Wireless, Batteryless Push Buttons

Similar documents
Wireless and batteryless pushbuttons

Harmony XB5R. Expert Instruction Sheet 11/ EIO

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

Wireless, Batteryless Push Button

ZBRT2 double actions (up/down) transmitter for wireless and battery less pushbutton

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Zelio Control Measurement Relays

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

Harmony XB5R Expert Instruction Sheet

RENF22R2MMW Zelio Timer Relay - Modular

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

Type CP-S, CP-C & CP-A Switch mode

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

Modular equipment. Presentation, standards. Standard contactors TeSys GC

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

02/11/2015

02/11/2015

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

08/07/2015

Electronic timer CT-TGD.22

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

02/11/2015

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

05/09/2012

Electronic timer CT-SDD.22

Power supply CP-E 24/2.5

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

Three-phase monitoring relay CM-PFS

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

08/07/2015

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Three-phase monitoring relays

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-D 12/2.1

Power supply CP-E 24/20.0

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

02/11/2015

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

PART NUMBERING SYSTEM

Harmony Double and Triple- Headed Push Buttons. Catalog

CP-T range Product group picture

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

CP-E range Benefits and advantages

References 1 for asynchronous motors 1

Type Nominal voltage (V) Code HSV V

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Protection components

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Three-phase monitoring relays CM-PFE and CM-PFE.2

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

em4 em4 alert em4 alert 2G

Pendant control stations 6

27/04/2015

Transcription:

Wireless, Batteryless Push Buttons Harmony XBR Catalog 0

Introduction Figure A: radio transmission between transmitter and receivers Figure B: radio transmission between transmitters and receiver Introduction of the range The Harmony wireless and batteryless push range enables remote control of a relay (receiver) by means of a push (transmitter). Control is by radio transmission: a transmitter is fi tted with a "dynamo" type generator that converts the mechanical energy produced when the push is pressed, to electrical energy. A radio-encoded message with a unique ID code is sent, by a single pulse, to one or more receivers located several dozen meters away (see fi gure A). One receiver can also be actuated by several different transmitters (see fi gure B). Depending on the application, an external antenna can be used to get round an obstacle that impedes transmission or to increase the range (see fi gures A and B). The possible distance () between a transmitter and a receiver is approximately: - ft (00 m) where there are no obstacles, - ft ( m) if the receiver is installed in a metal housing or in a closed metal enclosure, - ft (0 m) if an external antenna is located between the transmitter and the receiver (receiver installed in a metal housing or in a closed metal enclosure). This new technology makes it possible to reduce installation times and costs by totally eliminating wiring and associated equipment between the push and the electrical enclosure. This new technology also allows an operator to be mobile or to have a control mounted on-board a vehicle (trolley, truck, etc.). The push is always available and requires no maintenance (no battery needed). There are numerous possible applications, both in industry (production line, conveyors, etc.) and in industrial buildings and infrastructures (lighting, door opening, start-up of fans, etc.). This technology (radio-encoded message sent as a single pulse) cannot be used for hoisting applications ("up/down", "right-left" movements, etc.) or safety applications (Emergency Stop push s, etc.). For these applications, it is recommended that Harmony XB and XB wired push s or the XAC range of pendant control stations be used. Figure C: pack with transmitter and programmable receiver Description of the Ready-to-use packs ranges () Pack with programmable receiver (see figure C) The pack includes: A transmitter with a mounting collar for assembly with a push head and mounting in a Ø mm hole. A fl ush, spring return, plastic or metal push head. A set of 0 different colored caps, which can be clipped onto the push head. A a/c to 0 V programmable controller, relay outputs, with s (scroll-through and OK). Buttons. Indicating LEDs. 0 () Typical values which can be affected by the application environment. () and receiver already paired at the factory. Specifi cations: page Catalog numbers: page Dimensions, wiring diagrams: page 0

