Installation and Operational Instructions for ROBA -switch Type 017._00.2

Similar documents
Installation and Operational Instructions for ROBA -switch Type 017._00.2

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Installation and Operating Instructions for Phase Demodulator Type _.2

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

QUINT-PS/ 3AC/24DC/10

QUINT-PS/ 3AC/24DC/40

Power supply CP-D 12/2.1

Power supply CP-E 24/0.75

QUINT-PS AC/24DC/40

Power supply CP-D 24/4.2 Primary switch mode power supply

Reliable control of DC consumers

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-D 24/1.3

Power supply CP-T 24/10.0 Primary switch mode power supply

MINI-PS AC/24DC/1.3

QUINT-PS-24DC/24DC/10

QUINT-PS/ 1AC/24DC/20

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-E 24/2.5

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Power supply CP-T 24/20.0 Primary switch mode power supply

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Installation and Operational Instructions for primeflex -couplings Types 933._33.1 / 933._35.1 / 933._66.1 / 933._67.1

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Power supply CP-T 48/20.0 Primary switch mode power supply

Type CP-S, CP-C & CP-A Switch mode

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Liquid level monitoring relay CM-ENS.2x

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

PHOENIX CONTACT - 09/2009

Zelio Control Measurement Relays

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-SDD.22

Installation and Operational Instructions for ROBA -DX Couplings Type 931.3

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Power supplies CBC 140-T, CBC 140-1, CBC and CBC 140-5

ESwitch. User Guide. Power Contactor

Instruction manual for STA 1 sectional door operator

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

MINI MCR-SL-UI-f(-SP)

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

E-STOP relays, safety gate monitors

Electronic timer CT-TGD.22

Electronic timer CT-SDS.22

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

CP-T range Product group picture

Instruction manual for STA 1 sectional door operator

Power Supplies 3. SDN-C Compact DIN Rail Series

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

MINI MCR-SL-UI-I-LP-NC

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Thyristor power controller B DI1002 V1.0 Manual/Operating instructions

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

MINI-PS AC/2X15DC/1

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

E-STOP relays, safety gate monitors

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Electronic Circuit Protector ESX10-T

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

CP-T range Benefits and advantages

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Thermistor motor protection relays

Switching power supplies CP range, Linear power supplies CP-L range. Content

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Product Data Sheet 8452/2HHP. The engineer's choice

38 Series - Relay interface modules A

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

48 Series - Relay interface modules A. Features

02/11/2015

OPTITEMP TT 10 C/R Technical Datasheet

38 Series - Relay interface modules A

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

Transcription:

Manufacturer s Declaration This product is intended for installation in a machine or system, based on the machine directive 2006/42/EC. It is forbidden to start use of the product until the machine or system into which it should be built is operating in accordance with the EC directives. The product corresponds to the low voltage directive 2006/95/EC. Safety egulations To prevent injury or damage, only professionals and specialists should work on the devices, following the relevant standards and directives. Please read the Installation and Operational Instructions carefully before installation and initial operation of the devices. Danger of death on touching voltage-carrying cables and components Danger of device failure caused by short circuits or earth short circuits at the terminals Electronic devices cannot be guaranteed fail-safe Danger of burns when touching hot surfaces Warning: Without a conformity inspection, this product is not suitable for use in areas where there is a danger of explosion. This statement is based on directive 94/9/EC (ATEX directive). Application OBA -switch fast acting rectifiers are used to connect DC consumers to alternating voltage supplies, for example electromagnetic brakes and couplings (OBA-stop, OBA - quick, OBATIC ) as well as electromagnets and electrovalves etc. Fast acting rectifier OBA -switch 017._00.2 Consumer operation with overexcitation or power reduction Input voltage: 100-500 VAC Maximum output current: I MS: 3 A at 250 VAC UL-approved Function The OBA -switch units are used for operation at an input voltage of between 100 and 500 VAC, dependent on Type. They can switch internally from bridge rectification output voltage to half-wave rectification output voltage. The bridge rectification time can be modified from 0,05 to 2 seconds by exchanging the external resistor. Electrical Connection (Terminals) 1 + 2 Input voltage (built-in protective varistor) 3 + 4 Connection for external contact for DC-side switch-off (with an installed bridge, switch-off only takes place Aside with a longer brake engagement time) 5 + 6 Output voltage (built-in protective varistor) 7 + 8 MS for bridge rectifier timing adjustment Dimensions (mm) Type 017.000.2 5,6 5 Ø4,5 64 4,5 15 9 48,6 30 17,5 Accessories: Mounting bracket set for 35mm rail acc. EN 50022 Article No. 1802911 13 Type 017.100.2 5 Ø4,5 9 5,6 30 17,5 4,5 64 Accessories: Mounting bracket set for 35mm rail acc. EN 50022 Article No. 1802911 20 73,6 15 69 Page 1 of 5

