Lessons In Industrial Instrumentation

Similar documents
120 VAC. 12 VAC center-tapped

ECET 211 Electric Machines & Controls Lecture 7 Relays. Lecture 7 Relays

Take for instance this circuit:

Conventional transistor overview and special transistors

Chapter 5 Electric Logic Sensors and Actuators

Electrical Controls. Isaac Queen

ECET 211 Electric Machines & Controls Lecture 7 Relays (1 of 2) Lecture 7 Relays

Creating Electrical Designs

Unit 2 Electrical Circuit Diagrams

Switches. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Switches. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

(c) Figure 1.1: Schematic elements. (a) Voltage source. (b) Light bulb. (c) Switch, open (off). (d) Switch, closed (on).

Implementation Of Solid State Relays For Power System Protection

Electrical Motor Controls Chapter 5 (4 th Edition) Chapter 5 (5 th Edition)

Experiment (1) Principles of Switching

The silicon controlled rectifier (SCR)

CIRCUITS THAT ARE AVAILABLE ON LODAR RECEIVERS Features listed below are available on 92 Series and 93 Series

Home Map Projects Construction Soldering Study Components 555 Symbols FAQ Links

Component modeling. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

TEACHING PLC IN AUTOMATION --A Case Study

Closed loop Heat Temperature Thermostat Heater Voltage to Heater

Using Circuits, Signals and Instruments

Lab# 13: Introduction to the Digital Logic

Using Magnetic Sensors for Absolute Position Detection and Feedback. Kevin Claycomb University of Evansville

Question 1 Given a battery and a light bulb, show how you would connect these two devices together with wire so as to energize the light bulb:

Power systems Protection course

Basic Microprocessor Interfacing Trainer Lab Manual

Microcontroller principles

Microcontroller principles

Fast IC Power Transistor with Thermal Protection

ZBasic. Application Note. AN-213 External Device Interfacing. Introduction. I/O Pin Fundamentals. Connecting an LED

Introduction. Inductors in AC Circuits.

CAMTO. Arc detecting relay. system. January Revised August D D1200

Technician Licensing Class T6

Autonomous Robot Control Circuit

ELM334 Garage Doorman


MOSFET as a Switch. MOSFET Characteristics Curves

T6A4. Electrical components; fixed and variable resistors, capacitors, and inductors; fuses, switches, batteries

15P0161B1 - DCREG for Applications to Electromagnets - SW Rev. D3.09 R.03 - Updated 01/04/04

Switched capacitor circuitry

DLVP A OPERATOR S MANUAL

Chapter 1: Digital logic

Device Interconnection

VCE VET ELECTROTECHNOLOGY

New Current-Sense Amplifiers Aid Measurement and Control

BASIC-Tiger Application Note No. 059 Rev Motor control with H bridges. Gunther Zielosko. 1. Introduction

Process Components. Process component

Cornerstone Electronics Technology and Robotics I Week 19 Electrical Relays

Contents. Acknowledgments. About the Author

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 919 RAILROAD PREEMPTION INTERFACE. January 15, 2016

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

SHORT FORM. Product Catalog. (800) time-mark.com

SUBELEMENT T6 Electrical components: semiconductors; circuit diagrams; component functions 4 Exam Questions - 4 Groups

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

Electronics. RC Filter, DC Supply, and 555

PREREQUISITES: MODULE 10: MICROCONTROLLERS II; MODULE 14: DISCRETE COMPONENTS. MODULE 13 (SENSORS) WOULD ALSO BE HELPFUL.

Programmable Logic Controllers: Programming Methods. and Applications

ADVANCED PLC PROGRAMMING. Q. Explain the ONE SHOT (ONS) function with an application.

A Super trainer with advanced hardware and software features only found in very expensive equipment.

Logic diagram: a graphical representation of a circuit

Name: Class: Date: 1. As more electronic systems have been designed using digital technology, devices have become smaller and less powerful.

