ICP-MS. plasma 3. Multi-Collector ICP-MS.

Similar documents
NEPTUNE Plus Multicollector ICPMS. Another step ahead. in MC-ICP-MS. Earth and Planetary Sciences Nuclear Sciences

TRITON Plus Thermal Ionization MS. Another step ahead. in TIMS. Earth and Planetary Sciences Nuclear Sciences

Technical Specifications for the procurement of Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

HIQUAD. New high-end mass spectrometer! Fast, flexible and easy to operate.

Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design

LC/MS/MS. Page Header. triple quadrupole mass spectrometer.

Simplicity. Reliability. Performance. ProdigyPlus

PRISMAPRO. The latest generation of compact mass spectrometers. Modular design. Powerful software. Low detection limit.

HPR-30 Vacuum Process Gas Analyser A differentially pumped RGA system for vacuum process monitoring

Performance characteristics of a new wide range, fast settling electrometer design for a residual gas analysis mass spectrometer

PRISMAPLUS. The precise solution for mass spectrometry. Modular design. Powerful software. Wide range of applications.

Collision cell: Fragmentation efficiency > 90 % Duty cycle: Variable between 1 and 50 % (user selectable trapping time/scan time ratio) Transmission:

The Extrel MAX Systems are UHV-compatible flange mounted Quadrupole Mass

Mass Spectrometry and the Modern Digitizer

PrismaPlus. The New Mass Spectrometer with the Added Plus! Modular Design. Powerful Software. Wide Range of Applications.

Dynamic time correction for high precision isotope ratio measurements

Product Range Electronic Units

830 Vacuum Quality Monitor

Characterization of Common Electron Multipliers in Harsh Environments

True simultaneous ICP-OES for unmatched speed and performance

KNOW TRAINING MORE WITH. PerkinElmer Training Catalogue 2013 Relevant, interactive, rich in content.

Residual Gas Analyzers XT Series

Prodigy DC Arc The Ultimate Solution for Elemental Analysis of Solid Samples

The 5975C Series MSDs: Normalized Instrument Tuning. Technical Overview. Introduction

Residual Gas Analyzers RGA100/200/ amu, 200 amu and 300 amu RGAs

Residual Gas Analyzers

Ultrasensitive LC MS/MS: Agilent 6470 and 6495 LC-QQQ

835 Vacuum Quality Monitor (VQM TM ) 2012 Brooks Automation, Inc. Proprietary Information

Superior ICP-OES optical design for unmatched speed and performance

Transpector 2. Gas Analysis System. NEW-GENERATION RGAs WITH SUPERIOR SENSITIVITY AND PERFORMANCE

Solid-State Upgrade for the COBRA JUDY S-Band Phased Array Radar

Aurora Group of Companies

Introduction of New Products

Autoresonant Trap Mass Spectrometry

Subminiature Photoionization VOC Sensor Boris Dolgov, Baseline-MOCON, Inc.

Improving Signal-to-Noise by Identifying Sources of Noise in Mass Spectrometer Systems

Electron Multipliers. Introduction to ETP Electron Multipliers Selection by Technique: LC-MS 242

Introducing the Agilent 7000A Triple Quadrupole GC/MS

QUANTOF. High-resolution, accurate mass, quantitative time-of-flight MS technology

A New Class of Robust Sub-nanosecond TOF Detectors with High Dynamic Range

Prodigy DC Arc. The Ultimate Solution for Elemental Analysis of Solid Samples

Physical Properties Measurement System (PPMS): Detailed specifications: Basic unit cryogen- free

A Penning Trap for Precision Spectroscopy of Highly Charged Ions at HITRAP. Jörg Krämer University of Mainz

DUOLINE. Rotary vane pumps for all applications in the low and medium vacuum range

FT-IR.

REAL-TIME DUST MONITOR FOR INDOOR AIR QUA- LITY MEASUREMENTS AND WORKPLACE EXPOSURE ASSESSMENTS FIDAS

High specification CCD-based spectrometry for metals analysis

Ion optics innovations for increased sensitivity in hybrid MS systems

A New Conjoined RF Ion Guide for Enhanced Ion Transmission

Historical. McPherson 15 Mount

The Development of Miniature Electron Multipliers for Use In Portable Mass Spectrometers

CRL MASS SPECTROMETRY FACILITY INSTRUMENT USER MANUAL MALDI MICRO. Operating Instructions. Basement Spec Lab:

Fiber Laser Chirped Pulse Amplifier

IL550 & IL560 Series Optical Monitors for The ULTIMATE in Thin Film Coating Precision, Accuracy & Control

Next Generation Space Atomic Clock Space Communications and Navigation (SCaN) Technology

Cylindrical Toroidal Ion Trap Mass Spectrometer. Daniel Austin and Nick Taylor Brigham Young University, Provo, Utah

The Perfect Solution for Mass Spectrometry. Modular Design. Powerful Software. Wide Range of Applications.