Introduction (continued) Description of the Ready-to-use packs () (continued) Pack with non-programmable receiver (see figure D) The pack includes: A transmitter with a mounting collar for assembly with a push head and mounting in a Ø mm hole. A fl ush, spring return, plastic or metal push head. A black cap that can be clipped onto the push head. A c V non-programmable receiver, relay output, without indicating LED or. Figure D: pack with transmitter and non-programmable receiver Pack with handy box and programmable receiver (see figure E) The pack includes: A handy box containing a wireless and batteryless push with plastic head. A set of 0 different colored caps, which can be clipped onto the push head. A a/c to 0 V programmable receiver, relay outputs, with s (scroll-through and OK) Buttons. Indicating LEDs Figure E: pack with transmitter in handy box and programmable receiver Pack with handy box and non-programmable receiver (see figure F) The pack includes: A handy box containing a wireless and batteryless push with plastic head. A black cap that can be clipped onto the push head. A c V non-programmable receiver, relay output, without indicating LED or. Figure F: pack with transmitter in handy box and non-programmable receiver Description of the Components range Components are sold separately to allow completion of existing applications or creation of specifi c applications: - transmitter for assembly with push head and mounting in a Ø mm hole, - fl ush, spring return, push head, metal or plastic version, - plastic or metal mounting collar, - empty handy box, - empty plastic boxes ( or cut-outs) for wall mounting or on-board applications, - set of 0 different colored caps or set of 0 same color caps, that can be clipped onto the push head, - a/c to 0 V programmable receiver, relay outputs, with s (scroll-through and OK) and indicating LEDs, - c V programmable receiver, PNP outputs, with s (scroll-through and OK) and indicating LEDs, - external antenna. () and receiver already paired at the factory. 0

Specifications Specifications of wireless and batteryless push Environment specifications Conforming to standards Product certifications and radio agreements Protective treatment standard version Ambient air temperature around the device Relative humidity permissible Transmitter block EN/IEC 0-, EN/IEC 0--, UL 0, CSA C- n Transmitter/receiver system e : R&TTE //EC, BT 00//EC, EMC 00/0/EC Radiofrequency EN00-0-, EN00-0-, FCC part., RSS0, ANATEL (resolution 0), SRRC, EMC: EN0--, EN0-- SAR (Specifi c Absorption Rate) compliant. Power transmitted by the < mw Storage F ( C) - 0 to + (- 0 to + 0) Operation F ( C) - to + (- to + 0) Degree of protection Conforming to IEC 0 IP (front face) IP 0 (back face) Conforming to UL / CSA Type UL, FCC (USA), CSA, RSS (Canada), C-Tick (Australia), GOST (Russia), ANATEL (Brazil), SRRC (China), e (Europe) TH + % RH at F (0 C) (without condensation) Mechanical shock protection Conforming to IEC 00 IK 0 Free fall resistance Conforming to IEC 00-- in (mm) (,000) Mechanical specifications Operating travel (when sending information) Operating force Mechanical durability (in millions of operating cycles) Vibration resistance conforming to IEC 00-- Push in (mm) Total travel: 0. (.) Instruction sent when wireless and batteryless push clicks Spring return push with its N < transmitter Spring return push with its transmitter Frequency: to Hz in (mm) ± 0. (± 0) Frequency: to 00Hz gn Shock resistance conforming to IEC 00-- Half sine wave acceleration ms gn 0 Half sine wave acceleration ms gn 0 0 Repetitive shocks resistance Conforming to IEC 00-- gn (duration: ms - 000 shocks) Head tightening torque Plastic head (nut). N.m (± 0.) /. lb.in (±.) Metal head (base screw) 0. N.m (max.) /. lb.in (max 0.) Radio transmission specifications Frequency GHz. Protocol ZigBee Green Power compatible (transmitter and receiver can work with other ZigBee Green Power products) Range ft (m) Approx. (00) (transmitter and receiver in free space) Approx. () (transmitter in a plastic box type XALD and receiver in a metal enclosure) Approx. (0) (transmitter in plastic box type XALD, receiver in a metal enclosure and use of an external antenna) Transmission power mw Activation time ms Transmission time ms < Type Conforming to EN 0-- Type III. - Equipment Class Conforming to EN 0-- Class. - Equipment Category Conforming to EN 00-0-... - Temperature F ( C) Category : - to (- 0 to + ) Electromagnetic immunity and emissions Resistance to electrostatic discharges Conforming to IEC 000-- kv : on insulating parts (in free air) : on metal parts (contact) Resistance to electromagnetic fields Conforming to EN/IEC 0-- and IEC 000-- Conforming to IEC 000--, EN 0-- and EN 0-- Radiated emissions Conforming to EN 00-0- and EN 00-0- V/m 0: for 0 MHz to,000 MHz V/m : for 0 MHz to,00 MHz and distance ft (0 m) Compliant Introduction: page Catalog numbers: page Dimensions, wiring diagrams: page 0

