC SYSTEMS UP TO 128kW

LAB-AUTO AUTORANGING DC POWER SUPPLY

simulations that extend the test capability for the most demanding engineering and automated test applications.

MODEL SERIES MODEL SERIES. Programmable DC Electronic Load

MODEL SERIES MODEL SERIES. Programmable DC Electronic Load

IT7600 High Power Programmable AC power supply

Oscilloscope Function

IT7600 High performance programmable AC power supply. mu High power APPLICATIONS. Military& Aerospace. Scientific research& Institutions

5V SERIES DC LOADS 5V SERIES DC LOADS. Key features:

PLZ-4W Series. Multifunctional Electronic Load. Electronic Load

Programmable AC Power Source Model 9801

AC Power Sources. Newtons4th Ltd

GE-AC&DC AC&DC Voltage Source

Models 31120/31120A/31180/31180A Programmable AC Power Source

Model 61511/61512/61611/61612

Parallel AMX AC Power Systems

3B SERIES AC & DC LOADS

PROGRAMMABLE DC ELECTRONIC LOAD MODEL SERIES MODEL SERIES KEY FEATURES. Rated power: 250W, 350W. Voltage range: 150V, 600V

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES

Programmable DC Electronic Load

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.

Built To Order 3 Phase UPS Systems

The Front Panel at a Glance

AC+DC Power Sources. Newtons4th Ltd. N4A06-6kVA Single Phase N4A18-18kVA Three Phase N4A30-30kVA Three Phase Higher Power Systems also Available

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

System Electronic Loads PLZ-3W/3WH Series

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

EAC/AFV-P SERIES. High performance programmable AC power source 600 VA to 5 kva only in 2 U or 5 U

PROGRAMMABLE AC POWER SOURCE MODEL 61511/61512/61611/61612

LAB-MOBI MULTIPLE OUTPUT BIDIRECTIONAL PSU

been built in for recall of the stored settings at any time. For automated testing, the save and recall functions can save a great deal of time.

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES

AFV-P 2U/4U. AC + DC Power Solutions. series. Transient Generation for Disturbance Tests. only. High Performance Programmable AC Power Source

Laboratory 2. Lab 2. Instrument Familiarization and Basic Electrical Relations. Required Components: 2 1k resistors 2 1M resistors 1 2k resistor

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

PROGRAMMABLE AC POWER SOURCE

Bench LCR Meter Model 891

EL-AC Electronic Load

Technical data Sheet HLD30-60 series

TECHNICAL DATA SHEET B9600FXS kva

GENERAL PURPOSE POWER SUPPLIES, SPECIAL PURPOSE POWER SUPPLIES, AND ELECTRONIC LOADS SELECTOR GUIDE

Technical Data Sheets

Modular Programmable DC Electronic Load MDL Series

TEST & MEASURING INSTRUMENT CATALOG

PA-AB 4Q POWER AMPLIFIER VA Page 1/5

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

Power Electronics Testing

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

APS-1102 Programmable AC/DC Power Source New Product Announcement

500 W up to 28,800 W 60 V up to 800 V 45 ma up to 2,700 A. Electronic Load ZS

High Power Programmable DC Power Supplies PVS Series

GAMMA 20 DIGITAL MULTIMETER

PM6000. Voltech. Power Analyzer

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

AIM & THURLBY THANDAR INSTRUMENTS

Manatronics 110V / 100 Amp Load

Specifications. 744 Users Manual

SP300VAC1500W Programmable AC Source

Power IT LV Active Filters PQFA - PQFL - PQFT

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the

1.2kV. The provides a low range error up to 0.05% and is capable of meeting the measurement uncertainty requirement of IEC 62301/EN50564.