Ionization (gas filled) tubes

Chapter 1 - Introduction to Mechatronics. Questions

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

Digital Logic Circuits

ECET 211 Electric Machines & Controls Lecture 2-1 (Part 1 of 3) Symbols and Drawing for Electric Motor Control Systems

LOW COST AUTOMATIC WATER LEVEL CONTROL FOR DOMESTIC APPLICATIONS

The operational amplifier

ET 438b Sequential Control and Data Acquisition Department of Technology. Identify the electrical characteristics of a TTL interface

2 Thermistor + Op-Amp + Relay = Sensor + Actuator

Chapter 3 Describing Logic Circuits Dr. Xu

The Ins and Outs of Basic. A practical approach to reading and understanding the schematic diagrams used to explain how HVACR systems operate.

Solid State Relays Dr. Lynn Fuller Webpage:

Introduction to PLC and Ladder Logic Programming

Multiple input gates. The AND gate

Application Note AN-3006 Optically Isolated Phase Controlling Circuit Solution

SAMPLE. Electrical Diagrams C H A P T E R 7

GCSE Electronics. Scheme of Work

TIG 250 AC-DC. POWER SOURCE art

Design and Technology

Utility and Energy Systems Program

Instant MTBF Data Input Sheet Commercial / Bellcore TR Integrated Circuits, Bipolar, Digital

MODULE 06 POWER SUPPLIES

Digital Fundamentals. Lab 4 EX-OR Circuits & Combinational Circuit Design

DIGITAL ELECTRONICS: LOGIC AND CLOCKS

Know about. Different Types of Relays

Stepper motors. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Automatic Voltage Reducer for LiPo 4S Batteries Phil Salas AD5X

1.) If a 3 input NOR gate has eight input possibilities, how many of those possibilities result in a HIGH output? (a.) 1 (b.) 2 (c.) 3 (d.) 7 (e.

Low Quiescent Current Surge Stopper: Robust Automotive Supply Protection for ISO and ISO Compliance

High Current MOSFET Toggle Switch with Debounced Push Button

o What happens if S1 and S2 or S3 and S4 are closed simultaneously? o Perform Motor Control, H-Bridges LAB 2 H-Bridges with SPST Switches

ELE1. ELECTRONICS Unit 1 Foundation Electronics. General Certificate of Education June 2004 Advanced Subsidiary Examination

3/4/2015. Basic relay construction. Shading coil in AC relays. Timothy L. Skvarenina and William E. DeWitt Electrical Power and Controls, 2e

Performance-based assessments for basic electricity competencies

Characteristic Impedance

University of North Carolina-Charlotte Department of Electrical and Computer Engineering ECGR 3157 Electrical Engineering Design II Fall 2013

Draw the symbol and state the applications of : 1) Push button switch 2) 3) Solenoid valve 4) Limit switch ( 1m each) Ans: 1) Push Button

Basic operational amplifiers

Transcription:

Lessons In Industrial Instrumentation c 2008-207 by Tony R. Kuphaldt under the terms and conditions of the Creative Commons Attribution 4.0 International Public License Version 2.25 (development) Last update August 6, 207 This copy shared by Electrical Engineering XYZ. Enjoy the world of Free Electrical Downloads at: http://

Electrical Engineering XYZ Everything on Electrical Engineering Learn everything about Electrical Engineering Enjoy free downloads, read free articles and many more on our website: http:// List of contents Relay control systems 745. Control relays........................................ 747.2 Relay circuits........................................ 75.3 Interposing relays...................................... 758.4 Review of fundamental principles............................. 76

Chapter Relay control systems The word discrete means individual or distinct. In engineering, a discrete variable or measurement refers to a true-or-false condition. Thus, a discrete control system is one designed to operate on Boolean ( on or off ) signals supplied by discrete sensors such as process switches. A form of discrete control taught in every introductory course on digital electronics involves the use of circuits called logic gates. These circuits input one or more Boolean signals, and output a Boolean signal according to a simple rule such as AND or OR : A B 0 0 0 0 AND Output 0 0 0 A B 0 0 0 0 OR Output 0 XOR A B Output 0 0 0 0 0 0 A B 0 0 0 0 NAND Output 0 A B 0 0 0 0 NOR Output 0 0 0 XNOR A B Output 0 0 0 0 0 0 Industrial control systems rarely utilize logic gates in a direct fashion for discrete control systems, although the fundamental concepts of AND, OR, and other gate types are universally applied. Instead, control functions are either implemented using electromechanical relays and/or 745

