Electric Motor Actuator with a built in Microcomputer

Similar documents
Electric Motor Actuator with a built in Microcomputer

Compact Motorized Actuator

Compact Motorized Actuator

Compact Motorized Actuator

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features

MODEL: MRP6. Final Control Elements

OPERATION MANUAL. Linear Valve Actuator. Electrical Valve Actuator. September, nd

BFS / BFSM SERIES Installation & Maintenance Manual

Electric Actuator MULTI-TURN. ITM Series 0180 / 0450 / 0750 / 1800 / 3000

OPERATION MANUAL. Spring Return Actuator. Electrical Actuator. September, st

Electric Actuator. of innovated design. Introducing KIMAX CONTROLS INC. > Patented switch of manual & Motor operation. Clutchless manualoverride.

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors

Valves with a difference. Electrical Actuators DVC INTERNATIONAL

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

Economic Style Electric Actuator. ITQ Series

LA-5000 SERIES LINEAR VALVE ACTUATORS

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

ELECTRIC ACTUATOR. Quarter turn(rotary type) - ZGQ Series

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

Compact Electric Actuator. JFEW Series

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

WE Series FEATURES OPTION CONFIGURATION STANDARD CONFIGURATION

SERVO CONTROLLER. Sdtork Introduce Digital Servo Controller with several Features for all type of Valve Automation.

FEATURES OPTIONAL FEATURES

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

Generator Digital CONTROLLER Automatic synchronizer ASY-96/ ASY-96-A

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

AWWA. Electric Actuators WE Series Weatherproof CSA Approved TYPE 4 & 4X ,900 in-lbs. torque C CONTROLS

Power Supply Device (KLTE-430D) Installation & Operation Manual

WHEN A PLC IS TOO MUCH, AND SPACE FOR

MODEL: DAST-20. Telemetering System

n FRONT PANEL CONFIGURATIONS

Series E2000P. Electrical linear actuator. Features SPECIFICATION. Valve Division Wörth am Main. A. Hock MSR- und Electronic Service GmbH

Valve amplifier for proportional pressure valves

AMC mA Positioner

AMRI is ISO 9001 approved. Direct 1/4 turn electric actuators ACTELEC 3, 6, 12, 25, 50, 100 and 150 Output torques up to 1500 Nm

AD-8100 & AD-8200 Servo Amplifiers

Conductivity Transmitter N-LF V AC

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

E3 Adjustable Speed Drive Engineering Specification

Standard specifications MG15HL*E58

Series 70 24V and 120V Actuator 600 to 18,000 lb.-in.

Value Valves USA. Electric Actuator DOUBLE ACTING SPRING RETURN.

EA3012 TRANSCONDUCTANCE AMPLIFIER OPERATION MANUAL

Driver specifications Motor Specifications P.57

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

PART # mA Positioner

Explosion proof rotary actuator - On/Off or programmable regulating actuator

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

AE SERIES ACTUATORS 2016 EDITION. The Best Way To Automate Your Process. Modulating Capable. Extended Duty Cycle Models Fast Acting Models

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Spring Return DuraDrive Proportional Actuator

Electric thrust actuator. Electric thrust actuator ARI-PREMIO -Plus 2G. 2,2-5 kn. Electric thrust actuator. ARI-PREMIO -Plus 2G kn.

Worcester Controls PB SMART PRODUCTS

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

S11 Adjustable Speed Drive Engineering Specification

ELECTRONIC ROTARY GEAR MOTOR SERIES SED (AR2...SE )

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Sturdy explosion proof housing and smart performance with innovative and ever-strong coil drive even under harsh working environments

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

OPERATOR S INSTRUCTION MANUAL

General Specifications

USER MANUAL. EPP Intelligent Positioner Control Unit 1/22.

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

Please keep the following using conditions certainly

User's Manual: Series 250T AC Current Input (External Sensor) Two-Wire Transmitters

LA-T SERIES. Fast and reliable minute granular flaw detection in winding wires. Winding Wire Granular Flaw Detector PARTICULAR USE SENSORS

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

200 Watt Passive Shunt Module

RUNYI GROUP AJ FLOW TOTALIZER. Features

AC 01.2 HART Technical data Actuator controls

TMC3 SERVO CARD For WEM/XEM Series Actuators Installation & Maintenance Manual

AC 01.2 Modbus TCP/IP

S100A40AC SERIES BRUSHLESS SERVO AMPLIFIERS Model: S100A40AC

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

Electro Controls. Input-Output Modules WattsIndustries.co.uk

MODEL: DLS. Telemetering System

Multifunction Pulse-to-Pneumatic Converter

POWER ANALYZER OPERATION MANUAL. Model : DW-6090A

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Multi-turn Actuators ET RANGE

Milliamp Calibrator. Model 434. General description. Calibrate with laboratory accuracy. All 4 to 20 ma loop functions

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

Torque Sensor Accessories and Services

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Electronic Circuit Breaker ESS20-0..