Manatronics 48V / 300 Amp Load

TOSHIBA International Corp

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES PRELIMINARY. Regenerative Grid Simulator. Key Features :

Designated client product

Looking For A High Power, Low Profile Power Supply? KEPCO. Has More Than One Way To Help Make Your Decision Easier! AN ISO 9001 COMPANY

SDM3045X Digital Multimeter. DataSheet

AC POWER SOURCE CATALOG

2015 NEW PRODUCTS CATALOG

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES. Regenerative Grid Simulator. Key Features

Ground Bond & Optional HV & HC Scanner. Ground Bond & Functional Run Test. Ground Bond, Functional Run Test & Line Leakage Test. Features and Benefits

Analog Digital Multimeter with Insulation Resistance Measurement

Introduction: TAS PowerTek Ltd. MAVROS

PRODUCTS FOR ELECTRICAL SUB-STATIONS UPS, DC-AC INVERTERS, BATTERY CHARGERS, DC-DC CONVERTERS, 1-PHASE TO 3-PHASE CONVERTERS

Quanti Presentation. Finero 2010 For Finero s Distributors Internal Use Only.

SP300VAC600W Programmable AC Source

SDM3045X Digital Multimeter. DataSheet

AMX Series. Precision AC Test Power Single and Three Phase Linear AC Power Sources. Parallelable to 30 kva. T h e P o w e r o f E x p e r t i s e

P R O T R O N I X D i g i t a l P o w e r M e t e r M o d e l : A I n s t r u c t i o n M a n u a l

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

CHROMA ATE INC. Programmable AC Source 61500/61600 Series. Product Manager: Galen Chou

been built in for recall of the stored settings at any time. For automated testing, the save and recall functions can save a great deal of time.

Laboratory for Fundamentals of Electrical Engineering (Labor Grundlagen der Elektrotechnik) Equipment Manuals for use in laboratory for measurement

GAMMA 12 DIGITAL MULTIMETER

Issue 03/2013. The Electronic Load

True RMS Bench Multimeters 2831E and 5491B

Technical Data Sheet. Gamma 12. Gamma 12

Modular Controller. Key Features. Model Complete system controller for 8 channel applications; EDFA pumping or DWDM signal sources

RS Pro DIGITAL MULTI-METER SDM3055 SERIES

APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS

DM-5 Power Quality Analyzer

G-NET. 1 kva-10 kva. Rack & Tower UPS

SUBJECT TO CHANGE WITHOUT NOTICE

MEASUREMENTS & INSTRUMENTATION ANALOG AND DIGITAL METERS

Configurations The RS90 delivers up to 90 kva of AC or AC + DC power. In DC mode, 50% of the AC power level is available.

California Instruments Ls Series VA V A kva Programmable AC Power Source / Analyzer

Transcription:

ELPA-SNE SNGLE PHASE AC ELECTRONC LOAD POSTE PROBLEM SOLNG While primarily aimed at AC applications this series of electronic loads can also be used for DC testing. A comprehensive feature set is provided as standard. When in constant current operation the user can select between sine, square and DC waveforms. Peak currents can be simulated with the crest factor mode. A power factor can be set with adjustments from unity to 0 lagging or leading. The desired wave can be recalled from the front panel or selected via an optional computer interface. A turbo mode is included as standard. This provides the ability to test currents up to double the maximum current range for up to 1 second, ideal for inrush current testing. Sine, Step & Squarewave Loading Functions Adjustable Leading & Lagging Power Factor High Power Configurations to 180kW CC, C, CP, CR & Crest Factor Last Setting Memory Function DC to 440Hz Operation CONTENTS Standard ls & nterface Options 2 Master-Slave & Cabinet Options 3 General Specifications 4 Operating s 5-7 Test s 8-10 Measurements & Protection 10-11 WWW.ETPS.CO.UK

