DS10000ULFS-10V/10kA

Similar documents
DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DSSIU-6-1U. Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers.

DSSIU-6-1U-V. Features VOM:

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

High Performance Current Transducer ITL 900-T = A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Current Transducer CTSR 1-P = 1A

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3

Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

HO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM

I PN. Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

Current transducer FHS 40-P/SP600

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

Voltage transducer DVL 50

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

The four pin one (J1) makes possible to supply the board and access to the output voltage easily. It has the following pin-out:

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

HC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS. Datasheet

Customer: Standard type Page 1 of 7 Description Fluxgate current sensor with toroidal core PCB mounting

Sensors & Accessories

= 600 V. Voltage transducer DVM 600 V PN

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

Unipolar voltage - Current output 4-20 ma Ref: DVL 50-UI, DVL 150-UI, DVL 250-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

World-Class Accuracy & Measurement Range (40 Conventional Models)

SPECIFICATION Item No.: T60404-P4640-X100

Flexible AC current probes

= 1000 V. Voltage transducer DVC 1000-P V P N

AUTOMOTIVE CURRENT SENSOR HC6H300-S

V P N. Voltage transducer DVM 4200 = 4200 V

Residual Current Monitoring Unit RCMU101SN-4P16

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S02

DC Current Transducers CT-200 CT-300 CT-400 User s Manual All Rights Reserved CAEN ELS d.o.o. Rev. 1.0 November 2014

Residual Current Monitoring Unit RCMU101SN-4P16C

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00

AUTOMOTIVE CURRENT SENSOR HC6H500-S. Datasheet

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

V P N. Voltage transducer DVL 1000 = 1000 V

Wide-band Models from DC to 100 MHz

Wide-band Models from DC to 100 MHz

AUTOMOTIVE CURRENT TRANSDUCER HC6F600-S

AUTOMOTIVE CURRENT TRANSDUCER HC6F700-S

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DRW 300-S

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

High precision measurement system for current and voltage IHC-A/B-RM01/03

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

Customer: Standard type Page 1 of 7 Description Fluxgate current sensor with toroidal core PCB mounting

Current transducer FHS 40-P/SP600

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Voltage Adjustment. Load Regulation

I Pr I P I OUT R L. Applications. Standards

AUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

V P N. Voltage transducer DVM 2000-B = 2000 V

SPECIFICATION Item no.: T60404-N4646-X764

imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance

AUTOMOTIVE CURRENT TRANSDUCER HAH1DR 300-S

Specifications. PCI Bus. Analog Input Input Characteristics

ULTRASTAB I U Precision

Transcription:

Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 11kA Features Linearity error maximum +/- 7ppm 3 pin XLR mini connector for voltage output Transducer core optimized for high level of immunity against external magnetic fields Operating temperature Ratio 1V/1000A Transducer head 0-50 C Electronics 0-45 C Aperture diameter 140 mm 2U 19 Control unit with universal (100-240V AC 50/60Hz) AC input voltage or 120-370V DC input voltage Danisense advanced sensor protection circuit ASPC Applications: MPS for particles accelerators Stable power supplies Precision drives Batteries testing and evaluation systems Power measurement and power analysis Current calibration purposes Specifications highlights (@23⁰C) Symbol Unit Min Typ Max Measuring range (DC or AC peak) I PM ka -11 11 Nominal primary AC current I PN AC karms 7 Nominal primary DC current I PN DC ka -10 10 Nominal output voltage @ 10kA V SN V -10.000 10.000 Primary / secondary ratio Ratio V/kA 1.000 Linearity error Ɛ L ppm -7 7 Offset current (including earth field) V OE ppm -11 11 DC-10Hz Overall accuracy @25 C (= Ɛ L + I OE ) Ɛ DC ppm -23 23 AC Max. gain error (10Hz to 1kHz) Ɛ AC % -0.05 0.05 AC Max. phase shitf error (10Hz to 1kHz) q ⁰ 0.05 Bandwidth f(-3db) khz 100 All Operting ppm (or temperature %) values refer transducer to nominal head current 7500A Ta or 10V ⁰C 0 50 page 1-2017-08-31

