FC Series Signal Conditioners

Similar documents
FC-33, DC SELECTABLE SIGNAL CONDITIONER

Temperature Transmitters - DIN Rail Mounted

Temperature Transmitters - Head Mounted

P1-04THM Analog Input

This Errata Sheet contains corrections or changes made after the publication of this manual.

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

CONTA-ELECTRONICS. Converter Units

DRG-SC Series Signal Conditioners

P1-04ADL-2 Analog Input

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

MODEL AT-10 ANALOG TRANSMITTER

F4 16DA 2 16-Channel Analog Voltage Output

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

Industrial Interface The Signal Conditioning People

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

P1-04DAL-1 Analog Output

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

FOUNDATION Fieldbus Junction Box

TxBlock-USB Transmitter

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

5069 Compact I/O Modules Specifications

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

F4 04DAS 1 4-Channel Isolated 4 20mA Output

em4 em4 alert em4 alert 2G

Multifunction Intelligent 4-wire Isolated Signal Conditioner

Electronic Circuit Breaker with reset input ESS20-1..

F4 08DA 2 8-Channel Analog Voltage Output

em4 local - Robust Specific characteristics Part number

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Assembly. Front view. Parametrization interface. Power Bus

XM Monitoring Modules Specifications

SMART TEMPERATURE TRANSMITTERS. smar

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

B850 Boiler House Energy Monitor

MODEL: W2TS. Mini-MW Series

Installation and Operating Manual

02/11/2015

Electronic timer CT-TGD.22

S200 I/O System Units

2002-ALM USER MANUAL

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

F4-04DA-1 4-Channel Analog Current Output

F4-08RTD 8-Channel RTD Input

Temperature transmitter itemp RTD DIN rail TMT 127

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

B850 Boiler House Energy Monitor

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

WHEN A PLC IS TOO MUCH, AND SPACE FOR

02/11/2015

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

Type CP-S, CP-C & CP-A Switch mode

Paperless Recorder PR20

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

Encoders. Up-to-date price list: FREE Technical Support:

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

Temperature Measurement

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

P5201 Universal Programmable Transmitters with Galvanic Isolation

Temperature Measurement Transmitters for mounting in sensor head

VELTRON II Microprocessor Based Pressure & Flow Smart

02/11/2015

Electronic timer CT-SDD.22

HART Compatible Intelligent 2-wire DIN Rail Transmitters

Miniature Temptran RTD Transmitters

INSTRUCTION SHEET. Eaton Logic Controller ELCM TC Temperature Modules. [Applicable Temperature modules] ELCM-TC04ANNN MTN1

MODEL: R30US4. Remote I/O R30 Series

Multi-voltage Multi-function. Wiring diagram (without control signal)

Temperature Measurement

Temperature head transmitter itemp TC TMT 188

Non-Submersible Industrial Pressure Transducer

1715 Redundant I/O System Specifications

High Performance Process & Temperature Controllers

ITP16. Temperature indicator. User guide

38 Series - Relay interface modules A. Features /

DC Current Transducers

02/11/2015

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase

Temperature Measurement Transmitters for mounting in sensor head

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

OPTITEMP TT 20 Technical Datasheet

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

MINI 048 / JUN 2003 PAGE 1. Temperature I/O Module HE500OCS048 / HE500OCS078 HE500RCS078

This Errata Sheet contains corrections or changes made after the publication of this manual.

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

Section 11 Electronic Position Controls & Encoders

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

Transcription:

FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between input and output, and 1500 VDC isolation from 24 volt power and input/output. LED indicates normal operation and is used in conjunction with the calibration pushbutton for the internal calibration process. 3-way 1500 V isolation Push button calibration FC-T1 Thermocouple/mV Isolated Signal Conditioner Field configurable input for type J, K, E, T, R, S, B, N and C thermocouples or ±156.25 mv inputs with 1500 VDC isolation between input and the 4-20 ma output. Cold junction compensation and burnout detection. Alarm/run LED. 1500 V isolation Cold junction compensation (CJC) Internal diagnostics (burnout detection or calibration errors) FC-P3 Potentiometer Input, Analog Output Signal Conditioner Field configurable input and output, input ranges of 3-wire potentiometer 0 to 100 ohms through 0 to 100 kilohms, and output ranges of 0-5V, 0-10 V, 0-20 ma or 4-20 ma. Field calibrated to 10% of potentiometer full range. Bipolar Voltage to Unipolar Voltage or Signal Conditioner Field configurable input and output, bipolar input ranges of ±100 mv, ±50 mv, ±5V, ±1, ±15V, and unipolar output ranges of 0-5V, 0-10 V, 0-20 ma or 4-20 ma. Field calibrated with offset and span adjustments. FC-ISO-D Encoder Signal Conditioner and Optical Isolator - Differential Line Driver Output Ideal for use with single-ended (open collector, NPN, pull-up, push-pull, totem pole) or differential line driver encoders. Three complementary inputs (A, B, Z, A-not, B-not, Z-not) are rated for 4.5-7.5 and 12-26 VDC and frequency response up to 1 MHz. Optical isolation separates the input signals from three differential line driver outputs (A, B, Z, A-not, B-not, Z-not) rated for 5VDC. FC-11 4-20 ma Isolated Signal Conditioner Loop powered 4-20 ma input/output signal with 1500 VDC isolation between input and output. 1500 V isolation Loop powered FC-R1 RTD Input Signal Conditioner Loop powered, non-isolated, 3-wire unit converts an RTD input to a linear 4-20 ma signal. User selectable CU10, PT100 or PT1000 input. Unipolar Voltage or to Bipolar Voltage Signal Conditioner Field configurable input and output, unipolar input ranges of 0-5V, 0-10 V, 0-20 ma or 4-20 ma, and bipolar output ranges of ±100 mv, ±50 mv, ±5V, ±1, ±15V. Field calibrated with offset and span adjustments. FC-ISO-C Encoder Signal Conditioner and Optical Isolator - Open Collector Output Ideal for use with single-ended (open collector, NPN, pull-up, push-pull, totem pole) or differential line driver encoders. Three complementary inputs (A, B, Z, A-not, B-not, Z-not) are rated for 4.5-7.5 and 12-26 VDC and frequency response up to 1 MHz. Optical isolation separates the input signals from three complementary open collector outputs (A, B, Z, A-not, B-not, Z-not) rated for 5-36 VDC that can be used in single-ended configurations. eps-14

Unipolar Voltage or to Bipolar Voltage Signal Conditioner $129.00 Overview UL file E157382 The is a 35 mm DIN-rail or side-mount, selectable unipolar input to bipolar output signal conditioner with isolation between input and output, and isolation between 24-volt power and input/output. The field configurable isolated signal conditioner is useful in eliminating ground loops and interfacing sensors to PLC analog input modules. It translates unipolar voltage inputs or current inputs to bipolar voltage outputs. The input and output signal levels are selected via DIP switches. In addition, the outputs can be either a direct conversion of the inputs or an inversion (a reverse acting operation). The user also has the option of customizing the input OFFSET (zero) and SPAN (full scale) adjustments that can be set to a percentage of the full scale via a pushbutton on the front panel. Specifications Input Specifications Input Ranges 0-5V, 0-10 V, 0-20 ma, 4-20 ma (DIP Switch Selectable/Invertable) Input Impedance 410 kilohm voltage input, 250 ohm current input Protection Type, Component Polarity Protection Diode External DC Power Required DC ±10%, 40 ma, Class 2 User Calibration Range OFFSET (zero): 0-20% (e.g. 0-1. / 5V mode) SPAN (full-scale): 80-102% (e.g. 4.0-5.1V / 5V mode) Output Specifications Output Ranges ±50 mv, ±100 mv, ±5V,, ±15 V Load Impedance 2 kilohm Minimum Sample Duration Time 10 ms Maximum Inaccuracy 0.1% FSO @ 25 C (1.0% 50 mv / 100 mv) Accuracy vs. Temperature ±60 PPM of Full Scale / C Maximum ±50 mv/±100 mv @ 2.5mA max, Output ±5V,, ±15 V @ 7.5mA max Terminal Block Specifications Field Wiring Removable Screw Type Terminal Blocks (Included) 2 (Dinkle: EC35-02P), 3 (Dinkle: EC35-03P), Number of Positions 6 (Dinkle: EC35-06P) 28-14 AWG solid or stranded conductor; Wire Range wire strip length 1/4 (6-7mm) Screw Torque 1.7 inch-pounds (0.19 Nm) General Specifications 0 to 60 C (32 to 140 F) Surrounding Air Temperature IEC 60068-2-14 (Test Nb, Thermal Shock) -20 to 70 C (-4 to 158 F) IEC 60068-2-1 (Test Ab, Cold) Storage Temperature IEC 60068-2-2 (Test Bb, Dry Heat) IEC 60068-2-14 (Test Na, Thermal Shock) Enclosure Rating IP20 5 to 95% (non-condensing) Humidity IEC 60068-2-30 (Test Db, Damp Heat) No corrosive gases permitted Environmental Air (EN61131-2 pollution degree 1) MIL STD 810C 514.2 Vibration IEC 60068-2-6 (Test Fc) MIL STD 810C 516.2 Shock IEC 60068-2-27 (Test Ea) Insulation Resistance >10M @ 50DC NEMA ICS3-304 IEC 61000-4-2 (ESD) Impulse 1000 V @ 1µS pulse Noise Immunity IEC 61000-4-4 (FTB) RFI, (145 MHz, 440 MHz 5W @ 15 cm) IEC 61000-4-3 (RFI) Weight 0.3lbs 1800 VDC Power to Input 1800 VDC Power to Output Isolation 1800 VDC Input to Output applied for 1 second (100% tested) Agency Approvals UL508*, File Number: E157382, CE * In order to comply with UL508, the supplied power must be less than 26 VDC and fused at a maximum of 3 amps. eps-22