ELPA-SNE DATASHEET - PAGE 2 OF 12 STANDARD MODELS SELECTON TABLE Part Number Max Power Maximum Range Dimensions Outside of Cabinet (W H D) Cabinet Dimensions (W H D) ELPA-SNE 1875 1875W rms / 500dc 0-18.75Arms 19 4U 513mm N/A ELPA-SNE 2800-LC 2800W rms / 500dc 0-18.75Arms 19" x 4U x 513mm N/A ELPA-SNE 2800 2800W rms / 500dc 0-28Arms 19 4U 513mm N/A ELPA-SNE 3750-LC 3750W rms / 500dc 0-28Arms 19" x 4U x 513mm N/A ELPA-SNE 3750 3750W rms / 500dc 0-37.5Arms 19 4U 513mm N/A ELPA-SNE 5600 5600W rms / 500dc 0-56Arms 19 8U 513mm 480mm 458mm 590mm* ELPA-SNE 7500 7500W rms / 500dc 0-75Arms 19 8U 513mm 480mm 458mm 590mm* ELPA-SNE 11250 11250W rms / 500dc 0-112.5Arms 19 12U 513mm 480mm 636mm 590mm* ELPA-SNE 15000 15000W rms / 500dc 0-112.5Arms 19 16U 513mm 480mm 814mm 590mm* ELPA-SNE 18750 18750W rms / 500dc 0-112.5Arms N/A 600mm 1283mm 600mm* ELPA-SNE 22500 22500W rms / 500dc 0-112.5Arms N/A 600mm 1283mm 600mm* * This model comes pre-fitted into its own wheeled cabinet. OPERATNG RANGES 1875 2800-LC 2800 3750-LC 3750 100 149 100 133 100 10 5.35A 6.25A 12.5A 18.5A 18.75A 8A 12.5A 18.75A 10 8A 9.375A 18.75A 27.75A 28A 10.7A 18.6A 28A 10 10.7A 12.5A 25A 37A 37.5A 5600 7500 11250 15000 18750 133.3 166.6 100 100 100 10 16A 18.75A 37.5A 55A 56A 10 21.4A 25A 50A 74A 75A 10 32.1A 37.5A 75A 111A 112.5A 42.8A 75A 111A 112.5A 53.5A 75A 111A 112.5A 22500 200 64.2A 75A 111A 112.5A NTERFACE OPTONS OPTONS CODE DESCRPTON /GPB /RS232 /USB /LAN GPB interface RS232 interface USB interface LAN interface

MASTER-SLAE CAPABLTY ELPA-SNE DATASHEET - PAGE 3 OF 12 Up to 8 ELPA-SNE systems can be arranged in single phase parallel connection. Each electronic load is able to operate independently, so that systems can be reconfigured, expanded or broken up as needs dictate. The current is actively shared between each load. The ammeter of the master unit shows the total current that is the sum of all ammeters, The voltmeters of the slaves will show SL1 and SL2. The modular approach is useful for test houses and research labs who regularly test different sized power devices. ndividual units can be used for the day to day testing of multiple small devices, then grouped together for larger projects. ELPA-SNE 22500 rms / 500dc 0-112.5Arms 0-225Arms 0-337.5Arms 0-450Arms 0-562.5Arms 0-675Arms 0-787.5Arms 0-900Arms 22,500W 1 unit 45,000W 2 units 67,500W 3 units 90,000W 4 units 112,500W 5 units PARALLEL CONNECTON 135,000W 6 units 157,500W 7 units 180,000W 8 units CABNET OPTONS Units can be treated to a laboratory rack or flight case integration. Having a power system mounted into a flight case on castors is often advantageous, especially when several departments or test cells share the same equipment. Multiple power systems can be fitted into the same flight case. Door hangers are fitted to flight cases for convenience. Existing ETPS systems can also be retrospectively integrated into new flight cases where requested. THREE PHASE MODE ELPA-SNE units with identical nominals can be configured in Δ or Y connections for 3 phase applications. Systems can be expanded up to 180kW per phase using the master/slave interface. The setting current value (single phase current value) will be sent to each slave unit automatically, the user does not have to set each unit. Three Phase Source Δ CONNECTON a (line 1) i ab b (line 2) i bc c (line 3) + 3750W Load A - + 3750W Load B - i ca - 3750W Load C + Three Phase Source Y CONNECTON a (line 1) b (line 2) c (line 3) i a + 3750W Load A - i b + i c 3750W Load B - + 3750W Load C - WWW.ETPS.CO.UK

