ST 3000 Smart Transmitter

Similar documents
LGP Design. Can be ordered separately see specification 34-ST-03-55

Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

URV LRV. Smart Field Communicator. Can be ordered separately see specification 34-ST-03-55

URV. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

ITEM. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

ITEM. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

Smart Field Communicator SET URV ITEM. Can be ordered separately see specification 34-ST-03-55

LGP Design. Can be ordered separately see specification 34-ST-03-55

SET. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

ST 3000 Smart Transmitter Series 900 Remote Diaphragm Seals Models. Specification and Model Selection Guide. Introduction 34-ST /2002

ST 3000 Smart Transmitter Series 900 Remote Diaphragm Seals Models. Specification and Model Selection Guide. Introduction 34-ST /04

ST 3000 Smart Transmitter Series 100 Gauge Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /04

Specification and Model Selection Guide. Introduction 34-ST /04

ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /24/06

ST 3000 Smart Transmitter Series 100 Remote Diaphragm Seals Models. Specification and Model Selection Guide. Introduction 34-ST /04

LGP Design. Can be ordered separately see specification 34-ST-03-55

SFC Smart Field Communicator Model STS103. Specification 34-ST /24/06. Description. Function. Page 1 of 5

ST 3000 Fieldbus Transmitter Series 100 Models

Wireless Transmitter Gauge Pressure Models Series XYR 6000 Specifications

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Wireless Pressure Transmitter Differential Pressure Models Series XYR 6000 Specifications

Specification and Model Selection Guide 34-ST /2003

Specification and Model Selection Guide. Introduction 34-XY /13/07

XYR 6000 Wireless Transmitter Absolute Pressure Model. Specification and Model Selection Guide. Introduction 34-XY /13/07

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

PAD - Heavy Duty Differential Pressure Trasmitter

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

SmartLine. STR800 SmartLine Remote Diaphragm Seals Specification 34-ST Technical Information. Introduction

Wireless Transmitter Series XYR 6000 Absolute Pressure Model STAW94L 0 to 500 psia 0 to 35 bara Specifications

XYR 6000 Wireless High Level Analog Input Transmitter Model STIW600 0 to 5 Volts 1 to 5 Volts 0 to 20 ma 4 to 20 ma

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

Specification and Model Selection Guide. Introduction 34-XY /14/07. Figure 1 XYR6000 Temperature Transmitters

ST 3000 Smart Transmitter Series 100 Flange Mounted Liquid Level Models. Specification and Model Selection Guide. Introduction 34-ST /08

General Specifications

Rosemount 3101, 3102, and 3105

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

Smart Pressure Transmitter

A New Generation of Pressure Transmitters

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610f

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Field IT 2600T Series Pressure Transmitters

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

General Specifications

Specification and Model Selection Guide. Introduction 34-ST /07

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

A New Generation of Pressure Transmitters

SmartLine Non-Contact Radar Level Meter Technical Datasheet. Specification. The Universal Radar Solution. Highlights. Industries.

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

PTG series Smart Pressure Transmitter

Specifications. Range 5. ±0.075% of span. URL % of Span ± ±0.04% of span. Ranges 2-4. ±0.04% of span

Rosemount 2088 Absolute and Gage Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE FROM THE INDUSTRY LEADERS

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Accutech DP20. Wireless differential pressure field unit

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

Wireless Multi Discrete Input Transmitter Series XYR 6000, Model STXW500 Specifications

11A Series Absolute Pressure Transmitters

Wireless Base Radio. Wireless Transmitters

Kotron Model 82 CE RF Level Transmitter

DREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /08

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Electro-Magnetic Flowmeters COPA-XE

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

D E S C R I P T I O N F E A T U R E S A P P L I C A T I O N S. The Enhanced Jupiter Magnetostrictive level transmitter

STT 3000 Smart Temperature Transmitter

OPTIFLUX 5000 Technical Datasheet

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

FIELD DEVICES PRESSURE

Echotel Model 910 Ultrasonic Level Switch

Level Measurement Continuous level measurement Radar transmitters

FIELD DEVICES PRESSURE

OPTIMASS 1000 Technical Datasheet

ST 3000 Smart Transmitter Series 900 Absolute Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /07

KFS. Flap-type flow meter. Design and range of application

Compact Orifice Flow Meter

I/A Series Electronic Pressure Transmitters with 4 to 20 ma Analog Output for Absolute and Gauge Pressure Measurement

DRS390 High stability, flange mounting

Smart Displacer Level (Interface) Transmitter DLT100 Series

IAP10/IGP10 TRANSMITTER STRUCTURE CODES 52, 53, 60-63, D5, D6, S5, S6, SH, AND SJ

General Specifications

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

OPTIFLUX 5000 Technical Datasheet

Echotel Trident 91S/92S Ultrasonic Level Switches

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

XYR 5000 Wireless Temperature Transmitters Model WT530 Specifications - Europe

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

FCX. Series AII & AIIe Electronic Transmitters. Barton

SmartLine Wireless Pressure Gauge Transmitter Specification

Magnetostrictive Level Transmitter

IP26 Series Current to Pneumatic Converter

Series Smart Pressure Transmitter

Transcription:

ST 3000 Smart Transmitter Series 900 Remote Diaphragm Seals Models STR93D 0 to 100 psid 0 to 7 bar STR94G 0 to 500 psig 0 to 35 bar 11/98 Specification and Model Selection Guide Function Honeywell s ST 3000 Series 900 Transmitters with Remote Diaphragm Seals bring proven smart technology to differential and gauge pressure measurement applications involving a variety of difficult process mediums. They measure pressure through remote seals and transmit an output signal proportional to the measured variable in either an analog 4-20 ma format or in a digital DE protocol format for direct digital integration with our TDC 3000 X control system. An optional electronics module is available for the Series 900 that provides HART ¹ Protocol compatibility. A future protocol option will let you use these transmitters in FOUNDATION Fieldbus² networks. In the standard transmitter you easily select the analog or digital transmission format through the Smart Field Communicator (SFC ) which is the common hand-held operator interface for our DE-based Smartline Transmitters. All configuration, operation, and communications functions are under the control of the ST 3000 Smart Transmitter s microprocessor and are accessible through the SFC. Series 900 Transmitters with Remote Diaphragm Seals eliminate piping the process to the transmitter. Armored, Stainless Steel capillary tubing connects the seals to the transmitter s meter body. The remote seals come in numerous styles to meet a variety of process connections. TAG No. SFC WORKING... Can be ordered separately see specification 34-ST-03-55 ID CONF LRV 0% MENU ITEM Smart Field Communicator DAMP UNITS URV 100% SET OUT- PUT NEXT STAT PREV 7 8 9 SPAN 4 5 6 1 2 3 0. NUM/ ALPHA SHIFT COR- RECT +/- CLR (NO) ENTER (YES) Remote Diaphragm Seals Transmitter Model STR93D Figure 1 ST 3000 transmitter with remote diaphragm seals ¹ HART is a registered trademark of the Hart Communication Foundation. ² FOUNDATION Fieldbus is a trademark of the Fieldbus Foundation. 24271 Industrial Automation and Control, 16404 N. Black Canyon Highway, Phoenix, AZ 85023 Printed in U.S.A. Copyright 1998 Honeywell Inc.

Page 2 Transmitters with remote seals are ideal for Sanitary applications and when the process medium: is a slurry or has suspended solids that may clog the instrument line, might freeze or solidify due to ambient or process temperature changes, is corrosive, or has a high temperature. Features Choice of remote seal styles to match varying process interface requirements. Two models cover wide range of differential and gauge pressure measurement applications. Direct digital integration with TDC 3000 X system provides local measurement accuracy to the system level without adding typical A/D and D/A converter inaccuracies. Unique piezoresistive sensor automatically compensates input for temperature and static pressure for differential pressure measurements only. Added smart features include configuring lower and upper range values, simulating accurate analog output, and selecting preprogrammed engineering units for display. Smart transmitter capabilities with local or remote interfacing means significant manpower efficiency improvements in commissioning, start-up, and ongoing maintenance functions. Description The ST 3000 transmitter can replace any 4 to 20 milliampere output transmitter in use today, and operates over a standard two-wire system. The measuring means is a piezoresistive sensor which actually contains three sensors in one. It contains a pressure sensor, a temperature sensor, and a static pressure sensor used for differential pressure measurements only. Microprocessor-based electronics provide higher span-turndown ratio, improved temperature and pressure compensation as required, and improved accuracy. Like other Smartline Transmitters, the ST 3000 features two-way communication between the operator and the transmitter through our SFC. You can connect the SFC anywhere that you can access the transmitter signal lines, and it provides the capabilities of transmitter adjustments and diagnostics from remote locations, such as the control room. The transmitter s meter body and electronics housing resist shock, vibration, corrosion, and moisture. The electronics housing contains a compartment for the single-board electronics, which is isolated from an integral junction box. The singleboard electronics is replaceable and interchangeable with any other ST 3000 Series 900 or Series 100e model transmitter. Specifications Operating Conditions All Models Parameter Reference Condition (at zero static) Rated Condition Operative Limits Transportation and Storage C F C F C F C F Ambient Temperature 25 ±1 77 ±2-25 to 70-13 to 158-40 to 85-40 to 185-55 to 125-67 to 257 Process Interface Temperature 25 ±1 77 ±2 See Figure 2-55 to 125-67 to 257 Humidity %RH 10 to 55 0 to 100 0 to 100 0 to 100 Overpressure (Flange Rating) psi bar Vacuum Region, Minimum Pressure - mmhg absolute inh2o absolute Supply Voltage, Current, and Load Resistance 0 0 atmospheric atmospheric 750* 52* See Figure 2 750* 52* Voltage Range: 10.8 to 42.4 Vdc at terminals Current Range: 3.0 to 21.8 ma Load Resistance: 0 to 1440 ohms (as shown in Figure 3) * Or Seal rating, whichever is lower. See Model Selection Guide for Seal rating.

