instructions Version 6.0

Similar documents
K15.13 FACE FIXED DOOR HINGES K15 DOORS

Door Hinges Drill-in Hinges

WASHING MACHINE AND WASHER-DRIER

Profiform 200 Profiform 320. Operating manual

Wall mounting with holding profile

Installation instructions AZ120 (Anchor foot with placement hinge, to be embedded: type Albatros)

Operating Manual Multi-Spot M22AL CD Stud Welding Machine

Mounting instructions SZ210 Full-frame pedestal with screw-on tube with placement hinge, for type SCHATTELLO

Instruction manual for STA 1 sectional door operator

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02

Aluminum Sprinter Rack Installation

K15.12 ROLLENBAND K15 DOORS

Open Up Your View With CABLE SYSTEMS

Changer CDC A01. Operating and Installation Instructions.

Universal flat-panel mount

Assembly Instructions for model: VMPR1

OPERATING INSTRUCTIONS 5-AXIS CLAMPING SYSTEM + ACCESSORIES

- 4 - Fig. 3b. Fig. 1b. Fig. 2. Fig. 2b MT 300

Single and Double Gates Operation & Maintenance Manual

Merloni Elettrodomestici. Technical Fitting Manual FRIDGE. Language Issue/Edition Page GB /

ENG. Installation instruction. Thermalift 42 TOF, TOR K085129

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Precipitation Monitor ,

for HACA stationary fixed two rail ladders with / without safety cage

Knife grinding machine K3 H/K

...thoroughly tried and tested!

INSTALLATION MANUAL PBL-UMP

Electrical height adjustment. ... easy & reliable. Multilift II telescope Multilift II. Synchron

Wind Transmitter compact xx

Instruction manual for STA 1 sectional door operator

Technical information

Piazzola Pergola Awning Manufacturing and installation guide

Page 1 of 6 Systems Inc.

Tree protection systems 2.0

C10. Data sheet. Force transducer. Special features. B de

INSTALLATION MANUAL PBC-UMS

Wind Transmitter - compact

6.1. PUSH-PULL-PROPS and accessories

PUSH-PULL-PROPS. and accessories ROBUSTA-GAUKEL GMBH MOUNTING TECHNOLOGY &CO.KG

Intex Engineered Pergola System Installation Instructions. NOTE: See Appendix for Foundation Requirements

Roof fastener. Perfectly thought out for every roof

Installation Guide Simplicity Alfresco. V1.9 Lu070318

Z07- SWING GATE HOME AUTOMATION. zero Z07 - SWING GATE MOTOR SUPPLY V HOME AUTOMATION IT EN FR Z07.REV USER MANUAL AND CONFIGURATION PG1

BL-ER-P Ethernet Radio Unit for Pedestal Installation Guide

Assembly instructions Pantograph shutters

THE INSTALLING INSTRUCTION FOR CONCEALED TANK

Capacitive level meters CLM 40 INSTRUCTIONS MANUAL. průmyslová elektronika

Heavy duty profiles. Heavy loads with maximum stability. Profile general overview... p Heavy duty profiles... S Load data... p.

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7

Digital Electronic Thermostat With RF

HP 2 SERIES Integral Driver - Solid State LED

Coin control unit. Operating instructions C 4065

Q U I C K R E F E R A N C E G U I D E. Tel: Fax:

On-roof system Alpha + Product catalogue

Operating Instructions for Flow Indicator. Model: DAZ

Clearview Railing System Installation Instructions

N35 ALUMINIUM ROLL-UP DOOR INSTALLATION MANUAL

MODEL 2EA/2EB DOOR INSTALLATION INSTUCTIONS

TABLE OF CONTENTS. Impregnated... 1 NORDIC FENCE Fynbo FSC Certified... 1

Operating Manual. for CUTTING, PERFORATING, BENDING SLB120

Sport-Thieme Handball Goal, 3x2 m, Free-Standing or socketed

H2-50 Hydrogen Generator Field Update

SMALL GAUGE NIBBLER ASSEMBLY & OPERATING INSTRUCTIONS Mission Oaks Blvd., Camarillo, CA Visit our Web Site at

XT Technical Documentation. The magnetostrictive level sensor. Edition: Version: 1 Article no.:

Clamping devices 521

Mounting systems for solar technology

MOUNTING INSTRUCTIONS CONCRETE PURLIN BRACKET

Midmark Stainless Steel Cages Setup Manual

Precipition Sensor with analogue Intensity Output ,

Antenna Splitter ASA 1. Instruction manual

Cable Railing Kit Application Guide

INSTALLATION INSTRUCTIONS TRI-ROOF. energy for a better world

Wind Transmitter - with analogue output xxx

Articulating TV/Monitor Wall Mount Model: WA300S (Butterfly Series)

