Verizon Wireless Proposed Base Station (Site No Berkeley Bekins ) 2721 Shattuck Avenue Berkeley, California

Similar documents
Royal Street Communications, LLC Proposed Base Station (Site No. LA0366A) 315 4th Avenue Venice, California

Verizon Wireless Proposed Base Station (Site No South Goleta ) 4500 Hollister Avenue Santa Barbara, California

AT&T Mobility Proposed Base Station (Site No. CN4779A) 1101 Keaveny Court Walnut Creek, California

Verizon Wireless Proposed Base Station (Site No Lake Cachuma ) 2680 Highway 154 Santa Barbara County, California

Verizon Wireless Proposed Base Station (Site No Palos Verdes ) 1506 Camino Verde Walnut Creek, California

Sutro Tower, Inc San Francisco, California

PROJECT SUPPORT STATEMENT APN: Meadow Lane Court, Placerville, CA

Location Map. Legend. Exhibit A5

Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report

Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report

Calculated Radio Frequency Emissions Report. Cotuit Relo MA 414 Main Street, Cotuit, MA 02635

2200 Noll Drive Lancaster, PA Latitude: N 40º (NAD 83) Longitude: W 76º (NAD 83) 362 AMSL

RF EMISSIONS COMPLIANCE REPORT. Verizon Wireless. Report Status: Verizon Wireless is Compliant

Wireless Facility Engineering Review

CITY OF PACIFIC GROVE 300 Forest Avenue, Pacific Grove, California AGENDA REPORT. Item 8a

Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report

ELECTROMAGNETIC ENERGY (EME) EXPOSURE REPORT

Before the Federal Communications Commission Washington, D.C

Wireless Facility Engineering Review

WHITEPAPER WHITEPAPER

Wireless Facility Peer Engineering Review

C. CEQA Determination: Categorically exempt pursuant to Section of the CEQA Guidelines ( Existing Facilities ).

RADIO FREQUENCY NIER REPORT

Regulatory Authority of Bermuda report on

Wireless Facility Radio Frequency Exposure Compliance Review

MAXIMUM PERMISSIBLE EXPOSURE STUDY

ELECTROMAGNETIC ENERGY (EME) EXPOSURE REPORT

Report On. RF Exposure Assessment of the Sepura plc SRG3900 with AQHB Antenna. FCC ID: XX6SRG3900UW Industry Canada ID: 8739A-SRG3900UW

Health Issues. Introduction. Ionizing vs. Non-Ionizing Radiation. Health Issues 18.1

RADIOFREQUENCY ELECTROMAGNETIC FIELDS

Human Exposure Requirements for R&TTE and FCC Approval

Radio Frequency Emissions Analysis Report Sprint Wireless Water Tank Facility

Measurements of Exposures Around Vodafone New Zealand Limited Cellsites from June 2012 to May 2013

RF Exposure Assessment Report (FCC ID: 2AD8UAZRBRH1)

Safety Code 6 (SC6) Measurement Procedures (Uncontrolled Environment)

Verizon Wireless Site ID Lime Site Name Lime Site Compliance Report

NON-IONIZING ELECTROMAGNETIC EXPOSURE ANALYSIS & ENGINEERING CERTIFICATION

RF EMISSIONS FROM SMART GRID ELECTRIC METERS, HAN DEVICES, AND THEIR RELATIONSHIP TO THE FCC MAXIMUM PERMISSIBLE EXPOSURE LIMIT (MPE)

Modify Section , Major Impact Services and Utilities, of Chapter (Civic Use Types):

Modeling Electromagnetic Radiation on Lookout Mountain, Colorado

ELECTROMAGNETIC FIELD (EMF) STRENGTH MEASUREMENTS SITE: ROHRERSTOWN ELEMENTARY SCHOOL OCTOBER 16, 2017

COMMUNITY BENEFITS. How Mobile Devices are Used Today (Mobile Device: Cellular Phones, Tablets, etc..)

