Ariadna CI MV & LV cable identifier

Similar documents
Ariadna Instruments. Power cable identifier & LV live network phase and feeder identifier

Cable Identifier Reliable cable selection for energised and de-energised cables

vscan Data Sheet V1.0

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2

UAT-600 Series. amprobe.com

Flexible AC current probes

UTILITY LOCATING EQUIPMENT

Končar TMS - Bushing monitoring

Quick Start Guide AT-6000 Advanced Wire Tracer Series

AT-7000 Advanced Wire Tracer

Cable Identifying Generator LCI TX / LCI TX-440

CP 6632 Handheld process signal calibrator

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

DC Electronic Loads 8500 Series

HAWK5000 Operators Manual

Zentralbaugruppen CPU 222

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Proximity Sensor Terminology

Winding Ohmmeter & Tap Changer Test Set RMO10TW

AT-5000 Professional Underground Cable / Pipe Locator System

B850 Boiler House Energy Monitor

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

AC2000 AMPLIFIER PLATFORM

Fluke 355 and 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents

High precision measurement system for current and voltage IHC-A/B-RM01/03

B850 Boiler House Energy Monitor

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Remote Radio Control. M880 WAVE2 C Transmitter Range. M880 for Low Integrity Stop Circuit Applications

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

EMC of Power Converters

Integrated servo motor

CXE880 FIBRE OPTIC NODE

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

SDM3045X Digital Multimeter. DataSheet

AC500 AMPLIFIER PLATFORM

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

PRECISION CLAMP ON FLEXIBLE ROGOWSKI COIL CURRENT TRANSFORMER

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

AC1000 AMPLIFIER & OPTICAL NODE PLATFORM

3B SCIENTIFIC PHYSICS

Indeks: WMGBMRU30 Earth Resistance and Resistivity Meter

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV

DM-III MULTITEST Power Quality Recorder

Integration between the MV protection and control unit REF542 and the LV protection trip unit PR123: selectivity and earth fault 1SDC007402G0201

DM-III Multitest & DM-III Multitest F Power Quality Recorders

VARAN Stepper Module VST 012

PROXIMITY SENSOR TERMINOLOGY

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

Advanced Test Equipment Rentals ATEC (2832)

Loc-5Tx Data Sheet V2.1

CXE880 FIBRE OPTIC NODE

WHY YOU NEED A CURRENT BALUN

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

Level Limit Switch nivotester FTL 325 P

Digital Grid Products. SICAM Fault Sensor Indicator (FSI) The Guardian for your Overhead Line Networks

1587/1577 Insulation Multimeters

Fluke 3540 FC Three-Phase Power Monitor

NADIR USER'S GUIDE. September 2009 MADE - V 3.20

SOLAR300N Rel /01/10

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

Bonding And Loop Resistance Tester >blrt3<

Fluke 3540 FC Three-Phase Power Monitor

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05

PQM3000R Class A network analyzer according to EN for power quality monitoring

True RMS Digital Multimeter Model:

My-IDENT... Industrial Identification Program. High performance RFID. MEYLE: Know-How, Know-Where, Know-When RADIO FREQUENCY IDENTIFICATION

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

Wireless Transceivers for Fuel Level Sensors RUd-DF-232 RUd-DF-485. Instruction Manual Version # 2.1 VTAS IM

GFL-1000 User Manual Ground Fault Locator

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

ROG4K. EM210 energy analyzer current sensor ( A) Benefits. Description

Indeks: WMXXCMM60 Advanced Industrial Multimeter

FLOMID FX Electromagnetic Flowmeter

Digital Clamp Meter Model: &

Digital Ground Resistance Tester. Model 4610 & 4610 Kits

BENNING. CM7 Electrical Tester. Service Information

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

CXE880 FIBRE OPTIC NODE

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

3B SCIENTIFIC PHYSICS

Technical description MT24. User manual WARNING GENERAL INSTRUCTIONS GENERAL DESCRIPTION

TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers

Family 400 meters Rel /04/2007

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Data Sheet GTD21148L SERIES 40W. (201) Switching Power Supplies