Electrical specifications at Ta=23 C Parameter Nominal primary AC current Nominal primary DC current Measuring range Overload capacity Nominal output voltage Primary / secondary ratio Linearity error Bandwidth Symbol Unit Min Typ. Max Comment I PN AC karms 7 Refer to fig. 2 for derating I PN DC ka -10 10 I PM ka -11 11 DC or peak value Î OL ka 35 Non-measured, 100ms Vout V -10 10 At nominal DC current Ratio V/kA -1.000 1.000 ppm -7 7 ppm refers to nominal current µv -70 70 µv refers to output voltage f(-3db) khz 100 Small signal, graphs figure 3 Amplitude error 10Hz 1kHz 0.05% 1kHz -5kHz Ɛ G % 1.50% % refers to nominal current 5kHz - 30kHz 15.00% Phase shift 10Hz 1kHz 0.05º 1kHz -5kHz q º 0.50º 5kHz - 30kHz 3.00º Response time to a step current IPN tr @90% µs 1 di/dt = 100A/µs Noise 0-100Hz 0.1 0-1kHz 0.7 noise ppm rms Measured on secondary current 0-10kHz 5.0 0-100kHz 7.0 Fluxgate excitation frequency Induced rms voltage on primary conductor Mains input voltage AC Mains input voltage DC Operating temperature range / Control unit Operating temperature range / Head Offset error Initial (including earth field) Versus temperature Versus time Ratio error Initial Versus temperature Versus time Influence of external field Offset change with external vertical magnetic field Offset change with external horizontal magnetic field Ɛ L f Exc khz 7.82 µv rms 10 V AC V rms 90 295 50 / 60Hz V DC V 127 417 Ta C 0 45 Ta C 0 50 ppm -11 11 ppm refers to nominal current µv -110 110 µv refers to output voltage ppm/k -0.3 0.3 ppm refers to nominal current µv/k -3 3 µv refers to output voltage ppm/mont h -0.1 0.1 ppm refers to nominal current µv/month -1 1 µv refers to output voltage ppm -5 5 ppm refers to nominal current µv -50 50 µv refers to output voltage ppm/k -1.5 1.5 ppm refers to nominal current µv/k -15 15 µv refers to output voltage ppm/mont h -20 20 ppm refers to nominal current µv/month -200 200 µv refers to output voltage ppm TBD TBD ppm refers to nominal current µv µv refers to output voltage ppm/k TBD TBD ppm refers to nominal current µv/k µv refers to output voltage page 2-2017-08-31

Primary Current (A) Frequency and ambient temperature derating (Fig. 2) 10000 Maximum primary current A rms 1000 100 10 1 10Hz 100Hz 1,000Hz 10,000Hz 100,000Hz 1,000,000Hz Primary Current (Hz) Max current (Arms) 65 deg Max current (Arms) 45 deg Max current (Arms) 25 deg Frequency characteristics (Fig. 3) 10.00 Amplitude / Phase 5.00 0.00-5.00-10.00 10Hz 100Hz 1,000Hz 10,000Hz Amplitude (%) Phase Error (deg) page 3-2017-08-31

Isolation specifications Parameter Unit Value Rated isolation voltage rms, reinforced isolation IEC 61010-1 standard and with following conditions 3 - Overvoltage category III -Pollution degree 2 kv Rms voltage for AC isolation test, 50/60 Hz, 1 min - Between primary and (secondary and shield) - Between secondary and shield kv 23.7 0.2 Impulse withstand voltage kv 43.5 Creepage distance / Clearance mm 60 / 60 Comparative Tracking Index CTI 600 Absolute maximum ratings Parameter Unit Max Comment Primary current ka 35 Maximum 100ms Primary current ka 11 Continous Environmental and mechanical characteristics Parameter Unit Min Typ Max Comment Ambient operating temperature range C 0 45 Control unit Ambient operating temperature range C 0 60 Transducer head Storage temperature range C -40 85 Relative humidity % 20 80 Non-condensing Mass kg 17 6 Transducer Head Control Unit Connections 3 pin XLR mini Standards EN 61326-1 EMC EN 61010-1:2010 Safety page 4-2017-08-31

Advanced Sensor Protection Circuits ASPC Developed to protect the current transducer from typical fault conditions: Unit is un-powered and secondary circuit is open or closed Unit is powered and secondary circuit is open or interrupted Both DC and AC primary current up to 100% of nominal value can be applied to the current transducers in the above situations without damage to the electronics. Please notice that the sensor core can be magnetized in all above cases, leading to a small change in output offset current (less than 10ppm) Package content Transducer head Electronics box 19 2U AC power cable - Region specific 5m cable between transducer head and electronics box (Custom sizes can be delivered at extra charge) 2m XLR mini cable to connect the voltage output to 4mm banana plugs (+, - and cable shield) page 5-2017-08-31

DS10000 Transducer Head Dimensions 140mm page 6-2017-08-31

User Guide Intended use: The is intended to measure the current flowing through the aperture of the transducer head. The measured current is available as a voltage output on the XLR mini connector (2m cable is included with 4mm safety banana plugs). The voltage output is 10V/10kA. Instruction for use: 1. Do not apply primary current through the transducerhead before everything is connected and powered. 1. Cable from transducer head to electronics control box must be connected 2. The electronics control box needs to be mains powered. (Universal input) 2. If the electronics control unit is intended for desk use, mount the rubber feet which are part of the package. If the electronics control unit is intended for Rack mounting, use the screw kit for mounting and do not mount the rubber feet. 3. Connect a precision voltage analyzer to the XLR cable for analysis purposes. Indications: When mains is applied a green light diode on the front under the power symbol will light green, indicating the transducer is working and is tracking the input signal. Safety Instructions: DO NOT TRY TO DISASSEMBLE THE UNIT. Make sure that the unit is properly connected to earth ground. Do not block the ventilation openings on the side panels. If the fan does not operate properly contact Danisense for repair. If the POWER green diode is not operating when mains is applied, disconnect power and contact Danisense for further instruction. CE Statement: This product has been tested and found to comply with the following standards. Electrical safety: EN 61010-1 2010 Electromagnetic Compatibility: EN 61326-1 2013 page 7-2017-08-31