Model: M /800 MHz Mobile Radio

CALCULATING RADIOFREQUENCY FIELD STRENGTH SAFETY CODE 6 SITE VALIDATION

Frequently Asked Questions about Wireless Facilities on Wooden Utility Poles and Streetlight Poles

Guidelines for the Protection of the General Public in Compliance with Safety Code 6

Report On. Radio Frequency Exposure Testing of the Winland Electronics, Inc. EnviroAlert Electronic Multi-Zone Environmental Alarm System

SAR REPORT. TEST STANDARDS: FCC Part 15 Subpart C Intentional Radiator. ARRIS Model Spectrum 110A Set Top Box With Bluetooth (DSS) and RF4CE (DTS)

ITU-T Study Group 5. EMF Environmental Characterization

NIR MEASUREMENTS. Principles and practices of EMF characterization and measurements

EN 62479:2010 ASSESSMENT REPORT WIN CHANNEL ELECTRONICS (HK) CO., LTD

Honeywell, Automation and Control Solutions

Before the Federal Communications Commission Washington DC 20554

ARLINGTON COUNTY, VIRGINIA. County Board Agenda Item Meeting of September 15, 2012

SAFETYTRAINING INFORMATION Your TYT ELECTRONICS CO.,LTD radio generates RF electromagnetic energy during transmit mode. This radio is designed for and

Honeywell, Automation and Control Solutions

MINOR SITE PLAN APPLICATION TOWER COLLOCATION OR MODIFICATION (ELIGIBLE FACILITIES)

: PERSONAL WIRELESS TELECOMMUNICATIONS SERVICE FACILITIES: REGULATIONS AND DEVELOPMENT STANDARDS:

FEDERAL COMMUNICATIONS COMMISSION (FCC) COMPLIANCE STUDY ON TELECOMMUNICATION FACILITY

R ICHARD T ELL A SSOCIATES, INC.

COMMUNITY BENEFITS. How Mobile Devices are Used Today (Mobile Device: Cellular Phones, Tablets, etc..)

Mark E. Revis March 10, 2008 Radio Engineer II County of Riverside - PSEC Project 1855 Chicago Ave. Riverside, California

Intertek Testing Services ETL SEMKO

Electric Imp, Inc. IMP003-FCC FCC :2014. Report # ELIM NVLAP Lab Code:

Re. Invitation to Comment on a Proposed Small Cell Telecommunications Installation Near (Road reserve) Coogee Bay Road COOGEE NSW 2034

3G Mini-Card Gobi2000

Radiofrequency (RF) Safety Overview Massachusetts Environmental Health Association

TEST REPORT. Table of Contents

The Rationale for Negligible Risk Exemptions in the Telecommunications Act of 1996: Cellular Phone and Personal Communication System Transmitters

Product Safety and RF Energy Exposure Booklet for Mobile Two-Way Radios Installed in Vehicles or as Fixed Site Control Stations ATTENTION!

Order Number : GETEC-C FCC Part 1 Test Report Number : GETEC-E Page 2 / 15 CONTENTS

JERROLD T. BUSHBERG Ph.D., DABMP, DABSNM HEALTH AND MEDICAL PHYSICS CONSULTING

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3

Safety Code 6 Analysis Freedom Mobile 3G & LTE Network. Radio frequency exposure for uncontrolled and controlled environment.

MACKENZIE & ALBRITTON LLP 220 SANSOME STREET, 14 FLOOR - SAN FRANCISCO, CALIFORNIA 94104

Safety Code 6 Compliance Analysis of NLA031. Study conducted by Eastlink, Radio Frequency Engineering Department

Mitigation of Radiation Levels for Base Transceiver Stations based on ITU-T Recommendation K.70

Abbey Court Irish Life Centre Lower Abbey Street Dublin 1 Tel Fax Web

Minimum Antenna Elevation for Specific Fraction of SC6 Limits Version 1.0 Standard May 7, 2009

2310 to 2390 MHz, 3m distance MCS8 (MIMO) to 2500 MHz Restricted band MCS8 (MIMO)

Product Compliance Assessments of Low Power Radio Base Stations with Respect to Whole-Body Radiofrequency Exposure Limits

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

PROJECT DESCRIPTION AT&T Proposed Telecommunications Facility 2700 Watt Avenue APN#

Code of Practice for Proposed Mobile Phone Base Station Installations on University Premises.

