Operating Manual. GV210 Encoder distributor, cross switcher and splitter for incremental encoder signals. Product Features:

Similar documents
Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs

PU202 Level converter & encoder signal generator without potential separation

SI251 SinCos interpolator for encoders and measuring systems with SinCos output

ZU 252 Incremental counter module with analog output and serial interface

IT 251. Level Converter and Programmable Impulse Divider. Operating Instructions. control motion interface

IF30. User's manual. Description. Table of contents IF30

PU202. Encoder Signal Generator and Level Converter. Operating Instructions. control motion interface

Operating Manual FU 252. Signal converter for frequency -analog / serial. Your partner for standard and special designs - precise, reliable and fast -

IP 251 Universal Signal Converter SSI parallel RS232 parallel SSI RS232

External brake resistor AX2090-BW5x

PRODIS. PD-INC Digital Process Meter for sensors with incremental output. Digital Process Meters. Datasheet

Power supply CP-D 24/4.2 Primary switch mode power supply

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Power supply CP-D 12/2.1

Strain Gauge Measuring Amplifier BA 662

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

English. Operating manual. Temperature measuring transducer MU125. Save for later reference. Company / brands of GHM

Industrial motor controller for brushed DC motors 24 VDC

Magnetic Inductive Flow Sensor induq

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Industrial motor controller for brushed DC motors 24 VDC

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

RMO500 M I C R O O H M M E T E R

Power supply CP-D 24/1.3

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

ITP14. Universal process indicator. User guide

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Operating Instruction

SCA-SS (70V, 10A)

Radio System Strobe Wizard Plus Freemask

Power supply CP-E 24/2.5

VARAN Stepper Module VST 012

Heavy Duty Push-pull / RS422 / speed switch. RoHS 2/22. Magnetic field proof. XXXX e

Industrial motor controller for brushed DC motors 12 VDC

Power supply CP-E 24/20.0

W(G)S3.1 Position Sensor with Analog or A/D converted synchronous serial output

DX020. Tachometer and Frequency Counter. Operating Instructions. control motion interface

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

PRetrans Table of contents

PMIS2 POSIMAG Magnetoresistive Position Sensor with Incremental Output

For detailed specifications and ordering info go to

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

Absolute Encoders Multiturn

BDD-UM 3023 Digital Display

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02

Circuit Breaker Finder

MINI MCR-SL-UI-I-LP-NC

XPR522 XPR540. XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Manual SCA-SS V /02 page 1

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

Mini Encoder High Resolution

PHV RO High Voltage Passive Probe. Instruction Manual

Magnetic, Incremental - Length Measuring System. Only functional with an ELGO MB R magnetic tape!

XXXX e. X d.. X X X a

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

Power supply CP-E 24/0.75

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Operating instructions Fail-safe delay timer AZS About this document. Content

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

TA MHz oscilloscope probe TA MHz oscilloscope probe

Pulse Scaler for DIN Rail Attachment

User s Guide. Model MA A AC Mini Clamp-on Meter

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

Power supply CP-T 24/20.0 Primary switch mode power supply

Inductive sensor slot-type SI2-K08-AP7

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders 18 bit ST / 12 bit MT

Fieldbus Independent I/O Modules Incremental Encoder Interface Manual

maxon document number:

Incremental encoders Blind or through hollow shaft ø12 mm pulses per revolution

AC MASTER Switch mode sine wave inverter

DSB810A Digital DC Servo Driver Manual V1.0

Absolute Encoders - Singleturn

Radio Control Installation and Operating Instructions System 4

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

TK 100 Probe Calibrator. Instruction Manual

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Phase-sequence Phase-loss Relay

FU 252 Signal Converter Frequency-to-Analogue and Frequency-to-Serial

MINI-PS AC/24DC/1.3

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

POSIROT. PMIS4, PMIR5 Magnetic incremental encoder. Magnetic wheels for rotative applications PMIS4, PMIR5

XXXX e. X d.. X X X a

Power supply CP-T 48/20.0 Primary switch mode power supply

Phone: Fax: Web: -

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

Preset counters, electronic

Grid Radar Installation Manual

RoHS. High shaft load capacity. Shock / vibration resistant

Cable Identifying Generator LCI TX / LCI TX-440

Transcription:

Operating Manual www.genesisutomationonline.com GV20 Encoder distributor, cross switcher and splitter for incremental encoder signals Product Features: Universal encoder interface, applicable as level converter, encoder splitter and cross switch Two encoder inputs (, /,, /,, /), adjustable either to HTL, TTL or RS422 level Suitable for quadrature, symmetrical, asymmetrical as well as single channel signals Two signal outputs (, /,, /,, /), adjustable either to HTL, TTL or RS422 level Contactless and bounce-free switch-over between the encoder channels, by remote control signals uxiliary output 5 VDC for encoder supply High frequency range up to MHz 3046 Home Road. Powell, OH 43065 P: (740) 97-578 F: (740) 97-579 www.genesisutomationonline.com Sales@GenesisutomationOnline.com

Version: Description: GV200b/ Feb.05 /af/hk Original version released GV200c/ Jul. 05 /hk Terminal assignments and coding (X X5) GV200d/ ug.05 /hk Clarification RS422 /differential and HTL /single-ended operation GV200e/ Jul.07 /hk Corrections TTL-single-ended, outlines and dimensions GV2002a/ Feb 08 /hk New version, MHz, DIL switch for TTL single-ended GV2002b/ Dec /mb Temperature range GV2002c/ pr 2 /pp Chapter 6 : Corrected Dimension Drawing (DIL) GV2002d/ Sep 3 /af/nw Correction Technical Specifications Gv2002e/ Feb.5/ag Some modifications and modulations. Safety Instructions & Technical Specifications renewed. Gv20_02e_oi/Jan-6/ag Extended temperature range modified. Design updated and Legal notices added. Legal notices: ll contents included in this manual are protected by the terms of use and copyrights of motrona GmbH. ny reproduction, modification, usage or publication in other electronic and printed media as well as in the internet requires prior written authorization by motrona GmbH. Gv20_02f_oi_e.doc / 0-6 Page 2 / 3

Table of Contents. Safety Instructions and Responsibility... 4. General Safety Instructions... 4.2 Use according to the intended purpose... 4.3 Installation... 5.4 Cleaning, Maintenance and Service Notes... 5 2. pplications... 6 2.. Dual level converter... 6 2.2. Encoder splitter (dual output)... 6 2.3. Encoder signal switcher... 7 3. Connection Diagram... 8 3.. Power supply... 8 3.2. Control inputs... 8 3.3. Incremental inputs... 8 3.4. symmetric TTL Inputs... 9 3.5. Incremental Outputs... 9 4. The Front LEDs... 0 5. Switch Settings... 6. Dimensions... 2 7. Technical Specifications... 3 Gv20_02f_oi_e.doc / 0-6 Page 3 / 3

. Safety Instructions and Responsibility. General Safety Instructions This operation manual is a significant component of the unit and includes important rules and hints about the installation, function and usage. Non-observance can result in damage and/or impairment of the functions to the unit or the machine or even in injury to persons using the equipment! Please read the following instructions carefully before operating the device and observe all safety and warning instructions! Keep the manual for later use. pertinent qualification of the respective staff is a fundamental requirement in order to use these manual. The unit must be installed, connected and put into operation by a qualified electrician. Liability exclusion: The manufacturer is not liable for personal injury and/or damage to property and for consequential damage, due to incorrect handling, installation and operation. Further claims, due to errors in the operation manual as well as misinterpretations are excluded from liability. In addition the manufacturer reserve the right to modify the hardware, software or operation manual at any time and without prior notice. Therefore, there might be minor differences between the unit and the descriptions in operation manual. The raiser respectively positioner is exclusively responsible for the safety of the system and equipment where the unit will be integrated. During installation or maintenance all general and also all country- and application-specific safety rules and standards must be observed. If the device is used in processes, where a failure or faulty operation could damage the system or injure persons, appropriate precautions to avoid such consequences must be taken..2 Use according to the intended purpose The unit is intended exclusively for use in industrial machines, constructions and systems. Nonconforming usage does not correspond to the provisions and lies within the sole responsibility of the user. The manufacturer is not liable for damages which has arisen through unsuitable and improper use. Please note that device may only be installed in proper form and used in a technically perfect condition - in accordance to the Technical Specifications (see chapter 7). The device is not suitable for operation in explosion-proof areas or areas which are excluded by the EN 600- standard. Gv20_02f_oi_e.doc / 0-6 Page 4 / 3