746 CHAPTER. RELAY CONTROL SYSTEMS with programmable digital devices such as PLCs (Programmable Logic Controllers). This chapter focuses on the practical use of both technologies for industrial discrete control. An AND function is equivalent to series-connected normally-open contacts in a relay control circuit, because the lamp will energize only if switch A and switch B are actuated: Voltage source A B logic gate + C A B C switch switch lamp An OR function is equivalent to parallel-connected normally-open contacts in a relay control circuit, because the lamp will energize if switch A or switch B is actuated: Voltage source + A B logic gate C A switch B C lamp switch The NOT function is equivalent to a single normally-closed contact in a relay control circuit, because the lamp will energize only if the switch is not actuated: Voltage source + A B A B logic gate switch lamp

.. CONTROL RELAYS 747. Control relays An electromechanical relay is an electrical switch actuated by an electromagnet coil. As switching devices, they exhibit simple on and off behavior with no intermediate states. Relays are very useful devices, as they allow a single discrete (on/off) electrical signal to control much greater levels of electrical power, and/or multiple power or control signals that are otherwise isolated from each other. For example, a relay may be controlled by a low-voltage, low-current signal that passes through a delicate switch of some sort (e.g. limit switch, proximity switch, optical sensor), and then the switching contacts of that relay may be used to control a much higher-voltage, higher-current circuit, and even multiple circuits given multiple sets of switching contacts. The electronic schematic symbol for a simple single-pole, single-throw (SPST) relay is shown here: SPST relay (NO contact) A coil of wire wrapped around a laminated ferrous core provides the magnetic field necessary to actuate the switch mechanism. This electromagnet coil s actuating influence on the relay s contact(s) is represented by the dashed line. This particular relay is equipped with normally open (NO) switch contacts, which means the switch will be in the open (off) state when the relay coil is de-energized. Recall from section 9. that the normal status of a switch is the resting condition of no stimulation. A relay switch contact will be in its normal status when its coil is not energized. A single-pole, single-throw relay with a normally-closed (NC) switch contact would be represented in an electronic schematic like this: SPST relay (NC contact)

748 CHAPTER. RELAY CONTROL SYSTEMS In the electrical control world, the labels Form-A and Form-B are synonymous with normally open and normally closed contacts, respectively. Thus, we could have labeled the SPST relay contacts as Form-A and Form-B, respectively: SPST relay (Form A contact) SPST relay (Form B contact) An extension of this theme is the single-pole, double-throw (SPDT) relay contact, otherwise known as a Form-C contact. This design of switch provides both a normally-open and normallyclosed contact set in one unit, actuated by the electromagnet coil: SPDT relay (Form C contact) A further extension on this theme is the double-pole, double-throw (DPDT) relay contact. This design of switch provides two sets of Form-C contacts in one unit, simultaneously actuated by the electromagnet coil: DPDT relay DPDT relays are some of the most common found in industry, due to their versatility. Each Form-C contact set offers a choice of either normally-open or normally-closed contacts, and the two

.. CONTROL RELAYS 749 sets (two poles ) are electrically isolated from each other so they may be used in different circuits. A common package for industrial relays is the so-called ice cube relay, named for its clear plastic case allowing inspection of the working elements. These relays plug into multi-pin base sockets for easy removal and replacement in case of failure. A DPDT ice cube relay is shown in the following photographs, ready to be plugged into its base (left) and with the plastic cover removed to expose both sets of Form-C contacts (right): These relays connect to the socket with eight pins: three for each of the two Form-C contact set, plus two more pins for the coil connections. Due to the pin count (8), this style of relay base is often referred to as an octal base.

750 CHAPTER. RELAY CONTROL SYSTEMS A closer view of one Form-C contact shows how the moving metal leaf contacts one of two stationary points, the actual point of contact being made by a silver-coated button at the end of the leaf. The following photographs show one Form-C contact in both positions: Industrial control relays usually have connection diagrams drawn somewhere on the outer shell to indicate which pins connect to which elements inside the relay. The style of these diagrams may vary somewhat, even between relays of identical function. Take for instance the diagrams shown here, photographed on three different brands of DPDT relay: Bear in mind that these three relays are identical in their essential function (DPDT switching), despite differences in physical size and contact ratings (voltage and current capacities). Only two of the three diagrams shown use the same symbols to represent contacts, and all three use unique symbols to represent the coil.

