A MEMS Based Visible-NIR Fourier Transform Microspectrometer

Similar documents
Out-of-plane translatory MEMS actuator with extraordinary large stroke for optical path length modulation in miniaturized FTIR spectrometers

Sensors and Actuators A: Physical

USER MANUAL VarioS-Microscanner-Demonstrators

Position encoding and closed loop control of MOEMS translatory actuators

Sensitivity Enhancement of Bimaterial MOEMS Thermal Imaging Sensor Array using 2-λ readout

A compact and portable IR Analyzer: Progress of a MOEMS FT-IR System for mid-ir Sensing

MICROMACHINED INTERFEROMETER FOR MEMS METROLOGY

BMC s heritage deformable mirror technology that uses hysteresis free electrostatic

Silicon photonic devices based on binary blazed gratings

Advanced Features of InfraTec Pyroelectric Detectors

Spatial-Phase-Shift Imaging Interferometry Using Spectrally Modulated White Light Source

Design and Analysis of Resonant Leaky-mode Broadband Reflectors

A novel tunable diode laser using volume holographic gratings

High-speed wavefront control using MEMS micromirrors T. G. Bifano and J. B. Stewart, Boston University [ ] Introduction

Supplementary Information

(12) United States Patent (10) Patent No.: US 7,733,493 B2. Urey et al. (45) Date of Patent: Jun. 8, 2010

Figure 1: Layout of the AVC scanning micromirror including layer structure and comb-offset view

Optical Characterization and Defect Inspection for 3D Stacked IC Technology

Imaging Fourier transform spectrometer

FRAUNHOFER INSTITUTE FOR PHOTONIC MICROSYSTEMS IPMS. Application Area. Quality of Life

Theory and Applications of Frequency Domain Laser Ultrasonics

A thin foil optical strain gage based on silicon-on-insulator microresonators

Micro-Mechanical Slit Positioning System as a Transmissive Spatial Light Modulator

SiGe based Grating Light Valves: A leap towards monolithic integration of MOEMS

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

High-Coherence Wavelength Swept Light Source

Adaptive Focal Plane Array - A Compact Spectral Imaging Sensor

Fiber-optic Michelson Interferometer Sensor Fabricated by Femtosecond Lasers

CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor

Single- Crystal Sapphire Optical Fiber Sensor Instrumentation

Standing-Wave Transform Spectrometer Based on Integrated MEMS Mirror and Thin-Film Photodetector

Stabilized Interrogation and Multiplexing. Techniques for Fiber Bragg Grating Vibration Sensors

Low aberration monolithic diffraction gratings for high performance optical spectrometers

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

Analysis of phase sensitivity for binary computer-generated holograms

Tunable wideband infrared detector array for global space awareness

Design and optimization of microlens array based high resolution beam steering system

Supplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers.

Multispectral Image Capturing System Based on a Micro Mirror Device with a Diffraction Grating

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

MODULAR ADAPTIVE OPTICS TESTBED FOR THE NPOI

Optical MEMS pressure sensor based on a mesa-diaphragm structure

Integrated photonic circuit in silicon on insulator for Fourier domain optical coherence tomography

SENSOR+TEST Conference SENSOR 2009 Proceedings II

Design and Simulation of Optical Power Splitter By using SOI Material

Fiber Optic Sensing Applications Based on Optical Propagation Mode Time Delay Measurement

Supplementary Materials

Results from the Stanford 10 m Sagnac interferometer

z t h l g 2009 John Wiley & Sons, Inc. Published 2009 by John Wiley & Sons, Inc.

Spider Pulse Characterization

Deformable MEMS Micromirror Array for Wavelength and Angle Insensitive Retro-Reflecting Modulators Trevor K. Chan & Joseph E. Ford

MEMS in ECE at CMU. Gary K. Fedder

Microlens array-based exit pupil expander for full color display applications

GRENOUILLE.