GENERAL SPECFCATONS STANDARD FEATURES ELPA-SNE DATASHEET - PAGE 4 OF 12 Maximum Power 1875W 2800W 2800W 3750W 3750W Range 18.75Arms / 56.25Apeak 18.75Arms / 56.25Apeak 28Arms / 84Apeak 28Arms / 84Apeak 37.5Arms / 112.5Apeak Range 50-rms / 500dc Frequency Range Master/Slave Functionality DC, 40-440Hz (CC, CP ), DC-440Hz (LN, CR, C ) Yes, up to eight identical single phase units can be connected in parallel External Programming nput F.S. / 10dc, Resolution 0.1 External SYNC nput TTL monitor (solated) ±500 / ±10 monitor (solated) ±56.25Apk / ±10pk ±56.25Apk / ±10pk ±84Apk / ±10pk ±84Apk / ±10pk ±112.5Apk / ±10pk nterface (Option) Operating Temperature GPB, RS-232, LAN, USB 0 to 40 C (accuracy of the specifications provided are valid at 25 C ±5 C) of nput mpedence ~*0.3 ; ~*2.2 ~*0.3 ; ~*2.2 ~*0.45 ; ~*3.3 ~*0.4 ; ~*2.95 ~*0.6 ; ~*4.4 Weight 21.5kg 27.5kg 27.5kg 33.5kg 33.5kg Start Up Loading Load ON/OFF Angle Half Cycle & SCR/TRAC Loading Yes, power on loading during inverter / UPS start up 0-359 degree can be programmed for the angle of load ON and load OFF loading Positive or negative half cycle, 90 trailing edge or leading edge current waveform can be programmed Maximum Power 5600W 7500W 11250W 15000W 18750W 22500W Range 56 Arms / 168Apeak 75 Arms / 225Apeak 112.5 Arms / 337.5Apeak 112.5Arms / 337.5Apeak 112.5 Arms / 337.5Apeak 112.5 Arms / 337.5Apeak Range 50-rms / 500dc Frequency Range Master/Slave Functionality External Programming nput (Option) External SYNC nput DC, 40-440Hz (CC, CP ), DC-440Hz (LN, CR, C ) Yes, up to eight identical single phase units can be connected in parallel F.S. / 10dc, Resolution 0.1 TTL monitor (solated) ±500 / ±10 monitor (solated) ±168Apk / ±10pk ±225Apk / ±10pk ±337.5Apk / ±10pk ±337.5Apk / ±10pk ±337.5Apk / ±10pk ±337.5Apk / ±10pk nterface (Option) Operating Temperature GPB, RS-232, LAN, USB 0 to 40 C (accuracy of the specifications provided are valid at 25 C ±5 C) of nput mpedence ~*0.9 ; ~*6.6 ~*1.2 ; ~*8.8 ~*1.8 ; ~*13.2 ~*2.4 ; ~*17.6 ~*3.0 ; ~*22 ~*3.6 ; ~*26.4 Weight 58kg 70kg 105kg 140kg 260kg 295kg Start Up Loading Load ON/OFF Angle Yes, power on loading during inverter / UPS start up 0-359 degree can be programmed for the angle of load ON and load OFF loading Half Cycle & SCR/TRAC Loading OPERATNG MODES Positive or negative half cycle, 90 trailing edge or leading edge current waveform can be programmed RS C C R1 Constant Linear Constant Constant Resistance Constant Constant Power Rectifier Load

OPERATNG MODES ELPA-SNE DATASHEET - PAGE 5 OF 12 ELPA-SNE Series Operating s AC Load Functions DC Load Functions Sine Wave Source PWM, Step, Square Wave Source Constant Constant Linear Constant Linear Constant Linear Constant Constant Resistance Constant Resistance Constant Resistance Constant Power Constant Power Constant Constant Rectifier Load Non-linear Rectifier Load Non-linear + Constant Resistance Rectifier Load Non-linear Rectifier Load Non-linear + Constant Resistance CONSTANT CURRENT MODE FOR SNE-WAE Range 0-18.75A 0-18.75A 0-28A 0-28A 0-37.5A Resolution 0.3125mA/16bits 0.3125mA/16bits 0.5mA/16bits 0.5mA/16bits 0.625mA/16bits ±(0.1% of setting + 0.2% of range) at 50/60Hz Range 0-56A 0-75A 0-112.5A 0-112.5A 0-112.5A 0-112.5A Resolution 1mA/16bits 1.25mA/16bits 1.875mA/16bits 1.875mA/16bits 1.875mA/16bits 1.875mA/16bits ±(0.1% of setting + 0.2% of range) at 50/60Hz n constant current mode, crest factor and power factor tests can be performed on sine wave voltage sources. CC CC mode, Crest Factor = 2 CC mode, Crest Factor = 5 CC mode, Power Factor = +0.5 CC mode, Power Factor = -0.5 WWW.ETPS.CO.UK

