Product description. At a glance. Customer benefits

Similar documents
ADJUSTABLE SPEED DRIVES. AS1 Drive

HV580L Series Frequency Inverter User Manual

Manual Overview...1 2

HV580 Series Frequency Inverter User Manual

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

S11 Adjustable Speed Drive Engineering Specification

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

Fan and Pump AC Inverter

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

VF-nC1 Adjustable Speed Drive Engineering Specification

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

DORNA TECHNOLOGY CO., LTD. DLA1 Series Inverter. User Manual (V1.0)

Inverter Drive /Vector Drive Motors & Controls

E3 Adjustable Speed Drive Engineering Specification

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

ADTECH Solar inverter

FUJI Inverter. Standard Specifications

SJ700 series High performance with Many useful Functions and, yet User Friendly. WJ200 series Pursuing the Ideal Compact Inverter NEW

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

EMHEATER. EM11 Series Frequency Inverter. User s Manual. China EM Technology Limited. Address:

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

General Specifications FECA-TE /2010. Phone: Fax: Web:

Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC

WJ200 series Pursuing the Ideal Compact Inverter

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

EMHEATER. EM11 Series Frequency Inverter. User s Manual. China EM Technology Limited. EM11 Series Inverter User s Manual. Address:

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

Frequency Converter Fv vector control converters for universal applications

G1 serials General Vector Inverter

SX (400 V) System configuration

GS1 Parameter Summary Detailed Parameter Listings...4 9

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

This Chapter contains:

YL6000 Frequency Converter

EFC 3600 Frequency converter for higher energy efficiency and improved process control

The new Yaskawa Varispeed G7 Inverter

SX (400V) System configuration

Frequency Inverters. SJ700B Series. Powerful Inverter for General Purpose Use. SJ700B Series

vacon nxs robust drive for heavy use

FREQUENCY INVERTER VFR-013 QUICK START GUIDE

SX (690 V) System configuration

Contents. Safety Information and Precautions Product Information Operation Panel (Keypad & Display) Quick Setup...

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

TOSVERT TM VF-nC3 Parameter List

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Intelligent Drive Systems, Worldwide Services SK 700E F 3070 GB

9. RS485 Communication (Option)

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ADJUSTABLE SPEED DRIVES FS1

ACH550 HVAC Drive Submittal

CTi Automation - Phone: Fax: Web: -

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

Frequency Inverters. VF-nC3 VF-S11 VF-FS1 VF-PS1 VF-AS1

MD310 Quick Start Manual. General-Purpose AC Drive

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD.

BOSTON GEAR CONTROLLERS. ACE 20 Series 1/8 through 10 HP Adjustable Frequency AC Motor Controllers. MTY (81)

9. RS485 Communication

С210/С410 Series Compact design, small appearance and easy to operate

Input power type: S2 means single-phase 230VAC T3 means three-phase 400VAC. Motor power. Relation. Mark Motor power (kw)

ZVF9V-G Series Frequency Inverter

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 10

HPVFP High Performance Full Function Vector Frequency Inverter

Design Characteristics. FlexDrive II. Series

C.TY TNHH TỰ ĐỘNG HÓA VIỆT TRUNG Preface

PRODUCT OFFERING ADJUSTABLE SPEED DRIVES

EMHEATER. EM9 Series Frequency Inverter. User s Manual. China EM Technology Limited. EM9 Series Inverter User s Manual. Address:

HV350 Series Mini Frequency Inverter User Manual

Operating Instructions

Goodrive 300 Inver ter

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

Single-phase or three phase AC220V (-15% ~ +10%) 50 ~ 60Hz

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

General Purpose Drives

TECHNICAL SPECIFICATION INVERTER VEGA DRIVE

AC Series General Purpose Frequency Inverter

CHAPTER 8 PARAMETER SUMMARY

Content. Goodrive20 inverters

Content. Goodrive20 inverters

PRODUCT OFFERING ADJUSTABLE SPEED DRIVES

DS2 series servo drive

AF91 Adjustable Frequency Drives Series B

Preface. Notes. Thank you for purchasing the VTP8 series AC drive.

