TABLE OF CONTENTS Specifications... 2-2 QuickSpecGuide... 2-3 Elevations: Scale Single-Hung-FloridaSizes... 2-4 Grille Patterns... 2-5 SectionDetails: 6 Scale... 2-6 InstallationWallDetails... 2-10 PagethroughthePDFusingthebutonsontheright, orclickatopicabovetogodirectlytothatpage. January 2009 JELD-WEN reserves the right to change specifications without notice. Page 2-1
PRODUCT SPECIFICATIONS MATERIALS White and MB-40 bronze electrostatically applied baked polyester paint. FRAME All frames are mechanically assembled with a gasket and a secondary silicone seal for added assurance of weather tight performance. The frame jamb width is 2- (73mm), and the nominal extrusion exterior wall thickness is 0.063. The frame incorporates a 1/2 front flange for typical Florida installations into block construction. A sloped sill with weep holes are in the frame to ensure standing water is directed to the exterior plane of the unit. Optional frame types: slip-on nailing fin. SASH The single-hung sash is a nominal 1-1/8 (28.65mm) thickness. It is mechanically fastened for added strength and durability, and silicone sealed to ensure weather tight performance. GLAZING Monolithic 5/16 (7.9mm) Impact Resistant glass standard. All units are exterior glazed. Clear, LowE, LowE366, and tinted glass colors for a variety of glass options. WEATHER-STRIPPING A fin-pile weather-strip is applied to sash jamb, sash interlocks, and main head/sill. HARDWARE A single action cam style lock is available on all windows. Block and Tackle balance systems are utilized to support the vertical operation of the sash. Head/Sill latches are standard. INSECT SCREENS The exterior fiberglass charcoal color insect screen is set in an aluminum frame to match the color of the unit. The spring loaded screen system assists in keeping it secured to the window. Insect screens are intended to allow air and light in and keep insects out. They are not intended to keep anyone or anything from falling through an open door or window. For safety screens or other security devices contact your local building supply retailer. GRILLES SDL (Simulated Divided Lite) (25.4mm) vinyl contour outside/flat inside muntins surface mounted on the exterior surfaces of the single glaze glass unit to provide a true divided lite appearance. Only available in white. DA (Double Applied) - Aluminum double applied flat/flat bar is applied to the exterior of the single glazed glass to give the detail of a true divided look. ADDITIONAL ACCESSORIES Please contact your local building supply retailer for a complete listing of the additional accessories. See www.jeld-wen.com/ findsupplier. INSTALLATION See www.jeld-wen.com/resources for instructions. PERFORMANCE Please reference www.jeld-wen.com/performanceratings for up to date Design Pressure and approval information. January 2009 JELD-WEN reserves the right to change specifications without notice. Page 2-2
QUICK SPEC GUIDE SPECIFICATION STANDARD FEATURES OPTIONAL FEATURES Some options may require additional lead times. Consult your JELD-WEN Sales Representative. COLOR S White S Bronze SIZE S Width: 18-52-1/8 S Height: 23-75 FRAME S 1/2 Flange S Slip-On Fin GLAZING S 5/16 PVB Mono IMPACTGARD PROTECTION S Only available with ImpactGardt Protection PVB Impact PVB impact not available in Low-E. HARDWARE S Cam-Lock S Block & Tackle Balance HARDWARE COLOR S Matches Frame SCREENS S Fiberglass SCREEN FRAME COLOR S Matches Frame S Tempered S Obscure S Bronze S Azurlite S Gray S Graylite (Turtle) S Green S Bronze Reflective S SGP Impact Single-Glaze Not available in tempered. All other tint and obscure glazing options apply. GRILLES S SDL - Simulated Divided Lite available only in white and only on impact resistant units S Double Applied Flat/Flat Bar JAMB S 2- January 2009 JELD-WEN reserves the right to change specifications without notice. Page 2-3