Bracket guide. LK Pipe Pole. LK Radiator fixture Uni

K11.11 ORCA K11 DOORS

Installation Guide Contemporary Alfresco V1.3 LU

Single Sided Height Adjustable Benching

Instruction manual ADN-W AM. Antenna Module

Type A - Clamping force axially applied to the clamping edge. Extending and simultaneous lowering/clamping

INTEX Millwork Solutions SECTION EXTERIOR PVC PERGOLAS (IBC Compliant)

+ A Phoenix Mecano Company. RK DuoLine 160. Degree of protection IP 40. the new industry benchmark

ABM International, Inc.

These Installation Instructions are valid for antennas in the following version:

Operating Instructions K-POWERgrip EWL Always on the safe site.

Operating Instructions for Microwave Level Switch. Model: LNM

Single and Double Gates Operation & Maintenance Manual

HowtoPlans..org. 6'x8' Storage Shed Plan

PV-ezRack PostMount 1-A Installation Guide

European Technical Approval ETA-10/0413

Sliding Door Enclosure. Telephone Cleaning. Please retain this manual after installation for future reference and maintenance.

EURO-BEARINGS LTD COMBINED ROLLER BEARINGS & MATING STEEL PROFILES

D25122(K) D25123(K) D25124(K) D25213(K)

XY-Stages series 5102

Assembly & Installation Instructions

MPA-9000 Universal Ceiling Projector Mount Kit

TREX POST MOUNT DECKING AND CONCRETE

PHTM100 - Phantom 100 Flat Screen Wall Mount with Wafer Thin Projection Fits Screens up to 25 lbs with 100mm or 75mm Mounting Patterns

Installation guide square

6000 Horizontal Router Table Owners Manual Please Read Carefully!

Transcription:

instructions Version 6.0 D Montage Edelstahl-Standsäulen Seite...3 GB Installation Stainless Steel Vertical Column Page... 19 FR Notice de montage des colonnes en acier inox Page...35

GB GB Contact Important Information You have chosen a high-quality, weatherproof and long-lasting stainless steel product made by Behnke! To ensure the durability of your stainless steel device, please adhere to the following care instructions: Clean the stainless steel surface regularly to maintain its shiny appearance. Use cleansing agents intended for stainless steel surfaces and follow the manufacturer s application guidelines. In case rust marks become visible despite regular cleaning, these rust marks stem from flash rust. These particles (carried by air) can easily be removed with an appropriate cleansing agent. Please note that Behnke intercoms and accessories may only be installed and serviced by qualified electricians in compliance with all relevant safety provisions. Before carrying out service and maintenance work, please ensure that the devices are safely disconnected from the power grid (unplug power supply unit) and are disconnected from any other network. For further legal information, please see page 32. contact Information For detailed information on our product, projects and services: Tel.: +49 (0) 68 41/81 77-700 24-hour-service Do you need help? Feel free to contact us 24/7. We will be happy to assist you with any technical questions you may have and we will also help you getting set-up. Tel.: +49 (0) 68 41/81 77-777 Telecom Behnke GmbH Gewerbepark An der Autobahn Robert-Jungk-Str. 3 66459 Kirkel Internet and e-mail-address info@behnke-online.de www.behnke-online.de 18 www.behnke-online.com

Contents GB Contents 1. Basis sketch 20 1.1. Basis for Behnke Vertical Columns...20 2. Assembling the Vertical Column 22 3. Assembly Instructions 23 3.1. Fixing the column mount and assembling column body and stand...23 3.2. Column with one Behnke door intercom...24 3.3. Column with two Behnke door intercoms...25 4. Illumination module 20-6011/21-6011 26 5. Dimensions 27 5.1. Column Flex...27 5.2. Column Hex...28 5.3. Column Hex + rain shield...29 5.4. Column Square...30 5.5. Pillar Exclusive... 31 6. Information 32 www.behnke-online.com 19

GB GB Basis sketch 1. Basis sketch 1.1. Basis for Behnke Vertical Columns 2 1 70 cm 3 4 70 cm Hy My Dimensions Length: by = 70 cm Width: bz = 70 cm Depth: d = 80 cm Pillar connection: cy/cx = 22 / 30 cm Covered square: 1-4 Ah = 0.00 m Water level from top ground surface: Common Water level = 99.00 m Specific soil weight = 18.00 kn/m³ Specific soil weight (water) = 8.00 kn/m³ Angle of base friction: D = 25.00 Angle of repose: phi = 25.00 Cohesion: c = 0.00 kn/m² 20 www.behnke-online.com