SPECTROLABLAVM11. Performance Meets Flexibility: The Best in Metal Analysis

Then the mass spectrometer should go to the field, in your hand, small as possible, light as possible, and operated with light battery.

Development of a Small Residual Gas Analyzer Utilizing the Quadrupole Array Structure Micropole System ~ QL Series ~

Leading in Desktop SEM Imaging and Analysis

Stop Worrying About Interferences With These ICP-OES Solutions

Ion beam etch and deposition systems

Rapid screening of boron isotope ratios in nuclear shielding materials by LA-ICPMS a comparison of two different instrumental setups

Magellan XHR SEM. Discover the world of extreme high resolution scanning electron microscopy

ESCALAB 250: High Performance Imaging XPS

ETP ELECTRON MULTIPLIERS

taccor Optional features Overview Turn-key GHz femtosecond laser

Supplementary Information

System100Pro. Production tools for wafer processing. The Business of Science

The speed and quality you need for high volume scanning

Resonant Column (GDSRCA)

Laser 3 Plus - Process Oxygen

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

Park NX-Hivac The world s most accurate and easy to use high vacuum AFM for failure analysis.

Optical In-line Control of Web Coating Processes

By using patented polycapillary optics this diffractometer obviates the need for monochromators and collimators for linear projection of X-Rays.

Kit for building your own THz Time-Domain Spectrometer

An FT-ICR detection system for KATRIN

Diode Laser Systems In Gas Measurement

MR-i. Hyperspectral Imaging FT-Spectroradiometers Radiometric Accuracy for Infrared Signature Measurements

Advantages of a Novel Plasma Generator for the NexION 1000/2000 ICP-MS Systems

Performance Characterization Of A Simultaneous Positive and Negative Ion Detector For Mass Spectrometry Applications

Project by: Dr. Jorge A. Diaz. Physics School, University of Costa Rica, National Center for High Technology (CENAT)

ETP ELECTRON MULTIPLIERS

Development of Photon Detectors at UC Davis Daniel Ferenc Eckart Lorenz Alvin Laille Physics Department, University of California Davis

MR-i. Hyperspectral Imaging FT-Spectroradiometers Radiometric Accuracy for Infrared Signature Measurements

Tower Top Amplifier Systems Application Note

SCANNING ELECTRON MICROSCOPY AND X-RAY MICROANALYSIS

Meshing Challenges in Simulating the Induced Currents in Vacuum Phototriode

TriVista. Universal Raman Solution

Ensure reliable and repeatable multi-component gas analysis.

EndpointWorks. Plasma-Therm LLC

AccuTOF LC Training Course

Agilent 86146B Optical Spectrum Analyzer Technical Specifications

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

Material analysis by infrared mapping: A case study using a multilayer

Ionscope SICM. About Ionscope. Scanning Ion Conductance Microscopy. Ionscope A brand of Openiolabs Limited

FSI Machine Vision Training Programs

Compact Signal Calibrator

Transcription:

ICP-MS plasma 3 Multi-Collector ICP-MS www.nu-ins.com

plasma 3 is a third generation Multi Collector ICP Mass Spectrometer (MC-ICP-MS), designed to provide the best possible precision and accuracy for simultaneous isotopic ion detection. The instrument retains the unique, patented, variable dispersion Zoom lens enabling the simultaneous measurement of the isotopes of elements from lithium to the actinide series on its static collector array of sixteen Faraday detectors and up to six ion-counting detectors. Ground potential analyser operation provides ease of use and maintenance with excellent reliability. 02 While continuing to provide the highest precision, accuracy and flexibility that previous generations are renowned for, adds new refinements and innovations to maintain its position as the instrument of choice for Earth Sciences, Environmental Science, Nuclear Research, Archaeology, Forensics, Biochemistry and Biomedical Science.

plasma 3 Key Features Double focussing high precision isotopic measurement mass spectrometer Enhanced Sensitivity Interface as standard All new, innovative torch box design allowing easy connection of a wide range of sample introduction devices EATO Enhanced Abundance Transfer Optics (Patented) Robust third generation RF generator with Frequency Tuning Fully Dry Pumped configuration available Sixteen large dynamic range Faraday detectors, with optional software switchable resistor amplifiers Up to six ion-counting detectors (with SEM / Daly options) High abundance deceleration filters available for improved abundance sensitivity High resolution and pseudo high resolution capabilities Variable Zoom Optics allow for instantaneous switching between isotopic systems during analysis Fully compatible with third party accessories Low cost of ownership 03