Page 3 Maximum Pressure Limited by Flange Rating of Seal 10000 9000 8000 7000 6000 5000 4000 3000 2000 Silicone DC704 30 to 450 F Silicone DC200-40 to 350 F 193 psig 1000 900 800 700 600 500 400 300 200 100 90 80 70 60 50 40 30 20 Pressure (mmhga) 10-100 Maximum Pressure Limited by Flange Rating of Seal CTFE 5 to 300 F Special High Vacuum Construction required. Consult STC. 1Atm 0 psig -14-40 5 25 30 175 350 450 psig 0 100 200 300 400 500 Process Temperature (Degrees F) -9 psig 10000 9000 8000 7000 6000 5000 4000 3000 2000 NEOBEE M-20 30 to 400 F Syltherm 800-40 to 600 F 193 psig 90 psig 1000 900 800 700 600 500 400 300 200 100 90 80 70 60 50 40 30 20 Pressure (mmhga) 10-100 -40 5 25 30 0 100 1Atm 0 psig -9 psig -14 175 450 550 psig 200 400 500 600 Process Temperature (Degrees F) 20335 Figure 2 ST 3000 Remote Seals operable limits for pressure versus temperature

Page 4 1440 1200 = Operating Area Loop Resistance (ohms) 800 650 450 250 NOTE: A minimum of 250 0hms of loop resistance is necessary to support communications. Loop resistance equals barrier resistance plus wire resistance plus receiver resistance. Also 45 volt operation is permitted if not an intrinsically safe installation. 0 10.8 16.28 20.63 25 28.3 37.0 42.4 Operating Voltage (Vdc) 21012 Figure 3 Supply voltage and loop resistance chart Performance Under Rated Conditions* - Model STR93D (0 to 100 psi/7 bar) Parameter Upper Range Limit Minimum Span psi bar psi bar Description 100 (Transmitter URL or maximum seal pressure rating, whichever is lower.) 7 0.9 0.063 Turndown Ratio 110 to 1 Zero Elevation and Suppression Accuracy (Reference Includes combined effects of linearity, hysteresis, and repeatability) Accuracy includes residual error after averaging successive readings. Combined Zero and Span Temperature Effect per 28 C (50 F) Specification doubles for 2-inch Sanitary Seals or for model with only one remote seal No limit except minimum span within ±100% URL. In Analog Mode: ±0.20% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (50 inh2o), accuracy equals: 50 inh2o ±0.10 + 0.10 span inh2o or ±0.10 + 0.10 125 mbar span mbar in % span In Digital Mode: ±0.175% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (50 inh2o), accuracy equals: 50 inh2o ±0.075 + 0.10 span inh2o or ±0.075 + 0.10 125 mbar span mbar In Analog Mode: ±1.5% of span. For URV below reference point (100 inh2o), effect equals: ±0.30 + 1.2 100 inh2o span inh2o or ±0.30 + 1.2 250 mbar span mbar In Digital Mode: ±1.475% of span. For URV below reference point (100 inh2o), effect equals: 100 inh2o ±0.275 + 1.2 span inh2o or ±0.275 + 1.2 250 mbar span mbar in % span in % span in % span *Performance specifications are based on reference conditions of 25 C (77 F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm.

Performance Under Rated Conditions* - Models STR94G (0 to 500 psi/35 bar) Parameter Upper Range Limit Minimum Span psi bar psi bar 500 35 20 1.4 Turndown Ratio 25 to 1 Zero Elevation and Suppression Accuracy (Reference Includes combined effects of linearity, hysteresis, and repeatability) Accuracy includes residual error after averaging successive readings. Combined Zero and Span Temperature Effect per 28 C (50 F) Description No limit except minimum span from absolute 0 (zero) to +100% URL. Page 5 In Analog Mode: ±0.10% of calibrated span or upper range value (URV), whichever is greater, terminal based. In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is greater, terminal based. In Analog Mode: ±2.2% of span. For URV below reference point (50 psi), effect equals: ±0.2 + 2.0 50 psi or ±0.2 + 2.0 span psi 3.5 bar in % span span bar In Digital Mode: ±2.175% of span For URV below reference point (50 psi), effect equals: ±0.175 + 2.0 50 psi span psi or ±0.175 + 2.0 3.5 bar span bar in % span *Performance specifications are based on reference conditions of 25 C (77 F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm. Performance Under Rated Conditions - General for all Models Parameter Description Output (two-wire) Supply Voltage Effect Damping Time Constant CE Conformity (Europe) Analog 4 to 20 ma or DE digital communications mode. Optional HART electronics module available. 0.005% span per volt. Adjustable from 0 to 32 seconds digital damping. 89/336/EEC, Electromagnetic Compatibility (EMC) Directive.