Specifications (continued) Specifications of receiver for wireless and batteryless push Environment specifications Conforming to standards Receiver EN/IEC 0-, EN/IEC 0--, UL 0, CSA C- n, IEC 000--, IEC 000--, IEC 000--, IEC 000--, IEC 000--, IEC 000-- Transmitter/receiver system e: R&TTE //EC, BT 00//EC, EMC 00/0/EC Radiofrequency EN00-0-, EN00-0-, FCC part., RSS0, ANATEL (resolution 0), SRRC, EMC: EN0--, EN0-- Product certifications and radio agreements Ambient air temperature around the device Permissible relative humidity Vibration resistance conforming to IEC 00-- Shock resistance conforming to IEC 00-- Storage F ( C) - 0 to + (- 0 to + 0) Operation F ( C) - to + (- to + ) Frequency: to. Hz in (mm) ± 0. (±.) Frequency:. to 0 Hz gn Half sine wave acceleration: ms gn 0 UL, FCC (USA), CSA, RSS (Canada), C-Tick (Australia), GOST (Russia), ANATEL (Brazil), SRRC (China), e (Europe) + 0 % RH at + C (without condensation) Repetitive shocks resistance Conforming to IEC 00-- gn 0 (duration: ms - 000 shocks) Degree of protection Conforming to IEC 0 IP 0 Degree of pollution Conforming to IEC 0- Housing material Self-extinguishing plastic Mounting position without Any position derating (temperature) Mounting On rail conforming to EN/IEC 0 On mounting plate Electrical specifications Overvoltage category Conforming to IEC 0- II (AC/DC receiver), III (DC receiver) Insulation resistance Conforming to NFC 000 > 00 M c 00 V Rated insulation voltage Conforming to IEC 0- V 0 (receivers with relay outputs), < 0 (relay with PNP outputs) Insulation test voltage conforming to EN/IEC 0-- Cabling Maximum c.s.a. conforming to EN/IEC 0- Dielectric test Hz/KV AC/DC receiver: 0 /. ( minute) DC receiver: 0 / ( minute) Surge kv DC receiver: Uimp 0. (. / 0 μs) AC/DC receiver: Uimp (. / 0 μs) Solid cable without cable end mm conductor: 0. to. (AWG to AWG ) conductors: 0. to. (AWG to AWG ) Flexible cable with cable end mm conductor: 0. to (AWG to AWG ) conductors: 0. to. (AWG to AWG ) Tightening torque Conforming to EN/IEC 0-0. N.m/. Lbf.In Power ON indicator Green LED Output indicators Green LED (relay outputs and PNP outputs ) Received signal strength Green LED: optimum reception Yellow LED: acceptable reception Supply specifications Receiver type ZBRRC Receiver included in packs ZBRRA XBRFB0, XBRFB0 and XBRMB0 Supply voltage Ue V c (+ 0/- %) a/c to 0 (± 0 %) Frequency Of the power supply circuit Hz 0/0 ± 0 % Galvanic isolation Power supply/output Yes Maximum power drawn W 0. 0. Short-circuit protection Fast-blow fuse 00 ma Fast-blow fuse ma Fast-blow fuse 00 ma Immunity to microbreaks ms (total output current 00 ma) Conforming to IEC 000-- 0 (total output current 00 ma) Electromagnetic immunity and emissions Resistance to electrostatic discharges Resistance to electromagnetic fields Resistance to fast transients Hybrid surge withstand conforming to IEC 000-- Resistance to conducted disturbance Emissions Conforming to IEC 000-- kv : on insulating parts (in free air) : on metal parts (contact) Conforming to EN/IEC 0-- V/m 0: for 0 MHz to,000 MHz and IEC 000-- Conforming to IEC 000--, V/m : for 0 MHz to,00 MHz and distance ft (0 m) EN 0-- and EN 0-- Conforming to IEC 000-- kv (PNP output wires) (power supply wires and relay wires) (power supply wires) Differential mode kv 0. Common mode kv Conforming to IEC 000-- V 0 Conducted emissions conforming to EN 00--, EN 00-- Radiated emissions conforming to EN 00-0-, EN 00-0- As per class B method CISPR Compliant 0