Technical Data Type Size 10 20 10 20 Input voltage 100-250 VAC ±10 % Output voltage (0,9 x U AC) U bridge Output voltage (0,45 x U AC) U half-wave Output current at 45 C I MS Output current at max. 70 C I MS Built-in protective varistors U MS 200-500 VAC ±10 % 100-250 VAC ±10 % 200-500 VAC ±10 % 90-225 VDC 180-450 VDC 90-225 VDC 180-450 VDC 45-113 VDC 90-225 VDC 45-113 VDC 90-225 VDC 2,0 A 1,8 A 3,0 A 2,0 A 1,0 A 0,9 A 1,5 A 1,0 A 275 V 550 V 275 V 550 V Conformity markings UL, CE UL up to 300V, CE UL, CE UL, CE Device fuses FF 5 A (H) 5 x 20 mm FF 4 A (H) 6,3 x 32 mm FF 6,3 A (H) 5 x 20 mm FF 5 A (H) 6,3 x 32 mm Protection IP65 components, IP20 terminals, IP10 ext Terminals Nominal cross-section 1,5 mm² (AWG 22-14), screws M3, max. tightening torque 0,5 Nm Ambient temperature -25 C up to +70 C Storage temperature -40 C up to +105 C Installation conditions The installation position can be user-defined. Please ensure sufficient heat dissipation and air convection! Installation near to sources of intense heat is not allowed! Wiring Example (400 VAC, AC-side switching) L3 OBA -switch 200-300V~ : AC-side switching means low-noise switching; however, the brake engagement time is longer (c. 6-10 times longer than with DC-side switch-off). Use for non-critical braking times. + IN S DC OUT M 3 ~ Wiring Example (400 VAC, DC-side switching) L3 OBA -switch 200-300V~ : IN S DC OUT + DC-side switching means short brake engagement times (e.g. for EMEGENCY STOP operation). However, this produces louder switching noises. Protective Circuit When using DC-side switching, the coil must be protected by a suitable protective circuit according to VDE 0580, which is already integrated in mayr rectifiers. Nevertheless, the high voltage induced on circuit interruption produces switching sparks, which lead to contact consumption. Therefore, only use the main contacts of a contactor suitable for inductive loads with a minimum contact opening of 3mm for switching the DC-side contact S DC. Connecting the main contacts in series reduces wear. M 3 ~ Page 2 of 5

Switch-ON Switch-on always takes place AC-side. Only then is the overexcitation activated. Switch-OFF If short switching times are required, please switch DCside. The AC-side always has to be switched as well in order to activate overexcitation. If a longer brake engagement time or a quieter switching noise is required, please switch AC-side. For this, a bridge must be inserted between terminals 3 and 4. Device fuses To protect against damage from short circuits or earth short circuits, please add suitable device fuses to the mains cable. Short circuits or earth short circuits during the overexcitation time period can lead to OBA -switch failures. After fuse elements have reacted to a malfunction, the OBA -switch must be checked for functional and operational safety (overexcitation voltage, switch-off voltage, response delay time, holding voltage). The same procedure is to be carried out after coil failure. Overexcitation On overexcitation, the brake is initially energised with a voltage higher than the inal voltage. This decreases the disconnection time t 2. Increased wear (enlarged air gap) as well as coil heat lengthen the brake disconnection time t 2. Therefore, when dimensioning the overexcitation time t over, please select at least double the disconnection time t 2 on each brake Type and size (catalogue values). Different external resistances between terminals 7 and 8 allow the adjustment of different overexcitation times. The overexcitation time has a standard adjustment of 0,45 s ±20 %. Overexcitation times Overexcitation t over (s) times ext on terminals 7 and 8 (Ohm) 0,05 0 (bridge) 0,10 22 K 0,20 82 K 0,45 221 K (standard) 0,69 390 K 0,76 470 K 0,95 680 K 1,15 1 M 1,53 2,20 M (included) 2,00 10 M 2,15 open The times printed in bold can be adjusted for delivery. For the other times, please select the respective resistances. ecovery time 100 ms The recovery time is the time the OBA -switch requires in order to reach its starting position after switch-off. Therefore, the input voltage may be switched on again at the earliest after 100 ms. During cycle operation, please take suitable measures to ensure that the recovery time of 100 ms is kept to. Page 3 of 5

