Nanomechanical Mapping of a High Curvature Polymer Brush Grafted

Similar documents
Figure for the aim4np Report

Constant Frequency / Lock-In (AM-AFM) Constant Excitation (FM-AFM) Constant Amplitude (FM-AFM)

Outline: Introduction: What is SPM, history STM AFM Image treatment Advanced SPM techniques Applications in semiconductor research and industry

Mapping piezoelectric response in nanomaterials using a dedicated non-destructive scanning probe technique. Supporting Information

NanoMet Nanoparticle Diameter Example Report

Basic methods in imaging of micro and nano structures with atomic force microscopy (AFM)

Atomic Force Microscopy (Bruker MultiMode Nanoscope IIIA)

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

Distinguishing Between Mechanical and Electrostatic. Interaction in Single-Pass Multifrequency Electrostatic Force

Manufacturing Metrology Team

nanovea.com PROFILOMETERS 3D Non Contact Metrology

Bruker Optical Profilometer SOP Revision 2 01/04/16 Page 1 of 13. Bruker Optical Profilometer SOP

Electric polarization properties of single bacteria measured with electrostatic force microscopy

Standard Operating Procedure

Fast Optical Form Measurements of Rough Cylindrical and Conical Surfaces in Diesel Fuel Injection Components

Intermediate and Advanced Labs PHY3802L/PHY4822L

Spectral Line II: Calibration and Analysis. Spectral Bandpass: Bandpass Calibration (cont d) Bandpass Calibration. Bandpass Calibration

CTF Correction with IMOD

ANALYSIS OF ELECTRON CURRENT INSTABILITY IN E-BEAM WRITER. Jan BOK, Miroslav HORÁČEK, Stanislav KRÁL, Vladimír KOLAŘÍK, František MATĚJKA

Keysight Technologies Using Non-Contact AFM to Image Liquid Topographies. Application Note

SUPPLEMENTARY INFORMATION

Investigate in magnetic micro and nano structures by Magnetic Force Microscopy (MFM)

Scanning Tunneling Microscopy

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

CHARACTERIZATION AND FIRST APPLICATION OF A THIN-FILM ELECTRET UNSTEADY PRESSURE MEASUREMENT TECHNIQUE

Bruker Dimension Icon AFM Quick User s Guide

HybridStage - Automated, large sample-area mapping made easy

TRI-ALLIANCE FABRICATING Mertztown, PA Job #1

Imaging Carbon Nanotubes Magdalena Preciado López, David Zahora, Monica Plisch

Indentation Cantilevers

ScanArray Overview. Principle of Operation. Instrument Components

Bruker Dimension Icon AFM Quick User s Guide

Supporting Information. Atomic-scale Spectroscopy of Gated Monolayer MoS 2

Asphere and Freeform Measurement 101

Horizontal-Vertical (H-V) Bias

Stitching MetroPro Application

Prepare Sample 3.1. Place Sample in Stage. Replace Probe (optional) Align Laser 3.2. Probe Approach 3.3. Optimize Feedback 3.4. Scan Sample 3.

Online dressing of profile grinding wheels

University of MN, Minnesota Nano Center Standard Operating Procedure

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

ILLUMINATION AND IMAGE PROCESSING FOR REAL-TIME CONTROL OF DIRECTED ENERGY DEPOSITION ADDITIVE MANUFACTURING

The Impact of Very High Frequency Surface Reverberation on Coherent Acoustic Propagation and Modeling

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

Southern African Large Telescope. RSS CCD Geometry

Bringing Answers to the Surface

IMAGING P-N JUNCTIONS BY SCANNING NEAR-FIELD OPTICAL, ATOMIC FORCE AND ELECTRICAL CONTRAST MICROSCOPY. G. Tallarida Laboratorio MDM-INFM

CS 445 HW#2 Solutions

Copyright 2002 by the Society of Photo-Optical Instrumentation Engineers.

ATOMIC FORCE MICROSCOPY

Advanced Nanoscale Metrology with AFM

Optotop. 3D Topography. Roughness (Ra opt, Rq opt, and Rz opt) Height Distribution. Porosity Distribution. Effective Contact Area

A Study of Slanted-Edge MTF Stability and Repeatability

Basic Operator Procedure Training NewView 6300 GROWING IN A SHRINKING WORLD

PROCEEDINGS OF SPIE. Automated asphere centration testing with AspheroCheck UP

GAIN COMPARISON MEASUREMENTS IN SPHERICAL NEAR-FIELD SCANNING

Supplementary Information: Nanoscale. Structure, Dynamics, and Aging Behavior of. Metallic Glass Thin Films