Specifications (continued) Specifications of wireless and batteryless push (continued) Radio transmission specifications Receiver type ZBRRC ZBRRA Receiver included in packs XBRFB0, XBRFB0 and XBRMB0 Frequency GHz. Protocol ZigBee Green Power compatible (transmitter and receiver can work with other ZigBee Green Power products) Range ft (m) Approx. (00) (transmitter and receiver in free space) Approx. () (transmitter in a plastic box type XALD and receiver in a metal enclosure) Approx. (0) (transmitter in a plastic box type XALD, receiver in a metal enclosure and use of an external antenna) External antenna To increase the range or to get round an obstacle Response time ms < 0 after the transmitter "clicks" Number of transmitter ID codes that can be stored Type Conforming to EN 0--. - Equipment Class Conforming to EN 0--. - Equipment Reliability Conforming to EN 00 0-.. - Reliability Temperature Conforming to EN 00 0-... - Temperature Output specifications Output type Output function max. per receiver or max. per output (example on -output receiver: /0, /..) Type III Class Category F ( C) Category I: - to + (- 0 to + ) PNP outputs 00 ma/ V Monostable (00 ms ± %) relay outputs type RT A relay output type RT A Monostable (00 ms ± %). Programmable to bistable or Start/Stop Monostable (00 ms ± %) Nominal current Ie conforming to EN/IEC 0-- and UL 0 / CSA C- n DC supply conforming to EN/IEC 0-- DC supply conforming to UL 0 / CSA C- n A 0. / V DC A / V DC AC supply conforming to EN/IEC 0-- A. / 0 V AC / 0 V AC AC supply conforming to UL 0 / CSA C- n A / 0 V AC Voltage drop V < Maximum switching voltage V a/c 0 Nominal breaking capacity Minimum current Ith Conforming to EN/IEC 0-- ma 0 / c V. W (0. A x V DC) per output 0 VA ( A x 0 V AC) W (0. A x V DC) Maximum current A Electrical durability x 0 operating cycles Mechanical durability 0 x 0 operating cycles Maximum operating rate Hz Utilization categories Conforming to EN/IEC 0-- DC AC: B00 DC 0 Introduction: page Catalog numbers: page Dimensions, wiring diagrams: page 0

