IMPROVING EFFICIENCY OF ACTIVE POWER FILTER FOR RENEWABLE POWER GENERATION SYSTEMS BY USING PREDICTIVE CONTROL METHOD AND FUZZY LOGIC CONTROL METHOD

Similar documents
Improved Active Power Filter Performance for Renewable Power Generation Systems

Enhancement of Power Quality With Hybrid-Fuzzy Based Active Compensation Scheme for Grid Connected-Hybrid Power Generator

COPY RIGHT. N.N.V.L. SARASWATHI, MRS. G.RADHIKA Eluru Engineering College, Eluru; West Godavari (Dt); A.P, India.

Improvement of Power Quality with Hybrid Renewable Energy Sources Based Four Leg Inverter

Power Quality Improvement by Using Fuzzy Controlled Four Leg Inverter for Renewable Energy Sources

Control Strategy for Shunt Active Power Filters

Performance Analysis of Shunt Active Power Filter Using Fuzzy Controller

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

2020 P a g e. Figure.2: Line diagram of series active power filter.

WILEY CONTROL OF POWER INVERTERS IN RENEWABLE ENERGY AND SMART GRID INTEGRATION. Qing-Chang Zhong. Tomas Hornik IEEE PRESS

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

Power Quality improvement of a three phase four wire system using UPQC

Chapter 2 Shunt Active Power Filter

CONCLUSIONS AND SCOPE FOR FUTURE WORK

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

5DESIGN PARAMETERS OF SHUNT ACTIVE FILTER FOR HARMONICS CURRENT MITIGATION

Power Quality Improvement using Shunt Passive Filter

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

Power Quality Improvement in Distribution System Using D-STATCOM

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Modeling & Simulation of Micro Grid Distribution System to reduce Harmonics Using Active Power Filters and PI controllers

Unit Vector Theory based Unified Power Quality Conditioner for Power Quality Improvement

A Modified Control Method For A Dual Unified Power Quality Conditioner

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Application of Fuzzy Logic Controller in UPFC to Mitigate THD in Power System

Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

INVESTIGATION OF HARMONIC DETECTION TECHNIQUES FOR SHUNT ACTIVE POWER FILTER

Control of grid connected inverter system for sinusoidal current injection with improved performance

A Novel FPGA based PWM Active Power Filter for Harmonics Elimination in Power System

Improving the Power Quality by Four Leg VSI

A Voltage Controlled D-STATCOM for Power Quality Improvement with DVR

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

CHAPTER 7 CONCLUSIONS AND FUTURE SCOPE

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

SPWM Switching Strategy for Compensation of Unbalanced and Non Linear Load Effects in Three Phase Four Wire System Using D-Statcom

Power Quality Improvement of Unified Power Quality Conditioner Using Reference Signal Generation Method

Modeling of Single Stage Grid-Connected Buck-Boost Inverter for Domestic Applications Maruthi Banakar 1 Mrs. Ramya N 2

IJESR/Nov 2012/ Volume-2/Issue-11/Article No-21/ ISSN International Journal of Engineering & Science Research

Harmonics Reduction using 4-Leg Shunt Active Power Filters

A THREE PHASE SHUNT ACTIVE POWER FILTER FOR HARMONICS REDUCTION

Analysis of Hybrid Power Conditioner in Three-Phase Four-Wire Distribution Power Systems for Suppressing Harmonics and Neutral-Line Current

Grid Interconnection of Wind Energy System at Distribution Level Using Intelligence Controller

ISSN: Page 20. International Journal of Engineering Trends and Technology- Volume2Issue3-2011

TRANSFORMER LESS H6-BRIDGE CASCADED STATCOM WITH STAR CONFIGURATION FOR REAL AND REACTIVE POWER COMPENSATION

CHAPTER 4 DESIGN OF DC LINK VOLTAGE CONTROLLER FOR SHUNT ACTIVE POWER FILTER

PERFORMANCE OF DISTRIBUTION STATIC COMPENSATOR IN LOW VOLTAGE DISTRIBUTION SYSTEM

Power Control and Quality Management in DG Grid Interfaced Systems

Review on Shunt Active Power Filter for Three Phase Four Wire System

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

International Journal of Advance Research in Engineering, Science & Technology

Literature Review for Shunt Active Power Filters

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

Analysis, Modeling and Simulation of Dynamic Voltage Restorer (DVR)for Compensation of Voltage for sag-swell Disturbances