Application Example 1 Use the to convert a unipolar output from a PLC analog card to a bipolar DC signal to control a SureServo s External Velocity Command. OUT F2 -- 02DA -- 1 18-3DC 60mA ANALOG OUT 4-20mA +24V CH1-- CH1+ CH2-- CH2+ F2--02DA--1 4-20 ma ANALOG 2CH Applications and Dimensions 4-20mA I+ 24V ±mv ±5V ±1 ±15V OUT (V) 10 0-10 4 12 DIP Switch Input DIP 1 2 3 4 5 6 7 8 Setup 0 0 1 0 0 0 1 0 12345678 DIP Switches INPUT (ma) 20 Application Example 2 Use the to convert and isolate a unipolar output from a 4-20 ma sensor or transmitter to a bipolar DC signal for a PLC input. Company Information Drives Soft Starters Motors Power Transmission Motion: Servos and Steppers Motor Controls Proximity Photoelectric Encoders Limit Switches PLC Analog Output Module Set For 4-20 ma Input Output Pressure *CAUTION: Product may be damaged if multiple outputs are tied together. Wiring Connections Input Terminal Block Voltage In I+ In Common NOTE: and I+ must be jumpered for input + - Analog Input SureServo Drive Output Terminal Block ±mv TM ±50 mv or ±100 mv Output Connection (used with mv signals) ±5V ±5V Output Output ±15 V ±15 V Output Connection (used with non-mv signals) External Power Terminal Block DC ±10% (Class 2) Switch/LED s Diagnostic LED flashing indication Push button switch input to initiate calibration, etc. Temperature Level Flow Switches Pushbuttons and Lights Stacklights Signal Devices Process Relays and Timers Dimensions Air Prep inches [mm] Directional Control Valves Cylinders Tubing Air Fittings Appendix Book 2 Terms and Conditions w w w. a u t o m a t i o n d i r e c t. c o m / s i g n a l - c o n d i t i o n e r s Process Control eps-23