Page 6 Physical and Approval Bodies Parameter Description Process Interface Seal Barrier Diaphragm Seal Gasket Materials See Model Selection Guide for Material Options for desired Seal Type. 316L Stainless Steel, Monel, Hastelloy C, Tantalum Klinger C-4401 (non-asbestos) Grafoil Mounting Bracket Carbon Steel (zinc-plated) or Stainless Steel angle bracket or Carbon Steel flat bracket available. Fill Fluid (Meter Body) Silicone (DC 200) S.G. @ 25 C (77 F) = 0.94 CTFE (Chlorotrifluoroethylene) S.G. @ 25 C (77 F) = 1.89 Fill Fluid (Secondary)* Silicone (DC 200) S.G. @ 25 C (77 F) = 0.94 CTFE (Chlorotrifluoroethylene) S.G. @ 25 C (77 F) = 1.89 Silicone (DC 704) S.G. @ 25 C (77 F) = 1.07 Syltherm 800 S.G. @ 25 C (77 F) = 0.90 NEOBEE M-20 S.G. @ 25 C (77 F) = 0.93 Electronics Housing Epoxy-Polyester hybrid paint. Low-copper aluminum alloy. Meets NEMA 4X (watertight) and NEMA 7 (explosion proof) Capillary Tubing** Armored Stainless Steel or PVC Coated Armored Stainless Steel. Length: 5, 10, 15, 20, 25 and 35 feet (1.5, 3, 4.6, 6.1, 7.5 and 10.7m) (2 or 6 S.S. close-coupled nipple also available) Wiring Accepts up to 16 AWG (1.5 mm diameter) Mounting See Figure 4. Dimensions Net Weight See Figures 7 and 8 for transmitter dimensions. See Model Selection Guide for Seal dimensions Transmitter: 4.1 Kg (9 lbs). Total weight is dependent on seal type and capillary length. Approval Bodies Approved as explosion proof and intrinsically safe for use in Class I, Division 1, Groups A, B, C, D locations, and nonincendive for Class I, Division 2 Groups A, B, C, D locations. Approved EEx ia IIC T5 and EEx d IIC T6 per CENELEC standards; and Ex N II T5 per BS 6941. * See Figure 2 for Fill Fluid temperature limits. ** 2-inch Sanitary Seals are limited to 15 ft. (4.6 m) capillary length. Series 900 with HC (HART) Compatibility is self certified for Zone 2, T5, maximum 42V/22 ma.

Page 7 LP Side Maximum level H2 Fixed ref. leg Variable Head H1. Minimum level HP Side NOTE: Lower flange seal should not be mounted over 22 feet below the transmitter for silicone fill fluid (11 feet for CTFE fill fluid) with tank at one atmosphere. The combination of tank vacuum and high pressure capillary head effect should not exceed 9 psi vacuum (300 mmhg absolute). Consult Honeywell for installation of STR13D. 20339 Figure 4 Typical mounting arrangement for ST 3000 Transmitter with Remote Diaphragm Seals

Page 8 Application Data Liquid Level: Closed Tank Determine the minimum and maximum pressure differentials to be measured (Figure 5). Max Level LP PMin = (SGp x a) - (SGf x d) = LRV when HP at bottom of tank = URV when LP at bottom of tank Min Level b a HP PMax = (SGp x b) - (SGf x d) = URV when HP at bottom of tank = LRV when LP at bottom of tank Where: minimum level = 4mA maximum level = 20 ma Transmitter above datum Max Level b LP a = distance between bottom tap and minimum level Min Level a HP b = distance between bottom tap and maximum level Transmitter at datum d = distance between taps SGf = Specific Gravity of capillary fill fluid (See Page 6 for values.) Max Level LP SGp = Specific Gravity of process fluid Min Level b a HP Transmitter below datum 24253 Figure 5 Closed tank liquid level measurement distances

Page 9 Density or Interface Calculate the minimum and maximum pressure differentials to be measured (Figure 6). Pmin = (SGmin - SGf) x (d); minimum density, 4mA output LP Pmax = (SGmax - SGf) x (d); maximum density, 20mA output Where: d = distance between the taps SGmax = maximum Specific Gravity SGmin = minimum Specific Gravity HP 24257 SGf = Specific Gravity of capillary fill fluid (See Page 6 for values.) Figure 6 Density, direct acting transmitter configuration

Page 10 Reference Dimensions:millimeters inches With Smart meter 45.7 1.8 82.9 3.26 53.1 2.09 Without meter 94.9 3.74 65.1 2.56 Without meter Removal Clearance for All Caps with meter 3.6 0.14 Plug 135 5.32 55.3 2.18 23.5.925 Optional external ground Rotational Lock 67 2.64 Optional Meters LP seal omitted for clarity STR93D DP/I Remote Seal with Horizontal Pipe Mount 93.6 3.69 3.6 0.14 Plug 135 5.32 With Smart meter 45.7 1.8 82.9 3.26 53.1 2.09 Without meter 94.9 3.74 65.1 2.56 Without meter Removal Clearance for All Caps with meter Rotational Lock 55.3 2.18 Optional Meters Optional external ground 23.5.925 Seal omitted for clarity STR94G LGP/I Remote Seal with Horizontal Pipe Mount 24272 Figure 7 Approximate horizontal mounting dimensions for Remote Seal Transmitter.