CoServ Electric s RF Mesh Advanced Metering Infrastructure. RF/EMF Investigation

Radio Frequency Exposure Test Report

Abbey Court Irish Life Centre Lower Abbey Street Dublin 1 Tel Fax Web

RF Radiation Safety Training

Abbey Court Irish Life Centre Lower Abbey Street Dublin 1 Tel Fax Web

Abbey Court Irish Life Centre Lower Abbey Street Dublin 1 Tel Fax Web

Abbey Court Irish Life Centre Lower Abbey Street Dublin 1 Tel Fax Web

Abbey Court Irish Life Centre Lower Abbey Street Dublin 1 Tel Fax Web

TOWN OF LOS ALTOS HILLS April 4, 2013 Staff Report to the Planning Commission

8370 Court Avenue, Suite B-1 Ellicott City, Maryland (410) FCC CERTIFICATION

FCC PART 95 MEASUREMENT AND TEST REPORT. Powerwerx, Inc.

Essentia Electromagnetic Monitor Model: EM2

Wireless Facility Radio Frequency Compliance Review

SAR Evaluation Considerations for Handsets with Multiple Transmitters and Antennas

Compliance Engineering Ireland Ltd RAYSTOWN, RATOATH ROAD, ASHBOURNE, CO. MEATH, IRELAND Tel: Fax:

Power Handling Considerations in a Compact Range

Transcription:

Statement of Hammett & Edison, Inc., Consulting Engineers The firm of Hammett & Edison, Inc., Consulting Engineers, has been retained on behalf of Verizon Wireless, a personal wireless telecommunications carrier, to evaluate the base station (Site No. 156621) proposed to be located at 2721 Shattuck Avenue in Berkeley, California, for compliance with appropriate guidelines limiting human exposure to radio frequency ( RF ) electromagnetic fields. Prevailing Exposure Standards The U.S. Congress requires that the Federal Communications Commission ( FCC ) evaluate its actions for possible significant impact on the environment. In Docket 93-62, effective October 15, 1997, the FCC adopted the human exposure limits for field strength and power density recommended in Report No. 86, Biological Effects and Exposure Criteria for Radiofrequency Electromagnetic Fields, published in 1986 by the Congressionally chartered National Council on Radiation Protection and Measurements ( NCRP ). Separate limits apply for occupational and public exposure conditions, with the latter limits generally five times more restrictive. The more recent Institute of Electrical and Electronics Engineers ( IEEE ) Standard C95.1-1999, Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 khz to 300 GHz, includes nearly identical exposure limits. A summary of the FCC s exposure limits is shown in Figure 1. These limits apply for continuous exposures and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. The most restrictive limit for exposures of unlimited duration to radio frequency energy for several personal wireless services are as follows: Personal Wireless Service Approx. Frequency Occupational Limit Public Limit Personal Communication ( PCS ) 1,950 MHz 5.00 mw/cm 2 1.00 mw/cm 2 Cellular Telephone 870 2.90 0.58 Specialized Mobile Radio 855 2.85 0.57 [most restrictive frequency range] 30 300 1.00 0.20 General Facility Requirements Base stations typically consist of two distinct parts: the electronic transceivers (also called radios or cabinets ) that are connected to the traditional wired telephone lines, and the passive antennas that send the wireless signals created by the radios out to be received by individual subscriber units. The transceivers are often located at ground level and are connected to the antennas by coaxial cables about 1 inch thick. Because of the short wavelength of the frequencies assigned by the FCC for wireless services, the antennas require line-of-sight paths for their signals to propagate well and so are installed at some height above ground. The antennas are designed to concentrate their energy toward Page 1 of 4