.2. RELAY CIRCUITS 75.2 Relay circuits Electromechanical relays may be connected together to perform logic and control functions, acting as logic elements much like digital gates (AND, OR, etc.). A very common form of schematic diagram showing the interconnection of relays to perform these functions is called a ladder diagram. In a ladder diagram, the two poles of the power source are drawn as vertical rails of a ladder, with horizontal rungs showing the switch contacts, relay contacts, relay coils, and final control elements (lamps, solenoid coils, motors) drawn in between the power rails. Ladder diagrams differ from regular schematic diagrams of the sort common to electronics technicians primarily in the strict orientation of the wiring: vertical power rails and horizontal control rungs. Symbols also differ a bit from common electronics notation: relay coils are drawn as circles, with relay contacts drawn in a way resembling capacitors: Ladder diagram symbols NO relay contact NC relay contact Relay coil Indicator lamp Heating element Solenoid coil NO pushbutton switch Overload heater NC pushbutton switch Fuse Electric motor (3-phase) motor Unlike schematic diagrams where the association between relay coils and relay contacts is represented by dashed lines, ladder diagrams associate coils and contacts by label. Sometimes you will find relay contacts labeled identically to the coil (e.g. coil labeled CR5 and all contacts for that relay also labeled CR5) while other times you will find suffix numbers used to distinguish individual contacts within each relay from each other (e.g. coil labeled CR5 and its three contacts labeled CR5-, CR5-2, and CR5-3). Another notable convention in relay circuits and their ladder diagrams is that each and every wire in the circuit is labeled with a number corresponding to common connection points. That is, wires connected together always bear the same number: the common number designates a condition of electrical commonality (all points bearing the same number are equipotential to each other). Wire numbers only change when the connection passes through a switch or other device capable of dropping voltage.

752 CHAPTER. RELAY CONTROL SYSTEMS An actual ladder diagram of a relay-based motor control system is shown here, complete with red-line edits showing modifications to the circuit made by an industrial electrician:

.2. RELAY CIRCUITS 753 Perhaps the most confusing aspect of relay control circuits for students to grasp is the meaning of normal as it applies to the status of relay contacts. As discussed previously, the word normal in this context whether it be the status of hand switches, process switches, or the switch contacts inside control relays means in a condition of rest or no stimulation. In other words, a normallyopen relay contact is open when the relay coil is unpowered and closed when the relay coil is powered. Likewise, a normally-closed relay contact is closed when the relay coil is unpowered and open when the relay coil is powered. To illustrate this concept, let us examine a relay control circuit where a pressure switch activates an alarm light: L L 2 Pressure switch Trip = 50 PSI CR CR- Alarm lamp Here, both the pressure switch and the relay contact (CR-) are drawn as normally-closed switch contacts. This means the pressure switch contact will be closed when the applied pressure is less than its trip point (50 PSI), and the relay switch contact will be closed when the relay coil is de-energized.

754 CHAPTER. RELAY CONTROL SYSTEMS When analyzing the operation of a relay control system, it is helpful to have some way to temporarily denote the conductive status of switch contacts and the energization status of relay coils (i.e. a notation we might sketch using pencil on a diagram to help us follow the operation of the circuit). A symbology I recommend is the use of arrow and X symbols to represent power flow and no power flow (respectively). These symbols clearly denote component status while avoiding confusion with the symbols used to denote normal status of switch contacts. In this next diagram, we assume the applied pressure is less than 50 PSI, leaving the pressure switch in its normal (closed) state: L L 2 Pressure < 50 PSI Pressure switch Trip = 50 PSI CR (Relay coil energized) CR- Alarm lamp (Alarm lamp de-energized) Since the pressure is insufficient to actuate the pressure switch, its contact remains in the normal state (closed). This sends power to relay coil CR, thus actuating contact CR- and holding it in the open state. With CR- contact open, the alarm lamp receives no power. In this example we see the pressure switch in its normal state but the relay in the actuated state. An unfortunately common tendency among novices is to sketch slash marks through relay contact symbols in order to show when they happen to be closed. This is a very bad habit, and should be discouraged at all times! Diagonal lines drawn through a contact symbol are supposed to denote the contact to be normally-closed, not closed: it shows that a switch contact will be in the closed (conducting) state when it is at rest. What we actually need is a different kind of symbol to show when a contact is closed during any arbitrary condition we may imagine. When someone uses this same symbology to denote a contact that happens to be closed during some condition, it needlessly confuses the concepts of closed versus normally-closed.