FUZZY BASED SMART LOAD PRIMARY FREQUENCY CONTROL CONTRIBUTION USING REACTIVE COMPENSATION

MITIGATION OF VOLTAGE SAG AND SWELL FOR POWER QUALITY IMPROVEMENT USING DISTRIBUTED POWER FLOW CONTROLLER

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

ISSN Vol.04,Issue.08, July-2016, Pages:

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

Modular Grid Connected Photovoltaic System with New Multilevel Inverter

HARMONIC ELIMINATION IN THREE PHASE SYSTEM BY MEANS OF A SHUNT ACTIVE FILTER

Implementation of D-STACTOM for Improvement of Power Quality in Radial Distribution System

A Voltage Controlled DSTATCOM using Hybrid Renewable Energy DC Link VSI for Power Quality Improvement

Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control

Load Compensation at a Reduced DC Link Voltage by Using DSTATCOM with Non-Stiff Source

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 01, 2016 ISSN (online):

Voltage Flicker Mitigation in Electric Arc Furnace using D-STATCOM

P. Sivakumar* 1 and V. Rajasekaran 2

HYSTERESIS CONTROL FOR CURRENT HARMONICS SUPPRESSION USING SHUNT ACTIVE FILTER. Rajesh Kr. Ahuja

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

Design of Hybrid Active Filter for Power Quality Improvement of Electrical Distribution System Using Fuzzy Logic Controller

CHAPTER 6 ANALYSIS OF THREE PHASE HYBRID SCHEME WITH VIENNA RECTIFIER USING PV ARRAY AND WIND DRIVEN INDUCTION GENERATORS

IMPORTANCE OF VSC IN HVDC

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

p. 1 p. 6 p. 22 p. 46 p. 58

Modified three phase Unified Power Quality Conditioner with capacitor midpoint topology

ISSN Vol.03,Issue.07, August-2015, Pages:

Cascaded Connection of Single-Phase & Three-Phase Multilevel Bridge Type Inverter

A Five Level Inverter for Grid Connected PV System Employing Fuzzy Controller

Protection from Voltage Sags and Swells by Using FACTS Controller

SHUNT ACTIVE POWER FILTER

DIGITAL SIMULATION OF MULTILEVEL INVERTER BASED STATCOM

Design of SVPWM Based Inverter for Mitigation of Harmonics in Power System

MODELING AND ANALYSIS OF IMPEDANCE NETWORK VOLTAGE SOURCE CONVERTER FED TO INDUSTRIAL DRIVES

Transcription:

IMPROVING EFFICIENCY OF ACTIVE POWER FILTER FOR RENEWABLE POWER GENERATION SYSTEMS BY USING PREDICTIVE CONTROL METHOD AND FUZZY LOGIC CONTROL METHOD T PRAHLADA 1, P SUJATHA 2, P BHARATH KUMAR 3 1PG Scholar, Dept. Of Electrical & Electronics Engineering, JNTUACEA, Anantapuramu, A.P., India 2 Professor, Dept. Of Electrical & Electronics Engineering, JNTUACEA, Anantapuramu, A.P., India 3 Lecturer, Dept. Of Electrical & Electronics Engineering, JNTUACEA, Anantapuramu, A.P., India ------------------------------------------------------------------------------***-------------------------------------------------------------------------------- Abstract- In this paper, an active power filter was implemented with a four-leg voltage-source inverter using a concept of predictive control along with fuzzy logic controller was presented. Here we are using fuzzy logic controller instead of using other controllers. The utilization of a four-leg voltage-source inverter allows the compensation of current harmonic components, as well as unbalanced current generated by single-phase nonlinear loads. A fuzzy controller is designed to mitigate the total harmonic distortion. Under steady state and transient operating conditions, the proposed active power filter compensation performance and the control strategy associated was demonstrated through simulation results. The simulation was done by using MATLAB/Simulink software. Index Terms Active power filter, current control, four-leg converters, predictive control, Fuzzy logic controller. I. INTRODUCTION social progress, it's necessary to fulfill the energy need by utilizing the renewable energy resources like wind, biomass, hydro, co-generation, etc. In sustainable energy system, energy conservation and also the use of renewable source are the key paradigm. The necessity to integrate the renewable energy like wind energy/pv into power system is to create it possible to reduce the environmental impact on typical plant. The integration of wind energy into existing power system presents technical challenges which need consideration of voltage regulation, stability, power quality issues. The power quality is a vital customer-focused measure and is greatly tormented by the operation of a distribution and transmission network. Increasing global energy consumption and noticeable environmental pollution are creating renewable energy more necessary. Today, a small percentage of total global energy comes from renewable sources, primarily hydro and wind power. Renewable generation affects power quality because of its nonlinearity, since solar generation plants and wind power generators should be connected to the grid through high-power static PWM converters [1]. The non-uniform nature of power generation directly affects voltage regulation and creates voltage distortion in power systems. This new situation in power distribution systems would require additional sophisticated compensation techniques. However, these dg units produce a wide range of voltages because of the fluctuation of energy resources and impose rigorous necessities for the inverter topologies and controls. To have sustainable growth and Fig. 1(a). Stand-alone hybrid power generation system with a shunt active power filter Renewable sources, like wind and sunlight, are generally used to generate electricity for residential users and little industries. Both kinds of power generation use ac/ac and dc/ac static PWM converters for voltage conversion and battery banks for long run energy storage. These converters perform maximum power point tracking to extract the maximum energy attainable from wind and sun. Fig. 1(a) shows the configuration of a typical power 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 334