the horizon, with very little energy wasted toward the sky or the ground. Along with the low power of such facilities, this means that it is generally not possible for exposure conditions to approach the maximum permissible exposure limits without being physically very near the antennas. Computer Modeling Method The FCC provides direction for determining compliance in its Office of Engineering and Technology Bulletin No. 65, Evaluating Compliance with FCC-Specified Guidelines for Human Exposure to Radio Frequency Radiation, dated August 1997. Figure 2 attached describes the calculation methodologies, reflecting the facts that a directional antenna s radiation pattern is not fully formed at locations very close by (the near-field effect) and that the power level from an energy source decreases with the square of the distance from it (the inverse square law ). The conservative nature of this method for evaluating exposure conditions has been verified by numerous field tests. Site and Facility Description Based upon information provided by Verizon, including drawings by ATI Architects and Engineers, dated March 30, 2006, it is proposed to mount six Andrew antennas, three Model DB854DG65VTESX directional cellular antennas and three Model 931LG65VTE-B directional PCS antennas, high on the side walls of the four-story storage building located at 2721 Shattuck Avenue in Berkeley. The antennas would be mounted with 4 downtilt at an effective height of about 56 feet above ground and would be oriented in pairs toward 70 T, 160 T, and 340 T. The maximum effective radiated power in any direction would be 2,600 watts, representing simultaneous operation at 1,200 watts for PCS and 1,400 watts for cellular service. Proposed to be located above the roof and on the outside of the same building are similar antennas for use by Sprint Nextel and by T-Mobile, respectively, other wireless telecommunications carriers. Sprint Nextel reports that it will be using twelve Andrew Model DB844H65E-XY directional SMR antennas mounted with 3 downtilt at an effective height of about 67 1 /2 feet above ground, 9 1 /2 feet above the roof, and would operate with a maximum effective radiated power in any direction of 210 watts. T-Mobile reports that it will install Andrew Model ADFD1820-6565B directional PCS antennas at an effective height of about 57 1 /2 feet above ground and would operate with a maximum effective radiated power in any direction of 800 watts. Study Results For a person anywhere at ground, the maximum ambient RF level due to the proposed Verizon operation by itself is calculated to be 0.0048 mw/cm 2, which is 0.81% of the applicable public limit. The maximum calculated cumulative level at ground for the simultaneous operation of all three Page 2 of 4

carriers is 0.89% of the public exposure limit. The maximum calculated cumulative level on the roof of the subject building is 73% of the public exposure limit; the maximum calculated cumulative level on the roof of any nearby building is 2.6% of the public exposure limit. It should be noted that these results include several worst-case assumptions and therefore are expected to overstate actual power density levels. Recommended Mitigation Measures Due to their mounting locations, the Verizon antennas are not accessible to the general public, and so no mitigation measures are necessary to comply with the FCC public exposure guidelines. To prevent occupational exposures in excess of the FCC guidelines, no access within 8 feet in front of the Verizon antennas themselves, such as might occur during building maintenance activities, should be allowed while the site is in operation, unless other measures can be demonstrated to ensure that occupational protection requirements are met. Posting explanatory warning signs * at roof access locations and at the antennas, such that the signs would be readily visible from any angle of approach to persons who might need to work within that distance, would be sufficient to meet FCC-adopted guidelines. Similar measures should be implemented for the other carriers at the site; applicable keep-back distances have not been determined as part of this study. Conclusion Based on the information and analysis above, it is the undersigned s professional opinion that the base station proposed by Verizon Wireless at 2721 Shattuck Avenue in Berkeley, California, will comply with the prevailing standards for limiting public exposure to radio frequency energy and, therefore, will not for this reason cause a significant impact on the environment. The highest calculated level in publicly accessible areas is much less than the prevailing standards allow for exposures of unlimited duration. This finding is consistent with measurements of actual exposure conditions taken at other operating base stations. Posting of explanatory signs is recommended to establish compliance with occupational exposure limitations. * Warning signs should comply with ANSI C95.2 color, symbol, and content conventions. In addition, contact information should be provided (e.g., a telephone number) to arrange for access to restricted areas. The selection of language(s) is not an engineering matter, and guidance from the landlord, local zoning or health authority, or appropriate professionals may be required. Page 3 of 4

Authorship The undersigned author of this statement is a qualified Professional Engineer, holding California Registration Nos. E-13026 and M-20676, which expire on June 30, 2007. This work has been carried out by him or under his direction, and all statements are true and correct of his own knowledge except, where noted, when data has been supplied by others, which data he believes to be correct. May 10, 2006 William F. Hammett, P.E. Page 4 of 4