Pure Sine Wave Inverter

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements

BS-3520 Digital Indicator

Compact Hydraulic System for Energy Savings and High Precision. POWER Meister

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Installation Tech Note Dallas, Texas

A cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications

INSTRUCTION MANUAL SMART POSITIONER ESL & ESR SERIES. ESL & ESR Series. Installation & Maintenance Manual

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

Transcription:

Electric Motor Actuator with a built in Microcomputer The New MICOM ELMY offers highly accurate controllability, and its various functions are easily set via communication with a personal computer. Controller features Flow characteristics can be set at work site with PC. High reliability Adjustable operating speed Multiple functions Compact New MICOM ELMY 2-0

Model Input signal Non-voltage contact input Output signal Non-voltage contact output Operation frequency rate Inching operation Positioning accuracy Resolution Flow characteristic variation Input signal mode Input signal failure mode Output signal mode Zero-span adjustment range Hysterisis adjustment range Operation speed control Protection function New MICOM ELMY II Specifications (Controller) New MICOM ELMY 2 4 to 20mA DC (input resistance 250 ohm) to 5V DC Openclose signal (a contact) 4 to 20mA DC (load resistance 300 ) Openclose contact signal (Capacity AC220V-0.3A, DC24V-A) Alarm output for hunching and thermal rising (Capacity AC220V-0.3A, DC24V-A) Power off output for excessive torque and thermal rising (Capacity AC220V-0.3A, DC24V-A) 50% ED or less 60 timesmin. or less % (For operation range of 90 degrees C, input signal amplitude of 6mA during linear operation.) 200 (For operation range of 90 degrees C, input signal amplitude of6ma during linear operation.) Cv linear settings (concentric and eccentric type are built into controller.) Disc angle linear settings Flow linear settings Direct, reverse Stop, open, close or optional position Direct, reverse -5 to 95 degrees C 0.5 to 4.0% at full span Range and operation speed can be adjusted. Limit switch at full open and close Mechanical stopper Resolution is set at /00 at the time of shipment. If any other resolution is required, please contact us. New MICOM ELMY II Specifications (Actuator) Type Type 0 Type Type 2 Type 2.5 Type 3 Output torquenm 70 98 96 333 98 Power sourcev AC00, 200, 220 50/60Hz Motor capacityw 8W 20W 30W 90W Operating range 0 to 90 degrees C Travel time5060hz 25/20 sec(0 to90 degrees C) 37/30 sec 55/50 sec sec (0 to 90 degrees C) (0 to 90 degrees C ) Insulation Class E Enclosure JIS C 0920 (IP 65), Class 5, dust and water-jet proof type Protect function Built in mechanical thermal protector stopper at full open and close side Conduit connections G/2PF/22 port Manual operation Detachable handle Declutchable handwheel Motor protection Built-in thermal protector Mechanical stopper End of travel positioning bolt Environmental temperature during operation 0 to 50 degrees C Environmental temperature during storage 30 to 80 degrees C Paint finish Epoxy-melanin baked with Munsell 2.5BG 6/2 Type 4 2000 25/05 sec (0 to 90 degrees C) New MICOM ELMY 2-02

TOMOE s software is compatible with Windows 98, 2000 and ME. Setting functions Various functions are easily set with a personal computer at the job site.factory setting is also available for specific customer requests. TOMOE s software and instruction manual are available for purchase. Variable flow characteristics Based on the actual flow rate at each opening degree, the relationship between valve movement and input signalcan be varied. Linear characteristics can be achieved as follows: Input signal: 20% Opening angle: 20% Actual flow rate: 50% After setting; Input signal: 20% Opening angle: 8% Actual flow rate: 20% Low rate data can be set at each 5% of opening. If flow rates at certain angles are not known, the program will automatically compensate for this to achieve the necessary data. Abnormal data logging The unit monitors actual operating conditions. Using this function, the operator can predict the cause of potential problems. The number of alarm calls due to thermal excesses in the actuator, the action of the torque limiter and the frequency of hunting during operation, are all recorded. Opening and closing stroke time can also be recorded. This enables the operator to plan maintenance routines and schedules. Make good use of this function to improve accuracy, valve sizing, and opening speed characteristics. New MICOM ELMY 2-03