Specifications (continued) Specifications of external antenna for wireless and batteryless push - Works with transmitter(s) and receiver(s) Environment specifications Conforming to standards Antenna EN/IEC 0-, EN/IEC 0--, UL 0, CSA C- n, IEC 000--, IEC 000--, IEC 000--, IEC 000--, IEC 000--, IEC 000-- Transmitter /antenna / receiver system e: R&TTE //EC, BT 00//EC, EMC 00/0/EC Radiofrequency EN00-0-, EN00-0-, FCC part., RSS0, ANATEL (resolution 0), SRRC, EMC: EN0--, EN0-- Product certifications and radio agreements Ambient air temperature around the device UL, FCC (USA), CSA, RSS (Canada), C-Tick (Australia), GOST (Russia), ANATEL (Brazil), SRRC (China), e (Europe) Storage F ( C) - 0 to + (- 0 to + 0) Operation F ( C) - to + (- to + ) Electric shock protection Conforming to IEC 0 Class II Permissible relative humidity + 0 % RH at + F (+ C) (without condensation) Vibration resistance conforming to IEC 00-- Frequency: 0 to Hz in (mm) ± 0.0 (± 0.) Frequency: to 0 Hz gn Shock resistance Conforming to IEC 00-- Half sine wave acceleration: ms / gn Repetitive shocks resistance Conforming to IEC 00-- gn (duration: ms -,000 shocks) Degree of protection Conforming to IEC 0, UL/CSA IP - type Degree of pollution Conforming to IEC 0- Overvoltage category Conforming to IEC 0- III Insulation resistance Conforming to NFC 000 > 00 MΩ, c 00 V Rated insulation voltage Conforming to IEC 0- V 0 Insulation test voltage conforming to EN/IEC 0-- Dielectric test Hz/KV 0 / ( minute) Surge kv Uimp (. / 0 μs) Cabling (flexible cable) Conforming to EN/IEC 0- ft (m) () ( x 0. mm ) Screw tightening torque Conforming to EN/IEC 0-0. ± 0. Nm /. ± 0. Lb.-In Housing material Self-extinguishing plastic Indication Power ON green LED Transmission/reception green LEDs at 0 Mounting position See instructions for assembly Supply specifications Supply voltage Ue V a/c to 0 (± 0 %) Frequency Of the power supply circuit Hz 0/0 ± 0 % Maximum power drawn W. Short-circuit protection ma 00 with fast-blow fuse 00 ma Resistance to microbreaks Conforming to IEC 000-- Electromagnetic immunity and emissions Resistance to electrostatic discharges Conforming to IEC 000-- kv : on insulating parts (in free air) : on metal parts (contact) Resistance to electromagnetic fields Conforming to EN/IEC 0-- and IEC 000-- Conforming to IEC 000--, EN 0-- and EN 0-- V/m 0: for 0 MHz to,000 MHz V/m : for 0 MHz to,00 MHz and distance ft (0 m) Resistance to fast transients Conforming to IEC 000-- kv Hybrid surge withstand Differential mode kv conforming to IEC 000-- Common mode kv Resistance to conducted Conforming to IEC 000-- V 0 disturbance Emissions Conducted emissions conforming As per class B method CISPR to EN 00--, EN 00-- Radiated emissions conforming to EN 00-0-, EN 00-0- Compliant Radio transmission specifications Frequency GHz. Protocol ZigBee Green Power compatible (transmitter and receiver can work with other ZigBee Green Power products) Range ft (m) Approx. ft (0 m) (transmitter in a plastic box type XALD, receiver in a metal enclosure and use of an external antenna) Transmission power mw < Type Conforming to EN 0-- Type III. - Equipment Class Conforming to EN 0-- Class. - Equipment Reliability Conforming to EN 00-0- Category.. - Reliability Temperature Conforming to EN 00-0-... - Temperature F ( C) Category I: - to + (- 0 to + ) 0