Standard Operating Procedure of Atomic Force Microscope (Anasys afm+)

Spatial Filtering of Surface Profile Data

Keysight Technologies Why Magnification is Irrelevant in Modern Scanning Electron Microscopes. Application Note

Response spectrum Time history Power Spectral Density, PSD

8.2 IMAGE PROCESSING VERSUS IMAGE ANALYSIS Image processing: The collection of routines and

Lab 9: Operational amplifiers II (version 1.5)

OPTICAL BACKSCATTER REFLECTOMETER TM (Model OBR 5T-50)

Specifying and Measuring Nanometer Surface Properties. Alson E. Hatheway

ENVI.2030L Topographic Maps and Profiles

REAL TIME SURFACE DEFORMATIONS MONITORING DURING LASER PROCESSING

3.2 Measuring Frequency Response Of Low-Pass Filter :

Microscopic Structures

Application Information Advanced On-chip Linearization in the A1332 Angle Sensor IC

CHAPTER 2 POLARIZATION SPLITTER- ROTATOR BASED ON A DOUBLE- ETCHED DIRECTIONAL COUPLER

Scanning Tunneling Microscopy

SUPPORTING INFORMATION FOR

High-Resolution Bubble Printing of Quantum Dots

ADVANCED OPTICS LAB -ECEN 5606

Nanovie. Scanning Tunnelling Microscope

R I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS

Large Signal Displacement Measurement with an MTI Photonic Sensor Rev B

The NanomechPro Toolkit: Accurate Tools for Measuring Nanoscale Mechanical Properties for Diverse Materials

Supporting Information

ezafm OPERATING MANUAL

DEEP PENETRATING EDDY CURRENT for DETECTING VOIDS in COPPER

Antenna Measurement Software Features and Specifications

55:041 Electronic Circuits The University of Iowa Fall Exam 3. Question 1 Unless stated otherwise, each question below is 1 point.

Reference Manual SPECTRUM. Signal Processing for Experimental Chemistry Teaching and Research / University of Maryland

Your first NMR measurement

Use of the Shutter Blade Side A for UVIS Short Exposures

AFM of High-Profile Surfaces

EECS 216 Winter 2008 Lab 2: FM Detector Part I: Intro & Pre-lab Assignment

On spatial resolution

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

GEOMETRIC RECTIFICATION OF EUROPEAN HISTORICAL ARCHIVES OF LANDSAT 1-3 MSS IMAGERY

Supplementary Information

Contents Technical background II. RUMBA technical specifications III. Hardware connection IV. Set-up of the instrument Laboratory set-up

Proportional-Integral Controller Performance

LABORATORY 5 v3 OPERATIONAL AMPLIFIER

LION PRECISION. TechNote LT February, Capacitive Sensor Operation and Optimization

Remote Sensing 4113 Lab 08: Filtering and Principal Components Mar. 28, 2018

Depth of Focus, part 2

The spectral colours of nanometers

Lithography. Taking Sides to Optimize Wafer Surface Uniformity. Backside Inspection Applications In Lithography

Transcription:

Supplementary Information Nanomechanical Mapping of a High Curvature Polymer Brush Grafted from a Rigid Nanoparticle Gunnar Dunér 1, Esben Thormann 1, Andra Dėdinaitė 1,2, Per M. Claesson 1,2, Krzysztof Matyjaszewski 3, and Robert D. Tilton 4,5* 1 KTH Royal Institute of Technology, School of Chemical Science and Engineering, Department of Chemistry, Surface and Corrosion Science, Drottning Kristinas väg 51, SE-100 44 Stockholm, Sweden 2 YKI, Institute for Surface Chemistry, Box 5607, SE-114 86 Stockholm, Sweden 3 Department of Chemistry, 4 Department of Chemical Engineering, and 5 Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, U.S.A. 15213 *Telephone: 1-412-268-1159; Email: tilton@andrew.cmu.edu General Image Acquisition Settings The piezo was modulated at a frequency of 2 khz with an amplitude of 100 nm, that is force vs. separation data was collected every 0.5 ms. The aspect ratio in all images was 1:1 with the