distribution system with renewable power generation. It consists of various kinds of power generation units and differing kinds of loads. Although active power filters enforced with three-phase four-leg voltage-source inverters (4L-VSI) have already been presented within the technical literature [2] [6]. An correct model obtained mistreatment predictive controllers improves the performance of the active power filter, particularly throughout transient operating conditions, as a result of it will quickly follow the current-reference signal whereas maintaining a constant dc-voltage. However recently there are several researchers reported with success adopted fuzzy logic Controller (FLC) to become one amongst intelligent controllers to their appliances. With reference to their successful methodology implementation, this type of methodology enforced in this paper is using fuzzy logic controller with feedback by introduction of voltage severally. The introduction of modification in voltage within the circuit is going to be fed to fuzzy controller to give acceptable measure on steady state signal. The fuzzy logic controller is intelligent controller for this proposes. This paper presents the mathematical model of the 4L-VSI and therefore the principles of operation of the projected predictive control scheme, as well as the design procedure. Finally, the proposed active power filter and therefore the effectiveness of the associated control scheme compensation, power quality improvement is simulated using Matlab/ Simulink. PI CONTROLLER A proportional integral controller (PI controller) could be a control loop feedback mechanism (controller) normally employed in industrial control systems. A PI controller continuously calculates an error value e(t), e(t) because the difference between a desired set point and a measured method variable and applies a correction supported proportional and integral terms (sometimes denoted P and i respectively) that provide their name to the controller kind. A PI controller continuously calculates an error value e(t), e(t) because the difference between a desired set point and a measured method variable and applies a correction supported proportional, integral, and derivative terms. The controller makes an attempt to reduce the error over time by adjustment of a control variable u(t), like the position of a control valve, a damper, or the ability equipped to a element, to a new value determined by a weighted sum: U(t)=k pe(t) + k i The proportional term produces an output value that's proportional to the present error value. The proportional response will be adjusted by multiplying the error by a constant Kp, known as the proportional gain constant. Fig. 1(b). PI controller The contribution from the integral term is proportional to each the magnitude of the error and therefore the duration of the error. The integral during a PID controller is that the add of the instantaneous error over time and provides the accumulated offset that ought to are corrected previously. The accumulated error is then multiplied by the integral gain (Ki) and added to the controller output. Here, we are using PI controller in current reference generator, when filtering the error voltage by using low pass filter we are applying it to the PI controller it provides the ability reference signal ie. II.MODELING OF FOUR-LEG CONVERTER The consumption of electrical energy is random and unpredictable behavior, and thus, it ought to be single- or three-phase, balanced or unbalanced, and linear or nonlinear. At the point of common coupling, an active power filter is connected in parallel to compensate current harmonics, current unbalance, and reactive power. It's composed by an electrolytic capacitor, a fourleg PWM converter, and a first-order output ripple filter, as shown in Fig. 2. This circuit considers the power system equivalent impedance, the converter output ripple filter impedance, and the load impedance. The Fig. 3 shows the four-leg PWM converter topology. This converter topology is analogous to the traditional three-phase converter with the fourth leg connected to the neutral bus of the system. The fourth leg will increase switching states from 8 to 16, improving control flexibility and output voltage quality, and is appropriate for current unbalanced compensation. 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 335