OPERATNG MODES ELPA-SNE DATASHEET - PAGE 6 OF 12 LNEAR CC MODE FOR SNE-WAE, SQUARE-WAE OR QUAS-SQUARE WAE, PWM WAE Range 0-18.75A 0-18.75A 0-28A 0-28A 0-37.5A Resolution 0.3125mA/16bits 0.3125mA/16bits 0.5mA/16bits 0.5mA/16bits 0.625mA/16bits ±(0.1% of setting + 0.2% of range) at 50/60Hz Range 0-56A 0-75A 0-112.5A 0-112.5A 0-112.5A 0-112.5A Resolution 1mA/16bits 1.25mA/16bits 1.875mA/16bits 1.875mA/16bits 1.875mA/16bits 1.875mA/16bits ±(0.1% of setting + 0.2% of range) at 50/60Hz n linear constant current mode, both sine wave and non-sine wave voltage sources can be tested. The examples below show the testing of a PWM inverter driver step voltage source, as well as an offline UPS sine wave switch to square wave and a square wave switch to a sine wave waveform. Linear CC, PWM 10A 2.5Hz to 250Hz Linear CC, PWM 10A 2.5Hz Linear CC, PWM 10A 250Hz CC Linear CC, Step 10A Linear CC, UPS Sine to Square Waveform Linear CC, UPS Square to Sine Waveform RECTFED LOAD SMULATON FOR EC62040-3 AND EC61683 TEST SPECFCATONS The rectifier load mode is fully compliant with EC test specification requirements for the UPS, EC 62040-3 UPS Efficiency Measurement Non-Linear and EC 61683. The rectifier load mode uses CC + CR load mode and maintains current THD at 80%, to simulate the actual P nverter connected to the electronic device. R S C C R 1 Non-Linear CC mode for UPS test Rectifier Load The actual / A waveform 110, 5A + 22ohm Test 110, 10A + 11ohm Test P nverter test Non-Linear CC + Resistive mode (CC+CR)

OPERATNG MODES ELPA-SNE DATASHEET - PAGE 7 OF 12 CONSTANT RESSTANCE MODE Range 3.2Ω - 64kΩ 3.2Ω - 64kΩ 2.0Ω - 40kΩ 2.0Ω - 40kΩ 1.6Ω - 32kΩ Resolution 1 0.0052083mS / 16bits 0.0052083mS / 16bits 0.0078137mS / 16bits 0.0083333mS / 16bits 0.010416mS/16bits ±0.2% of (setting + range) at 50/60Hz CONSTANT OLTAGE MODE Range 50-rms / 500dc Resolution 0.1 ±(0.1% of setting + 0.1% of range) @ 50/60Hz CONSTANT POWER MODE Range 1875W 2800W 2800W 3750W 3750W Resolution 0.1W ±(0.1% of setting + 0.1% of range) @ 50/60Hz CREST FACTOR (CC & CP MODE ONLY) Range 2-5 Resolution 0.1 (0.5% / rms) + 1%F.S. POWER FACTOR (CC & CP MODE ONLY) Range 0 to 1 Lagging or Leading Resolution 0.01 1% F.S. CONSTANT RESSTANCE MODE Range 1Ω - 20kΩ 0.8Ω - 16kΩ 0.533Ω - 10.666kΩ 0.533Ω - 10.666kΩ 0.533Ω - 10.666kΩ 0.533Ω - 10.666kΩ Resolution 1 0.016666mS/16bits 0.020832mS/16bits 0.031248mS/16bits 0.031248mS/16bits 0.031248mS/16bits 0.031248mS/16bits ±0.2% of (setting + range) at 50/60Hz CONSTANT OLTAGE MODE Range 50-rms / 500dc Resolution 0.1 ±(0.2% of setting + range) @ 50/60Hz CONSTANT POWER MODE Range 5600W 7500W 11250W 15000W 18750W 22500W Resolution 0.1W 0.1W 1W 1W 1W 1W ±(0.2% of setting + range) @ 50/60Hz CREST FACTOR (CC & CP MODE ONLY) Range 2-5 Resolution 0.1 (0.5% / rms) + 1%F.S. POWER FACTOR (CC & CP MODE ONLY) Range 0 to 1 Lagging or Leading Resolution 0.01 1% F.S. 1 1 ms (millisiemens) is the unit of conductance (G). One siemens is equal to 1kΩ WWW.ETPS.CO.UK