FCC Radio Frequency Protection Guide The U.S. Congress required (1996 Telecom Act) the Federal Communications Commission ( FCC ) to adopt a nationwide human exposure standard to ensure that its licensees do not, cumulatively, have a significant impact on the environment. The FCC adopted the limits from Report No. 86, Biological Effects and Exposure Criteria for Radiofrequency Electromagnetic Fields, published in 1986 by the Congressionally chartered National Council on Radiation Protection and Measurements, which are nearly identical to the more recent Institute of Electrical and Electronics Engineers Standard C95.1-1999, Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 khz to 300 GHz. These limits apply for continuous exposures from all sources and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. As shown in the table and chart below, separate limits apply for occupational and public exposure conditions, with the latter limits (in italics and/or dashed) up to five times more restrictive: Frequency Applicable Range (MHz) Electromagnetic Fields (f is frequency of emission in MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Equivalent Far-Field Power Density (mw/cm 2 ) 0.3 1.34 614 614 1.63 1.63 100 100 1.34 3.0 614 823.8/ f 1.63 2.19/ f 100 180/ f 2 3.0 30 1842/ f 823.8/ f 4.89/ f 2.19/ f 900/ f 2 180/ f 2 30 300 61.4 27.5 0.163 0.0729 1.0 0.2 300 1,500 3.54 f 1.59 f f /106 f /238 f/300 f/1500 1,500 100,000 137 61.4 0.364 0.163 5.0 1.0 1000 Occupational Exposure Power Density (mw/cm 2 ) 100 10 1 PCS Cell FM 0.1 Public Exposure 0.1 1 10 100 10 3 10 4 10 5 Frequency (MHz) Higher levels are allowed for short periods of time, such that total exposure levels averaged over six or thirty minutes, for occupational or public settings, respectively, do not exceed the limits, and higher levels also are allowed for exposures to small areas, such that the spatially averaged levels do not exceed the limits. However, neither of these allowances is incorporated in the conservative calculation formulas in the FCC Office of Engineering and Technology Bulletin No. 65 (August 1997) for projecting field levels. Hammett & Edison has built those formulas into a proprietary program that calculates, at each location on an arbitrary rectangular grid, the total expected power density from any number of individual radio sources. The program allows for the description of buildings and uneven terrain, if required to obtain more accurate projections. FCC Guidelines Figure 1

RFR.CALC Calculation Methodology Assessment by Calculation of Compliance with FCC Exposure Guidelines The U.S. Congress required (1996 Telecom Act) the Federal Communications Commission ( FCC ) to adopt a nationwide human exposure standard to ensure that its licensees do not, cumulatively, have a significant impact on the environment. The maximum permissible exposure limits adopted by the FCC (see Figure 1) apply for continuous exposures from all sources and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. Higher levels are allowed for short periods of time, such that total exposure levels averaged over six or thirty minutes, for occupational or public settings, respectively, do not exceed the limits. Near Field. Prediction methods have been developed for the near field zone of panel (directional) and whip (omnidirectional) antennas, typical at wireless telecommunications cell sites. The near field zone is defined by the distance, D, from an antenna beyond which the manufacturer s published, far field antenna patterns will be fully formed; the near field may exist for increasing D until some or all of three conditions have been met: 1) D > 2h2 2) D > 5h 3) D > 1.6 where h = aperture height of the antenna, in meters, and = wavelength of the transmitted signal, in meters. The FCC Office of Engineering and Technology Bulletin No. 65 (August 1997) gives this formula for calculating power density in the near field zone about an individual RF source: power density S = 180 BW 0.1 P net D h, in mw /cm 2, where BW = half-power beamwidth of antenna, in degrees, and P net = net power input to the antenna, in watts. The factor of 0.1 in the numerator converts to the desired units of power density. This formula has been built into a proprietary program that calculates distances to FCC public and occupational limits. Far Field. OET-65 gives this formula for calculating power density in the far field of an individual RF source: 2.56 1.64 100 RFF power density S = 2 ERP 4 D 2, in mw /cm 2, where ERP = total ERP (all polarizations), in kilowatts, RFF = relative field factor at the direction to the actual point of calculation, and D = distance from the center of radiation to the point of calculation, in meters. The factor of 2.56 accounts for the increase in power density due to ground reflection, assuming a reflection coefficient of 1.6 (1.6 x 1.6 = 2.56). The factor of 1.64 is the gain of a half-wave dipole relative to an isotropic radiator. The factor of 100 in the numerator converts to the desired units of power density. This formula has been built into a proprietary program that calculates, at each location on an arbitrary rectangular grid, the total expected power density from any number of individual radiation sources. The program also allows for the description of uneven terrain in the vicinity, to obtain more accurate projections. Methodology Figure 2