IRT Mini Evo. Technical Manual. quality IN MOTION. quality IN MOTION

1.1 Product model naming rule EM30 EM T3 J1. Structure Code: J1: 270*190*165 J2: 338*228*193.5

Input power type: S2 means single-phase 230VAC T3 means three-phase VAC. Motor power. Relation

Contents Foreword... 1 Chapter 6 Parameter Description Chapter 1 Safety and Precautions... 5 Chapter 2 Product Information...

NX series Constant and variable torque Variable Speed Drives for induction motors

VFS11 Parameter List for up to CPU version 105

CONTENT Chapter 1 Overview... 1

Transcription:

Product description New series is a general current vector control inverter integrated with the performance and features in a high degree. with industry-leading drive performance and functionality control, using unique current vector control algorithm can efficiently drive induction motor to achieve high accuracy, high torque and high-performance control. Customer success, Market Service! in terms of performance and control are worthy of trust! At a glance Advanced motor control technology support both Open loop vector control(svc), Closed loop vector control(fvc) and V/F control Different input voltage(0v single phase/0v phase/80v phase/460v phase) High starting torque characteristics and precise speed control Rich and flexible I/O accesses and field bus options Additional information Product description...-0 At a glance... -0 Customer benefits...-0 Specificaiton... -0 Specificaiton... -0 Specificaiton... -04 Model Definition...-05 Model Definition...-06 Model Definition...-0 Dimensional Drawing... -08 Dimensional Drawing... -09 Dimensional Drawing... -0 Dimensional Drawing... - Connection Diagram... - Customer benefits Suitable for all regions which have different grid and voltage Upgrade I/O(NPN/PNP compatible) can meet more application requirement without controller(plc) like elevator, textile etc. Programmable DI/DO/AI/AO as well as RS485 Modbus RU make easy communication with other devices www.hncelectric.com/ For more information, please enter the link or scan the code via mobile devices and get direct access to technical date,manual,application examples and much more. -0 www.hncelectric.com

Specificaiton Items Description Control system Drive performance Maximum frequency Carrier frequency Input frequency resolution Control mode Startuptorque High performance of current vector control technology to realize asynchronous motor and synchronous motor control High efficiency driving for induction motor and synchronous motor Vector control:0~00hzv/fcontrol:0~00hz 0.5k~6kHz; the carrier frequency will be automatically adjusted according to the load characteristics Digital setting: 0.0Hz Analog setting: maximum frequency 0.05% Open loop vector control(svc) Closed loop vector control(fvc) V/F control ype G:0.5Hz/50%(SVC);0Hz/80%(FVC) Speed range :00(SVC) Speed range Speed stabilizing precision orque control precision ±0.5%(SVC) ±5%(FVC) Speed stabilizing precision Basic function Over load capability orque boost V/F curve V/F separation Acc. /deccurve DC brake Jog control Simple PLC and MS speed running Built-in PID Auto voltage regulation (AVR) Over-voltage/current stall control Quick current limit G type: rated current 50% - minute, rated current 80% - seconds; Auto torque boost function;manual torque boost 0.%~0.0% Linear V/F,Multi-point V/F and Square V/F curve (power of.,.4,.6,.8, ) In ways:separation,semi seperation Straight line or S curve acceleration and deceleration mode. Four kinds of acceleration and deceleration time. Acceleration and deceleration time range between 0.0s to 6500.0s DC brake frequency:0.00hz to maximum frequency,brake time:0.0s to 6.0s, and brake current value: 0.0% to 00.0%. Jog frequency range:0.00hz~50.00hz. Jog acceleration/deceleration time 0.0s~6500.0s. It can realize at maximum of 6 segments speed running via the built-in PLC or control terminal. It is easy to realize process-controlled close loop control system It can keep constant output voltage automatically in case of change of network voltage. It can limit the running voltage/current automatically and prevent frequent over-voltage/current tripping duringthe running process Minimize the over-current fault,protect normal operation of the inverter www.hncelectric.com -0