PHY 431 Homework Set #5 Due Nov. 20 at the start of class

Silicon Photonic Device Based on Bragg Grating Waveguide

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

OCT Spectrometer Design Understanding roll-off to achieve the clearest images

Development of a Package for a Triaxial High-G Accelerometer Optimized for High Signal Fidelity

SILICON BASED CAPACITIVE SENSORS FOR VIBRATION CONTROL

A novel microspectrometer technology for IR spectral imaging applications

Heterodyne Interferometry with a Supercontinuum Local Oscillator. Pavel Gabor Vatican Observatory, 933 N Cherry Ave., Tucson AZ 85721, USA

CHAPTER 2 POLARIZATION SPLITTER- ROTATOR BASED ON A DOUBLE- ETCHED DIRECTIONAL COUPLER

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

Angela Piegari ENEA, Optical Coatings Laboratory, Roma, Italy

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002

A Doubly Decoupled X-axis Vibrating Wheel Gyroscope

Si-EPIC Workshop: Silicon Nanophotonics Fabrication Directional Couplers

Laser Scanning 3D Display with Dynamic Exit Pupil

Design and Manufacture of 8.4 m Primary Mirror Segments and Supports for the GMT

Two bit optical analog-to-digital converter based on photonic crystals

Swept Wavelength Testing:

Stresa, Italy, April 2007

INTEGRATED ACOUSTO-OPTICAL HETERODYNE INTERFEROMETER FOR DISPLACEMENT AND VIBRATION MEASUREMENT

Application Note (A11)

High-yield Fabrication Methods for MEMS Tilt Mirror Array for Optical Switches

Novel piezoresistive e-nose sensor array cell

Displacement sensor by a common-path interferometer

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

some aspects of Optical Coherence Tomography

PhysicsAndMathsTutor.com 1

Integrated electro-optical waveguide based devices with liquid crystals on a silicon backplane

Diffraction. Interference with more than 2 beams. Diffraction gratings. Diffraction by an aperture. Diffraction of a laser beam

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Guide to SPEX Optical Spectrometer

Observational Astronomy

Micro-nanosystems for electrical metrology and precision instrumentation

Feature-level Compensation & Control

IST IP NOBEL "Next generation Optical network for Broadband European Leadership"

NIR SPECTROSCOPY Instruments

Micro-sensors - what happens when you make "classical" devices "small": MEMS devices and integrated bolometric IR detectors

Waveguiding in PMMA photonic crystals

Modal Analysis of Microcantilever using Vibration Speaker

Powerful Single-Frequency Laser System based on a Cu-laser pumped Dye Laser

9. Microwaves. 9.1 Introduction. Safety consideration

Silicon on Insulator CMOS and Microelectromechanical Systems: Mechanical Devices, Sensing Techniques and System Electronics

D.C. Emmony, M.W. Godfrey and R.G. White

Infrared broadband 50%-50% beam splitters for s- polarized light

Transcription:

A MEMS Based Visible-NIR Fourier Transform Microspectrometer C. Ataman 1, H. Urey 1, S.O. Isikman 1, and A. Wolter 2 1 Optical Microsystems Laboratory, Department of Electrical Engineering, Koc University Rumeli Feneri Yolu, 3445, Sariyer, Istanbul, TURKEY Phone: +9-212-338-1474, E-mail: cataman@ku.edu.tr, hurey@ku.edu.tr 2 Fraunhofer Institute of Photonic Microsystems, Germany ABSTRACT Design, fabrication and characterization of a novel out-of-plane vertical comb-drive actuator based Fourier transform microspectrometer (FTS) is presented. The spectrometer utilizes resonant mode vertical comb actuators as a variable-depth diffraction grating and a single photodetector to monitor the th order of the diffraction pattern. The spectrum of the source illuminating the gratings is computed by Fourier transforming the th order intensity as a function of the optical path difference. The vertical comb actuators have a travel range of 1µm under atmospheric pressure with 28V excitation, which yields a theoretical spectral resolution of.5nm in the visible and better than 5nm in the telecom wavelengths. Keywords: Comb actuation, Fourier transform spectroscopy, MEMS, diffraction grating. 1. INTRODUCTION A lamellar grating interferometer (LGI) is a special type of Fourier transform spectrometer based on a diffraction grating operating in the th order [1]. If multiple periods of a resonating vertical comb actuator are illuminated by a light beam, the light diffracts into several different orders equally spaced by an angle determined by the period of the fingers. The intensity at the center of the th diffraction order depends solely on the spectral content of the illuminating light. Fourier transform of the th order intensity as the optical path difference of the grating changes gives the spectrum of the diffracted beam. For high resolution spectrometry, the travel range of the movable fingers should be as high as possible. Due to the lack of a beam-splitter in an LGI very compact spectrometers with good performance can be realized. A Lamellar Grating Interferometer based on out-of plane mode resonant comb actuators is presented. Out-ofplane resonant mode operation of the comb actuators allows for large deflections (high spectral resolution) while providing a large light collection mirror area compared to other microspectrometers reported in the literature [2-3]. Fabrication and operation principles of the device are simple. This minimizes the size, complexity, cost and design effort of a fully functional system (an operational spectrometer using this device requires integration with a simple photodetector and readout circuit). Only moving part is the resonating MEMS structure. With slight modifications in the device dimensions, spectrometers for very wide range of wavelengths can be realized. Structural properties of the movable grating designed for this application is presented in section 2. Operation principle of the spectrometer system is described in section 3. Section 4 explores the theoretical and experimental performance analysis results for the system. 2. MOVABLE GRATING STRUCTURE 2.1 Device Layout The device is fabricated and packaged inside a LCC housing by Fraunhofer IPMS, Germany. In Figure 2, a picture of the packaged device can be seen. The core of the structure consists of two sets of electrostatic comb fingers that are simultaneously utilized as an actuator and a variable-depth diffraction grating. The comb fingers have a high fill-factor (7µm finger width and 5µm gap) and are covered with a thin aluminum layer to enhance reflectivity; thus a high light efficiency is obtained. Movable comb fingers are attached to a 25µm wide H- shaped backbone to increase the stability. This backbone is bonded to the fixed frame via four folded flexure

beams, which provide low stiffness within a compact structure. The folded flexures which have varying crosssectional width to have uniform stress distribution and to provide low stiffness within a compact structure [4]. Low stiffness springs are essential to lower the resonance frequency and increase deflection. These effects decrease the required speed of the readout electronics and enhance spectral resolution, respectively. The flexures are placed at a 45 angle to obtain a better mode separation between the fundamental and higher modes. The folded flexure arms get thinner in cross-section towards the middle of the beam, which helps uniform stress distribution within the flexure. Figure 1: Packaged device Figure 2: The ANSYS model of the spectrometer. The fixed comb fingers are not shown in the Figure. The spectrometer is fabricated on silicon-on-insulator (SOI) wafer, and the process is CMOS compatible. Details of similar process flows were given elsewhere [5]. A cross-section drawing showing the fabricated layers is given in Figure 3.

Si SiO 2 Al SiN Figure 3: Cross-section of the fabricated device Due to the process requirements, the device was designed to withstand mechanical shocks as strong as 2g. The results of the shock resistance simulations are given in Figure 4. (a) (b) Figure 4: FEA results showing the shock resistance of the device. A) A 2g shock of 6 µs duration along the out-of-plane direction produces a maximum stress of 1.25GPa, which is not enough to lead to fracture. b) Transient motion of the movable part of the device after such a shock. 3. OPERATION PRINCIPLE OF THE SPECTROMETER In its simplest form, a Fourier transform spectrometer consists of two mirrors, one of which can be moved along its normal direction, located perpendicularly to each other and with a beam splitter placed at the vertex of the right angle and oriented at a 45 angle relative to the two mirrors. This is a Michelson Interferometer configuration with a movable mirror. Radiation incident on the beam splitter from one of the two "ports" is then divided into two parts, each of which propagates down one of the two arms and is reflected off one of the mirrors. The two beams are then recombined and transmitted out the other port. When the position of one mirror is continuously varied along the axis of the corresponding arm, an interferogram is swept out as the two phaseshifted beams interfere with each other [6]. This interferogram encodes the spectrum of the light illuminating the mirrors. An LGI uses the same principle, however the splitting of the radiating beam is accomplished by a diffraction grating, and interference of the split waves is achieved by diffraction. 3.1 Out-of-plane Mode Comb Actuators as Movable Diffraction Gratings The grating introduces a rectangular phase profile to the illuminating uniform wavefront, due to the phase difference between the portions of the wavefront reflected from the front and back facets of the grating. The intensity profile of the diffracted light will be diffracted with propagation. Right after the grating, diffracted light