.2. RELAY CIRCUITS 755 Using arrow and X symbols again to represent the presence or absence of power in this circuit, we will now analyze its status with an applied switch pressure greater than 50 PSI: L L 2 Pressure > 50 PSI Pressure switch Trip = 50 PSI CR (Relay coil de-energized) CR- Alarm lamp (Alarm lamp energized) Now that there is sufficient fluid pressure applied to the switch to actuate it, its contact is forced into the actuated state which for this normally-closed switch is open. This open condition deenergizes relay coil CR, allowing relay contact CR- to spring-return to its normal status (closed), thus sending power to the alarm lamp. From this analysis we see that the lamp fulfills the function of a high pressure alarm, energizing when the applied pressure exceeds the trip point. Where students typically find themselves confused is assuming the switch contact will be in the same state it is drawn in. This is not necessarily true. The way switch contacts are drawn merely reflects their normal status as defined by the switch manufacturer, which means the status of the switch when there is no (or insufficient) actuating stimulus present. Whether or not the switch will actually be in its normal state at any given time is a question of whether or not a sufficient stimulus is present to actuate that switch. Just because a switch is drawn normally-closed does not necessarily mean it will be closed when you go to analyze it. All it means is that the switch will be closed when nothing actuates it. This exact same principle applies to relay ladder-logic programming in electronic control systems called PLCs (Programmable Logic Controllers). In a PLC, a digital microprocessor performs the logic functions traditionally provided by electromechanical relays, with the programming for this microprocessor taking the form of a relay diagram (also called a ladder-logic diagram).

756 CHAPTER. RELAY CONTROL SYSTEMS Here, we will emulate the exact same high-pressure alarm circuit using an Allen-Bradley MicroLogix 000 PLC instead of a relay coil: Wiring diagram: PLC input terminals Pressure switch Trip = 50 PSI 24V DC OUT DC COM I/0 I/ I/2 I/3 DC COM I/4 I/5 Power Run Fault Force Allen-Bradley MicroLogix 000 PLC 85-264 VAC L L2/N VAC VDC O/0 VAC VDC VAC VAC O/ VDC O/2 VDC O/3 L Alarm lamp PLC output terminals L 2 Ladder-logic program: Suppose a fluid pressure of 36 PSI is applied to the pressure switch. This is less than the switch s trip setting of 50 PSI, leaving the switch in its normal (closed) state. This sends power to input I:0/2 of the PLC. The contact labeled I:0/2 drawn in the ladder-logic program of the PLC acts like a relay contact driven by a coil energized by input terminal I:0/2. Thus, the closed pressure switch