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

SGD-EEM «MEDUSA» GEOELECTRICAL MULTIFUNCTION RECEIVER

Tuningintobetter power quality

400 Va.c., 500 Va.c., 690 V a.c. Rated current I n. 120 ka

Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies

Mini Clamp Meter Model:

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole

270 manual.qxd 5/9/2005 3:04 PM Page 1. Digital Clamp-on Meter Instruction Manual

RADIO REMOTE SYSTEMS

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Transcription:

Ariadna CI MV & LV cable identifier In electrical maintenance works, in order to cope with safety standards, it becomes necessary to identify de-energized cables unambiguously prior to its manipulation. Cutting the wrong cable may result in the following consequences: personnel live threat power supply failure ARIADNA CI cable identifier is an advanced, yet simple to operate, digital tool. It helps users to easily identify de-energized and energized MV&LV cables electrical cables among multiple conductors, in trenches, manholes, panels, aerial/underground conversions, etc. Main Features: CI-TX CI-RX Identifies: o energized MV cables o energized LV cables o de-energized MV and LV cables Works with: o Single phase conductors (shielded or unshielded) o Three phase or 3 phase + neutral conductor Signal injection by: o Direct connection to cables o Signal induction through toroidal clamp (optional) Detects active signal s Amplitude and Polarity Maximum cable length > 10km (direct connection) Rechargeable Li-ion battery on transmitter (CI-TX): >24h at level 2 (up to 4) of transmission power

Energized MV cable identification It works by sinking energy from a live network, by connecting a load at the LV side of an MV/LV transformer, and detecting the current that is produced at the MV side of the transformer. The CI-TX unit acts as the signal transmitter that sinks energy from the electric grid, producing coded current pulses, and the CI-RX unit as the digitally tuned receiver that detects them.

Energized LV cable identification In a similar way to MV live cable identification, it is possible to identify LV energized cables by sinking current from the network. CI-TX transmitter is connected at the end side of the LV cable to be identified. When turned on, it starts to sink current pulses from the network, and these pulses flow from the point of injection to the LV transformer that feeds it. With the CI-RX unit it is possible to identify LV cable path in any accessible places, like manholes, busbars, etc.

De-energized MV & LV cable identification Through polarized frequency signal injection and detection, it is possible to positively identify de-energized cables. Unlike live cable identification, the needed energy for generating identification signals come from CI-TX s rechargeable li-ion battery, instead of coming from the grid. Two ways are available for injecting signals on cables, through direct connection or by using a toroidal inductive clamp. Afterwards cables are identified by measuring produced signal s amplitude and polarity.

* Technical Specs CI-TX CI-RX Size 315x255x150 mm Size 120 x 220 x 65 mm Weight 3 kg Weight 0.75 kg Protection degree IP65 Protection degree IP54 Display Monochrome 160x100 Display Color TFT 240x400 Rechargeable battery 8.4V 6.6Ah Li-ion Batteries 4x1,5V AA Battery charger input 100-240VAC 50/60Hz Operating Temperature -10ºC a 55ºC Battery charger output Car lighter charger 12VDC 2A Yes Operating Temperature -10ºC a 55ºC Fuse at the end of the mains leads 6.3x32 mm 10A 500V 50KA type F Energized Cables Signal type Current pulses Active signal analysis (from TX) amplitude and polarity Injected signal amplitude 160/80A peak Passive current measurement 50/60Hz RMS Max. network voltage 440Vac Max. network current (50/60Hz) 1800A RMS (Rog) Operation time >24h Maximum cable length >10km De-energized cables Signal type current frequency Active signal analysis (from TX) amplitude and polarity Active signal power 10W Maximum cable length >20km Operation time (level 2) >24h Max. loop resistance 1000 Ω * Specifications subject to change without notice Ariadna CI detects medium and low-voltage cables (energized or de-energized), and complies with the following safety standards: - Electromagnetic compatibility: EN 61000-6-3, EN 61000-6-2. - Electrical safety: EN 61010-1 CAT IV 300V. Protection against electric shock. Class II. Power cable identification and location solutions