Page 11 Reference Dimensions:millimeters Inches 45.7 1.8 With Smart meter 82.9 3.26 53.1 2.09 Without meter 94.9 3.74 65.1 2.56 Without meter Removal Clearance for All Caps with meter 3.6 0.14 Plug 135 5.32 Optional external ground 23.5.925 Seal omitted for clarity Rotational Lock 55.3 2.18 Optional Meters LP seal omitted for clarity 67 2.64 STR93D DP/I Remote Seal with Vertical Pipe Mount 93.6 3.69 3.6 0.14 Plug 135 5.32 55.3 2.18 With Smart meter 45.7 1.8 82.9 3.26 53.1 2.09 Without meter 94.9 3.74 65.1 2.56 Without meter Removal Clearance for All Caps with meter Rotational Lock Optional Meters 23.5.925 Optional external ground Seal omitted for clarity STR94G LGP/I Remote Seal with Vertical Pipe Mount 24273 Figure 8 Approximate vertical mounting dimensions for Remote Seal Transmitter

Page 12 Options Ordering Information Mounting Bracket The angle mounting bracket is available in either zinc-plated carbon steel or stainless steel and is suitable for horizontal or vertical mounting on a two inch (50 millimeter) pipe, as well as wall mounting. An optional flat mounting bracket is also available in carbon steel for two inch (50 millimeter) pipe mounting. Indicating Meter Two integral meter options are available. An analog meter (option ME) is available with a 0 to 100% linear scale. The Smart Meter (option SM) provides an LCD display for both analog and digital output and can be configured to display pressure in pre-selected engineering units. * Lightning Protection A terminal block with circuitry that protects the transmitter from transient surges induced by nearby lightning strikes is available. HART Protocol Compatibility (Option HC) An optional electronics module is available for the Series 900 that provides HART Protocol compatibility. Transmitters with the HART Option are compatible with the AMS System. (Contact your AMS Supplier if an upgrade is required.) Configuration of the HART Option transmitter is accomplished using a Universal HART Communicator. For full functionality the communicator must contain the Honeywell Device Description (DD). Contact your nearest Honeywell office or distributor for further information regarding this option. *NOTE: When used in conjunction with the HC Option the Smart Meter will display only 0 to 100%. Tagging (Option TG) Up to 30 characters can be added on the stainless steel nameplate mounted on the transmitter s electronics housing at no extra cost. Note that a separate nameplate on the meter body contains the serial number and body-related data. A stainless steel wired on tag with additional data of up to 4 lines of 28 characters is also available. The number of characters for tagging includes spaces. Transmitter Configuration (Option TC) The factory can configure the transmitter linear/square root extraction, damping time, LRV, URV and mode (analog/digital) and enter an ID tag of up to eight characters and scratchpad information as specified. Custom Calibration and ID in Memory (Option CC) The factory can calibrate any range within the scope of the transmitter s range and enter an ID tag of up to eight characters in the transmitter s memory. FOUNDATION Fieldbus (Future Option FF) Equips transmitter with FF protocol for use in 31.25 kbit/s FF networks. See document 34-ST-03-72 for additional information on ST 3000 Fieldbus transmitters. Specifications are subject to change without notice. (Note that specifications may differ slightly for transmitters manufactured before October 30, 1995.) Contact your nearest Honeywell sales office, or In the U.S.: Honeywell Industrial Automation & Control 16404 N. Black Canyon Highway Phoenix, AZ 85023 1-800-288-7491 In Canada: The Honeywell Centre 155 Gordon Baker Rd. North York, Ontario M2H 3N7 1-800-461-0013 In Latin America: Honeywell Inc. 480 Sawgrass Corporate Parkway, Suite 200 Sunrise, FL 33325 (954) 845-2600 In Europe: Honeywell PACE 1, Avenue du Bourget B-1140 Brussels, Belgium [32-2] 728-2111 In Asia: Honeywell Asia Pacific Inc. Room 3213-25 Sun Hung Kai Centre No. 30 Harbour Road Wanchai, Hong Kong 2829-8298 In the Pacific: Honeywell Limited 5 Thomas Holt Drive North Ryde NSW 2113 Australia (61 2) 9353 7000 Or, visit Honeywell on the World Wide Web at: http://www.honeywell.com

Page 13 Model Selection Guide 34-ST-16-34 Instructions Select the desired Key Number. The arrow to the right marks the selection available. Make one selection from each table, I and II, using the column below the proper arrow. Select as many Table III options as desired (if no options are desired, specify 00). A dot denotes unrestricted availability. A letter denotes restricted availability. Restrictions follow Table IV. Key Number I II III (Optional) IV - _ - -, + XXXX KEY NUMBER Selection Availability Description 0-25" to 0-2700" H2O/0-62.2 to 0-7000 mbar STR93D Body Rating*: 750 psi (51.7 bar) Compound Characterized 0-20" to 0-500 psig/0-1.4 to 0-35 bar STR94G Body Rating*: 500 psi (35 bar) * Remote seal system pressure rating is body rating or seal rating, whichever is less. TABLE I - METER BODY 1 Remote Seal (High Side) 1 Number of Seals 2 Remote Seals 2 1 Remote Seal (Low Side) 3 Fill Fluid Silicone (DC 200) _ 1 _ (Meter Body) CTFE _ 2 _ q q Construction Non-Wetted Adapter Head Material Standard Dual Head 316 St. St. A 316 St. St. for Close-Couple D y 316 St. St. A Standard Dual Head Carbon St. (zinc-plated) B 316 St. St. for Close-Couple D y