Setting functions Speed control adjustment Stroke time can be varied with up to 5 intermediate stages. Stroke times for open to close and close to open can be set independently. Make good use of this function to improve the performance of pump discharge valves, quick opening characteristics, or to prevent water hammer. Note: After setting the speed, the electric motor motion should be as shown below. Motion Stop Time Display of setting data On screen display of setting data helps you to maintain accurate records and avoid setting errors. New MICOM ELMY 2-04

(Approx.) (Approx.) W (Approx.) W W New MICOM ELMY II Dimensions diagram Type 0 Type 2 A Type 2.5 P P A H3 H5 F K E 2G 2PF 2 H3 H5 K F F E K 2G 2PF 2 Type P A Type 3 Type 4 P A 2G 2PF 2 H3 H5 E F K (Approx.) 2G 2PF 2 H3 H5 New MICOM ELMY II Dimensions Motor type Type 0 Type Type 2 Type 2.5 Type 3 Type 4 Dimensionsmm H3 H5 K 85 9(93) 224(227) 224(227) 255(258) 255(258) ( ) shows non-iso top dimension The figure in ( ) is for other than 700G. 00 00 00 00 00 00 P 00 38 67 67 223 223 A 202 252 30 30 388 388 E 43 2 4 4 23 23 F 85 26 54 54 246 246 54 65 85 85 36 36 W 70 00 00 200 280 Approx. Mass (kg) 4.2 6.4.2 2.8 23.2 28.3 New MICOM ELMY 2-05

New MICOM ELMY II Wiring diagram New MICOM ELMY II Operation M Pot O.L.S S.L.S Option Space heater CTROL UNIT 2 3 4 5 6 7 8 9 0 2 3 4 5 6 Power supply AC00V/AC200V/AC220V 50Hz/60HzSingle phase Input signal D.C420mA Output signal D.C420mA Open Close Output dry contact AC220V0.3A Com AC25V0.5A DC24VA Open Close Com Auto Man Input dry contact CTROL ROOM OUTPUT SIGNAL ALARM SIGNAL INDICATOR MANUAL SETTING DATA Reset SW 7 8 9 20 Emergency stop Alarm Abnormal AlarmCom Earth Output dry contact AC220V0.3A AC25V0.5A DC24VA INPUT SIGNAL POWER Notes RS232C. Input and output signals are not isolated. 2. This diagram shows when valve disc is at intermediate position. 3. Control unit can be used for each voltage by switching jumper pin, but motor actuator can not. 4. Priority is given to contact input signal over analog input signal. 5. Output for emergency stop is generated when analog signal is cut during contact input operation. FLOW SENSOR FLUID Function Opening angle settings Input signal settings Output signal settings Signal failure mode Signal failure mode variation Flow characteristic variation Hysterisis variaton Hunting setting Hunting interval setting High frequency operation Abnormal output shaft operation Temperature monitoring Communication speed Logging data transmittal Display of setting data New MICOM ELMY II Control functions By software By DIP switch Signal linear, CV linear for concentric type of valve, and CV linear for eccentric type of valve Standard factory settings 0-90 or 0-70 degrees 4-20mA 4-20mA Emergency stop ma or less is 5 sec. No correction (linear signal) Input signal:.0% Angle signal: 0.5% Time for judgment: 80 sec Frequency of operation: 90 Operation angle range: 0 degrees Average angle: 5 degrees Signal hysteresis transition: 0.5% Interval limit hysteresis: 2% Automatically returns to hysteresis of time of shipping after 6 hrs. When signal hysteresis exceeds 2% for hunting interval 30 sec. 3 times Alarm: 50C 9600bps New MICOM ELMY II Initial setting mode at the time of shipment New MICOM ELMY II Operating system Input signal Output signal Flow rate adjustment Action at the time of abnormal situation Reverse action Reverse action No adjustment Emergency stop Usage environment RS232C interface (Connector: D-sub 9-pin) PC that can run Windows 2000, ME or 98 (Please consult us regarding Windows XP support.) Connect to PC with dedicated cable. Flow adjustment data Hold the data before reset Setting mode entry Operation mode New MICOM ELMY 2-06

