VBS TBS KTS BSS LFS UFS

Similar documents
Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones

2007 DEHN + SÖHNE / protected by ISO EXFS / 5392

German Cathodic Protection

TFS / KFSU: Isolating spark gaps with plastic coating and 2 connections (Rd 10 mm) made of stainless

7P Series - Surge Protection Device (SPD) Features 7P P P

6. Internal lightning protection

Precautions to be considered for use of surge arresters tested according to Class 1 of IEC

Test Joints / Fixed Earthing Terminals

Protection of low power mains against pulse power of natural lightning using spark gap arresters. Abstract

Title page, Product innovations Product innovations. 14 OBO Neuheiten 2016 / en / 01/03/2016 (LLExport_04360) / 01/03/2016

Earthing of Electrical Devices and Safety

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Use of application-optimised type 1 combined arresters in low-voltage installations

LF Conductivity Measuring Probe

60Hz Ratings. Typical Applications. Features & Characteristics. Ratings

Ground Clamps Cable Tray

INTERMEDIATE METAL CONDUIT

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

Protection against unacceptable voltages in railway systems

Timing Antenna Installation

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

Safety earthing. Sector Energy PTI NC. Copyright Siemens AG All rights reserved. Theodor Connor

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

Spark Gap Surge Protectors For Lv Mains

Our experience. Our products

CONTINUING EDUC ATION

Series 3401 lightning EMP protectors Gas discharge tube (GDT) technology up to 1.0 GHz

Technical Seminar for Cathodic Protection to GOGC Design Unit Specialists. Dr. Nick Kioupis, Cathodic & Lightning Protection Section Head, DESFA

TZ-RD-1740 Rotary Dipole Instruction Manual

LIGHTNING EARTHING SYSTEM : A PRACTICAL GUIDE

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

RADIO AND TELEVISION SATELLITE EQUIPMENT

INFORMATION AND CONSULTATION

Field Instruction. Induced voltages can occur in overhead lines, underground cables, or in switchyards.

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts

Energy Division. Bowthorpe LV/MV Surge Arresters

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Status Date Prepared Reviewed Endorsed Approved

iant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

INTERNATIONAL STANDARD

TECHNICAL SPECIFICATION

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

Index Pipe Hangers and Straps

Reliable System Solutions for Isolated Air-Termination Systems.

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

MEDIUM VOLTAGE PRODUCT. TJP 7.x Indoor voltage transformers

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Two-channel safety barriers Series 9002

High voltage engineering

Installation & Operating Manual. iwap202

NEW. Automation Technology 768 series

AMENDMENT NO. 1 SEPTEMBER IS (Part 1) : 2001/IEC (1991) SURGE ARRESTORS

Surge Protection and Grounding Issues

The innovation in lightning protection High-voltage-resistant, insulated HVI Conductor

Investigation of skin effect on coaxial cables

LIGHTNING ARRESTOR. September 2017 WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

PCR Polarization Cell Replacement. The Polarization Cell Replacement (PCR) Technical Literature COMMON APPLICATIONS

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Specification for Lightning Sensor

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

3EE2 Special-Purpose Surge Arresters for the Protection of Motors, Generators and Furnace Transformers

Advantages. Applications

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

Gold plating, 140 Gases compressed, 393 liquid,393 Grounding, safety, 403

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards

TECHNICAL DATA TYPE CMD OIL-IMMERSED ON-LOAD TAP CHANGER

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

Installation and Operational Instructions for ROBA -switch Type 017._00.2

SECTION - 3 EARTHING CLAMPS & FITTINGS

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Outdoor Installation 2: Lightning Protection and Grounding

Operating Instruction

Description of equipment

Tech Talk (12) Down to Earth: A Discussion of the General Requirements for the Earthing of Control and Instrumentation Systems

Tab 8 Surge Arresters

Two-channel safety barriers Series 9002

METRIC LIGHTNING PROTECTION PRODUCTS

Temperature Input Module for Zone 1 Series 9482/32

TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS CT & PT GROUP C

Use RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING

Submersible pressure sensor For oils and fuels Model LF-1

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent

OMEGA. Communications Interface Cabinet. Antenna Installation Manual

EMC Philosophy applied to Design the Grounding Systems for Gas Insulation Switchgear (GIS) Indoor Substation