Page 14 Model Selection Guide, continued STR9 TABLE II - SEALS Selection 3D 4G Format for Seal Selection: Specify 12 characters Common Required Seal Note: The first 3 characters are common to all seals. When selecting required seal, you must specify only the 9 selections within the required seal. Silicone (DC 200) 1 _ Secondary CTFE 2 _ Fill Silicone (DC 704) 3 _ p p Neobee (M20) ** 4 _ Syltherm 800 *** 5 _ p p 5 feet 1.5 m _ A 10 feet 3.0 m _ B 15 feet 4.5 m SS Armor _ C 20 feet 6.1 m _ D 25 feet 7.5 m _ E Connection Capillary 35 feet 10.7 m _ F of Remote Length 5 feet 1.5 m _ G Seal to 10 feet 3.0 m PVC Coated _ H Meter Body 15 feet 4.5 m SS Armor _ J 20 feet 6.1 m _ K 25 feet 7.5 m _ L 35 feet 10.7 m _ M 2 inch long SS nipple close-coupled _ 2 z z 6 inch long SS nipple close-coupled _ 6 z z No Selection 0 _ Diaphragm Flange Flange Pressure Diameter Size Rating * ANSI Class 150 _ AFA Flush 3.5" 3" ANSI Class 300 _ AFC Flanged DIN DN80-PN40 _ AFM Seal Diaphragm Upper Insert 316L SS 316 St. St. AA Wetted Material Hastelloy C 316 St. St. AB Hastelloy C Hastelloy C AC Monel Monel AE Non-Wetted CS with Polyester 1 _ Material (upper) Powder Coating 316 St. St. 2 _ Bolts No Selection _ 0 Styles No Selection 0 _ Gasket No Selection _ 0 Table II, continued next page. * Standard facing 125-250 AARH RF (raised face) serrated surface finish. ** Limited vacuum availability. *** Minimum static pressure requirement. No vacuum allowed. See Specification Figure 2.

Page 15 Model Selection Guide, continued STR9 TABLE II - SEALS (continued) Selection 3D 4G Diaphragm Flange Flange Const. - See Diameter Size Pressure Spec. Figure Rating * 1" ANSI 150 2 _ BCA ANSI 300 2 _ BCC 2.4" 1-1/2" ANSI 150 2 _ BGA ANSI 300 2 _ BGC 2" ANSI 150 2 _ BDA ANSI 300 2 _ BDC 3" ANSI 150 2 _ BFA ANSI 300 2 _ BFC 1/2" ANSI 150 3 _ CAA t t 1" ANSI 150 3 _ CCA t t ANSI 300 3 _ CCC t t 2.9" 1-1/2" ANSI 150 2 _ CGA t t ANSI 300 2 _ CGC t t 2" ANSI 150 2 _ CDA t t ANSI 300 2 _ CDC t t 1/2" ANSI 150 3 _ DAA 1" ANSI 150 3 _ DCA ANSI 300 3 _ DCC Flush 1-1/2" ANSI 150 3 _ DGA Flanged 4.1" ANSI 300 3 _ DGC Seal with 2" ANSI 150 3 _ DDA Lower ANSI 300 2 _ DDC 3" ANSI 150 2 _ DFA ANSI 300 2 _ DFC Diaphragm Lower 316L SS 316 St. St. BA Wetted Material Hastelloy C 316 St. St. BB Hastelloy C Hastelloy C BC Monel Monel BE Tantalum 316 St. St. BF Tantalum Hastelloy C BG Non-Wetted Upper Upper Insert Material (upper, 316 St. St. 316 St. St. 4 _ upper insert) CS 316 St/ St. 5 _ Bolts No Selection _ 0 Without 1/4" NPT Flushing 0 _ Styles Connection With 1/4" NPT Flushing 7 _ Connection Gasket Klinger C-4401 _ K c c (non-asbestos) Grafoil _ G d d Table II, continued next page. * Standard facing 125-250 AARH RF (raised face) serrated finish.

Page 16 Model Selection Guide, continued STR9 TABLE II - SEALS (continued) Selection 3D 4G Diaphragm Flange Flange Pressure Diameter Size Rating * 2.9" 3" ANSI Class 150 _ EFA (2.85") (2.85" OD ANSI Class 300 _ EFC extension) DIN DN80-PN40 _ EFM Flange 4" ANSI Class 150 _ FGA Seal with 3.5" (3.70" OD ANSI Class 300 _ FGC Extended extension) DIN DN100-PN40 _ FGP Diaphragm Diaphragm Lower 316L SS 316 St. St. EA Wetted Material Hastelloy C 316 St. St. EB Hastelloy C Hastelloy C EC Non-Wetted CS with Polyester Powder 7 _ Material (flange) Coating Bolts No Selection _ 0 Extension 2" 2 _ Length 4" 4 _ 6" 6 _ Gasket No Selection _ 0 Diaphragm Flange Flange Pressure Rating** Diameter Size Dependent on customer flange 3.5" 3" ANSI Class 150/300/600 _ GFA Diaphragm Body Pancake 316L SS 316 St. St. GA Seal Wetted Material Hastelloy C 316 St. St. GB Hastelloy C Hastelloy C GC Monel Monel GE Non-Wetted No Selection 0 _ Material Bolts No Selection _ 0 Styles No Selection 0 _ Gasket No Selection _ 0 Table II, continued next page. * Standard facing 125-250 AARH RF (raised face) serrated finish. ** Caution: Maximum working pressure of STR93D transmitter is 750 psi and STR94G transmitter is 500 psig. Damage to sensor may result if pressure limit is exceeded.