Items Description orque limit & control "Excavators" characteristics,automatically limit torque during operation,prevent frequent overcurrent trip; Closed loop vector mode can realize the torque control. Instantaneous stop non-stop When instantaneous power off,voltage reduction is compensated through load feedback energy,which could make inverter keep running in a short period of time. Rapid current limit o avoid inverter frequent over-current fault. Virtual I/O 5 groups of virtual DI,DO to realize simple logic control Personalized iming control Multiple motor switch Multi-threaded bus support iming control function:settimerange 0 Min~6500.0Min 4 groups of motor parameter,which can realize 4- motor switch control Support kinds of field bus: RS485, Profibus-DP, CANopen Motor overheat protection Z5PC analog input AIx can accept the motor temperature sensor input(p00 P000) Multi-encoder support Programmable PLC Support difference,open collector, UVW, rotary transformer, sine cosine encoder etc. Select optional user programmable card,which can realize secondary development,programming mode compatible with Drino PLC. Excellent backend software Support inverter parameter operation and virtual oscilloscope function.inverter internal state graphic monitor can be realized through virtual oscilloscope. Running command channel hree types of channels: operationpanel reference,control terminal reference and serial communication portreference.hese channels can be switched in various modes. Frequency source here are totally eleven types of frequency sources, such as digital reference, analog voltage reference, analog current reference, pulse reference, MS speed, PLC, PID and serial port reference. Running Auxiliary frequency source kinds of auxiliary frequency source which can flexible achieve auxiliary frequency tuning, frequency synthesis Standard: here are 6 digital input terminals,di5 can be used as00khz high-speed pulse input. Input terminal analog input terminals which can be used as 0-0V voltage input or 0~0mA current input. Extended function: 4 digital input terminals, analog input terminals support-0~0v voltage input &P00\P00-0 www.hncelectric.com

Items Description Standard: digital output terminals, Y is high-speed pulse output terminal (can be choosen as open circuit collector type), support 0~0kHz square wave signal; relay output terminal; Output terminal analog output terminals, support 0~0mA output current or 0~0V output voltage; Extended function: digital output terminal;; analog output terminal, support 0~0mA output current or 0~0V output voltage. LED display Realize parameter setting,status monitoring function Keyboard potentiometer Equipped with keyboard potentiometer or coding potentiometer Key lock&function selection Realize button locking,define operation range for part of buttons to prevent operation fault. Keyboard operation Protection function It can implement power-on motor short-circuit detection,input/output phase loss protection, over current protection,over voltage protection,under voltage protection,overheating protection and overload protection. Optional parts LCD operation panel, brake component, multifunction extended card (.IO extended card.user programmable card), RS485 communication card, Profibus-DP communication card, CANopen communication card, differential input PG card, UVW differential input PG card, rotating inverter PG card, OC input PG card. Using place Indoor,and befree from direct sunlight,dust, corrosive gas, combustible gas,oilsmoke, vapor,driporsalt. Altitude Below 000m Environment Ambient temperature -0 to +40 (Derating use when under ambient temperature of 40 to 50 ) Humidity Less than 95%RH, without condensing Vibration Less than 5.9 m/s (0.6g) Storage temperature -0 ~+60 www.hncelectric.com -04

