Spectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

Similar documents
Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

Basic Components of Spectroscopic. Instrumentation

SCCH 4: 211: 2015 SCCH

The equipment used share any common features regardless of the! being measured. Electronic detection was not always available.

CHAPTER 7. Components of Optical Instruments

Chemistry Instrumental Analysis Lecture 7. Chem 4631

Components of Optical Instruments. Chapter 7_III UV, Visible and IR Instruments

Components of Optical Instruments

University of Wisconsin Chemistry 524 Spectroscopic Components *

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

AP Chemistry Cell Phone Spectroscopy Lab Adopted from Alexander Scheeline Department of Chemistry University of Illinois at Urbana-Champaign

Chemistry Instrumental Analysis Lecture 10. Chem 4631

Modern Instrumental Methods of Analysis Prof. Dr. J.R. Mudakavi Department of Chemical Engineering Indian Institute of Science, Bangalore

Observational Astronomy

THROUGHPUT OF AN OPTICAL INSTRUMENT CHEM 314

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

Ultraviolet Visible Infrared Instrumentation

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

Guide to SPEX Optical Spectrometer

Components of Optical Instruments 1

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

ABC Math Student Copy. N. May ABC Math Student Copy. Physics Week 13(Sem. 2) Name. Light Chapter Summary Cont d 2

Period 3 Solutions: Electromagnetic Waves Radiant Energy II

Section 1: SPECTRAL PRODUCTS

Measuring optical filters

Components of Optical Instruments

Skoog Chapter 1 Introduction

Operating Manual. Model 721N. Visible Spectrophotometer

LlIGHT REVIEW PART 2 DOWNLOAD, PRINT and submit for 100 points

Scintillation Counters

Electromagnetic Waves

USB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system

Chapter 36: diffraction

USER MANUAL FOR VISIBLE SPECTROPHOTOMETER

The Photoelectric Effect

Experiment 2B Integrated Laboratory Experiment DETERMINATION OF RIBOFLAVIN: A COMPARISON OF TECHNIQUES PART B. MOLECULAR FLUORESCENCE SPECTROSCOPY

Form 4: Integrated Science Notes TOPIC NATURAL AND ARTIFICIAL LIGHTING

A Software Implementation of Data Acquisition Control and Management for Czerny Turner Monochromator

Spectroscopy Lab 2. Reading Your text books. Look under spectra, spectrometer, diffraction.

Chapter 18: Fiber Optic and Laser Technology

Improved Spectra with a Schmidt-Czerny-Turner Spectrograph

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Light, Lasers, and Holograms Teleclass Webinar!

Radiation detectors Photographic detection

A progressive wave of frequency 150 Hz travels along a stretched string at a speed of 30 m s 1.

Chapter 17: Wave Optics. What is Light? The Models of Light 1/11/13

Infrared Detectors an overview

(A) 2f (B) 2 f (C) f ( D) 2 (E) 2

6 Experiment II: Law of Reflection

Measurement Method of High Absorbance (Low Transmittance) Samples by UH4150 INTRODUCTION

Absentee layer. A layer of dielectric material, transparent in the transmission region of

1/8 m GRATING MONOCHROMATOR

NIR SPECTROSCOPY Instruments

Conceptual Physics Fundamentals

UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells

combustion diagnostics

PhysicsAndMathsTutor.com 1

OPAC 202 Optical Design and Instrumentation. Topic 3 Review Of Geometrical and Wave Optics. Department of

Test 1: Example #2. Paul Avery PHY 3400 Feb. 15, Note: * indicates the correct answer.

Chapter 25. Optical Instruments

Educational Spectrophotometer Accessory Kit and System OS-8537 and OS-8539

AP Physics Problems -- Waves and Light

Physics 1C. Lecture 24A. Finish Chapter 27: X-ray diffraction Start Chapter 24: EM waves. Average Quiz score = 6.8 out of 10.

EE119 Introduction to Optical Engineering Spring 2002 Final Exam. Name:

Light, Lasers, and Holograms Teleclass Webinar!

Physics 308 Laboratory Experiment F: Grating Spectrometer

Doppler-Free Spetroscopy of Rubidium

Energy in Photons. Light, Energy, and Electron Structure

Chapter Ray and Wave Optics

High Performance Thin Film Optical Coatings Technical Reference Document 09/13. Coatings Capabilities. Heat Control - Hot Mirror Filters

HUYGENS PRINCIPLE AND INTERFERENCE

Anti-reflection Coatings

Photonics and Optical Communication

Slide 1 / 99. Electromagnetic Waves

Measurement of the Speed of Light in Air

Preview of Period 2: Electromagnetic Waves Radiant Energy I

Part I. Experimental Investigation

SPECTROCLICK KIT EXPLORE THE INTERACTION OF LIGHT AND MATTER THE SCIENCE OF SPECTROSCOPY. 101 W. Tomaras Ave. Bldg.

Exercise 8: Interference and diffraction

Fig On Fig. 6.1 label one set of the lines in the first order spectrum R, G and V to indicate which is red, green and violet.