.3 Installation The device is only allowed to be installed and operated within the permissible temperature range. Please ensure an adequate ventilation and avoid all direct contact between the device and hot or aggressive gases and liquids. efore installation or maintenance, the unit must be disconnected from all voltage-sources. Further it must be ensured that no danger can arise by touching the disconnected voltagesources. Devices which are supplied by C-voltages, must be connected exclusively by switches, respectively circuit-breakers with the low voltage network. The switch or circuit-breaker must be placed as near as possible to the device and further indicated as separator. Incoming as well as outgoing wires and wires for extra low voltages (ELV) must be separated from dangerous electrical cables (SELV circuits) by using a double resp. increased isolation. ll selected wires and isolations must be conform to the provided voltage- and temperatureranges. Further all country- and application-specific standards, which are relevant for structure, form and quality of the wires, must be ensured. Indications about the permissible wire crosssections for wiring are described in the Technical Specifications (see chapter 7). efore first start-up it must be ensured that all connections and wires are firmly seated and secured in the screw terminals. ll (inclusively unused) terminals must be fastened by turning the relevant screws clockwise up to the stop. Overvoltages at the connections must be limited to values in accordance to the overvoltage category II. For placement, wiring, environmental conditions as well as shielding and earthing/grounding of the supply lines the general standards of industrial automation industry and the specific shielding instructions of the manufacturer are valid. Please find all respective hints and rules on www.motrona.com/download.html --> [General EMC Rules for Wiring, Screening and Earthing]..4 Cleaning, Maintenance and Service Notes To clean the front of the unit please use only a slightly damp (not wet!), soft cloth. For the rear no cleaning is necessary. For an unscheduled, individual cleaning of the rear the maintenance staff or assembler is self-responsible. During normal operation no maintenance is necessary. In case of unexpected problems, failures or malfunctions the device must be shipped for back to the manufacturer for checking, adjustment and reparation (if necessary). Unauthorized opening and repairing can have negative effects or failures to the protection-measures of the unit.. Gv20_02f_oi_e.doc / 0-6 Page 5 / 3

2. pplications 2.. Dual level converter RS422 or HTL 0-30V, /,, /,, / In Control = LOW Out HTL 0-30V or RS422, /,, /,, / In2 Out2, /,, /,, /, /,, /,, / RS422 or Control 2 HTL 0-30V HTL 0-30V = HIGH or RS422 oth inputs can be individually set to either symmetric (differential) format using, /,, /,, / channels, or to asymmetric (single-ended) format using,, channels only. cceptable input levels are RS422, TTL and HTL 0 30 V. The output format can again be selected individually for each output. The outputs provide always all signals including the inverted channels, even when no inverted signals are applied to the input. With Control input = LOW (or unconnected) and Control input 2 = HIGH the signal ways are as shown in the drawing above, featuring two independent level converters. 2.2. Encoder splitter (dual output) RS422 or HTL 0-30V Control = LOW (n.c.) HTL 0-30V or RS422, /,, /,, /, /,, /,, / In Out N.C. In2 Out2 Control 2 = LOW (n.c.), /,, /,, / HTL 0-30V or RS422 Input is used as encoder input, and Input 2 remains unconnected. The input can be set to either symmetric (differential) format using, /,, /,, / channels, or to asymmetric (single-ended) format using,, channels only. cceptable input levels are RS422, TTL and HTL 0 30 V. The output standard can again be selected individually for each output. The outputs provide always all signals including the inverted channels, even when no inverted signals are applied to the input. Control and Control2 remain unconnected with this application. Gv20_02f_oi_e.doc / 0-6 Page 6 / 3