$129.00 Overview Bipolar Voltage to Unipolar Voltage or Signal Conditioner UL file E157382 The is a 35 mm DIN-rail or side-mount, selectable bipolar input to unipolar output signal conditioner with isolation between input and output, and isolation between 24-volt power and input/output. The field configurable isolated signal conditioner is useful in eliminating ground loops and interfacing sensors to PLC analog input modules. It translates bipolar voltage input to unipolar voltage output or bipolar voltage input to a current output. The input and output signal levels are selected via DIP switches. In addition, the outputs can be either a direct conversion of the inputs or an inversion (a reverse acting operation). The user also has the option of customizing the input OFFSET (zero) and SPAN (full scale) adjustments that can be set to a percentage of the full scale via a pushbutton on the front panel. Specifications Input Specifications Input Ranges ±15 V,, ±5V, ±100 mv, ± 50 mv (DIP Switch Selectable) Input Impedance 2 M ohm Protection Type, Component Polarity Protection Diode External DC Power Required DC ±10%, 50 ma, Class 2 User Calibration Range OFFSET (zero): 0-20% (e.g. -4V / ±5V mode) SPAN (full-scale): 80-102% (e.g. 4.0-5.1V / ±5V mode) Output Specifications Output Ranges 0-5V, 0-10 V, 0-20 ma, 4-20 ma (DIP Switch Selectable) Load Impedance 2 kilohm Minimum, Voltage Output 550 ohm Maximum, Output Sample Duration Time 10 ms Maximum Inaccuracy 0.1% FSO (±15 V,, ±5V Inputs), 1.5% FSO ( ±100 mv, ±50 mv Inputs) @ 25 C Accuracy vs. Temperature +/-60 PPM of Full Scale/ C Maximum Output 21 ma max for ma-out mode/ 10 ma max for Volt-out mode Terminal Block Specifications Field Wiring Removable Screw Type Terminal Blocks, (included) Number of Positions 2 (Dinkle: EC35-02P), 2 (Dinkle: EC35-02P), 4 (Dinkle: EC35-04P) Wire Range 28-14 AWG solid or stranded conductor; wire strip length 1/4 (6-7mm) Screw Torque 1.7 inch-pounds (0.19 Nm) General Specifications Surrounding Air Temperature 0 to 60 C (32 to 140 F) IEC 60068-2-14 (Test Nb, Thermal Shock) -20 to 70 C (-4 to 158 F) Storage Temperature IEC 60068-2-1 (Test Ab, Cold) IEC 60068-2-2 (Test Bb, Dry Heat) IEC 60068-2-14 (Test Na, Thermal Shock) Enclosure Rating IP20 Humidity 5 to 95% (non-condensing) IEC 60068-2-30 (Test Db, Damp Heat) Environmental Air No corrosive gases permitted (EN61131-2 pollution degree 1) Vibration MIL STD 810C 514.2 IEC 60068-2-6 (Test Fc) Shock MIL STD 810C 516.2 IEC 60068-2-27 (Test Ea) Insulation Resistance >10 M Ω@ 500 VD C NEMA ICS3-304 IEC 61000-4-2 (ESD) Noise Immunity Impulse 1000 V @ 1µS pulse IEC 61000-4-4 (FTB) RFI, (145 MHz, 440 MHz 5W @ 15 cm) IEC 61000-4-3 (RFI) Weight 0.3lbs 1800 VDC Power to Input Isolation 1800 VDC Power to Output 1800 VDC Input to Output applied for 1 second (100% tested) Agency Approvals UL508*, File Number: E157382, CE * In order to comply with UL508, the supplied power must be less than 26 VDC and fused at a maximum of 3 amps. eps-24

Application Example 1 The can be used to convert a bipolar DC signal to a 4-20 ma signal. IN F2 -- 02DA -- 2 10-3DC 5mA +24V CH1-- CH1+ CH2-- CH2+ CH3 - CH3+ CH4 - CH4+ ANALOG IN 0-5, 0-1DC +/-5, +/-1DC Set for Output ANALOG 4CH PLC Analog Output Module POWER SUPPLY + Applications and Dimensions 4-20 ma Device *CAUTION: If current output (I+/I-) and Voltage output (/V-) are both connected to loads and/or the I+ terminal to the V- terminal, product damage may occur. V- 24V I+ I- V- Set for Input and 4-20 ma Output 20 OUT 12 (ma) 4 DIP Switch Input DIP 1 2 3 4 5 6 7 8 Setup 1 0 0 0 1 1 0 0 12345678 DIP Switches -10 0 INPUT (V) +10 Application Example 2 The can be used to convert the bipolar DC from a DCT100-10B-24S current transducer to a 4-20 ma or 0-10 VDC that can be used by a PLC. Company Information Drives Soft Starters Motors Power Transmission Motion: Servos and Steppers Motor Controls Proximity Photoelectric Encoders Limit Switches Pressure Temperature Wiring Connections Level Input Terminal Block Signal In + V- Signal In - Output Terminal Block I+ I- Voltage V- Voltage External Power Terminal Block DC ±10% (Class 2) Switch/LED s Diagnostic LED flashing indication Pushbutton switch input to initiate calibration, etc. Flow Switches Pushbuttons and Lights Stacklights Signal Devices Process Dimensions inches [mm] Relays and Timers Air Prep Directional Control Valves Cylinders Tubing Air Fittings Appendix Book 2 Terms and Conditions w w w. a u t o m a t i o n d i r e c t. c o m / s i g n a l - c o n d i t i o n e r s Process Control eps-25