SINGLE-HUNG FLORIDA SIZES - IMPACT UNIT SIZE ROUGH OPENING FRAME SIZE DAYLIGHT OPENING 20 5/8 (524) 18 1/8 (460) 18 1/8 (460) 12 13/16 (325) 28 (711) 25 1/2 (648) 25 1/2 (648) 20 5/16 (515) 38 1/2 (978) 36 (914) 36 (914) 30 11/16 (779) 54 5/8 (1387) 52 1/8 (1324) 52 1/8 (1324) 46 13/16 (1189) 27 1/2 (699) 25 (635) 25 (635) 8 1/16 (205) 7 1/2 (191) 60* 60* 60* 60* 6SH-12 6SH-H32 6SH-22 6SH-32 39 (1013) 37 3/8 (949) 37 3/8 (949) 14 (362) 13 11/16 (348) 60* 60* 60* 60* 6SH-13 6SH-H33 6SH-23 6SH-33 60* 60* 60* 60* 77 1/2 (1969) 75 (1905) 75 (1905) 33 1/16 (840) 32 1/2 (826) 73 1/2 (1867) 7(1803) 7(1803) 31 1/16 (789) 30 1/2 (775) 64 1/2 (1638) 62 (1575) 62 (1575) 26 1/16 (662) 25 1/2 (648) 52 1/8 (1324) 49 5/8 (1260) 49 5/8 (1260) 20 3/8 (518) 19 13/16 (503) 6SH-14 6SH-H34 6SH-24 6SH-34 60* 60* 60* 60* E E 6SH-15 6SH-H35 6SH-25 6SH-35 60* 60* 60* 60* E E 6SH-16S 6SH-H36S 6SH-26S 6SH-36S 60* 60* 60* 60* E E 6SH-16 6SH-H36 6SH-26 6SH-36 ELEVATION SYMBOL LEGEND: VALUES IN () ARE IN MILLIMETER CONVERSIONS ##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING. E UNIT MEETS EGRESS REQUIREMENTS FOR IRCCODE. STATE ANDLOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCALBUILDING CODES FOR COMPLETE REQUIREMENTS. CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT. SCALE: = 1 January 2009 JELD-WEN reserves the right to change specifications without notice. Page 2-4
GRILLE PATTERNS STANDARD PRAIRIE PRAIRIE SASH COLONIAL TOP SASH COLONIAL TOP SASH 1/2 LITE January 2009 JELD-WEN reserves the right to change specifications without notice. Page 2-5
SINGLE-HUNG FLANGE - IMPACT 2 13/16 1 13/16 3/4 1/2 15/8 Screen Size Unit Size Daylight Opening Frame Size Daylight Opening 1 5/16 1 5/16 13/16 1 5/16 1 3/16 9/16 1 13/16 2 13/16 January 2009 VERTICAL SECTION SCALE: 6 = 1 JELD-WEN reserves the right to change specifications without notice. Page 2-6
SINGLE-HUNG FLANGE - IMPACT Frame Size 3/4 3/4 Daylight Opening 13/4 13/4 23/4 23/4 1/16 Daylight Opening 1/16 13/8 13/8 Screen Size Unit Size HORIZONTAL SECTION January 2009 SCALE: 6 = 1 JELD-WEN reserves the right to change specifications without notice. Page 2-7
SINGLE-HUNG NAIL FIN - IMPACT 2 13/16 13/4 3/4 1/2 15/8 Screen Size Daylight Opening Daylight Opening Unit Size Frame Size 1 5/16 1 5/16 13/16 1 5/16 1 3/16 9/16 13/4 January 2009 2 13/16 VERTICAL SECTION SCALE: 6 = 1 JELD-WEN reserves the right to change specifications without notice. Page 2-8
SINGLE-HUNG NAIL FIN - IMPACT Frame Size 3/4 3/4 Daylight Opening 1 11/16 1 11/16 23/4 23/4 1/16 Daylight Opening 1/16 13/8 13/8 Screen Size Unit Size HORIZONTAL SECTION January 2009 SCALE: 6 = 1 JELD-WEN reserves the right to change specifications without notice. Page 2-9
INSTALLATION WALL DETAIL CMU SEALANT AND BACKER ROD LOW EXPANSION FOAM INSTALLATION: Doors and windows to be installed per latest revision of ASTM E2112. STANDARD PRACTICE FOR INSTALLATION OF EXTERIOR WINDOWS, DOORS AND SKYLIGHTS. Weather plane flashing must provide a continuous seal between weather plane of fenestration product and weather plane of wall system. DRAIN MAT, TO TERMINATE OVER CONTINUOUS MOISTURE BARRIER (WEATHER PLANE OF BUILDING) Frame Size All metal to metal joints must be sealed after installation, this includes, but is not limited to drip caps and mullion covers. Job site Frame to Frame Mull joints must be silicon sealed between frames. JELD-WEN recommends all window products be installed with a sill pan or equivalent must include back dam and side dams @. NOTE: Please refer to the JELD-WEN web site for installation instructions at: www.jeld-wen.com SEALANT AND BACKER ROD WINDOW SECURED WITH ANGLE BRACKET 7 MIN. SLOPE WOOD TRIM VERTICAL SECTION Frame Size SEALANT & BACKER ROD LOW PRESSURE FOAM HORIZONTAL SECTION Details shown are for representation only and intended to reflect basic installation concepts. Proper installation and maintenance of JELD-WEN products are essential if optimum performance is to be fully attained. Written installation instructions that provide guidelines are available on our website at www.jeld-wen.com/resources. January 2009 JELD-WEN reserves the right to change specifications without notice. Page 2-10