Model Definition HV 590 - R5 G Code Voltage HV 590 Series Inverter G single phase 0V G phase 0V NO. Adaptation G phase 80V R5 0.5kW G4 phase 480V R5.5kW 0 kw No. Inverter ype 08 8.5kW G General type 0 0kW P Fanpump type 400 400kW Frequency Inverter Model (kw) Motor adaper PH single phase input :AC 0V,50/60HZ HP Rated Input (A) Rated Output (A) -R40G 0.4 0.5 5.9.5 -R5G 0.5 8. 4 -R5G.5 4. -RG. 4. 0 PH - phase input :AC 0V,50/60HZ -R40G 0.4 0.5 4..5 -R5G -R5G -RG -004G -5R5G 0.5.5. 4.0.5 5. 8.0.8 8. 8.0 4 0 6 5 -R5G.5 0. -0G -05G -08G -0G -00G -0G -045G 5 8.5 0 45 5 0 5 0 40 50 60 49.8 65.4 8.6 9.. 5.4 85. 45 60 5 90 0 5 6-055G 55 0 5.8 0 PH - phase input :AC 80V,50/60HZ -R5G 0.5 4..5 -R5G.5 5.. -RG. 6.0 5-004G 4.0 5 0.5 8.5-05 www.hncelectric.com

www.hncelectric.com -06-5R5G -R5G -0G -05G -00G -0G -045G -055G -05G -09G -0G -G -60G -8G -00G -0G -50G -80G -450G -500G.5.0 5.0 0 45 55 5 90 0 60 85 00 0 50 80 55 400.5 0 5 0 0 40 50 60 0 00 5 50 5 0 45 60 00 50 0 40 50 0.5.5. 49. 65. 80.6 96.4.6 66.4 84. 6.8 68.. 68 406.6 44. 50 555.9 4.5 8.6 Frequency Inverter Model Rated Input (A) Rated Output (A) 450 500 595 60 846.0 885.0 Motor adaper (kw) HP 6 5 45 60 5 90 0 50 0 0 50 00 40 80 45 40 50 650 5 80 860-0G -55G -400G 560 60 50 840 990.0 50 950 00-560G -60G -08G -5G PH - phase input :AC 460V,50/60HZ -RG4-004G4 4. 4.9 5. 9.4.5. 5 8 -R5G4 -R5G4-5R5G4 -R5G4-0G4-05G4-00G4-0G4.5 8.. 9.8 4. 5.4 66.5 5 40 55 65-0G4-08G4 8.5 5 5 500 4.9 650. 8 600.5. 4.0 0.5.5.0 5.0 0 8.5 5.5 0 5 0 0 40 50 5 5. 4

Frequency Inverter Model -045G4-055G4-05G4-09G4-0G4 -G4-60G4-8G4-00G4-0G4-50G4-80G4-5G4-55G4-400G4-450G4-500G4-560G4-60G4 (kw) 45 55 5 90 0 60 85 00 0 50 80 5 55 400 450 500 560 60 Motor adaper HP 60 0 00 5 50 5 0 45 60 00 50 0 Rated Input (A) 8. 0.9.4 5.8 6.0 0. 64. 09.4 4.4 6.9 40.9 45.4 500 5. 40 50 595 60 50 840 6. 06.9 60.0 865.0 90.0 00 Rated Output (A) 80 00 0 4 80 6 59 00 8 58 400 449 56 50 650 00 800 900 000-0 www.hncelectric.com

Dimensional Drawing Product Component Name Dust guard Mounting hole Mounting hole Upper cover Heatsin k Cooling fan Operation panel Nameplate Operationpanel Enclosure Lower cover Nameplate Cover R40G/G~-RG/G -R5G and below power class -0G and above power class Product Outline, Mounting Dimension, and Weight 0R4G~ RG R5G~-R5G and blow power class -0G~-0G power class Product outline and mounting dimension -85G~-400G 5 0.00 + PRG S E M F RUN JOG SOP RS Operation panel outline and mounting dimension www.hncelectric.com -08