Overview incorporates a double focussing forward geometry Nier Johnson analyser with an Electrostatic Analyser followed by a laminated magnet. The forward geometry is essential for simultaneous detection of multiple ion beams. Ions are focussed in both energy and direction. Variable Dispersion Zoom Optics utilises our unique field proven Zoom Optics system that removes the necessity for employing adjustable collectors. This provides a highly reliable collector array and allows instantaneous switching between collector configurations, and the use of full size discrete dynode SEMs or Daly detectors. The Zoom Optics system maintains double focussing conditions throughout the operational mass range. Faraday Collector System Sixteen Faraday detectors are fitted to the instrument as standard, giving the user the ultimate in flexibility for simultaneous measurement of all isotope systems. Vacuum System utilises the latest generation of vacuum pumps for ultimate performance and reliability, ranging from the large 80m 3 h -1 rotary vane pump for the plasma interface to the UHV turbo-molecular pumps on the analyser section. Failsafe mechanisms ensure vacuum integrity is preserved on power loss. also comes with the option of a fully dry pumped configuration. Analyser To maintain the ultra-high vacuum specification required for many applications, incorporates turbo molecular pumping of the analyser section. This results in the exceptional abundance sensitivity performance of the of <2ppm at -1 amu spacing relative to 238 U. Only by utilising such efficient pumps is it possible to ensure the abundance sensitivity doesn t degrade as sensitivity increases. is also available with the EATO (Enhanced Abundance Transfer Optics) option which further improves abundance sensitivity. The unique fixed Faraday collector array incorporates both electrostatic and magnet suppression devices to prevent the escape of ions and electrons from the Faraday detectors. comes with the option of switchable gain preamplifiers adding further flexibility to the collector. 04

All New ICP Source The ICP source has been designed and engineered to be robust while ensuring maximum stability and reliability during operation. This unique design of ICP source gives the user unrestricted access to the interface area to facilitate ease of use and maintenance. The third generation frequency tuning RF generator delivers rapid response to changing matrix conditions resulting in greater stability for even the most challenging applications. The source has been designed to simplify connection of the growing number of sample preparation systems required by the modern analyst with provision for Gas Chromatography (including heated transfer lines) Desolvation systems, Laser Ablation, and Cold Vapour generation among others. 05

Setting a New Standard in Collector Flexibility is the most technically advanced detector system ever designed for a MC-ICP-MS. Multiple ion counting devices, such as the full size SEM detectors that have been successfully deployed in Nu Instruments multi-collectors for two decades, can now be combined with multiple Daly Detectors and switchable resistor Faradays. Daly detectors Daly detectors offer the highest performance of any ion counting device over the largest dynamic range. By allowing the user to specify a collector configuration to meet all of their analytical requirements, now sets a new standard in flexibility. SEM detectors Up to six full size discrete dynode ion-counting multiplier channels can be interspersed within the plasma 3 collector array providing the flexibility and performance required for current and future applications. Simultaneous measurement of low level boron, U-Pb for geochronology studies and isotopic measurements of trace actinides for nuclear forensics are just a few applications. All of the multipliers used within the plasma 3 collector are of a full size, discrete dynode construction to ensure the best stability, linearity, lifetime and noise performance. Example of Daly linearity up to >5Mcps Software Switchable Resistor Faraday detectors Any number of Faraday preamplifiers can be fitted with two resistors of various sizes (10 10 Ω, 10 11 Ω, 10 12 Ω), allowing adjustment of the signal amplification of a given Faraday, which increases the dynamic range of the detector. This coupled with the largest MC-ICP-MS digital voltmeter range on the market, and up to six ion counters, demonstrates the unrivalled capability of for large dynamic range isotopic measurements. Multiple Daly detectors on a standard 06

Multiple Daly Detectors Multiple Daly detectors can be substituted for SEM detectors on. A full Daly collector system is available as standard for outstanding ion counting performance. This Includes up to six Daly Detectors in addition to the sixteen Faraday cups. 0.51350 Example of Daly/Daly stability: Nd143/Nd144 Ratio - 0.032% RSD over ~7 hours Nd143 signal of ~165Kcps Nd144 signal of ~320Kcps 0.51300 0.51250 0.51200 0.51150 0.51100 0.51050 0 50 100 150 200 250 300 350 400 time (mins) Daly/Daly stability over several hours Schematic of a Daly detector Image of the 07