.2. RELAY CIRCUITS 757 contact energizes input terminal I:0/2, which in turn closes the normally-open contact symbol I:0/2 drawn in the ladder-logic program. This virtual contact sends virtual power to a virtual coil labeled B3:0/0, which is nothing more than a single bit of data in the PLC s microprocessor memory. Energizing this virtual coil has the effect of actuating any contact drawn in the program bearing the same label. This means the normally-closed contact B3:0/0 will now be actuated and thus in the open state, not sending virtual power to the output coil O:0/. With virtual coil O:0/ unpowered, the real-life output O:0/ on the PLC will be electrically open, and the alarm lamp will be unpowered (off). If we apply a fluid pressure of 6 PSI to the pressure switch, the normally-closed pressure switch contact will be actuated (forced) into the open state. This will have the effect of de-energizing PLC input I:0/2, thus opening the normally-open virtual contact in the PLC program bearing the same label. This open virtual contact interrupts virtual power to the virtual coil B3:0/0, causing the normally-closed virtual contact B3:0/0 to close, sending virtual power to virtual coil O:0/. When this virtual output coil energizes, the real-life output channel of the PLC activates, sending real power to the alarm light to turn it on, signaling a high-pressure alarm condition. We may simplify this PLC program further by eliminating the virtual control relay B3:0/0 and simply having input I:0/2 activate output O:0/ through a normally-closed virtual contact: The effect is the same: the PLC output O:0/ will activate whenever input I:0/2 de-energizes (whenever the pressure switch is opened by a high pressure), turning on the alarm lamp in a high-pressure condition. In a low-pressure condition, the energized input I:0/2 forces the virtual normally-closed contact I:0/2 to open, thus de-energizing the PLC s output O:0/ and turning the alarm lamp off. Programmable Logic Controllers have not only greatly simplified the wiring of industrial logic controls by replacing multitudes of electromechanical relays with a microprocessor, but they have also added advanced capabilities such as counters, timers, sequencers, mathematical functions, communications, and of course the ability to easily modify the control logic through programming rather than by re-wiring relays. The beauty of ladder-logic programming is that it translates the technician s understanding of traditional relay control circuits into a virtual form where contacts and coils interact to perform practical control functions. A key concept to master, however, is the association of real-life conditions to switch status based on the normal representation of those switch contacts, whether the switches be real (relay) or virtual (PLC). Once this vital concept is

758 CHAPTER. RELAY CONTROL SYSTEMS mastered, both hard-wired relay control circuits and PLC programs become possible to understand. Without mastering this vital concept, neither relay control circuits nor PLC programs may be understood..3 Interposing relays In addition to directly performing logic functions, electromechanical relays may also be used as interposing devices between mismatched sensors, controllers, and/or control devices. A very simple example of a relay used to interpose between mismatched devices is shown in the following circuit diagram, where a delicate toggle switch is used to control a bank of high-power lights for an off-road vehicle: 30 amp fuse amp fuse Dashboard toggle switch High-power lights 2 V battery Vehicle chassis ground Vehicle chassis ground SPST relay (NO contact) Vehicle chassis ground In this circuit the relay performs no logic function whatsoever. Rather, it merely amplifies the signal sent by the dashboard toggle switch to send or halt power to the bank of high-power lights. Without the relay, a much heavier-duty toggle switch would have to be installed in the dashboard of this vehicle to safely and reliably make and break the light circuit. Another example of an interposing relay found in automotive applications is the use of a solenoid in the electric starting motor circuit for an internal combustion engine. The start control switch is typically actuated by the driver turning a key, that switch mounted on the steering column or dashboard of the vehicle. The starting motor, meanwhile, typically draws hundreds of amps of current as it labors to start up the engine. A keyswitch capable of making and breaking hundreds of amps of current would be enormous, and in fact dangerous to locate in the cab of the vehicle. The solenoid relay connected between the keyswitch and the starting motor relocates that danger, and allows a relatively delicate keyswitch to safely activate the high-power motor.