Catalog numbers Ready-to-use packs () Description Transmitter type Voltage receiver Packs comprising: - wireless and batteryless push assembled on mounting collar, - receiver The push and receiver are factory-paired + Ø mm plastic head + set of 0 different colored caps ( cap to be selected and fi tted) + Ø mm metallic head + set of 0 different colored caps ( cap to be selected and fi tted) V a/c to 0 Receiver type Programmable receiver equipped with: - relay outputs type RT A (), - s (scroll-through, OK) - indicating LEDs (power ON, outputs, signal strength) Catalog number Weight oz (kg) XBRFA0. (0.0) XBRFA0. (0.) XBRFA0 + Ø mm plastic head + black cap + Ø mm metallic head + black cap c Non-programmable XBRFB0. (0.0) receiver: - with relay output type RT A () - without push - without indicating XBRFB0. (0.) LED 0 ZBRT ZBRZA0 ZBRTA Introduction: page Packs comprising: - wireless and batteryless push assembled on mounting collar, in handy box (), - receiver The push and receiver are factory-paired + Ø mm plastic head mounted in a handy box + set of 0 different colored caps ( cap to be selected and fi tted) + Ø mm metallic head mounted in a handy box + black cap a/c to 0 c Programmable receiver equipped with: - relay outputs type RT A (), - s (scroll-through, OK) - indicating LEDs (power ON, outputs, signal strength) XBRMA0. (0.0) Non-programmable XBRMB0. (0.0) receiver: - with relay output type RT A () - without push - without indicating LED Transmitter components for wireless and batteryless push Description Type of push Cap color Catalog number Weight oz (kg) Transmitter for wireless and ZBRT 0. (0.0) batteryless push () () Spring return push heads for transmitter ZBRT s including: - a transmitter fitted with mounting collar - a spring return push head with clipped-in cap () Plastic Without cap () ZBRZA0 0. (0.0) Metal Without cap () ZBRZA0.0 (0.00) Plastic White ZBRTA. (0.0) Black ZBRTA. (0.0) Green ZBRTA. (0.0) Green background with white I ZBRTA. (0.0) Red ZBRTA. (0.0) Red background with white O ZBRTA. (0.0) Yellow ZBRTA. (0.0) Blue ZBRTA. (0.0) Metal White ZBRTA.00 (0.0) Black ZBRTA.00 (0.0) Green ZBRTA.00 (0.0) Green background with white I ZBRTA.00 (0.0) Red ZBRTA.00 (0.0) Red background with white O ZBRTA.00 (0.0) Yellow ZBRTA.00 (0.0) Blue ZBRTA.00 (0.0) () and receiver, factory-paired. () Supplied with output function set to monostable. Outputs programmable to bistable and Start-Stop. () Non-programmable monostable output function. () Supplied with a magnet to be stuck on by the customer. () Mounting collar ZBAZ00 (plastic) or ZBBZ00 (metal) to be ordered separately. () Only heads ZBRZA0 and ZBRZA0 are mechanically compatible. () Cap to be ordered separately: see following page. () This cap is fi tted by Schneider Electric and cannot be removed (risk of damage). Specifi cations: page Dimensions, wiring diagrams: page 0

Catalog numbers (continued) ZBRRA ZBA ZBA ZBA ZBA Programmable receivers Description Output type Receiver voltage V Programmable receivers equipped with: - s (scroll through, confi rm) - indicating LEDs (power ON, outputs, signal strength) Catalog number Weight oz (kg) PNP outputs, 00 ma / V c ZBRRC. (0.0) relay outputs type RT A () Accessories Caps for Harmony push heads ZBRZA0 and ZBRZA0 Description Background color Marking Sold in lots of a/c to 0 ZBRRA. (0.0) Catalog number Weight oz (kg) Sets of 0 different colored White Without 0 ZBA 0. (0.00) caps with identical marking () I (black) 0 ZBA 0. (0.00) A (black) 0 ZBA 0. (0.00) + (black) 0 ZBA 0. (0.00) Black Without 0 ZBA 0. (0.00) O (white) 0 ZBA 0. (0.00) + (white) 0 ZBA 0. (0.00) R (white) 0 ZBA 0. (0.00) I (white) 0 ZBA 0. (0.00) Green Without 0 ZBA 0. (0.00) I (white) 0 ZBA 0. (0.00) + (white) 0 ZBA 0. (0.00) Z white 0 ZBA 0. (0.00) II (white) 0 ZBA 0. (0.00) Red Without 0 ZBA 0. (0.00) O (white) 0 ZBA 0. (0.00) Yellow Without 0 ZBA 0. (0.00) Blue Without 0 ZBA 0. (0.00) Set of 0 different colored caps with different markings () White, black, green, red, yellow, blue, white I on green background, black I on white background, white O on red background, white O on black background 0 ZBA 0. (0.00) ZBRM0 XALD0 Boxes for wireless and batteryless push Product Application Description Sold in lots of Catalog number Weight oz (kg) Handy box, plastic, empty () () For mobile wireless and batteryless push cut-out ZBRM0. (0.00) Empty plastic boxes for For fi xed or on-board wireless wireless and batteryless push and batteryless push s () Accessories External antenna () Between transmitter and receiver Used to increase the range and/or get round obstacles cut-out XALD0.0 (0.) cut-outs XALD0. (0.) a/c to 0 V - m cable - power-on LED - LEDs reception/transmission ZBRA.0 (0.00) Mounting collar Plastic 0 ZBAZ00. (0.0) Metal 0 ZBBZ00. (0.0) Legend plate,.0 x 0. in ( x mm), for engraving For sticking onto handy box ZBRM0 Self-adhesive, blank, black background 0 ZBY00T 0. (0.00) ZBRA () Supplied with output function set to monostable Outputs programmable to bistable and Start-Stop. () Cap can be clipped-in at 0 steps, through 0. () Cannot be used for wired contacts (no cable gland outlet). () Supplied with a magnet to be stuck on by the customer. () Box equipped with cable gland outlets, compatible with Harmony ZB push heads. () Not wired to the receiver. 0

