Advanced Technology and Manufacturing Institute. Zygo ZeScope

Similar documents
R I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS

Zygo Optical Interferometer SOP

Before you start, make sure that you have a properly calibrated system to obtain high-quality images.

Basic Operator Procedure Training NewView 6300 GROWING IN A SHRINKING WORLD

Bruker Optical Profilometer SOP Revision 2 01/04/16 Page 1 of 13. Bruker Optical Profilometer SOP

Stitching MetroPro Application

1.1. Log on to the TUMI system (you cannot proceed further until this is done).

Figure 1 The Raith 150 TWO

Olympus LEXT OLS 4000 Confocal Laser Microscope

Measurement of Surface Profile and Layer Cross-section with Wide Field of View and High Precision

Cube in a cube Fusion 360 tutorial

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )

KEYENCE VKX LASER-SCANNING CONFOCAL MICROSCOPE Standard Operating Procedures (updated Oct 2017)

1. Preliminary sample preparation

STEM Spectrum Imaging Tutorial

LECTURE 26: Interference

ThermaViz. Operating Manual. The Innovative Two-Wavelength Imaging Pyrometer

ISCapture User Guide. advanced CCD imaging. Opticstar

SPECTRALIS Training Guide

-f/d-b '') o, q&r{laniels, Advisor. 20rt. lmage Processing of Petrographic and SEM lmages. By James Gonsiewski. The Ohio State University

CHROMACAL User Guide (v 1.1) User Guide

Training Guide for Carl Zeiss LSM 7 MP Multiphoton Microscope

Nikon Capture NX "How To..." Series

Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series

LSM 780 Confocal Microscope Standard Operation Protocol

Image Processing Tutorial Basic Concepts

SUPRA Optix 3D Optical Profiler

This procedure assumes the user is already familiar with basic operation of the SEM and the MiraTC interface.

ScanArray Overview. Principle of Operation. Instrument Components

MEASUREMENT CAMERA USER GUIDE

Leica TCS SP8 Quick Start Guide

Build the clerestory of Chartres Cathedral

The original image. Let s get started! The final effect.

RENISHAW INVIA RAMAN SPECTROMETER

Automated workflow for Core Saturation experiment

Quick Operation Guide

Operating Procedures for MICROCT1 Nikon XTH 225 ST

LEICA TCS SP5 AOBS TANDEM USER MANUAL

Leica DMi8A Quick Guide

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

Confocal imaging on the Leica TCS SP8. 1) Turn the system on. 2) Use TCS user account. 3) Start LAS X software:

Version 6. User Manual OBJECT

LumaSpec 800S User Manual

Large Field of View, High Spatial Resolution, Surface Measurements

Characterization Microscope Nikon LV150

PlanSwift 3D Viewer Plugin User Guide

AgilEye Manual Version 2.0 February 28, 2007

FEI Helios NanoLab 600 TEM specimen prep recipe Nicholas G. Rudawski (352) (office) (805) (cell) Last updated: 01/19/17

Training Guide for Carl Zeiss AxioZoom V16 Stereo Microscope

Standard Operating Procedure

There are two types of cove light in terms of light distribution inside a room

Creo Extrude Tutorial 3: Hole, Fillets and Rounds

Welcome 1. Precaution

AutoCAD 2020 Fundamentals

LSM 710 Confocal Microscope Standard Operation Protocol

Fire CR Calibration Guide

Imaging Processing with Pax-it Software (Analyzing the Percentage of Carbon Content)

The End of Thresholds: Subwavelength Optical Linewidth Measurement Using the Flux-Area Technique

Bringing Answers to the Surface

Operating Instructions for Zeiss LSM 510

Superfast phase-shifting method for 3-D shape measurement

g. Click once on the left vertical line of the rectangle.

Records the location of the circuit board fiducials.

Box Tray Geometry in MasterCAM

Gravitational Lensing Experiment

Information & Instructions

Operating Checklist for using the Laser Scanning Confocal Microscope. Leica TCS SP5.

Leica TCS SP8 Quick Start Guide

Zeiss LSM 780 Protocol

Y N C R O S C O P Y A DIVISION OF THE SYNOPTICS GROUP

Zeiss LSM 510 Confocor III Training Notes. Center for Cell Analysis & Modeling

Zeiss 880 Training Notes Zen 2.3

PANalytical X pert Pro High Resolution Specular and Rocking Curve Scans User Manual (Version: )

Photo Maker. User Manual

Index of Command Functions

1. Create a 2D sketch 2. Create geometry in a sketch 3. Use constraints to position geometry 4. Use dimensions to set the size of geometry

User Guide of Tsview 7

Surface Finish Measurement Methods and Instrumentation

SpeedMark Tutorial 4 Using the rotary indexer

Adobe Illustrator. Mountain Sunset

Dynamic Phase-Shifting Microscopy Tracks Living Cells

NIS-Elements: Grid to ND Set Up Interface

Turnkey Solution for Technical Cleanliness Inspection

TN378: Openlab Module - FRET. Topic. Discussion

Importing and processing gel images

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

Adobe Photoshop. Levels

4.5.1 Mirroring Gain/Offset Registers GPIO CMV Snapshot Control... 14

Sense. 3D Scanner. User Guide. See inside for use and safety information.