Maximum Coil Capacity P MS The values stated in the Table are guideline values for a switching frequency of maximum 1 cycle per minute and for keeping to the permitted current I MS at 45 C. If the switching frequency is larger than 1 cycle per minute or if the overexcitation time t over is longer than double the disconnection time t 2, please observe the following: P MS P Calculations: The coil capacity P MS must not be larger than P or the inal current I MS which flows though the OBA -switch must not be exceeded. Otherwise, the coil and the OBA -switch may fail due to thermic overload. P MS (W) Effective coil capacity, dependent on the switching frequency, overexcitation, power reduction and switch-on time duration. P MS = P over t over + P hold t hold t tot P (W) Coil inal capacity (catalogue values or Type tag) P over (W) Coil capacity on overexcitation U 2 over ( ) P over = P U P hold (W) Coil capacity on power reduction U 2 hold ( ) P hold = P U t over (s) Overexcitation time t hold (s) Time of operation with power reduction t off (s) Time without voltage t tot (s) Total time (t over + t hold + t off) U over (V) Overexcitation voltage (bridge voltage) U hold (V) Holding voltage (half-wave voltage) U (V) Coil inal voltage I MS (A) Effective current, dependent on switching frequency, overexcitation time and switch-on duration I MS = PMS P U ² Table: Maximum Coil Capacity (in Watt) Size 10 / U AC 115 VAC Coil inal voltage 45 C 70 C 45 C 70 C Index 104 VDC 416 208 624 312 2 Size 10 / U AC 230 VAC Coil inal voltage 45 C 70 C 45 C 70 C Index 104 VDC 208 104 312 156 1 180 VDC 623 312 935 437 3 207 VDC 824 412 1236 618 2 Size 20 / U AC 230 VAC Coil inal voltage 45 C 70 C 45 C 70 C Index 104 VDC 187 94 208 104 1 180 VDC 561 280 623 312 3 207 VDC 742 371 824 412 2 Size 20 / U AC 400 VAC Coil inal voltage 45 C 70 C 45 C 70 C Index 180 VDC 324 162 360 180 1 207 VDC 428 214 476 238 3 225 VDC 506 253 563 281 3 Size 20 / U AC 500 VAC Coil inal voltage 45 C 70 C 45 C 70 C Index 225 VDC 405 203 450 225 1 Index 1) Operation with overexcitation 2) Operation with power reduction 3) Operation with overexcitation and power reduction Time Diagram U over U U hold 0 t on t over t hold t off Page 4 of 5

EMC-compatible Installation The OBA -switch itself does not produce any interference emissions. However, in connection with other components (e.g. electromagnetic brakes) interference emissions over the allowed limit values are possible. Therefore, EMC-compatible installation must be ensured! The described measure for keeping to the EMC directive is inspected under laboratory conditions and cannot always be automatically transferred to the state of a machine or system in case of deviations. The inspection includes the individual components mayr -OBA -switch and mayr -brake and is valid for an input voltage of up to 500 VAC. OBA -switch 200-300V~ : IN S DC OUT + Standards EMC Inspections DIN EN 61000-6-2:2006-03 Interference immunity DIN EN 61000-6-4:2002-08 Interference emission VDE 0160 / DIN EN 50178:1998-04 Equipment of high-voltage current plants with electronic machinery materials Insulation Co-ordination acc. VDE 0110 / DIN EN 60664:2003-11 Excess voltage category III Pollution degree 2 for Type 017.000.2 Pollution degree 3 for Type 017.100.2 ated insulation voltage 500 V MS Appointed Use: Acc. DIN EN 50178:1998-04 C x Installation of a C x-capacitor in the AC supply line: C x = 330 nf / 660 V = 0,5 MΩ The voltage resistance of the capacitor must be at least that of the U AC mains voltage! Discharge resistor Mount the C x-capacitor directly onto the OBA -switch (connecting terminal)! Avoid antennae effects: Keep the supply cables as short as possible, do not form ring or bow shapes with the cables! Mount good bonding connections onto the metal body of the brake! Lay control cables separately from power cables or strongly pulsating cables! Page 5 of 5