TEST MODES BATTERY DSCHARGE FUNCTON (CC,LN,CR,CP) ELPA-SNE DATASHEET - PAGE 8 OF 12 ALL ELPA-SNE MODELS UP (TH) Battery Discharge Time 50 - rms / 500dc 1-99999 seconds (>27H) The ELPA-SNE has three inbuilt battery discharge tests The test results can be directly displayed on the LCD display for battery AH capacity, the voltage value after discharge and the cumulative discharge time. UP Constant Battery Battery UP Constant Power Battery Battery Constant Battery Battery CC Time CP Time Loading Discharge Time Time CC + UP Battery Discharge (Test 1) CP + UP Battery Discharge (Test 2) Programmed Battery Discharge Time (Test 3) UPS EFFCENCY MEASUREMENT Type Non-linear mode Operating Frequency Auto ; 40-440Hz Range 0-18.75A 0-18.75A 0-28A 0-28A 0-37.5A PF Range 0 to 1 Type Non-linear mode Operating Frequency Auto ; 40-440Hz Range 0-56A 0-75A 0-112.5A 0-112.5A 0-112.5A 0-112.5A PF Range 0 to 1 MEASURNG EFFCENCY FOR P SYSTEMS, POWER CONDTONERS FOR THD 80% Type Resistive + non-linear mode Operating Frequency Auto ; 40-440Hz Range 0-18.75A 0-18.75A 0-28A 0-28A 0-37.5A Resistive Range 3.2Ω - 64kΩ 3.2Ω - 64kΩ 2.0Ω - 40kΩ 2.0Ω - 40kΩ 1.6Ω - 32kΩ Type Resistive + non-linear mode Operating Frequency Auto ; 40-440Hz Range 0-56A 0-75A 0-112.5A 0-112.5A 0-112.5A 0-112.5A Resistive Range 1Ω - 20kΩ 0.8Ω - 16kΩ 0.533Ω - 10.666kΩ 0.533Ω - 10.666kΩ 0.533Ω - 10.666kΩ 0.533Ω - 10.666kΩ UPS BACK-UP FUNCTON (CC,LN,CR,CP) ALL ELPA-SNE MODELS UP (TH) UPS Back-Up Time 50 - rms / 500dc 1-99999 seconds (>27H)