Characteristics 5 TeSys k contactors and reversing contactors

Isolators A3/1. Vibration Transducer Supply Unit Series

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Local control stations for Zone 1 and Zone 21. Features. Description

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

kv AC substation

Central Inverter SUNNY CENTRAL 200 / 250 / 250HE / 350

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

Transcription:

VBS TBS KTS BSS LFS UFS TBS. Surge protection systems Order information and technical data Protection and isolating spark gaps Protection spark gap or isolating spark gap? Isolating spark gaps Protection spark gap Coupling of earthing installations

Protection spark gap or isolating spark gap? OBO isolating and protection spark gaps are intended to provide galvanic isolation between electrical installation parts that are not connected to each other for operational purposes. If the potential rises in one of the installation parts as a result of a lightning strike, the isolating spark gap guarantees a conducting connection at that time, equalising the potential between the parts. Spark gap applications: Establishing galvanic isolation of insulating flanges. Bridging of an unavoidable proximity with unacceptably small distance in a building, across an isolating spark gap, where the establishment of a direct connection is not permissible. Avoidance of the transfer of fault voltages, especially in the TT system. Gas pressure controller Isolation spark gap Isolation spark gap Type 480 Type 480 Type 481 Gas governor station (isolating spark gap for explosion hazard areas) Isolating spark gap type 480 is suitable for bridging insulating flanges or insulating fittings, especially in explosion hazard areas. Buildings with more than one earthing installation If a building has two earthing installations a foundation earthing point and a deep earthing point for example they can be connected via an isolating spark gap. This prevents electrochemical corrosion of the earthing points unlike a direct conducting connection. In addition, the entire earthing point area is effective in the event of a direct lightning strike. 100 Please always state the order number when ordering.

Degrading of one installation by another, e. g. an information installation. For this purpose, a function earth is provided, if necessary, in addition to the standard building earthing point (electrical and lightning protection). Connection of the earthing point with the earthing points of the nearby building via isolating spark gaps, especially with the TT system, in order to make use of all the earths for lightning protection. Avoidance of the transfer of fault voltages, especially in the TT system. This measure avoids the need to break connections for measurement and testing purposes. As their name implies, isolating and protection spark gaps contain a spark gap. The spark gap changes from the nonconducting to the conducting state when an arc is caused by an impulse voltage. Fuse Box function earth operational earth Overhead line connection With an overhead line connection, the roof mast of a lowvoltage overhead line should be as far as possible from the lightning protection installation. If this distance is less than half a metre, an enclosed protection spark gap must be installed. Connection to the roof mast requires the approval of the energy supply company. Buildings with more than one earthing installation If a separate earthing installation (function earth) is required for the operation of special electronic equipment, it is recommended that the earthing installations should be bridged with spark gaps for lightning protection. This prevents dangerously high voltage differences arising between the earthing installations. A choke is also installed, to keep highfrequency voltages away from the function earth. Please always state the order number when ordering. 101

Protection and isolating spark gaps Isolating spark gaps 480 and 481 Operation and fields of application Isolating spark gaps provide galvanic isolation of electrically conducting parts of an installation that must not be connected to each other. Isolating spark gap 480, for instance, is used to bridge insulating flanges and insulating fittings on pipes. Isolating spark gap 481 may be used, for example, to connect a lightning protection system with the earthing system of heavycurrent installations above 1 kv, with the auxiliary earthing points of residual current devices or with the measurement earthing points of laboratories. Further fields of application are the bridging of proximity points or making connections to pipework and tank installations which have cathodic corrosion protection. Both isolating spark gaps consist of two electrodes positioned at a defined distance in an insulated housing. In the event of lightning, the spark gap arcs through, and the two electrodes are temporarily electrically connected to each other. In version 480, electrodes of tungstencopper ensure an extremely high resistance to erosion, as well as low wear. This spark gap has (Ex) approval for use in explosion hazard areas. Block diagram of 480/481 F Mounting Isolating spark gaps 480 and 481 are installed with connecting lugs or connectors between the parts of the installation to be bridged. When installing the spark gaps, keep cable lengths short, since long cables increase the risk of unnecessary stress on the insulation due to inductive voltages. Test marks 102 Type 480 Please always state the order number when ordering.