New MICOM ELMY II Terminal board Notes. Input and output signals are not insulated. 2. Use FG terminal for earth. 3. Priority is given to contact input of terminal Nos. 4 to 6 over input signals of Nos. 3 and 4. Even terminal No. 3 is set to AUTO. Wiring diagram AC00/200/220V 50/60HZ INPUT 4-20mA OUTPUT 4-20mA OPEN Contact output CLOSE COM Terminal block screw size: M3 (with washer) 2 3 4 5 6 7 8 9 0 2 3 4 5 6 7 8 9 20 COM OPEN Contact input STOP CLOSE AUTO MAN STOP ALARM Contact output for alarm COM FG New MICOM ELMY II Contacts Terminals Contact output Contact input Terminal No. No. 7 (OPEN) No. 8 (CLOSE) No. 9 (COM) No. 7 (STOP) No. 8 (ALARM) No. 9 (COM) No. 3 (COM) No. 4 (OPEN) No. 5 (CLOSE) No. 6 (AUTO/MAN) Purpose Outputs at full open position Outputs at full closed position COM for No. 7 and 8 terminals Outputs when abnormally stopped * Outputs when alarm signal transmitted * 2 COM for No. 7 and 8 terminals COM for No. 4, 5 and 6 terminals Connect No. 3 when valve moves toward open direction Connect No. 3 when valve moves toward closed direction Switching of auto and manual operation. *: No. 7 works during signal failure, abnormal torque or temperature increase. *2: No. 8 works during hunting or abnormal temperature increase. Capacity AC220V-0.3A DC25V-0.5A DC24V-A Wiring diagram example for combination of auto and manual Operation by 4-20 ma signal. Closed during manual operation. COM OPEN CLOSE 3 4 5 6 AUTO MAN Operation by 4-20 ma signal. Open during manual operation. COM OPEN CLOSE 3 4 5 6 AUTO MAN New MICOM ELMY 2-07

New MICOM ELMY II Function and dip switch position Setting item SW SW2 Setting of dip switch SW3 SW4 SW5 SW6 SW7 SW8 Input signal Reverse action Direct action Output (feedback) signal Reverse action Direct action Opening degree adjustment None(Linear in accordance with signal) Cv linear for concentric valve Cv linear for eccentric valve For customer use Signal failure mode Stop Fully open Fully close Memorized opening degree *Initialization of setting data Hold Initialize Notes. Reset is necessary after switching. 2. An asterisk means all setting data (such as valve opening degree, input signal, zero span of output single, etc.) will be initialized. 3. Input signal: Reverse action: signal increase open Direct acton: signal increase close 4. Output signal: Reverse action: valve open signal increase Direct action: valve close signal increase 5. Shaded areas mean initial setting mode at the time of shipment. New MICOM ELMY 2-08

New MICOM ELMY II Parts list Types 0,,2 and 2.5 2 3 4 5 6 0 9 8 7 6 5 4 3 2 8 7 9 2 3 4 5 6 7 8 9 0 2 3 4 5 6 7 8 9 Terminal Limit switch cam Dog for open position Dog for closed position Reset switch Connector for potentiometer Dip switch LED Toggle switch Connector for motor Connector for motor capacitor Potentiometer Sub-indicator Connector for interface Limit switch (closed position) Limit switch (open position) Connector for heater Jumper pin Gland entry New MICOM ELMY II Parts list Types 3 and 4 4 2 3 0 7 8 9 5 6 2 4 5 3 20 2 6 7 23 22 8 9 2 3 4 5 6 7 8 9 0 2 3 4 5 6 7 8 9 20 2 22 23 Terminal Limit switch cam Dog for open position Dog for closed position Reset switch Connector for potentiometer Dip switch LED Toggle switch Connector for motor Connector for motor capacitor Potentiometer Sub-indicator Connector for interface Limit switch (open position) Limit switch (closed position) Connector for heater Jumper pin Gland entry Coil Capacitor Connector for open limit switch Connector for closed limit switch New MICOM ELMY 2-09

New MICOM ELMY II Recommended fuse and non-fuse breaker Type Power source and frequency Recommended capacity for fuse Recommended capacity for non-fuse breaker 0, 00V/0V 50Hz/60Hz 200V/220V 50Hz/60Hz 3A 2A 3A 2A 2, 2.5 00V/0V 50Hz/60Hz 200V/220V 50Hz/60Hz 5A 3A 5A 3A 3, 4 00V/0V 50Hz/60Hz 200V/220V 50Hz/60Hz 0A 7A 0A 7A New MICOM ELMY 2-0