images obtained by a tip scanning from right to left in the frame of the image, and bottom to top in Figs. 1-5, except in Fig. 4 where the tip direction was top to bottom. Figure Specific Acquisition Settings Figure 1 D-F Instrument Settings The scan size was 1.10 μm with a scan rate of 0.98 Hz, resulting in 2.00 cycles of force vs. separation data per pixel with a pixel resolution of 2.15 nm. The spring constant was calibrated to 1.12 Nm -1 using a deflection sensitivity of 12.85 nmv -1 found as the inverse of the slope of the hard wall interaction region in the force vs. distance data, calibrated against silica in water. A peak force setpoint of 5 nn was used. The Z-limit, which sets the maximum allowable voltage and thereby the resolution in the vertical direction, was set to its default value, yielding a typical digital height resolution of less than 1 Å. In the ScanAsyst software, the feedback gain was set to auto due to regions of both flat topography and high curvature. The deformation fit region was set to its default value 85%. Acquisition Conditions The images (512 512 pixels) were acquired in 1 mm NaCl solution with the ph of the injected solution set to 9.24 prior to measurement. An injection volume of 5 ml was used where the excess volume passed through an outlet to a waste container. Data Processing Recorded raw data were visualized in the NanoScope Analysis (v 1.20) software. Recorded data were subjected to subtraction of a first order polynomial fit in the horizontal direction

and centered around the mean in order to remove tilt. While removing tilt, asymmetric features can cause artefacts in the resulting image since the asymmetric features affect the baseline and thereby the resulting fit. A cutoff was used in order to remove these effects while maintaining a proper fit to the baseline data. The cutoff, ignoring data above, in baseline fitting was for Fig. 1D (Height) 5%, Fig. 1E (Deformation) 5% and Fig. 1F (Dissipation) 15%. The resulting data after subtraction of the best polynomial fit were exported in ASCII format and imported in MATLAB to produce gray scale coded images. The display range for Figure 1D (Height) is 0 to 25 nm (data range: -3.5 to 34.4 nm). The display range for Figure 1E (Deformation) was adjusted to 2.7 to 15 nm from the full data range (2.7 nm to 44.2 nm) due to a single spot outlier. The display range for Figure 1E (Dissipation) was, in units of ev, 147 to 600 ev (data range: 147 to 1056 ev) converted to units of kt using k= 8.617 10 5 ev K -1 and T=295 K. Figure 2 Instrument Settings The scan size was 321 nm with a scan rate of 0.98 Hz, resulting in 2.00 cycles of force vs. separation data per pixel with a pixel resolution of 0.63 nm. The spring constant was calibrated to 0.88 Nm -1 using a deflection sensitivity of 13.86 nmv -1. The setpoint forces were 2, 7, 10, and 2 nn. The Z-limit was set to its default value, yielding a typical digital height resolution of less than 1 Å. In the ScanAsyst software, the feedback gain was set to auto due to regions of both flat topography and high curvature. The deformation fit region was set to its default value 85%.

Acquisition Conditions The images (512 512 pixels) were acquired in 1 mm NaCl solution with the ph of the injected solution set to 9.24 prior to measurement. An injection volume of 5 ml was used where the excess volume passed an outlet to a waste container. Data Processing Recorded raw data were visualized in the NanoScope Analysis (v 1.20) software and the data was exported in ASCII format and further treated in MATLAB. Recorded data were subjected to subtraction of a first order polynomial fit in the horizontal direction and centered around the mean in order to remove tilt. The cutoff, ignoring data above, in baseline fitting is summarized in Table S1 below: Table S1. Cut off values used for baseline fitting of first order polynomials to remove tilt. Cutoff 2 nn 7 nn 10 nn 2 nn back Height 0.1 0.1 0.1 0.1 Deformation 0.2 0.2 0.2 0.3 Adhesion 0.57 0.5 0.5 0.5 Dissipation 0.5 0.32 0.3 0.55 In the ScanAsyst software, the feedback gain was set to auto due to regions of both flat topography and high curvature. The deformation fit region was set to its default value 85%.

Figure 4 Instrument Settings The scan size was 150 nm with a scan rate of 0.98 Hz, resulting in 2.00 cycles of force vs. separation data per pixel with a pixel resolution of 0.29 nm. The spring constant was calibrated to 1.12 Nm -1 using a deflection sensitivity of 12.85 nmv -1. The setpoint force was 6 nn. The Z-limit was set to its default value, yielding a typical digital height resolution of less than 1 Å. In the ScanAsyst software, the feedback gain was set to auto due to regions of both flat topography and high curvature. The deformation fit region was set to its default value 85%. Acquisition Conditions The images (512 512 pixels) were acquired in 1 mm NaCl solution with the ph of the injected solution set to 6.1 prior to measurement. An injection volume of 5 ml was used where the excess volume passed through an outlet to a waste container. Data Processing Recorded raw data were visualized in the NanoScope Analysis (v 1.20) software and the data was exported in ASCII format and further treated in MATLAB. Recorded data were subjected to subtraction of a first order polynomial fit in the horizontal direction and centered around the mean in order to remove tilt. The cutoff, ignoring data above for the fitting, was for height 5%, deformation 20%, adhesion 20% and dissipation 34%. The display range in the left panel corresponds to the full data range and is for height -1.2 to 16.1 nm, deformation 3.0 to 8.7 nm, adhesion 0.0 to 1.1 nn and dissipation -20 to 153 ev, converted to units of kt using k= 8.617 10 5 ev K -1 and T=295 K.