III. CONTROL STRATEGY DIGITAL PREDICTIVE CURRENT CONTROL The block diagram of the proposed digital predictive current control theme is shown in Fig. 3. This control theme is essentially an optimization algorithm and, therefore, it's to be enforced in a microprocessor. Consequently, the analysis should be developed using separate mathematics so as to consider extra restrictions like time delays and approximations. Fig. 2. Three-phase equivalent circuit of the proposed shunt active power filter Fig. 4. Proposed predictive digital current control block diagram Fig. 3. Two-level four-leg PWM-VSI topology The voltage in any leg x of the converter, measured from the neutral point (n), can be obtained in terms of the switching states, as follows: The mathematical model of the filter derived from the equivalent circuit shown in Fig. 2 is Where and are the 4L-VSI output parameters expressed as Thevenin impedances at the converter output terminals. Therefore, the Thevenin equivalent impedance is determined by a series combination of ripple filter impedance and a parallel arrangement between the system equivalent impedance and the load impedance For this model, it is assumed that, that the system s equivalent impedance resistive part is neglected, and that the series reactance is in the range of 3 7% p.u., which is an acceptable approximation of the real system. Finally, in (2) and. The main characteristic of predictive control is that the use of the system model to predict the future behavior of the variables to be controlled. The predictive control algorithm is simple to implement and to know, and it are often enforced with 3 main blocks, as shown in Fig. 4. (A) Current Reference Generator: This unit is meant to get the desired current reference that's used to compensate the undesirable load current parts. During this case, the system voltages, the load currents, and also the dc-voltage converter are measured, whereas the neutral output current and neutral load current are generated directly from these signals. (B) Prediction Model: The converter model is employed to predict the output converter current. Since the controller operates in separate time, each the controller and also the system model should be represented in a very discrete time domain. this implies that for a given sampling time, knowing the converter switching states and control variables at instant k, it is possible to predict the next states at any instant [k+1]. Owing to the first-order nature of the state equations that describe the model in (1) (2), a sufficiently correct first-order approximation of the derivative is taken into account during this paper [ ] [ ] 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 336

(C) Cost Function Optimization: In order to select the optimal switching state that must be applied to the power converter, the 16 predicted values obtained for [k + 1] are compared with the reference using a cost function g, as follows: [ ] ( [ ] [ ]) ( [ ] [ ]) ( [ ] [ ]) ( [ ] [ ]) The output current is capable the reference when g = 0. Therefore, the optimization goal of the cost operate is to attain a g value near zero. Throughout every sampling state, the switching state that generates the minimum value of g is chosen from the 16 attainable operate values. The algorithm selects the switching state that produces this nominal value and applies it to the converter throughout the k + 1 state. CURRENT REFERENCE GENERATION A dq-based current reference generator theme is employed to get the active power filter current reference signals. This theme presents a quick and correct signal tracking capability. This characteristic avoids voltage fluctuations that deteriorate the present reference signal moving compensation performance. the present reference signals are obtained from the corresponding load currents as shown in Fig. 5. Where the value of includes the maximum compensable harmonic current, defined as double the sampling frequency. The frequency of the maximum current harmonic component that can be compensated is equal to one half of the converter switching frequency. The dq-based theme operates during a rotating reference frame; so, the measured currents should be increased by the sin(wt) and cos(wt) signals. By using dqtransformation, the d current part is synchronized with the corresponding phase-to-neutral system voltage, and therefore the q current part is phase-shifted by 90. The sin(wt) and cos(wt) synchronized reference signals are obtained from a synchronous reference frame (SRF) PLL. The SRF-PLL generates a pure sinusoidal waveform even once the system voltage is severely distorted. Following errors are eliminated, since SRF-PLLs are designed to avoid phase voltage unbalancing, harmonics (i.e., less than 5% and 3% in fifth and seventh, respectively), and offset caused by the nonlinear load conditions and measurement errors. IV. SIMULATION RESULTS A simulation model for the three-phase four-leg PWM converter with the parameters shown in Table-2 has been developed exploitation MATLAB-Simulink. the target is to verify the present harmonic compensation effectiveness of the projected control theme under completely different operational conditions. A six-pulse rectifier was used as a nonlinear load. The projected predictive control formula was programmed exploitation an S-function block that permits simulation of a separate model that may be simply implemented during a real-time interface (RTI) on the dspace DS1103 R&D control board. Simulations were performed considering a 20 [μs] of sample time. TABLE 2: SPECIFICATION PARAMETER Fig. 5.dq-based current reference generator block diagram This module calculates the reference signal currents needed by the converter to compensate reactive power, current harmonic and current imbalance. The displacement power factor ( ) and the maximum total harmonic distortion of the load ( ) defines the relationships between the apparent power needed by the active power filter, with regard to the load, as shown Variable Description value v s Source voltage 55v F System frequency 50Hz v dc dc voltage 162v L f Filter inductor 5 mh C dc dc capacitor 2200µF R f Internal resistance with R f 0.6Ω T s Sampling time 20µs T e Execution time 16µs Note:v base=55v and S base=1kva 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 337