Chapter 14. Tunable Dye Lasers. Presented by. Mokter Mahmud Chowdhury ID no.:

Explain what is meant by a photon and state one of its main properties [2]

Application Note (A11)

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

Lithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004

SP-8001 UV/Visible Spectrophotometer

The FTNIR Myths... Misinformation or Truth

(12) United States Patent (10) Patent No.: US 6,559,941 B1

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

Human Retina. Sharp Spot: Fovea Blind Spot: Optic Nerve

Advanced Features of InfraTec Pyroelectric Detectors

SpectroMaster. High Precision Automatic Spectrometer-Goniometer

Unit 8: Light and Optics

... frequency, f speed, v......

T92+ UV-VIS SPECTROPHOTOMETER

Introduction to the operating principles of the HyperFine spectrometer

UV/Optical/IR Astronomy Part 2: Spectroscopy

UV-Vis-NIR Spectrophotometer Quick Start Guide

The Nature of Light. Light and Energy

Transcription:

Spectrophotometer An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

Spectrophotometer components Excitation sources Deuterium Lamp Tungsten Lamp Monochromators Detectors PMT Grating+slit prism Hollow-cathode lamp

Components of A Spectrophotometer Sources 1- Wavelength selectors (filters, monochromators) 2- Sample containers 3 Detectors 4 Readout devices Spectrophotometer components can be arranged as a single or a double beam instrument. 3

Radiation Sources Sources of radiation should be stable and of high intensity Sources used in molecular UV-Vis Spectrophotometers are continuous sources. Continuous sources emit radiation of all wavelengths within the spectral region for which they are to be used. Line sources : emit monochromatic radiation and will be discussed in later units, example Hollow Cathode Lamb ( HCL ). 4

Radiation sources The most common continuous sources are : a)tungsten lamp: Vis (320 nm~2500 nm) heat solid filament to glowing, light emitted b) Deuterium lamp: UV (200~400nm) In presence of arc, some of the electrical energy is absorbed by D2 (or H2) which results in the disassociation of the gas and release of light D2 + Eelect D * D + D + 2 hv (light produced) Excited state

Selection of wavelength Absorbance measurements are always carried out at fixed wavelength (using monochromatic light). When a wavelength is chosen for quantitative analysis, three factors should be considered 1. Wavelength should be chosen to give the highest possible sensitivity. This can be achieved by selecting max or in general the wavelengths at which the absorptivity is relatively high. 7

λ max λmax - wavelength where maximum absorbance occurs.

Absorbance By performing the analysis at such wavelengths, it will be sure that the lowest sample concentration can be measured with fair accuracy. max 1 wavelength For example, in the above figure the lowest sample concentration (10-5 M) can be measured with good accuracy at max, while at other wavelength ( 1), it may not be detected at all.

2. It is preferable to choose the wavelength at which the absorbance will not significantly change if the wavelength is slightly changed, i.e., A / is minimum. At a wavelength corresponding to broad horizontal band on the spectrum (band A), the radiation is mainly absorbed to the same extent ( A / zero). However on a steep portion of the spectrum (band B), the absorbance will change greatly if the wavelength is changed ( A / is large). Thus on repeating the absorbance measurements, you might get different readings and the precision of the measurements will be poor.

Absorbance 3- If the solution contains more than absorbing species, the wavelength should be chosen, whenever possible, in region at which the other species does not absorb radiation or its absorbance is minimum. By this way, the second species max wavelength

By choosing different wavelengths of light (ʎA vs. ʎB) different compounds can be measured A B

(1) Best choice compound (a) (2) Best choice compound (b) (3) Bad choice for either compound (a) or (b)

Selection of wavelength From the above discussion and in order to get the appropriate wavelength, the polychromatic radiation from a source should be separated into narrow band of wavelength (nearly monochromatic light) by a wavelength selector ( monochromator ). There are Various types of monochromators based on filters (cheap) based on prisms (limited applications ) based on gratings. (great)

Filters Filters permit certain bands of wavelength (bandwidth of ~ 50 nm) to pass through. The simplest kind of filter is absorption filters, the most common of this type of filters is colored glass filters. They are used in the visible region. The colored glass absorbs a broad portion of the spectrum (complementary color) and transmits other portions (its color).

Reflecting filter Absorbing filters

Disadvantage of filters They are not very good wavelength selectors and can be used only in cheap instruments such as field instruments. This is because they allow the passage of a broad bandwidth which gives a chance for deviations from Beer s law. They absorb a significant fraction of the desired radiation

Grating monochromators Reflection grating Polychromatic radiation from the entrance slit is collimated (made into beam of parallel rays) by a concave mirrors These rays fall on a reflection grating, whereupon different wavelengths are reflected at different angles. The orientation of the reflection grating directs only one narrow band wavelengths, 2, to the exit slit of the monochromator. Rotation of the grating allows different wavelengths, 1 or 3, to pass through the exit slit

A diffraction grating is a periodically structure of subsequent most evenly spaced grating lines. Those grooves or opaque lines diffract the incident light depending on, number of lines ( no./cm ), distance between line d and on the light's incidence angle i.