Figure 5 Instrument Settings The scan size was 153.1 nm with a scan rate of 0.98 Hz resulting in 2.00 cycles of force vs. separation data per pixel with a pixel resolution of 0.30 nm. The spring constant was calibrated to 0.55 Nm -1 using a deflection sensitivity of 19.92 nmv -1. The setpoint force was 6 nn. The Z-limit was set to its default value, yielding a typical digital height resolution of less than 1 Å. In the ScanAsyst software, the feedback gain was set to auto due to regions of both flat topography and high curvature. The deformation fit region was set to its default value 85%. Acquisition Conditions The images (512 512 pixels) were acquired in 1 mm NaCl solution with the ph of the injected solution set to 9.2 prior to measurement. An injection volume of 5 ml was used where the excess volume passed through an outlet to a waste container. Data Processing Recorded raw data were visualized in the NanoScope Analysis (v 1.20) software and the data was exported in ASCII format and further treated in MATLAB. Recorded data were subjected to subtraction of a first order polynomial fit in the horizontal direction and centered around the mean in order to remove tilt. The cut off, ignoring data above for the fitting, was for height 10%, deformation 20%, adhesion 20% and dissipation 40%. The display range in the left panel corresponds to the full data range and is for height -1.0 to 20.4 nm, deformation 0.8 to 10.7 nm, adhesion -0.1 to 0.8 nn and dissipation 12 to 339 ev, converted to units of kt using k= 8.617 10 5 ev K -1 and T=295 K.

Figure 6 Instrument Settings The scan size was 150 nm with a scan rate of 0.50 Hz, resulting in 3.90 cycles of force vs. separation data per pixel with a pixel resolution of 0.29 nm. The spring constant was calibrated to 0.88 Nm -1 using a deflection sensitivity of 13.86 nmv -1. A setpoint force of 2 nn was used. The Z-limit was 2.0 μm, yielding a typical digital height resolution of less than 0.4 Å. In the ScanAsyst software, the feedback gain was manually adjusted to 9 since the scanned area was dominated by high curvature. This value resulted in low force error without increasing the noise in the force error signal. The deformation fit region was set to its default value 85%. Force vs. separation data was saved using the High Speed Data Capture (HSDC) command which enables the user to save raw data in the form of force vs. separation. The deflection error and the height were captured at a rate of 500 khz during 2996 ms at Y-line position 183 (of 512). Acquisition Conditions The data was acquired in 1 mm NaCl solution with the ph of the injected solution set to 9.24 prior to measurement. An injection volume of 5 ml was used where the excess volume passed through an outlet to a waste container. Data Processing Force vs. separation data was visualized using the NanoScope Analysis (v. 1.20) software and the data was exported in ASCII format. Force vs. separation was plotted directly in MATLAB as a function of the position of the nanoparticle center on approach (top left) and retraction (top right) as an average of 8 cycles (4+4 for scan direction left-to-right and rightto-left respectively). Force vs. separation data (A and B) were visualized from 0 to 20 nm separation using interpolated shading, color map gray, axis option vis3d and -38 and 30

degrees horizontal rotation and vertical elevation respectively. Superimposed contour lines show the force at 250, 750, 1250 and 1750 pn respectively. Force vs. separation data (C) were selected from the particle edge and center. A zero-force baseline was introduced as a guide to the eye. Force Error Analysis The error in the force may affect the nanomechanical properties and thus the force error images were examined. In this case, the error for the data in Fig. 2 with a 2 nn peak force setpoint is: 65±54 pn (3%) at the edge and 40±30 pn (2%) at the center; with a 7 nn peak force setpoint: 102±99 pn (1%) at the edge and 38±7 pn (<1%) at the center; with a 10 nn peak force setpoint: 122±120 pn (1%) at the edge and 16±8 pn (<1%) at the center; for the return to a 2 nn peak force setpoint: 69±51 pn (3%) at the edge and 30±7 pn (2%) at the center. In Fig. 4, the error is 162±119 pn (3%) at the edge and 73±54 pn (1%) at the center, and in Fig. 5 it is 137±105 pn (2%) at the edge and 28±18 pn (<1%) at the center. Tip imaging The tip qualification procedure in the NanoscopeAnalysis Software (v. 1.20) from Bruker was used to create a tip image using a titanium roughness sample containing sharp edges (model number RS-15M, Bruker). The roughness sample was imaged over an area of 1 1 μm to produce a height image of 512x512 pixels. Local maxima within the height image were searched to produce local peaks within 10x10 nm sub-squares (see Figure S1, left). The slopes of all the peaks were calculated and the steepest slope in any direction constituted the slope in the tip-image (see Fig. S1, right) since no slope can be steeper than that of the tip.