Technical data Isolating spark gaps Parex isolating spark gap 480 Isolating spark gap 481 Explosion protection (Ex)s G 4 to VDE 0171 Test certificate PTB No. III B/E29 859 AC clamping voltage U p (50 Hz) 1kV(higher voltages are possible) 2.5 kv 100% lightning impulse U p 100 (1.2/50) clamping voltage Nominal discharge current I n (8/20) 100 ka 100 ka Impulse current test (10/350) with the lightning current parameters set out in IEC 613121 (02.95) Impulse current Charge Spec. energy I imp Q W/R 2kV 100 ka 50 As 2.5 MJ/Ω 5kV 50 ka 25 As 0.63 MJ/Ω Electrodes Tungstencopper Stainlesssteel Housing Epoxy moulding compound Epoxy moulding compound Connecting bolt Ø 10 mm; Stainlesssteel Connecting lug Brass, nickelplated, with screw, nut and spring washer Connecting lead 25 mm 2 Cu, NSLFF highlyflexible, with cable lug, screw, nut and spring washer Screws and nuts M10 Steel, hotdip galvanised Connecting lead length L L L 180 mm 250 mm 350 mm Subject to technical alterations Ordering data 40 480/180 480/250 480/350 Connecting lead length 180 mm Connecting lead length 250 mm Connecting lead length 350 mm 5240 03 4 5240 07 7 5240 06 9 Connecting lead length mm 136 82 180 250 350 481 Connection Ø 10 mm; stainlesssteel 5240 08 5 82 170 ø40 Please always state the order number when ordering. 103

Protection and isolating spark gaps Protection spark gap 482 The spark gap consists of two electrodes arranged at a defined distance from each other in a ceramic housing. Type 482 satisfies the requirements of degree of protection IP 54. F Block diagram of 482 Operation and fields of application OBO protection spark gap 482 is used to bridge proximity points between the service entry mast of a lowvoltage overhead line and components of the external lightning protection system in accordance with VDE 0100 and VDE 0185. Mounting OBO protection spark gap 482 is installed between parts of the installation to be bridged, by means of connectors. Technical data Protection spark gap 482 AC clamping voltage U AW (50 Hz) 10 kv Electrodes and connecting lugs Malleable cast iron, hotdip galvanised Housing Ceramic Connecting lugs Hole Ø 11 mm (M10) One connecting lug fitted with onepiece connector type 5001/DIN Clamping range 810 mm Screw and nut M10, steel, hotdip galvanised Serrated lock washer Stainlesssteel Clamp plate Zinc diecast, electrogalvanised IP Code IP 54 Subject to technical alterations Ordering data 482 Protection spark gap 5240 05 0 44 145 104 Please always state the order number when ordering.

Coupling of earthing installations FSV 20 The spark gap and highpower zinc oxide varistor in parallel provide potential equalisation, this prevents flashovers in the electronics. The FSV 20 has an extremely short response time and a low residual voltage. Block diagram of FSV 20 Operation and fields of application Surge device FSV 20 is used to provide coupling of separate earthing installations with respect to lightning current. In the event of lightning and EMP effects, it prevents dangerously high voltage differences arising between the function earth and the protective earth. Mounting The FSV 20 is connected between the function earth and the operational earth. It is connected directly to the relevant equipotential bonding bar. A choke connected in parallel in accordance with DIN 57160 VDE 0160 (not supplied) prevents highfrequency voltages reaching the function earth. Technical data FSV 20 Nominal discharge current I n 100 ka Impulse current test (10/350) with the lightning current parameters set out in IEC 613121 (02.95) Peak current I imp Charge Q Spec. energy W/R Discharge capacity to DIN 48 810 idt i 2 dt 100 ka 50 As 2.5 MJ/Ω 10 As 10 5 A 2 s Voltage protection level U p 1.5 kv Enclosure dimensions 196 x 144 x 71 Ordering data Subject to technical alterations FSV 20 Complete, in plastic enclosure 5099 80 3 144 71 196 232 Please always state the order number when ordering. 105