Basis sketch GB Load (case 1) Thrust: ey/ez = 0.00 / 0.00 Nst = 2.00 kn (load on basis axle) Momenta: My/Mz = 1.70 / 0.00 knm Momenta according to approximation theory: M2y/M2z = 1.70 / 0.00 knm Horizontal force: Hy/Hz = 1.00 / 0.00 kn Resolut. momenta: My/Mz = 1.70 / -0.80 knm Resulting forces: F = 10.45 kn Acceptable eccentricity: Divisor e = 3.00 Stress resultants (case 1) Eccentricity approximation: eyii/ezii: -0.077 / 0.163m Eccentricity confirmation (from total load): eyii/by)^2+(ezii/bz)^2 = 0.008 = (1/e)^2 = 0.11 According to DIN 1054 Alternate breakline: by /bz = 0.497 / 0.325 m Present soil pressure: sigma = 64.78 kn/m² Acceptable soil pressure: 300.00 kn/m² Dimensions (concrete C12/15) Basis without reinforcement according to DIN 1045 table 17 Load expansion: D recorded/available = 21.5/80.0 cm www.behnke-online.com 21

GB GB Assembling the Vertical Column 2. Assembling the Vertical Column Clamping plate 1 (firmly integrated) Behnke door intercom, 120 mm broad (e.g. Series 20) Air vents Front frame Cover panels set 1: Clamping plate 2 Support sheet for door intercom devices, modules and cover panels Cover panel with cham fered top Fixing sheet to attach a tapping box Base plate with cover (fixed with stud bolts) Clamping plate 3 Cover panel without chamfering to be shortened if necessary, lower edge not visible Cable inlet from below through the column s base 22 www.behnke-online.com

Assembly Instructions GB 3. Assembly Instructions 3.1. Fixing the column mount and assembling column body and stand Fix the column mount to the concrete basis e.g. by using hex screws and plugs, stud bolts or stay bolts. Please note: These parts are not included in the box. Put the column s base cover on the column s base. Please note that you cannot insert the column s base cover at a later stage due to the air vents in the column body. Then put the column body through the column s base cover and fix the column body to the basis. Insert the door intercom and the cover panel(s) and fix with clamping plates. Use the angle plate to fix the lowest cover panel. Then move down the column s base cover. www.behnke-online.com 23

GB GB Assembly Instructions 3.2. Column with one Behnke door intercom Height 1.75 m for pedestrians (for example) 1 Fix the door intercom or the module in question to the column. To do so, please use the screws provided in the box. Use a clamping plate to fix the door intercom s lower end. Pedestrians 1 W Speaker 21-1100 Professional camera (illuminated) 21-2903 Call button, label 21-2011 2 Then fix the cover panel marked starting Microphone 21-3100 plate so that the straight cut edge points towards the end of the column. The chamfered edge points towards the Behnke door intercom device or module frame. Use a second clamping plate to fix the lower edge of the cover panel. Cover panels set 1 21-5334 3 Use the cover panel marked closing panel to close the remainder of the column. In case the cover panel is too long, please shorten it accordingly. Please note that the distance to the column s base must not be greater than 5 mm. 4 When fixing the closing cover, please make sure that the two drilled holes point up. The lower edge will be fixed to the column s base with an angle plate (cf. page 23). 2 2 15 V power supply unit 20-9585 for camera and basic electronics telephone connection coax cable for camera / video feed or screened and twisted two wire cable 24 www.behnke-online.com

Assembly Instructions GB 3.3. Column with two Behnke door intercoms Height 2.20 m for lorries and cars (for example) 1 + 3 Fix the door intercom or the module in question to the column. To do so, please use the screws provided in the box. Use a clamping plate to fix the door intercom s lower end. 2 Fix the cover panel marked intermediate cover below the door intercom s frame with a clamping plate. Amplifier 7 W 20-0054 Lorries Module with broad band speakers 21-6102 Professional camera (illuminated) 21-2903 Call button, label 21-2011 Microphone 21-3100 4 Then fix the cover panel marked starting plate so that the straight cut edge points towards the end of the column. The chamfered edge points towards the Behnke door intercom device or module frame. Use a second clamping plate to fix the lower edge of the cover panel. 1 W Cars BT 21-111 door intercom size 3 with a large speaker, call button, label and microphone 5 Use the cover panel marked closing panel to close the remainder of the column. In case the cover panel is too long, please shorten it accordingly. Please note that the distance to the column s base must not be greater than 5 mm. Cover panels set 3 21-5336 6 When fixing the closing cover, please make sure that the two drilled holes point up. The lower edge will be fixed to the column s base with an angle plate (cf. page 23). telephone connection 4 15 V power supply unit 20-9585 for camera and basic electronics 4 telephone connection 15 V power supply unit 20-9585 for camera and basic electronics coax cable for camera / video feed or screened and twisted two wire cable www.behnke-online.com 25

