Univox CLS-5. Environment-friendly loop amplifier for TV rooms and installations in elevators/buses. Installation Guide

Similar documents
Univox CLS-5. Environmental friendly loop amplifier for TV rooms and installations in elevators/buses. Installation Guide

PLS-700 Univox Loop driver Installation Guide

Univox Loop Listener. Loop receiver and testing device. User Guide. Univox Loop Listener Part No /230453

Univox P-Loop 2.0. Portable loop case. User Guide. Univox P-Loop 2.0 Part No

Univox CLS-1. Compact and powerful induction loop amplifier for TV/music/microphone. User Guide. Art.nr

CTC-systems. Cross-The-Counter Loop System. Installation Guide

Univox P-Loop 2.0. Portable loop case. User Guide. Univox P-Loop 2.0 Part No

Univox FSM 2.0. Multitone Field Strength Measurement Microprocessor controlled. User Guide. FSM 2.0, Part No

Univox SLS-1/3/5 Class D Tech Series State of the art phased array loop drivers

UniVox CTC Loop amplifier for cross-the-counter systems

Univox PLS-X1, X3, X5

DL102 Counter Loop Amplifier

PLA-240. Small Room Loop Amplifier System. USER Manual MAN 211A

LA-SERIES LOOP AMPLIFIERS. Item ref: UK, UK User Manual

DL50/K AUDIO-FREQUENCY INDUCTION LOOP KIT

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

RU210. Dual Multi-UHF Wireless System. Item ref: UK, UK User Manual. Version 1.0

Active Antenna Combiner ACA 1. Instruction manual

NU2. Dual UHF Wireless System. Item ref: UK, UK, UK, UK User Manual. Version 1.0

Single Channel Radio Mic System USER MANUAL. WMU-116-H (Hand Held) WMU-116-B (Belt Pack) Single Channel Radio Mic System

D C 01/2019 3

a Loop System LA240 User manual ACCESS TO SOUND

Manual and User Guide

i3speakers LX503 MK2 User Manual

MINI MCR-SL-UI-I-LP-NC

-AMp. Gpt 60-Iv. hearing LOOp AMpLIFIErs 60VA INDUCTION LOOP AMPLIFIER. gpt. DESIGnS manufacturing Excellence Through Engineering

PA WATT PORTABLE PA SYSTEM PRODUCT MANUAL

EPA152/252/502. User Manual.

ECI 6D. Balanced Integrated Amplifier. Owner's Manual. (with a built-in DAC) ENGLISH

12V MINI AUDIO-FREQUENCY INDUCTION LOOP AMPLIFIER

Domestic Loop System (DLS)

19'' Rack Mount 300 Watt Power Amplifier/ Mixer w/70v Output & Mic Talkover USER MANUAL

EPA104/254. User Manual.

Mixer Amplifier series

V-SERIES. VHF Wireless Systems User Manual. Version 2.0

RXA 1000 D CLASS D MONO AMPLIFIER USER S MANUAL

Thank you for purchasing a qualiton A20i power amplifier!

PA240 ORDERCODE D6113

ECA COMMERCIAL AMPLIFIER OWNER S MANUAL ECA-70MIXAMP V / 70V / 4Ω Amplifier ECA-70MIXAMP-1-60 OUTPUT LEVEL POWER MASTER MIC 1

Ver Tornado KT2 - KT2C KTL2 - KTL2C. USER GUIDE English KT2 KTL2 KT2C KTL2C

AC/DC Current Oscilloscope Probe Model SL261

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

USER GUIDE English. Tornado KT2 - KT2-HV KT2C - KT2C-HV KTL2 - KTL2-HV KTL2C - KTL2C-HV KT2 - KT2-HV KTL2 - KTL2-HV KT2C - KT2C-HV KTL2C - KTL2C-HV

Z44R. Multi-purpose Rack Mixer. Item ref: User Manual

INSTRUCTION MANUAL UTL260

ZM-6. Professional 19 Rack Mixer USER MANUAL. Content

LT-800 Stationary Transmitter

PDA103 AUDIO-FREQUENCY INDUCTION LOOP AMPLIFIER

ZM 84 Audio Mixer. User Manual. Order code: CRAM41. Audio Mixer ZM 84 AUX 3 AUX 1 AUX 2 AUX 4 MASTER 1 MASTER 2 OFF BASS BASS TREBLE TREBLE BASS BASS

DA216S DISTRIBUTION AMPLIFIER

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

User Manual. MA 21 Two zone mixing amplifier

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

80i-110s AC/DC CURRENT PROBE

DPA-1200 ORDERCODE D4180 DPA-2400 ORDERCODE D4181 DPA-3400 ORDERCODE D4182

4020B. Operating Manual

V6 V10 V35 V45 V218-S V221-S

EQ-AMP60 60W Mixer Amplifier

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

USER MANUAL OF INDUCTION LOOP AMPLIFIER TYPE: WPI

Digital Clamp Meter Model: &

R-Series R235LS 2-Channel Power Amplifier with Local Source Switching

DVM1190 DIGITAL MULTIMETER

Thank you for purchasing a qualiton A50i power amplifier!