Figure S1. Left: Height image from a 1 1 μm scan showing local maxima used to determine the tip shape. Right: resulting tip shape. Tip Asymmetry Effect on Property Mapping: Image Asymmetry. We note in the main paper that although each deformation, adhesion and dissipation map displayed in Figs.1, 4 and 5 showed a local minimum in the centre surrounded by a maximum at a horizontal position further out, the images do not all appear symmetrical. We consider first whether image asymmetry is an artifact of the variation of peak force setpoint error relative to the scan direction (see Fig. 1C). Most notably, the peak force was overshot as the tip first approached the particle from the bare surface, as the feedback control system could not perfectly maintain the applied peak force at a constant value. The feedback correction restored the peak force to the setpoint as the tip scanned across the particle, but then a somewhat too low peak force was applied as the tip then moved away from the particle centre as the feedback control imperfectly adapts to the changing force profiles. The maximum error amounted to only 3% of the peak force setpoint. Thus, there could be systematic error in the magnitudes of the properties reported on different sides of the nanoparticles, but the variation in the reported properties from the particle centre to the extremities are larger than can be attributed to this small systematic error in applied load.

From the data in Fig. 6A, where the force vs. separation curves are plotted for all horizontal positions, we can estimate the maximum error in the deformation for a single force curve based on a given peak force setpoint error. A 3% peak force setpoint error near the edges (shown by the ridges in the three-dimensional force curve representation) would cause an error of 0.13 nm or 2.7% error in deformation. For the largest error in peak force recorded in any individual measurement, 10.4%, the resulting deviation in height would be 0.31 nm or 1.8%. Note that the error in height approaches zero as hard-wall contact is approached, meaning for higher forces, the difference in height would be even less. Given the small error in deformation and height, it is unlikely that the adhesion or the dissipation will suffer significantly larger error. Asymmetry is not likely due to peak force error, nor is it likely to be an effect of the scanning angle, since the tip will always have the same geometry relative to the surface. Next, we consider whether the image asymmetry is an artifact of the tip-shape. In Fig. S2 the deformation is shown as a line scan over the nanoparticle at ph 9.2 at peak forces of 2 nn, 7 nn, 10 nn and 2 nn as a repeat measurement. There is a trend of higher deformation on the left side of the nanoparticle. We propose that this is due to a relatively higher contact area on the left side of the tip (see Fig. S1), as a result of the tilt of the tip as mounted in the probe holder. The difference in the maximum deformation between each side increases with peak force. The asymmetry in the tip-shape, which most likely is caused by a finite tilt-angle of the mounted cantilever in the probe holder, shows a steeper slope to the left side of the tip apex compared to the right side. The increased deformation on the left side in the raw data could be explained by the relatively smaller contact area made between the right side of the tip and the left side of the particle as the tip moves away from the particle during a scan. Higher deformation on the left-hand side of the nanoparticle is also present in Fig. 4 and Fig. 5. In

these cases, different tips were used but the same behavior is repeated. Thus, this further corroborates the idea that the deformation asymmetry is caused by the mounting tilt-angle. Inspection of adhesion or dissipation raw data used to produce the property maps does not reveal any pronounced asymmetry in the data. Therefore, it is plausible to propose that data asymmetry mainly relates to deformation and is an effect of the tip-tilt angle. Figure S2. Deformation raw data and corresponding section profiles at a peak force of 2 nn (A), 7 nn (B), 10 nn (C) and 2 nn repeat (D).

In Fig. S3, force vs. separation data are shown as a function of the horizontal distance to the nanoparticle centre on approach of the tip to the sample. From the isodynamic curves in the top view, it is seen that the range of the steric force is longer on the left side of the nanoparticle than on the right side, consistent with greater deformation on the left. Figure S3. Force vs. separation curves plotted as a function of the horizontal distance to the nanoparticle centre on approach of the tip to the sample. Isodynamic curves show where the force was 0.3 nn, 0.8 nn, 1.3 nn and 1.8 nn respectively. A peak force of 2 nn was used and the data was recorded at ph 9.2 in 1 mm NaCl at 23 C.