GB GB Illumination module 20-6011/21-6011 4. Illumination module 20-6011/21-6011 120 60 10 10 Clamp 12-15 V + 12-15 V Tension 12-15 V + 12-15 V Please provide a stabilised 12-15 Volts direct current power supply. The power drain amounts to approx. 120 ma 26 www.behnke-online.com

Dimensions GB 5. Dimensions 5.1. Column Flex Column base 157,5 235,5 117,75 48 48 Back cover Extrusion profile Behnke door intercom Cable entry Ø 40 mm Screw hole M4 266 315 Column body 100 120 300 max. 1750 (variable height) www.behnke-online.com 27

GB GB Dimensions 5.2. Column Hex Column base 135 252 427,57 Column body 1350/ 1750 374 185 86 86 Screw M6 (to fix the column cover) Locknut Ø 12 mm Threaded bolt M8 x 15 (to fix the column body) Cable entry Ø 60 mm Column base cover Cover Angle plate with slot hole Base 180 120 210 28 www.behnke-online.com

Dimensions GB 5.3. Column Hex + rain shield Column base 135 252 427,57 Column body 1350/1750/2200 374 185 86 86 Screw M6 (to fix the column cover) Locknut Ø 12 mm Threaded bolt M8 x 15 (to fix the column body) Cable entry Ø 60 mm Column base cover Cover Angle plate with slot hole Base 180 120 210 www.behnke-online.com 29

GB GB Dimensions 5.4. Column Square Column base 150 Screw M6 (to fix the column cover) Locknut 225 110 Column body 147 85 Ø 12 mm Threaded bolt M8 x 15 (to fix the column body) Cable entry Ø 60 mm Column base cover Cover Angle plate with slot hole 250 Base 197 1350/1750 85 305 30 www.behnke-online.com

Dimensions GB 5.5. Pillar Exclusive Column base 3 110 11 5.5 70 1750 54.5 109 Ø 30 80 Column body 117 170 6 www.behnke-online.com 31

GB GB Information 6. Information 1. We reserve the right to change our products, without notice, for technical progress. As a result of continuous development, the products illustrated may look different from the products actually delivered. 2. Reprints of texts, images or pictures or copies from these instructions in any media given in full or as extracts require our express written consent. 3. Design and layout of these instructions are copyright protected. We do not assume any liability for possible errors, contents errors and misprints (including technical data or within images and technical diagrams). Information with regard to product liability: 1. All products mentioned in these instructions may only be used for the purpose intended. In case of doubts, please contact a competent specialist or our services department (cf. telephone numbers). 2. Products with a power supply (especially those plugged in to 230 V) must be unplugged before opening or during installation. 3. Damage and consequential damage resulting from altering or meddling with our products or their improper use are excluded from product liability. This also applies to improper storage or external influences. 4. The respective guidelines for working on power supplies with 230 V or batteries equally apply to working with our products, e.g. directives regarding electromagnetic compatibility or the Low Voltage Directive. Please leave corresponding work to trained specialists familiar with the matter. Electromagnetic Compatibility Low Voltage Directive 5. Our products meet all technical guidelines and telecommunications regulations currently applicable in Germany and the EU. All our products meet the standards for CE certification valid in the entire EU: Electromagnetic Compatibility according to directive 2004/108/EC and Low Voltage Directive 73/23/EEC modified by 93/68/EEC. 32 www.behnke-online.com

Notizen / Note www.behnke-online.de 49

Notizen / Note 50 www.behnke-online.de

Notizen / Note www.behnke-online.de 51

Version 6.0 Kirkel, Mai 2014 TCB 0959_0810 TELECOM BEHNKE GMBH Telecom Behnke GmbH Gewerbepark An der Autobahn Robert-Jungk-Straße 3 66459 Kirkel Germany Info-Hotline: +49 (0) 68 41 / 81 77-700 Service-Hotline: +49 (0) 68 41 / 81 77-777 Telefax: +49 (0) 68 41 / 81 77-750 info@behnke-online.de www.behnke-online.de