has the identical profile as the grating. Far field diffraction pattern of the light will have the shape of the Fourier Transform of the diffraction grating. Figure 5: Schematics of a comb-drive rectangular diffraction grating illuminated by monochromatic light, and modulation of the zeroth order intensity as the grating depth d is continuously varied over a distance of multiple wavelengths. Due to the periodicity of the fingers, comb actuators can be utilized as a tunable diffraction grating, which is a good candidate for Lamellar Grating Interferometry. If a resonating out-of-plane mode comb structure is used as a diffraction grating, the intensity recorded by a detector placed at the center of the diffraction plane would be [2] I center = 2 4πd Acos max cos 2πf λ res t (1) where, f res is the resonant frequency of the comb structure. Equation 3 implies that at the center of the diffraction plane, the light intensity is sinusoidally modulated with respect to the OPD introduced by the grating. Therefore, while the movable fingers of the spectrometer are resonating, the intensity recorded by a single photodetector placed at the center of the diffraction profile with respect to grating depth will be modulated with a raised cosine function. However, due to the sinusoidal speed variation of the fingers, frequency of the raised cosine intensity modulation will be chirped. This chirp can easily be corrected electronically to produce the desired intensity vs. grating depth signal, which is a raised cosine of period λ/4. A Fourier transform operation performed on this signal would directly lead to the wavelength of the illuminating light. The same principle can also be used for spectral analysis of broadband sources. 4. THEORETICAL AND EXPERIMENTAL PERFORMANCE ANALYSIS 4.1 Mechanical Response Fabricated devices were tested under atmospheric pressure, and they were successfully excited in the desired out-of-plane mode. The damped resonance frequency of the structure is measured to 1223 Hz. Figure 6 shows the measured frequency response of the device. The frequency response of the spectrometer shows a hysteretic behavior. Amplitude of the oscillations makes sudden jumps at two different frequencies. The interval between these two jump frequencies f1 and f2 is the unstable region of the response curve. Oscillations in this region can only be observed if the external frequency is quasi-statically swept down to this region from above. The oscillation frequency of the device is half the excitation frequency, which is called a subharmonic resonance. This type of frequency characteristics indicates that the system is a parametric oscillator. Similar

system dynamics are also observed in torsional comb-actuated microscanner devices. Dynamics of such a system were investigated in detail in our earlier works [8]. Travel Range ( m) 1 Increasing Sweep Decreasing Sweep 5 24 25 26 27 28 Drive Frequency (Hz) Figure 6: Hysteretic frequency response of the spectrometer with 28V excitation amplitude 4.2 Spectral Resolution As mentioned, the device is capable of producing ±52µm vertical deflection in the resonant mode with 28V excitation. This leads to a theoretical spectral resolution of ~.5 nm in the visible range and ~5nm in the telecom wavelengths. Figure 7 shows the simulation results for spectral resolution of the device. The simulations are performed with MATLAB. (a) Figure 7: Spectral resolutions of the specified design simulated using the maximum travel range values obtained from Error! Reference source not found.. The device provides a resolution of (a).9nm at 5nm, and 3.6nm at 1nm. (b).