.3. INTERPOSING RELAYS 759 An industrial example of an interposing relay between mismatched devices is shown here, where a DC output proximity switch must trigger an input channel to a Programmable Logic Controller (PLC) rated for 20 volts AC: PLC input terminals Commutating diode "Sinking" proximity switch +V Sensor circuit Brn Output Blk Ground Blu SPST relay (NO contact) + 24VDC power source 24V DC OUT 85-264 VAC L L2/N DC AC COM I/0 I/ I/2 I/3 DC AC COM Power Run Fault Force VAC VDC O/0 VAC VDC I/4 I/5 Allen-Bradley MicroLogix 000 PLC VAC VAC O/ VDC O/2 VDC O/3 To 20 VAC power source Again, the relay in this system performs no logic function, but merely allows the proximity switch to drive one of the PLC input channels. Directly connecting the proximity switch to one of the input channels of the PLC is not a practical option, because this particular PLC input requires 20 volts AC to activate, and our proximity switch operates on 24 volts DC. The mismatch between switch voltage and PLC input voltage requires us to use the relay to interpose between the switch and PLC. When the proximity switch senses an object nearby, its output activates, which in turn energizes the relay coil. When the relay contact magnetically closes, it completes a circuit for 20 volts AC to reach input channel 0 on the PLC, thereby energizing it. An important detail in this relay circuit is the inclusion of a commutating diode in parallel with the relay coil, the purpose being to dissipate the coil s stored energy upon de-energization when the proximity switch turns off. Without this diode in place, the coil s kickback voltage (which may reach hundreds of volts in potential) will destroy the proximity switch s output transistor. Note how this commutating diode appears to be connected backwards with regard to the polarity of the 24 volt DC power source: cathode toward the source s positive pole and anode toward the source s negative pole. This is intentional, as we do not wish to have the diode conduct when power is applied to the relay coil through the proximity switch 2. The diode only turns on when the polarity reverses, which is what happens when the proximity switch turns off and the relay coil s magnetic field collapses (now acting as a source rather than as a load). As the relay coil 2 If the diode were connected the other way, it would pass current whenever the proximity switch turned on, shorting past the relay coil and most likely damaging the proximity switch in doing so!

760 CHAPTER. RELAY CONTROL SYSTEMS temporarily outputs a reverse voltage, the diode gives that coil a continuous path for its current while dropping a low voltage (about 0.7 volts DC), dissipating the coil s stored energy in the form of heat at the diode. Interposing relays are also used to connected mismatched PLC outputs and control devices. In this application, the mismatch may be in terms of voltage ratings and/or current ratings. As with the input interposing circuit shown previously, the task of the relay in an output interposing circuit is to be controlled by the PLC s output channel, and in turn direct power to a field device that is itself incompatible with the PLC s output. The following diagram shows an example of an interposing relay connected to a PLC output channel: 24V DC OUT DC AC COM I/0 I/ I/2 I/3 DC AC COM I/4 I/5 Three-phase contactor Power Run Fault Force Allen-Bradley MicroLogix 000 PLC 20 VAC coil PLC output terminals 85-264 VAC L L2/N VAC VDC O/0 VAC VDC (sourcing) DC DC VAC VAC O/3 O/ O/2 O/3 O/4 24V+ O/5 24V- VDC VDC 24VDC power source + To 20 VAC power source Commutating diode SPST relay (NO contact) In this circuit the PLC s transistor outputs can only handle 24 volts DC, and at fairly low current. The three-phase contactor 3 coil requires 20 volts AC at modest current levels to function, and so the relay interposes between the PLC s low-voltage and low-current output channel and the relatively high-voltage and high-current demands of the contactor s coil. Once again we see the use of a commutating diode to dissipate the relay coil s stored energy whenever the PLC de-energizes it, so that the resulting kickback voltage does not damage the fragile transistor output circuitry within the PLC. 3 A contactor is nothing more than a very large electromechanical relay, and itself is a form of interposing device. Its purpose is to make and break three-phase AC power to a heavy load (e.g. an electric motor) at the command of a much smaller electrical signal, in this case a 20 volt AC signal sent to the coil of the contactor.

.4. REVIEW OF FUNDAMENTAL PRINCIPLES 76.4 Review of fundamental principles Shown here is a partial listing of principles applied in the subject matter of this chapter, given for the purpose of expanding the reader s view of this chapter s concepts and of their general interrelationships with concepts elsewhere in the book. Your abilities as a problem-solver and as a life-long learner will be greatly enhanced by mastering the applications of these principles to a wide variety of topics, the more varied the better. Amplification: the control of a relatively large signal by a relatively small signal. Relevant to the role of relays as interposing devices. Interposing: the use of a relay as an intermediary between electrically incompatible devices. Normal switch status: the normal status of a switch contact as defined by the manufacturer is its resting condition (minimum stimulus). Seal-in circuit: when an electrical relay uses one of its own switch contacts to continue its own coil energization after the initial triggering event has passed. Relevant to all manner of relay control circuits. References Summers, Wilford I. and Croft, Terrell, American Electrician s Handbook, Eleventh Edition, McGraw-Hill Book Company, New York, NY, 987.