Page 17 Model Selection Guide, continued STR9 TABLE II - SEALS (continued) Selection 3D 4G Diaphragm Flange Flange Pressure Diameter Size Rating Taylor 3.5" Wedge 750 psi _ HM0 v Chemical 5" O.D. Tee "Taylor" Diaphragm Lower Wedge Wetted Material 316L SS 316 St. St. HA Hastelloy C 316 St. St. HB Non-Wetted No Selection 0 _ Material Bolts No Selection _ 0 Styles No Selection 0 _ Gasket No Selection _ 0 Diaphragm Threaded Process Seal Pressure Diameter Connection Size Rating * (NPT Female) CS Bolts 304 SS Bolts 1/2" NPT _ JJG 2.4" 3/4" NPT _ JKG 1" NPT 2500 1250 _ JLG 1/2" NPT _ KJG 2.9" 3/4" NPT 2500 1250 _ KKG 1" NPT psi psi _ KLG 1/2" NPT _ LJG 4.1" 3/4" NPT 1500 750 _ LKG Seal with 1" NPT psi psi _ LLG Threaded Diaphragm Lower Process 316L SS CS JA Connection Wetted Material 316L SS 316 St. St. JB Hastelloy C 316 St. St. JC Hastelloy C Hastelloy C JD Monel Monel JE Tantalum 316 St. St. JF Tantalum Hastelloy C. JG Non-Wetted CS with Polyester Material Powder Coating A _ (upper) Stainless Steel C _ w w Bolts C.S. _ C 304 St. St. _ D Styles W/O Flushing Connection A _ With Flushing Connection F _ Gasket Klinger C-4401 _ K c c (non-asbestos) Grafoil _ G d d Table II, continued next page. * Caution: Maximum working pressure of STR93D transmitter is 750 psi and STR94G transmitter is 500 psig. Damage to sensor may result if pressure limit is exceeded.

Page 18 Model Selection Guide, continued STR9 TABLE II - SEALS (continued) Selection 3D 4G Diaphragm Flange Pressure Rating Diameter Size 1.9" 2" Customer clamp rating _ MD0 s 2.4" 2-1/2" or 600 psi, whichever _ NE0 2.9" 3" is less _ PF0 4.1" 4" _ QG0 Sanitary Diaphragm Body Seal Wetted Material 316L SS 316 St. St. N A Non-Wetted No Selection 0 _ Material Bolts No Selection _ 0 Styles Tri-Clover Tri-Clamp 0 _ Gasket No Selection _ 0 Diaphragm Size and Seal Pressure Rating * * Diameter Bolt C.S. Bolts 304 St. St. Pattern Bolts for 3" 2.4" pipe- _ RPK Conoflow 1250 psi 1250 psi or 4" or _ RQK larger pipe- Conoflow Saddle Diaphragm Lower Housing Seal 316L SS C. S. RA 316L SS 316 St. St. RB Wetted Material Hastelloy C 316 St. St. RC 316 LSS N/A-Body Only SB Hastelloy C N/A-Body Only SC Non-Wetted Body Bolts * Material C. S. C. S. B _ 316 St. St. 304 St. St. C _ No Selection _ 0 Styles No Selection 0 _ Gasket No Selection _ 0 Note: All sanitary seals have dairy grade 3A approval. * Bolts are not included with "Body only" selection. ** Caution: Maximum working pressure of STR93D transmitter is 750 psi and STR94G transmitter is 500 psig. Damage to sensor may result if pressure limit is exceeded.

Page 19 Model Selection Guide, continued STR9 TABLE III - OPTIONS Selection 3D 4G None 00 Mounting Bracket - Carbon Steel MB Mounting Bracket - ST. ST. SB b Flat Mounting Bracket FB 316 ST.ST. Electronics Housing with M20 Conduit Connections SH m m 1/2" NPT to M20 316SS Conduit Adapter (BASEEFA EEx d IIC) A1 n n b 1/2" NPT to 3/4" NPT 316 SS Conduit Adapter A2 u u Lightning Protection LP Analog Meter (0-100 Even 0-10 Square Root) ME b Smart Meter SM A286SS (NACE) Bolts and 302/304SS (NACE) Nuts for Heads CR Stainless Steel Customer Wired-On Tag TG (4 lines, 28 characters per line, customer supplied information) Stainless Steel Customer Wired-On Tag (blank) TB Custom Calibration and I.D. in Memory CC Transmitter Configuration TC Write Protection WP Clean Transmitter for Oxygen or Chlorine Service with Certificate 0X h h Over-Pressure Leak Test with F3392 Certificate TP Local Zero and Span ZS b HART Protocol Compatible Electronics HC x x Calibration Test Report and Certificate of Conformance (F3399) F1 b Certificate of Conformance (F3391) F3 Certificate of Origin (F0195) F5 NACE Certificate (F0198) F7 o Additional Warranty - 1 year W1 Additional Warranty - 2 years W2 b Additional Warranty - 3 years W3 Additional Warranty - 4 years W4 Table III, continued next page.