In the simulated results shown in Fig. 14, the active filter starts to compensate at t = t1. At now, the active power filter injects an output current to compensate current harmonic parts, current unbalanced, and neutral current at the same time. Throughout compensation, the system currents authority show sinusoidal waveform, with low total harmonic distortion (THD = 3.93%). At t = t2, a three-phase balanced load step change is generated from 0.6 to 1.0 p.u. The compensated system currents stay sinusoidal despite the change within the load current magnitude. Finally, at t = t3, a singlephase load step change is introduced in phase u from 1.0 to 1.3 p.u., that is admire an 11 November current imbalance. of course on the load aspect, a neutral current flows through the neutral conductor, however on the supply aspect, no neutral current is determined. Simulated results show that the projected control theme effectively eliminates unbalanced currents. Additionally, Fig. 8 shows that the dc-voltage remains stable throughout the entire active power filter operation. 4.3 CONTROL CIRCUITS 4.2 MATLAB MODEL Fig. 10.Matlab model for control circuit algorithm 4.3.1. With PI controller Fig. 8.Matlab model of proposed system Fig. 9. Scopes for output waveforms Fig. 11. Control circuit with PI controller 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 338

4.3.2. With fuzzy logic controller Fig. 14(b).Simulated waveforms of the proposed control scheme. (i) DC voltage converter. Fig. 12. Control circuit with fuzzy logic controller 4.4 MATLAB RESULTS 4.4.1. With PI controller Fig. 13. Fuzzy logic controller Fig. 14(c).Simulated waveforms of the proposed control scheme. (i) Load neutral current. (ii) System neutral current. (iii) System currents. 4.4.2. With fuzzy logic controller Fig. 14(a).Simulated waveforms of the proposed control scheme. (i) Phase to neutral source voltage. (ii) Load Current. (iii) Active power filter output current. Fig. 15(a).Simulated waveforms of the proposed control scheme. (i) Phase to neutral source voltage. (ii) Load Current. (iii) Active power filter output current. 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 339

With Fuzzy Logic Control: Fig. 15(b).Simulated waveforms of the proposed control scheme. (i) DC voltage converter. Fig. 15(c).Simulated waveforms of the proposed control scheme. (i) Load neutral current. (ii) System neutral current. (iii) System currents. With PI controller: V. THD Results Comparison: Threshold Harmonic Distortion (THD) value of the System current (i s) decreased to 3.01% by using fuzzy logic compared to 3.89% by using PI controller. VI.CONCLUSION Dynamic current harmonics Improvement and a reactive power compensation theme for power distribution systems with generation from renewable sources have been planned to boost this quality of the distribution system. Advantages of the planned theme are associated with its simplicity, modeling, and implementation. The employment of a predictive control algorithm for the converter current loop tried to be an efficient resolution for active power filter applications, improving current following capability, and transient response. Simulated results have tried that the planned predictive management algorithm is also a good varied to classical linear management ways. The predictive current control algorithm is also a stable and robust answer. Total harmonic distortion was reduced by using fuzzy controller in comparison to PI controller. Simulated results have shown the compensation effectiveness of the proposed active power filter. The simulation was done by using Matlab/Simulink software. REFERENCES [1] J. Rocabert, A. Luna, F. Blaabjerg, and P. Rodriguez, Control of power converters in AC microgrids, IEEE Trans. Power Electron., vol. 27, no. 11, pp. 4734 4749, Nov. 2012. [2] M. Aredes, J. Hafner, and K. Heumann, Three-phase fourwire shunt active filter control strategies, IEEE Trans. Power Electron., vol. 12, no. 2, pp. 311 318, Mar. 1997. [3] S. Naidu and D. Fernandes, Dynamic voltage restorer based on a fourleg voltage source converter, Gener.Transm.Distrib., IET, vol. 3, no. 5, pp. 437 447, May 2009. [4] N. Prabhakar and M. Mishra, Dynamic hysteresis current control to minimize switching for three-phase four-leg VSI topology to compensate nonlinear load, IEEE Trans. Power Electron., vol. 25, no. 8, pp. 1935 1942, Aug. 2010. 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 340