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

Operating instructions D-37

PowerMatch PM8500 / 8500N TECHNICAL DATA SHEET. configurable power amplifier. Key Features. Product Overview. Applications

KWM Quartet Wireless microphone system

User Manual VOLUME PTT 1 MIC/LINE 2 MIC/LINE 3 MIC/LINE 4 MIC/LINE 5 MIC/LINE 6 MIC/LINE 7 MIC/LINE 8 MIC/LINE 9 MIC/LINE 10 LEVEL LEVEL TREBLE 6 MIC

Digital automotive analyser 13 function with ic

Professional Power Amplifier HORIZON SERIES USER MANUAL. Content

AMP-13 OPERATOR S MANUAL

AD U DAB/FM Tuner. Item ref: UK User Manual

Ref. Nr WI-DMX WIRELESS TRANSCEIVER MANUAL

SA 125 mixer amplifier. user manual

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

200Amp AC Clamp Meter + NCV Model MA250

User s Manual. Ground Resistance Clamp On Tester MODEL

Instruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46

411LA Broadband Power Amplifier

MDW-45 Converter RS RS-422/485

User s Guide. Model MA A AC Mini Clamp-on Meter

The Future of Sound. Made Perfectly Clear.

Installation Guide & User Manual Sound Plus Infrared System, Model WIR 950

Studio. PRO High Performance Professional Audio MODEL:PA105/PA205 PA AMPLIFIER

Thank you very much for choosing Shuguang Audio Classic Series vacuum tube amplifier

AC Active Transmitter Combiner 8:1

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

A Channel Amplifier

E-400 power amplifier. user manual

RMO500 M I C R O O H M M E T E R

On-Line Cardio Theater Wireless Digital Transmitter Installation and Instruction Manual

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

PTA3 2X75 Watt Stereo Power Amplifier

E-800 power amplifier. user manual

3B SCIENTIFIC PHYSICS

NSPL-500. AIS/VHF antenna splitter. User Manual ENGLISH.

Synthesized Base Station Transmitter

Important Safety Information

Transcription:

Univox CLS-5 Environment-friendly loop amplifier for TV rooms and installations in elevators/buses Installation Guide Univox CLS-5, art nr 212012 1

Content Introduction........ 3 Product overview........ 4 Features and controls.... 5 User information........ 5 System check/troubleshooting.... 5 Product maintenance and care.... 6 Mounting and placement........ 6 Installation setup........ 6 Default settings........ 6 Special settings for TV connection........ 7 Connecting an alert signal........ 7 Loop installation guidance........ 8 Technical description........ 9 Power.... 9 Loop Output.... 9 Inputs.... 9 Indication.... 9 Metal loss correction/treble control.... 9 Loop current.... 9 Indicators.... 9 Safety and Warranty....... 10 Troubleshooting....... 10 Service....... 10 Technical data....... 11 Environment and Recycling....... 11 Measuring devices....... 11 Accessories....... 11 2

Introduction Thank you for purchasing Univox CLS-5 loop amplifier. We hope you will be satisfied with the product! Please read this user guide carefully before installation and usage of the product. Univox CLS-5 is a modern loop amplifier designed for wireless listening through T-coil equipped hearing devices. Wide range of operating voltages,110-240 VAC and 12-24 VDC, supports its suitability for a number of applications, from on board vehicles to large TV lounges and meeting rooms. Digital and coaxial inputs, adjustment of time delay between the audio and video (TV Sync), and built-in automatic SCART control are some of the features that enables easy connection and operation with modern flat screen plasma- and LED/LCD TVs. 50% lighter, with 98% efficiency and 90% reduction of copper, compared to traditional amplifiers, CLS-5 is one of the most environment-friendly loop drivers on the market. CLS-5 features high-current output, essential for optimal signal broadcasting, and correctly installed provides compliance with all the requirements of IEC 60118-4 and relevant automotive standards. 3