Introduction to CATIA V5

Colouring in CAD s. Photoshop. December 2012

Swept-Field User Guide

VOLLSTÄDT DIAMANT GmbH. DiaInspect.OSM Automated particle analysis for superabrasives and surface analysis. Operation guide Version 1.2.

Arcturus XT Laser Capture Microdissection System AutoScanXT Software Module. User Manual

Chapter 7. Optical Measurement and Interferometry

ABC Math Student Copy. N. May ABC Math Student Copy. Physics Week 13(Sem. 2) Name. Light Chapter Summary Cont d 2

Digital Photography 1

ENSC 470/894 Lab 3 Version 6.0 (Nov. 19, 2015)

Simplified Instructions: Olympus Widefield Microscope S1230

Transcription:

Advanced Technology and Manufacturing Institute Zygo ZeScope Created by Andrew Miller ATAMI Oregon State University Revision Date Description Curator 0 8/31/2018 New Document Andrew Miller

Zygo ZeScope OSU ATAMI 2 Table of Contents Introduction... 2 Description... 2 Precautions... 2 Operation... 3 Start Up... 3 Data Acquisition... 6 Data Improvement... 10 Sequencing... 12 Introduction The purpose of this document is to provide guidance on the operation of the Zygo ZeScope at the Advanced Technology and Manufacturing Institute. This manual is meant to be used in conjunction with the ATAMI Client Training and Tool Use Guidance. Description The Zygo ZeScope is an optical profiler and is used to precisely measure the height differences on a surface. Optical profiling splits a beam of light which then is reflected off of a reference surface and the test surface. When the two beams are reflected back, constructive and destructive interference occurs. The interference creates light and dark bands or interference fringes. Using the interference fringes and the wavelength of the light, a three-dimensional map of the test surface is created. Precautions LOWERING THE ZESCOPE: When lowering the Zygo ZeScope take care to avoid ramming the ZeScope into your part. This can damage the ZeScope. MOVING PARTS: Avoid impeding the movement of the ZeScope tray and this may damage the machine. ANTI-VIBRATION TABLE: Do not lean on the ZeScope table as this will cause the table to rock and will reduce the quality of the data collected.

Zygo ZeScope OSU ATAMI 3 Operation Start Up Turn on the ZeScope by double clicking the ZeScope icon. Initially a large page will pop up across the entire screen. Close this page.

Zygo ZeScope OSU ATAMI 4 The ZeScope will check all the devices to make sure they are working properly. If all the devices Pass, the start up will continue. If all the devices to not Pass try turning off the ZeScope and the Joystick and trying again. After all the devices have been checked, another pop-up will appear. Click Yes. This process may take a minute.

Zygo ZeScope OSU ATAMI 5 Next a pop-up will prompt you to pick a recipe to use. Select Open Default Recipe. Now you will see this screen pop up and you will be ready to look at your part.

Zygo ZeScope OSU ATAMI 6 Data Acquisition Move the ZeScope to the loading position by selecting Move To Load Position Place your part onto the ZeScope. Move the ZeScope to the measuring position by selecting Move To Measure Position Select the desired magnification.

Zygo ZeScope OSU ATAMI 7 Select the desired speed for the joystick. Use the XY-joystick to focus the ZeScope over your part. It will be easiest to start with high speed and switch to low speed once your part is close to the desired position.

Zygo ZeScope OSU ATAMI 8 Next use the Z-joystick to lower the ZeScope. Stop lowering the ZeScope once your part comes into focus. The part is in focus when waves appear on the screen. For reference, here are the values where the ZeScope focuses on the surface of the tray: Magnification Lens Focus Height (mm) 5X 177.570 10X 177.642 20X 177.105 An easy way to make use of this table is to measure the thickness of your part, then subtract that thickness from the focus height of the desired magnification lens.

Zygo ZeScope OSU ATAMI 9 To acquire data for your part select Acquire Tools Acquire Options Change the Surface to Rough Scan. Change the Scan Position to Top. Change the Scan Length to twice the depth of your features. Select Start Acquire. If the scan does not produce adequate results, select Thresh and adjust the threshold. Additionally, increasing the number of Data Averages will improve the scan quality. However, this will also significantly increase the time to complete a scan.

Zygo ZeScope OSU ATAMI 10 Data Improvement Now that you have acquired the scan, there are a few ways to improve it. First to make the scan 3 dimensional select the triangle-square-circle icon. Next select the Process Map icon. Select Fill Void Pixels

Zygo ZeScope OSU ATAMI 11 Select Fill all pixels within a boundary, then select Apply. To use the level tool select Levels Level Tool Drag the white rectangle over an area that is level. Right click and select Remove Tilt

Zygo ZeScope OSU ATAMI 12 Sequencing To create a sequence, select Sequence Stage Options. Next select Stitch.

Zygo ZeScope OSU ATAMI 13 Now adjust the number of rows and columns in your sequence. Then select Ok. Now, once you have selected Acquire Tools Acquire Options, select Start Sequence.