2.3. Encoder signal switcher oth inputs can be individually set to either symmetric (differential) format using, /,, /,, / channels, or to asymmetric (single-ended) format using,, channels only. cceptable input levels are RS422, TTL and HTL 0 30 V. The output standard can again be selected individually for each output. The outputs provide always all signals including the inverted channels, even when no inverted signals are applied to the input. Inputs Control and Control2 select the signal ways: LOW: The corresponding output is connected to input HIGH: The corresponding output is connected to input 2 Gv20_02f_oi_e.doc / 0-6 Page 7 / 3

3. Connection Diagram Output GND Input 24V 5.2V GND Control Control 2 GND 24V GND 3 2 2 2 3 4 5 6 7 8 DIL Switch X6 X LED 8 7 6 5 4 3 2 Terminal strip 8-pos. X5 Power supply 9 8 7 6 5 4 3 2 Terminal strip 9-pos. X4 Connectors are mechanically coded and therefore not interchangeable X2 Terminal strip 8-pos. 2 3 4 5 6 7 8 X3 Terminal strip 9-pos. 2 3 4 5 6 7 8 9 Output 2 GND 24V 5.2V Input 2 GND 3.. Power supply The unit requires a 2 30 VDC power supply via the 2-position power terminal on the front side (terminal = +, terminal 2 = GND). The current consumption is about 50 m (in case of unloaded aux. voltages and outputs). 3.2. Control inputs The control inputs are accessible via the 3-position terminal strip on the front. They are in LOW state when unconnected. To switch the inputs to HIGH state, a signal from +0 to +30 V must be applied to the corresponding terminal. 3.3. Incremental inputs The input lines can be configured for different requirements by DIL switch setting. The following input formats can be used: Single-ended signals (asymmetric), channels, and only without inverted inputs (Level is HTL 0 30 V in general, exceptionally also TTL, see chapter 3.4)., and can also be single-signals, e. g. from light barriers (for example only channel is connected). Differential signals (symmetric), channels, /,, /,, / (levels either according to RS422 standard or TTL or HTL 0 30 V) Gv20_02f_oi_e.doc / 0-6 Page 8 / 3

, and may at any time also be independent single signals, e.g. from proximities, photocells etc. Since the level of every channel is selected individually (see DIL-switch), it is possible to use different levels on the inputs. Consequently it is e.g. possible to take the position information from the, /, and / channels of a RS422 encoder, but to add the corresponding index pulse as a HTL signal from a remote photocell With HTL signals, the switching threshold lies between 6.5 and 8 V. The input uses an internal pull-down resistor of 5kOhms. Every of the two input terminals provides two auxiliary voltage outputs for easy encoder supply: +5.2 V / 25 m and +24 V* / 25 m *) Output = power supply voltage minus 2 V 3.4. symmetric TTL Inputs Only when exceptionally asymmetric TTL input signals must be processed (i.e. TTL signals without inverted signal), a 2-position DIL switch located behind the front plate must be set. This hidden switch becomes accessible by slightly lifting up the front foil at the lower end (e.g. by means of a small screw driver) Switch position is responsible for all channels of Input Switch position 2 is responsible for all channels of Input 2 OFF = symmetric operation with HTL levels (0 30 V) ON = symmetric operation with TTL levels Ex-factory both switches are OFF, i.e. any single-ended operation requires HTL levels (this is the normal case) symmetric TTL levels are most sensitive to noise and interference, therefore not suitable for cable transmission in an industrial environment! For all general applications please do not touch the DIL switch hidden behind the front plate! 3.5. Incremental Outputs The outputs provide push-pull characteristics. When set to TTL/RS422 level, the corresponding output swing is always 5 V. When set to HTL, the output swing depends on the power supply input (2 30 V). ll outputs are short-circuit-proof. t any time the signal and the appropriate inverted signal are both available at the output, even when no inverted signal is applied to the input. Gv20_02f_oi_e.doc / 0-6 Page 9 / 3

4. The Front LEDs The green LED is lit as soon as a power supply voltage is applied to the unit. The yellow LED indicates the state of the Control inputs and the basic function of the unit: Yellow LED off: Control and Control2 are either both LOW or both HIGH at the same time. In this case the unit operates as a splitter (both outputs are connected to the same input) Yellow LED on: Control and Control2 have different states. In this case the unit operates as a dual level converter or as a switcher (the outputs are connected to different inputs) Gv20_02f_oi_e.doc / 0-6 Page 0 / 3