Product overview Front panel 9. 10. 5. Rear panel 1. 6. Side 12. 13. 4. 7. 3. 8. 2. 11. Terminal block 4

Features and controls 1. On/Off. Yellow led indicates that the amplifier is connected to the mains power 2. In. Green led indicates that the amplifier is connected to the mains power and to a signal source (TV, DVD, radio, etc.) 3. Loop. Blue led indicates that the current is delivered to the loop, i.e. the sound is transmitting to hearing aids. The led is illuminated only when the signal is transmitted from the source 4. Loop connection terminal. Connections to loop wire, terminal 1 and 2 5. TV Sync. Potentiometer for adjustment of time delay between the audio and video signal 6. Loop current adjustment. Potentiometer for adjustment of loop current 7. In 3. RCA/Phono 8. Potentiometer for adjustment of microphone sensitivity 9. SCART connector for TV 10. SCART connector Ext, for VHS/DVD player etc 11. Microphone input 12. Digital input, optical 13. Digital input, coax User information CLS-5 should be installed and adjusted by a qualified technician. No maintenance is normally required. In the event of technical problems, do not attempt to adjust the amplifier yourself. System check/troubleshooting 1. Check that the amplifier is connected to the mains power (yellow LED illuminated). Proceed to step 2. 2. Check the input connections. The cable between the amplifier and the signal source/s (TV, DVD, radio etc.) must be properly connected, (green LED In illuminated). Proceed to step 2. 3. Check the loop cable connection, (blue LED). The LED is illuminated only if the amplifier is transmitting sound to the hearing aid and the system is working correctly. If you are not receiving an audio signal in your hearing aid, verify that the hearing aid is functioning properly and is set in T-position. 5

Product maintenance and care Under normal circumstances the product does not need any special maintenance. Should the unit become dirty, wipe it with a clean damp cloth. Do not use any solvents or detergents. Mounting and placement CLS-5 can be wall-mounted (see template for wall mounting at the end of this Installation Guide) or placed on a flat and stable surface. The wires between the loop figuration and the driver should not exceed 10 meters and should be paired or twisted. Important! The location must provide adequate unit ventilation. The amplifier normally generates heat during operation and needs free space for plenty of ventilation on all sides. To prevent fire, overheating or discoloration of the nearby objects, the amplifier should not be placed close to fragile and easily flammable materials. Installation setup 1. Connect the loop wire to the amplifier s loop connection terminal marked Loop (4.). 2. Connect a suitable input signal source. 3. Connect the amplifier to mains or a 12-24V DC power source. Yellow LED (1.) illuminated. Default settings 1. Check that there is an input signal, green LED In (2.) illuminated. 2. If microphone is connected to Mic input, adjust the microphone sensitivity (11.). Adjust the microphone sensitivity (8.) so the green LED In (2.) is illuminated during the program peaks. 3. Adjust the magnetic field strength by turning the loop current potentiometer Loop (6.) until the program peaks reach 0dB, (400 ma/m). Verify the field strength with Univox FSM field strength meter enabling RMS measurement and 125 ms integration time. Check the sound quality with the loop receiver, Univox Listener. Some installations require adjustment of treble level. The treble control is located inside the CLS-5 (single control potentiometer inside the unit). When increasing the treble there is an increased risk of self-oscillation and distortion. 6

Special settings for TV connection Digital In (12-13.) Connect with optical or coax cable to TV models with digital output. RCA/phono (7.) Connect the TV's audio output (AUDIO OUT or AUX OUT) to In 3 RCA/Phono (7.) SCART (9-10.) Check that the TV s SCART system works, i.e. the TV switches the mode automatically when a connected externall unit (DVD etc.) is turned on. Disconnect the SCART cable from the TV and connect it to the output Ext (10.) on the CLS-5 unit. Connect an additional SCART cable between the SCART output on the TV and the SCART input (9.) on the CLS-5. Sound adjustment/tv Sync (5.) For adjustment of time delay between the audio and video signal use the TV sync adjustment potentiometer. Connecting an alert signal The alert signal system can be triggered in three ways: 1. External Doorbell drive: +24VDC Doorbell. Terminal 3-6 on the terminal block 2. External trigger: 5-24V AC/DC. Terminal 4-5 on the terminal block 3. External switch: Terminal 3-4 and 5-7 are shorted separately. The external switch is connected between 3-4 and 5-7. The acoustic indication suppresses the sound in the loop and initiates a broadband harmonic sound that covers most of the non-linear frequency hearing impairments. 7