INSTALLATION WALL DETAIL LAP SIDING SEALANT CONTINUOUS MOISTURE BARRIER CONTINUOUS SEALANT BEHIND NAIL FIN, ALL SIDES, BY OTHERS SELF-ADHESIVE FLASHING OVER NAIL FLANGE CONTINUOUS SEALANT AND BACKER ROD LOW EXPANSION FOAM INSTALLATION: Doors and windows to be installed per latest revision of ASTM E2112. STANDARD PRACTICE FOR INSTALLATION OF EXTERIOR WINDOWS, DOORS AND SKYLIGHTS. Weather plane flashing must provide a continuous seal between weather plane of fenestration product and weather plane of wall system. All metal to metal joints must be sealed after installation, this includes, but is not limited to drip caps and mullion covers. Frame Size Job site Frame to Frame Mull joints must be silicon sealed between frames. JELD-WEN recommends all window products be installed with a sill pan or equivalent must include back dam and side dams @. NOTE: Please refer to the JELD-WEN web site for installation instructions at: www.jeld-wen.com DRAIN MAT, TO TERMINATE OVER CONTINUOUS MOISTURE BARRIER (WEATHER PLANE OF BUILDING) CONTINUOUS BEAD OF SEALANT BETWEEN NAIL FIN AND DRAIN MAT CONTINUOUS SEALANT AND BACKER ROD CONTINUOUS MOISTURE BARRIER THRU WALL FLASHING WOOD SILL AND TRIM VERTICAL SECTION Frame Size SEALANT & BACKER ROD LOW PRESSURE FOAM HORIZONTAL SECTION Details shown are for representation only and intended to reflect basic installation concepts. Proper installation and maintenance of JELD-WEN products are essential if optimum performance is to be fully attained. Written installation instructions that provide guidelines are available on our website at www.jeld-wen.com/resources. January 2009 JELD-WEN reserves the right to change specifications without notice. Page 2-11
INSTALLATION WALL DETAIL STUCCO CONTINUOUS MOISTURE BARRIER CONTINUOUS SEALANT BEHIND NAIL FIN, ALL SIDES, BY OTHERS INSTALLATION: Doors and windows to be installed per latest revision of ASTM E2112. STANDARD PRACTICE FOR INSTALLATION OF EXTERIOR WINDOWS, DOORS AND SKYLIGHTS. SELF-ADHESIVE FLASHING OVER NAIL FLANGE CONTINUOUS SEALANT AND BACKER ROD LOW EXPANSION FOAM Weather plane flashing must provide a continuous seal between weather plane of fenestration product and weather plane of wall system. All metal to metal joints must be sealed after installation, this includes, but is not limited to drip caps and mullion covers. Frame Size Job site Frame to Frame Mull joints must be silicon sealed between frames. JELD-WEN recommends all window products be installed with a sill pan or equivalent must include back dam and side dams @. NOTE: Please refer to the JELD-WEN web site for installation instructions at: www.jeld-wen.com DRAIN MAT, TO TERMINATE OVER CONTINUOUS MOISTURE BARRIER (WEATHER PLANE OF BUILDING) CONTINUOUS BEAD OF SEALANT BETWEEN NAIL FIN AND DRAIN MAT CONTINUOUS SEALANT AND BACKER ROD CONTINUOUS MOISTURE BARRIER WOOD SILL AND TRIM VERTICAL SECTION Frame Size CONTINUOUS SEALANT AND BACKER ROD LOW PRESSURE FOAM HORIZONTAL SECTION Details shown are for representation only and intended to reflect basic installation concepts. Proper installation and maintenance of JELD-WEN products are essential if optimum performance is to be fully attained. Written installation instructions that provide guidelines are available on our website at www.jeld-wen.com/resources. January 2009 JELD-WEN reserves the right to change specifications without notice. Page 2-12