TEST MODES AC TESTS ELPA-SNE DATASHEET - PAGE 9 OF 12 UPS EFFCENCY P NERTER EFFCENCY UPS TRANSFER TME UPS BACK-UP TME TURBO MODE (CURRENT / POWER 2) FUSE / BREAKER TRP / NON-TRP TME AC POWER SOURCE SHORT CRCUT / OPP / OCP FUSE / BREAKER TRP / NON-TRP TME AC POWER SOURCE SHORT CRCUT / OPP / OCP DC TESTS BATTERY DSCHARGE TME BATTERY DSCHARGE CAPACTY FUSE / BREAKER TRP / NON-TRP TME DC POWER SOURCE SHORT CRCUT / OPP / OCP TURBO MODE (CURRENT / POWER 2) FUSE / BREAKER TRP / NON-TRP TME AC POWER SOURCE SHORT CRCUT / OPP / OCP FUSE / BREAKER TRP / NON-TRP TME UPS TRANSFER TME Range 0-18.75A 0-18.75A 0-28A 0-28A 0-37.5A UP (TH) 2.5 Time Range 0.15mS-999.99ms Range 0-56A 0-75A 0-112.5A 0-112.5A 0-112.5A 0-112.5A UP (TH) 2.5 Time Range 0.15mS - 999.99ms TURBO MODE Maximum (for up to 1 second) 37.5Arms (ON) ( 2) 2, 18.75Arms (OFF) 37.5Arms (ON) ( 2) 2, 18.75Arms (OFF) 56Arms (ON) ( 2) 2, 28.0Arms (OFF) 56Arms (ON) ( 2) 2, 28Arms (OFF) 75Arms (ON) ( 2) 2, 37.5Arms (OFF) Maximum (for up to 1 second) 112Arms (ON) ( 2) 2, 56Arms (OFF) 150Arms (ON) ( 2) 2, 75Arms (OFF) 225Arms (ON) ( 2) 2, 225Arms (ON) ( 2) 2, 225Arms (ON) ( 2) 2, 225Arms (ON) ( 2) 2, FUSE TEST MODE ALL ELPA-SNE MODELS Trip / Non-Trip Time 0.1s - 1s (ON) / 0.1s - 9999.9s (OFF) Meas. ±0.003 seconds Repeat Time 0-255 SHORT/OPP/OCP TEST FUNCTON Short Time OPP/OCP Step Time 0.1s-1s / 0.1s-10s or cont. 100ms, up to 10 steps / 100ms OCP stop 37.5Arms (ON) 2, 18.75Arms (OFF) 37.5Arms (ON) 2, 18.75Arms (OFF) 56Arms (ON) 2, 28Arms (OFF) 56Arms (ON) 2, 28Arms (OFF) 75Arms (ON) 2, 37.5Arms (OFF) OPP Pstop 3750W (ON), 1875W (OFF) 5600W (ON), 2800W (OFF) 5600W (ON), 2800W (OFF) 7500W (ON), 3750W (OFF) 7500W (ON), 3750W (OFF) 2 Turbo mode for up to 2 the and Power rating support Fuse, Short/OCP/OPP test function WWW.ETPS.CO.UK

TEST MODES SHORT/OPP/OCP TEST FUNCTON ELPA-SNE DATASHEET - PAGE 10 OF 12 Short Time OPP/OCP Step Time 0.1s - 1s (ON) / 0.1s - 10s or continous (OFF) 100ms, up to 10 steps (ON) / 100ms (OFF) OCP stop 112Arms (ON), 56Arms (OFF) 150Arms (ON), 75Arms (OFF) 225Arms (ON), 225Arms (ON), 225Arms (ON), 225Arms (ON), OPP Pstop 11200W (ON), 5600W (OFF) 15000W (ON), 7500W (OFF) 22500W (ON), 11250W (OFF) 30000W (ON), 15000W (OFF) 37500W (ON), 18750W (OFF) 45000W (ON), 22500W (OFF) PROGRAMMABLE NRUSH CURRENT SMULATON: START - STOP / TSEP start, nrush Start 0-37.5A 0-37.5A 0-56A 0-56A 0-75A nrush Step Time 0.1ms - 100ms stop, nrush Stop 0-18.75A 0-18.75A 0-28A 0-28A 0-37.5A start, nrush Start 0-112A 0-150A 0-225A 0-225A 0-225A 0-225A nrush Step Time 0.1ms - 100ms stop, nrush Stop 0-56A 0-75A 0-112.5A 0-112.5A 0-112.5A 0-112.5A PROGRAMMABLE SURGE CURRENT SMULATON: S1/T1 - S2/T2 - S3/T3 S1 and S2 0-37.5A 0-37.5A 0-56A 0-56A 0-75A T1 and T2 Time 0.01s - 0.5s S3 0-18.75A 0-18.75A 0-28A 0-28A 0-37.5A T3 Time 0.01s - 9.99s or continuous S1 and S2 0-112A 0-150A 0-225A 0-225A 0-225A 0-225A T1 and T2 Time 0.01s - 0.5s S3 0-56A 0-75A 0-112.5A 0-112.5A 0-112.5A 0-112.5A T3 Time 0.01s - 9.99s or continuous MEASUREMENTS OLTAGE READBACK OLTMETER ALL ELPA-SNE MODELS Range 500 Resolution 0.01 ±0.05% of (reading + range) Parameter rms, Max/Min,+/-pk CURRENT READBACK AMMETER Range 9.375Arms / 18.75Arms 9.375Arms / 18.75Arms 14Arms / 28Arms 14Arms / 28Arms 18.75Arms / 37.5Arms Resolution 0.2mA / 0.4mA 0.2mA / 0.4mA 0.3mA / 0.6mA 0.3mA / 0.6mA 0.4mA / 0.8mA Parameter ±0.05% of (reading + range) at 50/60Hz, ±0.2% of (reading + range) rms,max, Min,+/-pk