Grating equation ( n = d (sin i + sin r ) where n order of radiation = 1, 2, 3,. Since incident angle i = constant; therefore r r varies with n. groove-spacing d. reflected incident r i Reflection Grating d

The spectral resolving power R of a grating is given by R = ʎ - / ʎ= n N where n is the order and N is the number of grooves in the grating, so the objective is to maximize R, meaning we wish to maximize n and N. This is a measure of the minimum wavelength difference, Δλ, which can be distinguished by the grating. Its actual definition is the ratio of the average of two just distinguishable wavelengths ʎ- divided by their difference Δʎ. Example : Calculate the resolution of a reflection grating that can separate 299 nm light from 302 nm light. Solution : ʎ- = (299 + 302 ) / 2 = 300.5 R = wavelength/delta wavelength = ʎ- / Δʎ = 300.5 nm/ 3 nm = 100.2

Prism monochromators Dispersion by prism depends on refraction of light which is wavelength 800 nm dependent. Violet color with higher energy (shorter wavelength) are diffracted 400 nm or bent most While red light with lower energy (longer wavelength are diffracted or bent least. As a result, the poly-chromatic white light is dispersed to its individual colors.

BANDWIDTH CHOICE What are the advantages and disadvantages of decreasing monochromator slit width? The size of the monochromator exit slit determines the width of radiation (bandwidth) emitted from the monochromator. A wider slit width gives higher sensitivity because higher radiation intensity passes to the sample but on the other hand, narrow slit width gives better resolution for the spectrum i.e. less spectral interferences. In general, the choice of slit width to use in an experiment must be made by compromising these two factors. Still, we can overcome the problem of low sensitivity of the small slit by increasing the sensitivity of the detector.

Sample compartment (cells) For Visible and UV spectroscopy, a liquid sample is usually contained in a cell called a cuvette. Glass is suitable for visible ( 300 900 nm ) but not for UV spectroscopy because it absorbs UV radiation. Quartz can be used in UV as well as in visible ( 200 3000 nm) but expensive. Must be more or less transparent to the wavelengths of light in use.

Long pathlength 1 cm pathlength cuvet Short pathlength (b)

Detectors The detectors are devices that convert radiant energy into electrical signal. A Detector should be sensitive, and has a fast response over a considerable range of wavelengths. In addition, the electrical signal produced by the detector must be directly proportional to the transmitted intensity (linear response). Various types, the most common are : Photographic films (not widely in use any more) Phototubes (used in simpler instruments) Photomultiplier tubes (used in more complex instruments)

Phototube Phototube emits electrons from a photosensitive,negatively charged cathode when struck by visible or UV radiation. The electrons flow through vacuum to an anode to produce current which is proportional to radiation intensity. Photosensitive cathode amplifier -V anode

Photomultiplier tube electrons emitted from the photosensitive cathode due to striking radiation strike a second surface called dynode. Electrons are thus accelerated and can knock out more than one electrons from the dynode. If the above process is repeated several times, so more than 106 electrons are finally collected for each photon striking the first cathode.

Photomultiplier tube Process: a) light hits photosensitive cathode and e - is emitted. b) an emitted e - is attracted to electrode (dynode 1). Causes several more e- to be emitted. c) these e- are attracted to dynode 2, emitting more e-. d) process continues until e- are collected at anode after amplification at 9 dynodes. e) one photon produces 106 107 electrons. f) current is amplified and measured. There are various types of photomultiplier tubes.

Photomultiplier tube

Photomultiplier tube

Detector response depends on the λ of the incident photons Different wavelengths require different detectors.

The components of a single beam spectrophotometer Light source slits slits

DOUBLE BEAM SPECTROPHOTOMETER Beam Chopper Semi-transparent Mirror Sample Tungsten Lamp Slit Reference Quartz Cuvettes Mirror Mirror

Spectrophotometer : a) Single-beam b) Double-beam

In double beam arrangement, the light alternately passes through the sample and reference (blank), directed by rotating halfsector mirror (chopper) into and out of the light path. When light passes through the sample, the detector measures the P. When the chopper diverts the beam through the blank solution, the detector measures P0. The beam is chopped several times per second and the electronic circuit automatically compares P and P0 to calculate absorbance and Transmittance.

Advantages of double beam over single beam instrument Single beam spectrophotometer is inconvenient because The sample and blank must be placed alternately in the light path. For measurements at multiple wavelengths, the blank must be run at each wavelength. While in double beam,the absorption in the sample is automatically corrected for the absorption occurring in the blank, since the readout of the instrument is log the difference between the sample beam and the blank beam. Small changes in P have no effect in double beam but may have great effect with single beam. Why?

..Cont d In double beam instruments, automatic correction for changes of the source intensity and changes in the detector response with time or wavelength because the two beams are compared and measured at the same time. In double beam we can make automatic scanning and continuous recording of spectrum (absorbance versus wavelength) which we can not with single beam.