Page 20 Model Selection Guide, continued STR9 TABLE III - OPTIONS (continued) Selection 3D 4G Approval Body Approval Type Location or Classification Explosion Proof Class I, Div. 1, Groups A,B,C,D Factory Dust Ignition Proof Class II, III Div. 1, Groups E,F,G Mutual Non-Incendive Class I, Div. 2, Groups A,B,C,D F1D3 Intrinsically Safe Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G Explosion Proof Class I, Div. 1, Groups B,C,D CSA Dust Ignition Proof Class II, III, Div. 1, Groups E,F,G C1C3 Intrinsically Safe Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G Zone 2 Self-Declared Ex II 3 GD T (1) X (Europe) per 94/9/EC (1) T4 at Tamb. 93 o C, T5 at Tamb. H2D5 (ATEX4) 80 o C, T6 at Tamb. 65 o C SA Intrinsically Safe Ex ia IIC T4 A0CA Non-Incendive Ex n IIC T6 (T4 with SM option) Flame Proof/ EEx d IIC T6 CENELEC Intrinsically Safe/ EEx ia IIC T5 E1D9 LCIE CENELEC Flame Proof/ EEx d IIC T6 CENELEC Intrinsically Safe/ EEx ia IIC T5 E1D8 f f CENELEC Flame Proof/ EEx d IIC T6 E1D3 CENELEC No hazardous location approvals 9X Explosion Proof Class I, Div. 1, Groups A,B,C,D Factory Dust Ignition Proof Class II, III Div. 1, Groups E,F,G Mutual Non-Incendive Class I, Div. 2, Groups A,B,C,D 1C Intrinsically Safe Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G Explosion Proof Class I, Div. 1, Groups B,C,D CSA Dust Ignition Proof Class II, III, Div. 1, Groups E,F,G 2J Intrinsically Safe Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G Zone 2 Self-Declared Ex II 3 GD T (1) X (Europe) per 94/9/EC (1) T4 at Tamb. 93 o C, T5 at Tamb. 3N (ATEX4) 80 o C, T6 at Tamb. 65 o C SA Intrinsically Safe Ex ia IIC T4 4H a a (Australia) Non-Incendive Ex n IIC T6 (T4 with SM option) Flame Proof Ex d IIC T6 Flame Proof/ EEx d IIC T6 3A CENELEC LCIE Intrinsically Safe/ EEx ia IIC T5 CENELEC Flame Proof/ EEx d IIC T6 3D CENELEC TABLE IV Factory Identification XXXX b

Page 21 Model Selection Guide, continued RESTRICTIONS Restriction Available Only With Not Available With Letter Table Selection Table Selection a Approval Body pending b Select only one option from this group c II BF, BG, JF, JG, d II BF, BG, JF, JG, f III HC h I, II _ 2 _ - 2 _ m III ZS, F1D3, C1C3 n III F1D3, C1C3 o III CR p II DC704 and Syltherm 800 fills and close-couple require SS seal upper. _ BCA 5 _, _ CAA 5 _, _ CCA 5 _, _ CCC 5 _, _ DAA 5 _, _ DCA 5 _, _ DCC 5 _, _ DGA 5 _, _ DGC 5 _, _ DDA 5 _, GE, A _ B _ q II 2, 4 s II _ A, _ B, _ C, _ G, _ H, _ J, _ 2, _ 6, u III F1D3, C1C3 v I 2 w II JA Restrictions, continued next page.

Page 22 Model Selection Guide, continued RESTRICTIONS - (continued) Restriction Available Only With Not Available With Letter Table Selection Table Selection x III A0CA, E1D9 y I 1, 3 III MB, SB, FB II _ 2 DC704 and Syltherm 800 _ 6 fills and close-couple require SS seal upper. _ BCA 5 _, _ CAA 5 _, _ CCA 5 _, _ CCC 5 _, _ DAA 5 _, _ DCA 5 _, _ DCC 5 _, _ DGA 5 _, _ DGC 5 _, _ DDA 5 _, GE, A _ B _ z I D Note: See 13:ST-27 for Published Specials with pricing. See 13:ST-29 and User s Manual for part numbers. See 13:ST-OE-9 for OMS Order Entry Information including TC, manuals, certificates, drawings and SPINS. See 13:ST-OD-1 for tagging, ID, Transmitter Configuration (TC) and calibration including factory default values. To request a quotation for a non-published "special", fax RFQ with Application Data Sheet (34-ST-18-01) to Marketing Applications.