Dimensions Dimensions (mm) - Transmitter ZBRTAppp, with plastic push and cap ZBRTAppp, with metal push and cap,, e 0 e 0 e: panel thickness to mm e: panel thickness to mm ZBRM0, Plastic handy box for mobile use 0 Ø 00. ().. () () Ø. Ø. () XALD0, Plastic box, single-hole for fixed or on-board installation XALD0, Plastic box, -hole for fixed or on-board installation () () xø. () () xø. () Location for ZBY00T legend. () Location for magnet to be stuck on by the customer. Non-programmable receiver Receiver contained in packs XBRFB0, XBRFB0 and XBRMB0 0.. () knock-outs for Pg. cable gland, maximum capacity mm. () Knock-out for wire routing, maximum capacity mm. Programmable receivers 0 0 Receivers ZBRRp (contained in packs XBRFA0, XBRFA0 and XBRMA0) 0.. 0 00. 0 00. x Ø x Ø External antenna ZBRA () () () 0 () With seal. () Radial cable route. Ø Ø. () () Axial cable route. Introduction: page 0 Specifi cations: page Catalog numbers: page

Wiring diagrams Wiring diagrams Non-programmable receiver Receiver contained in packs XBRFB0 and XBRMB0 0 V VDC () + - VDC () () ma fast-blow fuse. () Imax A. Programmable receivers Receiver ZBRRA (contained in packs XBRFA0, XBRFA0 and XBRMA0) Receiver ZBRRC N / 0 V to 0 VAC/DC () L/+ N/- to 0 VAC/DC 0 V VDC () + - VDC PWR Q Q PWR Q Q Q Q OK OK () Q Q Q () L L L Q L () () 00 ma fast-blow fuse. () Imax A. External antenna ZBRA () 00 ma fast-blow fuse. () Imax 00 ma () Imax 00 ma. m N / 0 V to 0 Vac/dc () 0. mm² Ø. () 00 ma fast-blow fuse. 0

Schneider Electric Industries SAS Schneider Electric USA Inc. Head Offi ce 00, rue Knightdale Joseph Monier Blvd. Knightdale, F-00 Rueil-Malmaison NC Tel: France -- Waterman Avenue Toronto, Ontario MB Y Tel: --00 www.schneider-electric.com http://www.schneider-electric.us/ The information provided in this documentation contains general descriptions and/or technical characteristics The information of provided the performance in this documentation of the products contains contained general herein. descriptions This documentation and/or technical is not intended characteristics as a substitute of the performance for and is not of the to be products used for contained determining herein. suitability This documentation or reliability of these is not products intended as for a specifi substitute c user for applications. and is not to It be is used the duty for of determining any such user suitability or integrator or reliability to perform of these the appropriate products for and specifi complete c user applications. risk analysis, It evaluation is the duty and of any testing such of user the or products integrator with to respect perform to the the relevant appropriate specifi and c complete application risk or analysis, use thereof. evaluation Neither and Schneider testing Electric of the products nor any with of its respect affi liates to or the relevant subsidiaries specifi shall c application be responsible or use or thereof. liable for Neither misuse Schneider of the information Electric nor contained any of its herein. affi liates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Design: Please note: Schneider not all Electric parts listed in this catalog are available in all countries. Photos: Schneider Electric Printed Design: by: Schneider Electric Photos: Schneider Electric 0 Schneider Electric. All rights reserved. 0/0