5. Switch Settings The DIL switch sets level and standard of inputs and outputs: 0=OFF =ON 8 7 6 5 4 3 2 DIL switch settings 0 Output : TTL / RS422 Output : HTL 0 Output 2: TTL / RS422 Output 2: HTL The output levels are 5 V with TTL setting and correspond to the power supply voltage with HTL setting 0 () () 0 () () 0 () () 0 () () 0 () () 0 () () Input : differential (, /,, /,, /) Input : single-ended (,,) with HTL level *) Input 2: differential (, /,, /,, /) Input 2: single-ended (,,) with HTL level *) oth, input and inverted input must be used. Levels from 2 up to 30 V are acceptable. Inverted inputs remain open, level must be HTL 0 30 V oth, input and inverted input must be used. Levels from 2 to 30 V are acceptable. Inverted inputs remain open, level must be HTL 0 30 V *) This setting can also be used with asymmetric (single-ended) TTL levels. See 3.4 Please set unused input lines to single-ended HTL at any time! It is not mandatory to use the same level for all channels of an input. The indications (), (), () show which switch position is responsible for which channel. When e.g. positions 3 and 4 are set to 0 and position 5 is set to, Input would accept, /,, / at RS422 standard, and the index as a HTL single-ended signal. Consequently it is possible to e.g. generate an Index from a remote photocell, whereas the impulses come from the RS422 encoder simulation of a drive system. Gv20_02f_oi_e.doc / 0-6 Page / 3

ON 6. Dimensions 22.5 (0.886 ) 02 (4.06 ) 9 (3.583 ) 02 (4.06 ) 82.5 (3.248 ) Front view Side view Top view Gv20_02f_oi_e.doc / 0-6 Page 2 / 3

7. Technical Specifications Power supply: Input voltage: Protection circuit: Ripple: Consumption: 2 30 VDC reverse polarity protection 0 % at 24 VDC approx. 50 m (unloaded) Connections: Connector type: screw terminals,.5 mm² / WG 6 Encoder supply Output voltages: 5.2 VDC und 0 28 VDC (app. 2 VDC lower than input voltage) Output current: max. 25 m Incremental inputs: Control inputs: Incremental outputs: Protection: Number of inputs: Signal levels: Channels: Frequency: Internal resistance: Number of inputs: pplication: Levels: Number of outputs: Output level: Channels: Output current: Output circuit: Signal propagation delay: Protection: Material: Mounting: Dimensions: short-circuit proof 2 adjustable to TTL / RS422 (differential signal > V) or HTL (0 30 V) symmetrical:, /,, /,, / asymmetrical:,, symmetrical: max. MHz asymmetrical: max. 250 khz Ri 4.7 kohm 2 contactless and bounce-free signal switchover HTL, PNP (0 30 V) 2 adjustable to TTL / RS422 or HTL (2 30 V, power supply voltage), /,, /,, / RS422/TTL: 50 m, HTL: max. 30 m (per output) push-pull approx. 600 ns short-circuit proof Housing: plastic 35 mm top hat rail (according to EN 6075) 22.5 x 02 x 02 mm (w x h x d) resp. 0.885 x 4.06 x 4.06 inch Protection class: IP20 Weight: approx. 00 g Temperature range: Operation: -20 - +60 C / -04 - +40 F (not condensing) Storage: -30 - +75 C / -22 - +67 F (not condensing) Failure rate: MTF in years: 46.4 a (long-term usage at 60 C / 40 F ) Conformity & standards: EMC 2004/08/EC: Guideline 20/65/EU: EN 6000-6-2, EN 6000-6-3, EN 6000-6-4 RoHs-conform Gv20_02f_oi_e.doc / 0-6 Page 3 / 3 3046 Home Road. Powell, OH 43065 P: (740) 97-578 F: (740) 97-579 www.genesisutomationonline.com Sales@GenesisutomationOnline.com