MEASUREMENTS CURRENT READBACK AMMETER ELPA-SNE DATASHEET - PAGE 11 OF 12 Range 28Arms / 56Arms 37.5Arms / 75Arms 56.25Arms / 112.5Arms 56.25Arms / 112.5Arms 56.25Arms / 112.5Arms 56.25Arms / 112.5Arms Resolution 0.6mA / 1.2mA 0.8mA / 1.6mA 1.2mA / 2.4mA 1.2mA / 2.4mA 1.2mA / 2.4mA 1.2mA / 2.4mA Parameter ±0.1% (reading + range) at 50/60Hz rms, Max, Min, +/-pk POWER READBACK WATTMETER Range 1875W 2800W 2800W 3750W 3750W Resolution 0.03125W 0.05W 0.05W 0.0625W 0.0625W A Meter ±0.1% of (reading + range) rms Arms Correspond To rms and Arms Range 5600W 7500W 11250W 15000W 18750W 22500W Resolution 0.1W 0.125W 0.1875W 0.25W 0.3125W 0.375W A Meter ±0.2% of (reading + range) rms Arms Correspond To rms and Arms MSCELLANEOUS POWER FACTOR METER Range ±0.000-1.000 ±{0.002 ± (0.001/PF) F} FREQUENCY METER Range 0.1% DC, 40-440Hz METERS FOR OTHER PARAMETERS alues A, AR, CF_, peak, max., min., max., min., HD, HD, THD, THD PROTECTON STANDARD FEATURES Over Power Protection 1968.75Wrms or 2940Wrms or 2940Wrms or 3937.5Wrms or 3937.5Wrms or Over Protection 19.687Arms or 19.687Arms or 29.4Arms or 29.4Arms or 39.375Arms or Over Protection 367.5rms / 525dc Over Temperature Protection Yes Over Power Protection 5880Wrms or 7875Wrms or 11812.5Wrms or 15750Wrms or 19687.5Wrms or 23625Wrms or Over Protection 58.8Arms or 78.75Arms or 118.125Arms or 118.125Arms or 118.125Arms or 118.125Arms or Over Protection 367.5rms / 525dc Over Temperature Protection Yes Every effort is made to ensure that the information provided within this technical summary is accurate. However, ETPS Ltd must reserve the right to make changes to the published specifications without prior notice. Where certain operating parameters are critical for your application we advise that they be confirmed at the time of order. ETPS Ltd specialises in modifying its proven platforms to suit your needs. Please contact our office if your requirement is non-standard. Please note that your actual unit may differ from those shown. WWW.ETPS.CO.UK

WE ARE POSTE PEOPLE ETPS engineer electronic power supply and testing systems. Our problem solving skills provide the spark of innovation to some of the world s leading technology brands. Tel: +44 (0) 1246 452909 Sales: 0800 612 95 75 sales@etps.co.uk www.etps.co.uk ETPS Ltd Unit 14, The Bridge Beresford Way, Chesterfield S41 9FG POSTE PROBLEM SOLNG