Shape DIM -R40G -R5G -R5G -RG -R40G -R5G -R5G -RG -004G -5R5G -R5G -0G -05G -08G -0G -00G -0G -045G -055G -R5G -R5G -RG -004G -5R5G -R5G -0G -05G -08G -0G -00G -0G -045G -055G -05G -090G -0G Wall mounting -G -60G -85G Shape Dimension And Installation Dimension(mm) W H D H W D Assemblyaperture weight (kg) 8.5 85 59 06.5 4.5 50. 8.5 85 59 06.5 4.5 50. 50 58 8.8 6.8 45 5. 4.0 0 0 9 9 50 50.5.5 98 98 8. 8. 80 80 9.6 9.6 6 6 6.6 6.6 4 4 0 0 85 5 50 585 0. 4. 00 0 48 559 460 58 0 9 5 5 585 4. 0 559 58 0 5 5 585 4. 0 559 58 0 5 84 485 650 60 0 6 00 5 68 9 600 0 48 66 8.5 85 59 06.5 4.5 50. 8.5 95 69 06.5 84.5 60.6 50 0 58 8.8 9 6.8 50 45 5. H.5 98 80 9.6 6 6.6 4 0 85 50 0. 00 48 460 9 5 585 4. 0 559 58 0 5 84 485 650 60 0 6 00 5 68 9 5 80 405 5 809 80 94 600 0 4.0 8. 48 66-09 www.hncelectric.com

Shape DIM Shape Dimension And Installation Dimension(mm) W H D H W D H Assemblyaperture weight (kg) Cabinet installation -G -60G -85G Cabinet installation -00G -0G Cabinet installation -50G -80G -5G -55G -400G -450G -500G -560G -60G -R5G4 -R5G4 -RG4-004G4-5R5G4 -R5G4-0G4-05G4-08G4-0G4-00G4-0G4-045G4-055G4-05G4-09G4-0G4 Wall mounting - G4-60G4-85G4 5 405 5 9 5 50 68 40 4 50 4 5 00 6 460 50 59 4 5 800 460 50 4 00 00 000 568 4 400 8.5 85 59 06.5 4.5 50. 8.5 95 69 06.5 84.5 60.6 50 0 58 8.8 9 6.8 50 45 5..5 98 80 9.6 6 6.6 4 0 85 50 0. 00 48 460 9 5 585 4. 0 559 58 0 5 84 485 650 60 0 6 00 5 68 9 5 80 405 5 809 80 94 600 0 4.0 8. 48 66 www.hncelectric.com -0

Shape DIM Cabinet installation - G4-60G4-85G4 Cabinet installation -00G4-0G4 Cabinet installation -50G4-80G4-5G4-55G4-400G4-450G4-500G4-560G4-60G4 Shape Dimension And Installation Dimension(mm) W H D H W D H Assemblyaperture weight (kg) 5 405 5 9 5 50 68 40 4 50 4 5 00 6 460 50 59 4 5 800 460 50 4 00 00 000 568 4 400 - www.hncelectric.com

Connection Diagram Braking Unit DC reactor optional Circult braker B R hree phase ACS power supply R S U V W Morotr Power grounding Main circult Mortor grounding Multi function input Multi function input Multi function input Multi function input 4 Multi function input 5 Multi function input 6 DI DI DI DI4 DI5/HD DI6 Control circult J -short-circuit(default) AOV 0-0V DC - short-circuit AOC 0-0mA DC J -short-circuit(default) AOV 0-0V DC - short-circuit AOC 0-0mA DC AO AO GND P P Analog output Analog output Drain drive(default) +4V SP CM +4V SP J6 J6 A C B Relay output 50V AC/A 0V DC/A source drive 0kΩ P CM +0V AI GND J -short-circuit(default) AIV 0-0V DC - short-circuit AIC 0-0mA DC A C B +4V Relay output 50V AC/A 0V DC/A 0kΩ P +0V AI GND J4 -short-circuit(default) AIV 0-0V DC - short-circuit AIC 0-0mA DC 485 terminal resistor selecting switch J9 Y CM 485+ 485- GND Relay Modbus communication RS485 Shielding cable P wisted shielding cable www.hncelectric.com -