Loop installation guidance The installation should initially be planned with a 2 x 1.5 mm² paired wire. Connect the wires in series as a 2-turn loop. If the desired field strength is not achieved, connect the wires in parallel creating a 1-turn loop. In installations where a standard round wire is not suitable e.g. due to the limited space, a flat copper foil is recommended. Venues with reinforced structures can reduce the coverage area significantly. Analog signal cables should not be placed closely or in parallel to the loop wire. Avoid dynamic microphones to reduce the risk of magnetic feedback. The loop should not be installed closely to or directly on metal constructions or reinforced structures. Otherwise, the field strength might be reduced substantially. If the shortest side of the loop area is longer than 10 meters, a figure eight loop configuration should be applied. Verify that the overspill outside of the loop is acceptable. If not, a Univox SLS system should be installed. Relocate the electrical equipment that could create background magnetic field signals or interference with the loop system. In order to avoid feedback from electronic instruments and dynamic microphones, do not install wire near the stage area. A completely installed loop system should be tested with Univox FSM field strength meter and certified according to the IEC 60118-4 standard. Univox Certificate of conformity, including a measurement procedure checklist, is available at www.edin.se/support. 8

Technical description Power Built-in switched power supply 110-240VAC 12-24VDC as primary power supply or backup. Connection to 12V DC will reduce the effect Loop Output Max current 10 Arms, short-circuit driven Max voltage 24 Vpp (open output) Frequency range 70-5000 Hz (±3dB) Distortion <1% at 1 Ω DC and 80 μh Connection Phoenix screw terminal Inputs Digital Mic TV/Ext In 1 In 2 In 3 Optical/Coax 3.5 mm, 2-250 mv/5 kω (built-in phantom power) SCART, 35 mv-10 V/ 5kΩ screw terminal, 35 mv-10 V/5 kω screw terminal, 25 mv-10 V/5 kω RCA/phono, 35 mv/330 Ω Indication External door bell/telephone signal or trigger voltage can activate the built-in alerting system with tone generator in the loop. Metal loss correction/treble control 0 to +18dB correction of high frequency attenuation - screw driver control. Loop current Loop current (6.) Screwdriver adjusted Indicators Power connection Yellow LED (1.) Loop current Blue LED (3.) Input signal Green LED (2.) 9

Safety and Warranty The equipment should be installed by an audio visual technician observing 'good electrical and audio practice' at all times and following the instructions within this document. Connect the power to the amplifier before connecting to the network, otherwise there is a risk of sparking. The installer is responsible for installing the product in a way that may not cause risk of fire, electrical malfunctions or danger for the user. Do not cover the loop driver. Only operate the unit in a well ventilated, dry environment. There are no user serviceable parts inside the unit. Refer servicing to qualified personnel. Please observe that the product warranty does not include faults caused by tampering with the product, carelessness, incorrect connection/.mounting or maintenance. Bo Edin AB shall not be held responsible or liable for interference to radio or TV equipment, and/or to any direct, incidental or consequential damages or losses to any person or entity, if the equipment has been installed by unqualified personnel and/or if installation instructions stated in the product Installation Guide have not been strictly followed. Troubleshooting Check the LED indicators and run the troubleshooting procedure according to sections Technical Description, System check/troubleshooting described in this installation guide. Use Univox Listener to check the sound quality of the loop. Service If the product / system is not working properly after completing the troubleshooting procedure, please contact your local distributor od Bo Edin directly for further instructions. The appropriate Service form, available at www.univox.eu, should be completed before sending any products back to Bo Edin AB for technical consultation, repair or replacement. 10

Technical data For additional information, please refer to product data sheet/brochure and CE certificate available at www.univox.eu. For other technical documentation please contact support@edin.se. Environment and Recycling In case of product disposal follow the official regulations. Measuring devices Univox FSM 2.0, Field Strength Meter Professional instrument for measurement of performance and certification of loop systems in accordance with IEC 60118-4. Univox Listener Induction loop receiver designed for fast and simple check of the sound quality and basic control of the loop level. Accessories Please refer to product brochure (pdf) available for download at www.univox.eu/products. The Installation Guide is based on the information available at the time of printing and are subject to change without notice. 11

Distributor Univox by edin, the world s leading expert and producer of high quality hearing loop systems, created the very first true loop amplifier 1969. Ever since our mission is to serve the hearing community with the highest degree of service and performance with strong focus on Research and Development for new technical solutions. cls-5-ig-gb 170426 Copyright Bo Edin AB Bo Edin AB, Stockby Hantverksby 3, SE-181 75 Lidingö, Sweden www.univox.eu Hearing excellence since 1965 12