4.3 Optical Efficiency The use of the polished top surface and out-of-plane actuation produces good flatness and a large clear aperture (3mm x 3mm) for the incident beam. Since the structure utilizes the th order diffracted light without requiring additional optics or beam splitters, the theoretical optical efficiency is >8% and limited only by the fill-factor of the comb fingers. This efficiency level is significantly better than its counterparts. Experimental diffraction efficiency of the device is measured to be 15%, which is much lower than the theoretical value (Figure 8). This is due to the stress-induced bow of the long and thin comb fingers. Due to this bow, a built-in height difference between the comb fingers are present, and this yields to diffraction, even in the static case. Figure 8c shows an interferometric picture of the static and movable fingers. The height difference between the fingers is clearly visible from this figure. -.1 Diffraction profile of the spectrometer -.8 -.6 Vertical Diffraction Angle (rad) -.4 -.2.2.4.6 1 th Order th Order -1 th Order.8.1 -.1 -.8 -.6 -.4 -.2.2.4.6.8.1 Vertical Diffraction Angle (rad) (a) (b) (c) Figure 8: Diffraction efficiency of the spectrometer system. (a) Diffraction simulation results for zero OPD. Efficiency is %XX. b) Experimental diffraction profile for zero OPD. Efficiency is %15, which is significantly lower than the theoretical value. c) White-light Interferometric picture of the movable and fixed fingers that show the bending of the fingers. 4.4 Spectral Measurements Spectrum measurements are performed with a single photodetector placed at th order. Due to the resonant motion of the device, the speed of the movable fingers is not constant, but sinusoidally varying. Therefore, the intensity recorded by the detector (I(t)) for a monochromatic source is a chirped (i.e. varying frequency) sinusoid.

LDV Output (V).8.4 -.4.5.1.15.2.2.5.4.3.1 Detector Output (V) -.8 Time (sec) Figure 9: Experimental measurement data on the modulation of th order intensity as the movable fingers resonate. The travel range of the comb fingers in this case is 3µm Figure 9 gives the experimental data showing how the th order intensity modulated as the movable fingers of the device resonate with a travel range of 3µm. The chirped cosine modulation of the intensity can be seen on top of a bigger sinusoidal signal of comb oscillation frequency. 5. CONCLUSION A comb-actuator based Fourier Lamellar Grating Interferometer is designed and implemented. The operation principle of the device is simple and can easily be integrated into a fully functional spectrometer system with a single photodetector and readout electronics. Proposed design can move 1 µm along out-of-plane direction which yields a resolution better than.5nm in the visible band and better than 5 nm for telecom wavelengths. A thicker SOI wafer can be used to improve the deflection range and the resolution of the spectrometer in future design iterations. The proposed design has many advantages compared to other spectrometers available in the literature: Fabrication and operation principles of the device are simple. This minimizes the size, complexity, cost and design effort of a fully functional system. Only moving part is the resonating MEMS structure. Small system size enables portable devices. Out-of-plane resonant mode operation of the comb actuators allows for large deflections (high spectral resolution) and high speed while providing a large light collection mirror area. Due to the operation principle, with slight modifications in the device dimensions, spectrometers for very wide range of wavelengths can be realized. ACKNOWLEDGEMENTS The authors would like to thank Dr. Harald Schenk for sharing his experience on microspectrometers, and to Zeljko Skolic for his help on the mask design. REFERENCES [1] P.R. Griffiths, Fourier Transform Infrared Spectrometry, John Wiley & Sons, 1986. [2] O. Manzardo, H. P. Herzig, C. R. Marxer, N. F. de Rooij, Miniaturized time-scanning Fourier transform spectrometer based on silicon technology, Opt. Lett., vol. 24, pp. 175 177, 1999. [3] Kenda, W. Scherf, R. Hauser, H. Grüger, H. Schenk, A Compact Spectrometer based on a Micromachined Torsional Mirror Device, Proceedings of IEEE Sensors, vol. 3, pp.1312-1315, 24. [4] G. Niederer, H. P. Herzig, M. T. Gale, M. Salt, M. Schnieper, H. Thiele, C. Zschokke, Resonant Grating Filters at Oblique Incidence, SPIE Proceedings, Vol. 5 183-6,2 [5] H. Schenk, P. Dürr, T. Haase, D. Kunze, U. Sobe, H. Lakner, H. Kück, Large deflection micromechanical scanning mirrors for linear scans and pattern generation, Journal of Selected Topics in Quantum Electronics, Vol. 6, No. 5, p.715-722, 2. [6] Fourier Transform Spectrometer, available online at http://scienceworld.wolfram.com/physics/fouriertransformspectrometer.html [7] C. Ataman, H. Urey, Modeling and characterization of comb actuated resonant microscanners, Journal of Micromechanics and Microengineering, Vol. 16 pp. 9-16, 26.