Enhanced Abundance Transfer Optics (EATO) Due to the unique pumping system of, the analyser section routinely operates in the 10-9 mbar range which affords exceptional abundance sensitivity with standard optics, typically <2ppm pre-deceleration filter and <0.5ppm post-deceleration filter. For the more demanding actinide applications an additional lens element EATO (patent pending) has been designed which can be easily installed by users without the need to vent the analyser. This device is inserted in to the transfer chamber and provides significant improvement to the abundance sensitivity, typically <1ppm pre-filter and <0.05ppm post-filter. This improvement in abundance sensitivity performance is achieved without compromising transmission or mass bias stability. Deceleration Filter Off - 700ppb Deceleration Filter On - 30ppb Examples of abundance sensitivity measured at mass 237 in respect to 238 U using EATO with and without the use of a deceleration filter 08

High Mass Resolving Capability An interference free, flat-top peak is essential for precise and accurate isotopic measurements. The High Resolution features of achieve high mass resolving power across the entire multi-collector array. offers two types of high resolution capability: Pseudo High resolution and High resolution. Pseudo High Resolution The Pseudo High resolution method partially resolves peaks, leaving a flat-topped section of resolved peak for isotopic ratio measurements. This technique works as long as the interferences are all on the same side of the peak. High Resolution For applications where interferences appear on both low and high mass sides of the analyte, the high resolution method should be used. The unique design of the fixed collector system makes it possible to obtain full resolution from interferences by changing the collector slit widths, without having to replace collectors. This method allows the user to observe the complete resolution of interfering peaks from analyte peaks without reducing the sensitivity any further compared to Pseudo High resolution. Silicon isotopes partially resolved from their respective interferences in the Pseudo High resolution mode. Silicon isotopes fully separated from their respective interferences using the adjustable collecter masks. 09

Bespoke and Intuitive Software Suite comes with a software suite, which gives the user full control of the operation and configuration of the various components of the instrument. It features fully automated instrument control including start up, plasma ignition sequence and shut down. The user friendly interface provides relevant controls for tuning, diagnostics, and instrument protection. software analysis window Full integration with accessories such as auto samplers and laser ablation systems is also supported. The standard Nu Instruments Calculation Editor (NICE) software provides user-definable data reduction functions. Both raw and calculated data are available for each sample run along with full logging of instrument settings and operational parameters. Data can be analysed on-or off-line and can be easily exported for further analysis to third party software packages. Magnet scan window showing peak shapes of Neodymium isotopes in coincidence 10

Time Resolved Analysis The Time Resolved Analysis (TRA) feature was specifically developed for the analysis of transient signals resulting from coupled laser ablation systems, GC systems, hydride generators etc. Sequence Editor software incorporates a comprehensive and flexible integrated sequence editor enabling easy creation of automated sample analysis for unattended measurements in conjunction with an auto-sampler. Within the TRA, data can be acquired at customisable integration times and the generation of calculated results is made easy by the simple and flexible data selection capabilities of the utility. Creation of a new sequence is simple and rapid. Wash and blank measurement options can be fully customised for each sample and easily edited. Time Resolved Analysis window Automated Sequence Editor window Data can be subsequently exported for further offline analysis with popular third party data reduction software packages such as Glitter and Iolite or reanalysed in software. External hardware triggering is also available allowing data acquisition initiation or pausing within the single or multiple TRAs. Sequences can be fully edited at any time, even whilst running, allowing the analyst to prioritise samples and providing maximum flexibility without disruption to the on-going measurement. Furthermore, the automatic shutdown of the instrument on completion option is ideal for overnight runs. 11

plasma 3 Innovators in Mass Spectrometry Multi-Collector ICP-MS environmental planetary life science geochemistry material science nuclear Nu Instruments Limited Corporate Headquarters Unit 74, Clywedog Road South, Wrexham Industrial Estate, Wrexham, LL13 9XS - UK. Tel: +44 (0)1978 661304 nu.info@ametek.com Innovators in Mass Spectrometry. We deliver cutting-edge science and technology solutions, and offer our customers unparalleled support and maintenance service through the comprehensive Corporate Headquarters Nu Instruments UK Regional Contacts Nu Instruments Europe Nu Instruments Americas Nu Instruments Asia program. nu.sales@ametek.com europe-sales.nu@ametek.com americas-sales.nu@ametek.com asia-sales.nu@ametek.com visit us online: www.nu-ins.com version BRO11.6 All mentioned trademarks are registered by their respective owners.